Loading...
HomeMy WebLinkAbout1999-08-25 Applicant Solicitation AmendmentU.S. Postal Service Facilities Department Solicitation Amendment . Amendment Number 01 Amendment Date 8/25/1999 2. Offeror /Contractor No other changes. 6. Contractor Signature Name of Person Authorized to Sign 4. The above numbered solicitation is amended as set forth in Block 5. NOTE: Offerors must acknowledge receipt of this amendment poor to the date and time specified in the solicitation by one of the following methods: a. By signing and returning one copy of this amendment; b. By acknowledging receipt of this amendment on each copy of the offer submitted; or c. By submitting a separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE SPECIFIED IN THE SOLICITATION PRIOR TO THE DATE AND TIME SPECIFIED FOR RECEIPT OF OFFERS MAY RESULT IN REJECTION OF YOUR OFFER. If, by virtue of this amendment, you desire to change an offer already submitted, such change may be made by telegram or letter provided such telegram or letter makes reference to the solicitation and amendment numbers, and is received prior to the date and time specified. The date and time specified for receipt of offers is extended to: Date: 9-3-99 Time: 3:00 pm 5. Description of Amendment Attached is description of Amendment 01 which includes: Adendum #1 to plans and specifications -5 pages Section 02810 -7 pages Sheets No. 1,2,3,4,5,6 Civil Addendum -2 pages Sheets R1, R2, R3 General Structural Notes- 1 page Drawing R1 1 survey drawing -No. 2987 Offers due date (9 -3 -99) has not been charmed-no extension. Date Signed Solicitation Number 193045 -99 -A -0046 Project Name and Location STILLWATER MN /CARRIER ANNEX NEW CONSTRUCTION OWNED Issued By U.S. Postal Service Kansas City Facilities Service Office 6800 W 64th St Ste 100 Overland Park KS 66202 -4179 Contact: Vickie L. Ford U.S. Posta Service Signature nt Jack ractin Officer . G u fsson Dat , 1i ned 8 UNREDSTdTES ffig POSTAL SERVICE ADDENDUM #1 TO PLANS AND SPECIFICATIONS FOR USPS STILLWATER, MN 55082 CARRIER ANNEX USPS PROJECT NUMBER Y73259 RRT PROJECT NUMBER 9907.01 ARCHITECT: Rafferty Rafferty Tollefson Architects, Inc. 253 E. 4th Street St. Paul, Minnesota 55101 Tel. (551) 224 -4831 Fax. (651) 228 -0254 MECHANICAL/ Gausman & Moore ELECTRICAL 700 Rosedale Towers ENGINEERS: 1700 West Highway 36 Roseville, MN 55113 Tel. (651) 639 -9606 Fax. (651) 639 -9618 STRUCTURAL Ericksen Roed and Associates, Inc. ENGINEERS: Structural Engineering 300 First Avenue North, Suite 420 Minneapolis, MN 55401 Tel. 612- 342 -9210 Fax. 612-342-9214 CIVIL Van Sickle Alien & Assoc. ENGINEERS: 2955 Xenium Lane North Suite 10 Plymouth, MN 55441 Tel. (612) 559-9100 Fax. (612) 559 -6023 DATE: August 20, 1999 The additions, omissions, corrections and clarifications contained in this Addendum shall be included as a part of the Contract Documents as provided for under the General Conditions of the Contract. This Addendum is a Contract Document and may apply to any or all contracts and subcontracts. Unless otherwise specified herein, all work required by this Addendum shall be in complete accord with the Contract Documents and subsequent Addendum thereto. This Addendum shall become part of the bid. The bidder shall insert the Addendum number in the space where indicated on the Proposal Form. Failure to comply may result in the bid being rejected. USPS STILLWATER, MN CARRIER ANNEX ADDENDUM #1 8/20/99 PAGE 1 CHANGES A. SECTION 00010 — TABLE OF CONTENTS 1. Division 16 Electrical — Delete section 13900 Fire Suppression from electrical sections and move it to Division 15 Mechanical. B. SECTION 02810 — IRRIGATION SYSTEM 1 Add the attached section to the specification. C. SECTION 08410 ALUMINUM WINDOWS, ENTRANCES AND STOREFRONTS 1. Paragraph 2.7 — Delete "NOT USED". D. SECTION 11160 — LOADING DOCK EQUIPMENT 1. Paragraph 2.7 Add paragraph to specification section: 2.7 MANUAL TRUCK RESTRAINTS IL CHANGES TO DRAWINGS A. SURVEY 1. Add the attached survey. A. Models: 1. Kelley: #STAR1 with Truck Alert. 