Loading...
HomeMy WebLinkAbout2002-12-02 BRAA Ltr to OPHlonestroo, Rosene, Anderlilc and Associates, Inc. is r 3tive Action /Equal Opportunity Employer and Employee Owned December 2, 2002 Principals: Otto G. Bonestroo, P.E. = Marvin L. Sorvala, P.E. ■ Glenn R. Cook, P.E. = Robert G. 5chunicht, #?E. ■ Jerry A. Bourdon, RE, Senlor Consultants. Robert W. Rosene, RE, = Joseph C. Anderilk, P.E. = Richard E. Turner, RE. = Susan M. Eberiin, CAA, Associate Principals: Keith A. Gordon, P.E. ■ Robert R. Pfefferle, RE. ■ Richard W. Foster, RE. = David a. Loskota, P.E. Mark A. Hanson, P.E. - Michael T. Rautmann, PE. = Ted K. Field, PE. R Kenneth R Anderson, PE, r Mark R. Rolfs, RE, a David A. Bonestroo, M.B.A. ■ Sidney P. Williamson, RE., L.S. x Agnes M. Ring, M.B.A. = Allan Rick Schmidt, RE. _ Thomas W. Peterson, RE. v ,lames R. Maland, P.E. = Miles S. Jensen, P.E. ■ L. Phillip Gravel Ill, RE. = Daniel J. Edgerton, RE, ■ Ismael Martinez, P.E. = Thomas A. Syfko, P.E. = Sheldon J. Johnson - Dale A. Grove, P.E. s- Thomas A. Roushar, P.E. • Robert J. Devery, P.E. Offices: St. Paul, 5t. Cloud, Rochester and Willmar, MN ■ Milwaukee, Wl = Chicago, IL Website; www.bonestroo.com Minx. Kris Danielson Community Development Director City of Oak P ark .Heights 14168 Oak Park. Blvd., P. o. Box 2007 Oak Park Heights, NIN 55082 Re: Stillwater Ford — Conversion Van. Center Revised Grading & Utility Plan Review Bonestroo File No. 55 -02 -000 Dear mss: OWN, DEC - 4 2002 � D We have reviewed the revised grading and utility plan for the proposed Stillwater Ford — Conversion Van Center as submitted by METRO Land Surveying & Engineering. As you are aware, the owner' previously submitted improvements for this site for an Employee and Storage Parking Lot Addition. As a result of the proposed development revisions, revised .4 grading and utility plans were submitted to our office on November 26, 2002, and we have the following c ornments recommen atr ons : 1. The previous grading plan (under the employee parking lot scenario) routed storm water runoff to the southwest and -northeast corners of the parking lot, then .utilized curb cuts to allow the storm water to enter overland drainage ditches /swales. The current revised grading plan (under the conversion Van center scenario), proposes to route storm water runoff to the southeast and northeast corners of the parking lot. Additionallv, the revised grading plan calls for filling in the ditch along Neal Avenue North and installing storm sewer along the entire frontage of the site. 2. The grading plan we received contains handwritten revisions showing three curb cuts in the parking lot curb & gutter to allow storin water to enter drainage sw ales/depress ions, the elimination of proposed catch basins and storm. sewer exiting the parking lot, and revisions related to proposed storm sewer structures for the storm sewer in the filled ditch. These hand-written revisions need to be incorporated into the drawings and the proposed contours revised accordingly (the current contours do not correspond to the handwritten revisions). 3. Adequate riprap and/or other adequate erosion control measures should be placed at the three proposed curb cut locations. 4. A storm sewer profile is required for the proposed storm sewer necessitated by filling in the existing ditch. A. drainage area map and calculations are required to Verify that the proposed size and slope of the pipe are adequate for the storm water flows in that area. Elevations for the proposed beehive catch basin manholes need to be specified as well. 2335 West Highway 36 a 5t. Paul, MN 55113 a 651 -636 -4600 -a F ax: 651 -636 -1311 i • r 5. Another hand - written note calls for a 20" pipe connecting the existing catch basin in Neal Avenue North to the proposed storm sewer in the ditch. 20" is an uncommon size for storm sewer, and this should be called out as a 12" or 15" reinforced Concrete Pipe. 6. According to an email from Jay Johnson,' MnDOT has confirmed that they have issued a permit to Denny Hecker for a Wan Conversion Center on Neal Avenue North, Additionally, Jay's entail indicates that Brown's Creep watershed District has reviewed the revised grading plan, and will not require a new permit for the revisions (if the hand-written modifications are incorporated into the grading plan). We recommend the applicant submit the final revised grading plan (incorporating the hand - written revisions) and the City receive written , verification from B CWD indicating their acceptance of the final revised plan. 7. The 4" PVC sanitary sewer service shall be Schedule 40 pipe. 8. The 2" copper water service shall be connected to the existing mainline via a wet tap. If you have any questions or require additional information, please contact me at (651) 604 -4815. Sincerely, BONESTROO, ROSENE, ANDERLIK & ASSOCXATES INC Dennis M. Pos er, P.E. cc: Judy Holst, Acting City Administrator Jay Johnson, Public Works Director Jim. Butler, Building official Scott Richards — City Planner (Northwest Associated Consultants, Inc.) Harr Vierling City Attorney (Eckberg, Lammers, Briggs, Wolff & Vierling, P.L.L.P.) DNW, DDH, Pile — Bonestroo K\55101d\5tillwater Ford - Van Cnnv Or (Emp Fkcr) review- 12- 2- 02.doc