2. NOVA: #300XP 3. Poweramp: [ J. 4. Rte-Hite: #MDL-65. B. Description: 1. Operation: Manual hand lift bar. 2. Communication: Manual light communication controlled through control box rocker switch. 3. Operating Range: 12 inches (30 cm) to 30 inches (76 cm) above grade. 4. Restraining Capacity: 32,000 pounds. C. Operation: 1. Restraint system must provide light communication and signs (straight and mirror image), both inside and outside the dock position, to provide instruction to dock workers as to safe entry into trailers, and to trailer drivers as to safe movement to or away from the dock position. 2. Restraint must have clear text and illustrative instructions on control box adjacent to rocker switch. 3. Restraint barrier to be activated in up and down positions through manual hand lift bar. D. One year parts and labor warranty, including electrical on all components. USES STILLWATER, MN CARRIER ANNEX ADDENDUM #1 8120/99 PAGE 2 B. SHEETTO.O1 t Detail 16: a. Type 'B': Change reference 3/A7.05 to 10/A7.05. 2. Detail 20: 2. Room Finish Schedule a. Add the following note to Janitor Room 106: "install fiberglass reinforced panels on walls behind utility sink. Panels to extend 4'-O" on either side of the sink and top to be at 6'-0" AFF. b. Change the following for Room 122: Delete paint type P -1 Ca SHEET A1.O1 1. General Site Notes: b. Add the following note: "20. Provide an irrigation system at all landscaped areas. Refer to specification (by addendum)." 2. Detail 1, Site Plan: a. Provide site fire hydrants in locations shown on Civil drawings (by addendum). D. SHEET A2.02 1. Add note at Door 120D stoop: "Provide positive drainage away from door. 2. Dimension at Mail Platform stair near door 120D to be 5' -2" wide. 3. Add note at bollards for Doors 1230 & 123D: "Coordinate location of bollards with door manufacturer. 4. Width of landing at door 120J to be 5'-8 ". 5. For clarification purposes, the ramp near Door 120J is 5'r-4" wide (east edge of ramp aligns with grid 'A', overlapping the brick pier by 4" to the east to allow for the guardrail along the ramp. 6. Add detail reference bubble '16/A7.03' at east wail of Building & Grounds room 121, and '16/A7.07' at west wall of same room. E. SHEET A2.03 a. Change spot elevation at southeast corner of HC parking stall from `946.9' to `947.0'. b. Change spot elevations at sidewalk at top of south curb cut from '948.8' to `948.7' and `9489' to `948.8'. a. Change note #10 to read: "Maximum slope of dock apron is 1% in any direction for the first 50 feet from face of dock. Maximum pavement slope is 5% and minimum is 2 %, coordinate with civil." 1. Add the following general note: "5. The coping width and wall thickness varies along Grids `E' and `8'. Refer to wall sections identified on floor plan for details ". LISPS STILLWATER, MN CARRIER ANNEX ADDENDUM #1 8120199 PAGE 3 F. SHEET A5.01 1® Elevations 1 and 2: Add the following note: Refer to roof plan for overflow scupper locations. Scuppers to be on coursing. 2. Elevation 2: Change El. 116i-0" to El. 120'-0* near grid 'A'. 3. Elevation 4: Change note pointing to equipment at the left two truck stalls from "Line of grade at dock face " to Dock levelor. G. $HELT1_1 1. Detail 8: Overflow scupper (dashed) is shown in wrong position. Lower so bottom is at elevation 117-4N. H. 27.0 1. Detail 16: Add the following note: 'Exposed CMU above flashing to be Type 1C with top course Type 2B". SHEET A7.03 Detail 4: Change note: "1" INSUL., BURGLAR..." to *I" INSULATED, BURGLAR RESISTANT GLASS IN FACTORY FINISH ALUMINUM FRAMES — INTERIOR GLAZED." 4. Add wall section 16/A7.03 to this sheet. See attached. 5. Detail 17: Change 8" dimension between grids to 9". J. SHEET A7.05 • t Detail 10: a. Delete horizontal rigid insulation below floor slab. b. Rigid insulation should be reconfigured to agree with detail 11/A7.05. K. SHEET A7.06 1. Detail 1: Note used. 2. Detail 9: Change note: "Molded Rubber Dock Bumpers" to "laminated rubber dock bumpers 2W X 1 'H X 6"D.* 3, Detail 12: Change note: °Pit frame by pit manufacturer . " to "Pit frame by metal fabricator — see 13/A7.06N. 4, Detail 13: Add note: "Dock bumpers to be half the thickness of dock seals; one bumper only at each side of dock leveler." 5. Detail 20: Revise rigid insulation at foundation to agree with detail 8/A7.04. USPS STILLWATER, MN CARRIER ANNEX ADDENDUM #1 8/20/99 PAGE 4 K. V.:LE= 1. Detail 8: Delete portion of %W plywood on wall to expose CMU similar to 16/A7.02. Exposed CMU to be Type 1C with top accent course Type 28. Provide flashing and counter flashing similar to 16/A7.02. 2. Detail 12: Replace top portion of this wall section with attached drawing 12JA7.07. 3. Add wall section 16/A7.07 to this sheet. See attached. L. SHEET A7.08 1. Detail 7: Delete 5/8w exterior grade gypsum board underlayment. M. SHEET A9.01 t Detail 14: Add a painted 2x wood cap on top of metal stud and gyp. bd. half wall. 2. Detail 14: Change detail so that gyp. bd. at half wall is flush with concrete below. 2. Detail 10: Modify detail to include a foundation wall and footing at 8" CMU wall per structural drawings. 3. Detail 20: Change "BITUM. PARKING LOT PAVING" to "CONCRETE APRON". N. SHEET A9.02 1. Detail 6: Add to Note 4: "Wood blocking may be used in lieu of metal backing plate." O. SHEET A9.03 1. Add plan details 5, 9 and 10/A9.03 to this sheet. See attached. P. SHEET A10.01 'I. Detail 13: Add note: Provide 'Fire Extinguisher' sign above fire extinguisher at all locations — see 9/A10.01 for sign type." 111 CHANGES TO CIVIL DRAW1NCS See attached addendum by VSA. IV. CHANGES TO STRUCTURAL DRAWINGS — See attached by ERJS. V. CHANGES TO MECHANICAUELECTRICAL DRAWINGS AND SPECIFICATIONS 1. No changes. 2. Provide power, wiring and connections, as required, for manual truck restraint (Section 11160); coordinate with electrical and manufacturer. END OF ADDENDUM USPS STILLWATER, MN CARRIER ANNEX ADDENDUM #1 8/20/99 PAGE 5 United States Postal Servic. ASBD, SSBD, StorCAD /D MASTER SPE ICATION PART 1 GENERAL 1.1 SUMMARY SECTION 02810 IRRIGATION SYSTEMS A. Section Includes: 1. Design and construction of full site irrigation system, to cover all landscaped areas of site. 2. Pipe and fittings. 3. Sprinkler heads. 4. Control system and connection to electrical supply. 5. Trenching, installation of system and connection to water source; testing and backfilling. B. Related Documents: The Contract Documents, as defined in Section 01110 - Summary of Work, apply to the Work of this Section. Additional requirements and information necessary to complete the Work of this Section may be found in other Documents. 1.3 SYSTEM DESCRIPTION A. Design Requirements: 1. Coverage indicated on Drawings and specified herein. Layout portions of irrigation system not indicated on Drawings to meet specified coverage in compliance with local codes and regulations. 2. Complete irrigation system including trenching and backfilling for all pipes, values and drain pits, providing mains, laterals, risers, fittings, sprinkler heads, values, controllers, electric wiring, and necessary specialties and accessories. 3. Sleeves beneath parking areas, walkways, roads, and driveways where required. 4. Regulate and adjust sprinkler heads, timed sequence control devices, sectional valves and rain overrider. 5. Each zone to comprised of approximately equal water demand. Pressure not to exceed 6 feet per second. 6. Sprinkler heads in a zone shall have the same precipitation rate. 7. Provide 100 percent coverage by locating heads as recommended by the manufacturer. Proper overlap shall prevent 'scalloping ". no throw is permitted over walks, drives or buildings. 8. Turf and unlike plant materials shall be zoned separately based on water needs. 9. Locate heads discretely using risers only in shrub beds. 10. Heads adjacent to pavement shall be installed on swing joints. 11. Consider all plant heights and grade changes in design and installation of the irrigation system. 1.5 PROJECT CONDITIONS A. Existing Utilities: 1. Be responsible for locating and identifying existing utilities. Notify Contracting Officer of any conflicts which affect the approved irrigation layout. B. Obstructions Below Grade: 1. If obstructions such as rock or underground construction work are encountered in any irrigation excavation work, alternate locations will be selected. Where locations cannot be changed, remove obstruction. The obstruction shall be removed to a depth of not less than 3 feet below grade. USPS MASTER SPECIFICATION V2.0 02810 1 Issue Date: 03/17/1998 IRRIGATION SYSTEMS 1 United States Postal Service - MSBD, BD, StorCADID MASTER SPEC I FI CAT, Co Damage by Leaks: 1. Be responsible for damages to the grounds, plants, walks, roads, building piping system, electrical systems, and their equipment and contents caused by leaks in piping systems being installed or having been installed. Repair damages so caused at no additional cost to United States Postal Service. D. Staking: 1. Be responsible for location staking. Irrigation head locations shall be determined by calculating dimensions from approved shop drawings. Adjustments may be necessary to avoid interference with underground obstructions. 1.6 WARRANTY A. Repair any settling of backfilled trenches which may occur during the warranty period. B. Restore and all damaged plantings, paving, or improvements within the warranty period. C. Materials and equipment shall be warranted in writing against defects in materials and workmanship by the respective manufacturers. -These -- written- warcanties- shatt-b&-assembled -- and -gib he- n►ne t the - time -of-- substantiates ' .All installation work shall be guaranteed for twoor a year after final acre tancesubstanti etion. D. No claims under warranty shall be considered for materials damaged or destroyed by vandals or damages caused by unauthorized operation of the system. 1.7 MAINTENANCE TOOLS A. Provide 2 sets of tools for removing, disassembling and adjusting each type of sprinkler head and valve supplied. 1. Provide three uick cou lin ke s and three 314 inch hose swivels as :' art of this contract. B. Provide 2 five foot keys for operation of gate valves. C. Provide 2 keys for each automatic controller. PART 2 PRODUCTS 2.1 MATERIALS A. Heads, valves, controllers, backflow preventers, yard hydrants and other components as scheduled on shop drawings. B. Pressure Mainlines and Non - Pressure Lateral Lines: All pipe, in sizes indicated on the shop drawings shall be mark continuously and permanently with the following information: Manufacturers name, nominal pipe size, class or schedule, and NSF approval, and type of pipe. 2.2 PIPE AND PIPE FITTINGS A. Irrigation Mains: 1. Pipe: ASTM D 1784, PVC Class -200, SDR -21, 260 psi maximum. 2. Joint: ASTM D 2241 bell end type. 3. Fittings: Schedule 40, ASTM D 2466 solvent cement type. B. Zone Lateral Lines: LISPS MASTER SPECIFICATION V2.0 02810. Issue Date: 03/17/1998 IRRIGATION SYSTEMS United States Postal Service 4SBD, SSBD, StorCAD/D MASTER SPEk CATION 1. Pipe: ASTM D 1784, PVC Class -200, SDR -21. 2. Joints: ASTM D 2241 bell end. 3. Fittings: ASTM D2 466 Socket type. 2.3 VALVES A. Gate Valves: 1. 3 Inch and Larger Iron body, non - rising stem, threaded ends. 2. 2 1/2 Inch and Smaller. Type 1, class 150 psi, threaded ends. B. Station Control Valves: 1. Station Control Valves: Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. a. "PE Series" - Rain Bird Sales, Inc., Glendora, CA, (818) 963 -9311. 2. Valve Type: Remote control valves. Substitutions: Permitted. . Primers and Solvents: 1 _ As recommended by PVC pipe manufacturer 2.4 SPRINKLER HEADS A. Small Area Heads(for use in small lawn/shrub areas): 1. Small Area Heads: Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. a. Cycolac (plastic) "1800 Series" - Rain Bird Sales, Inc., Glendora, CA (818) 9639311. 2. Each head shall have an interchangeable nozzle (available in different patterns and distances of throw). Substitutions: Permitted. 3. Each head shall have a basket screen. 4. Provide pressure compensating screens (P.C.S.) as indicated on Drawings. USPS MASTER SPECIFICATION V2.0 B. Large Area Heads (for use in large lawn areas): 1. Large Area Heads:' Subject to compliance with requirements, manufacturers offering specified Items which may be incorporated in the work include the following. a. "#R50" - Rain Bird Sales, Inc., Glendora, CA, (818) 963 -9311. 2. Use adjustable arc (ADJ) unless Drawings show full circle (360). Permitted. 3. If water pressure Is excessively high, provide pressure reducing feature on zone valves. 2.5 AUTOMATIC CONTROLLERS A. Automatic Controllers: Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. 1. Manufacturer "#RC- Series" - Rain Bird Sales, Inc., Glendora, CA (818) 963-9311. a. "LPP -K" - (Primary Surge Protector). b. "LK -712" (Lock). Provide Owner with two keys. B. Section 01600 - Product Requirements: Product options and substitutions. Substitutions: Permitted. C. Stations: Control stations as shown on shop drawings. D. Station Timing: Independent for each station with each infinitely adjustable from 0 to 60 minutes. E. Day Programming: Pprogramming dials encompassing 14 day cycle. F. Operation: Capable of automatic, semi-automatic or manual function as selected by operator. 028103 Issue Date: 03/17/1998 IRRIGATION SYSTEMS 1 United States Postal Service - MSBD ;BD, StorCAD/D MASTER SPECIFICAT G. Power Requirements: 1. Input: 115 volt AC. 2. Output to Valves: 24 Volts AC. H. Provide reset circuit breaker for overcurrent protection. I. Provide master manual on-off switch. J. Rain Detector 1. Rain Detector Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. a. "Mini-Clik II" by Glen-Hilton Products, Inc., Bethesda, MD, (301) 441-8673. 2. Section 01600 - Product Requirements: Product options and substitutions. Substitutions: Permitted. 3. Mount on rear of Landscape Maintenance Building as per Manufacturer's recommendations. 2.6 VALVE BOXES A. Valve Boxes: Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. 1. Ametek, Plymouth Products Division, Sheboygan, WI (414) 457-9435, Superflexon Valve Box "No. 10-170-001" with cover No. "10-173-004", with pentagon (1) locking device. B. Section 01600 » Product Requirements: Product options and substitutions. Substitutions: Permitted. C. Paint box covers matte black with paint specified in Section 09900 - Painting. 2.7 SWING JOINTS A. Swing joints are to made of Schedule 40 pipe with insert to male thread combination elbows. The swing joint will allow for precise adjustments of each head to grade as well as protecting both the head and the pipe from damage if struck by unusual force. 2.8 CONTROL WIRE A. Control Wire: All wire shall be #14 AWG solid copper, single conductor, rated "U.F." with "U.L." listing, with 600 volt PVC insulation. All splices shall be made with wire nuts and totally encased in DBY direct burial splice kits. 2.9 QUICK COUPLING VALVES A. Quick Coupling Valves: Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. 1. Rain Bird "3RC". B. Mount quick coupling valves on 3/4 inch galvanized triple swing joints. All swing joints are to be assembled using two to three wraps of Teflon tape.--F-ufnish-to-the-Owner tticee-314-inch-hose-swivels-a&-pactof-thi&-mitfact, 2.10 BACKFLOW PREVENTER A. Backflow Preventer Subject to compliance with requirements, manufacturers offering specified items which may be incorporated in the work include the following. 1. Rain Bird "Model DCA Series-R". LISPS MASTER SPECIFICATION V2.0 02810 - 4 Issue Date: 03/17/1998 IRRIGATION SYSTEMS 1 United States Postal Servic JISBD, SSBD, StorCADID MASTER SPL 'ICATION B. Section 01600 - Product Requirements: Product options and substitutions. Substitutions: Permitted. C. Backflow preventer shall meet or exceed all local codes or requirements, size according to shop drawings. PART 3 EXECUTION 3.2 PREPARATION A. Layout and stake locations of system components. B. Review layout requirements with other affected work. Coordinate locations of sleeves under paving to accommodate system. 3.3 INSTALLATION A. Sequencing: 1. Install sleeves under roads & pavement prior to commencement of paving. 2. Install sprinkler system after completion of site grading. B. Minimum Cover Below Finished Grade: 1. Zone Lateral Pipe: Not less than 12 inches. 2. Mains: Not less than 24 inches. C. Clearance Horizontally Between Lines: 1. Pipe 2 inches and smaller. 4 inches. 2. Pipe 2 112 inches and larger 12 inches. 3. Other services: 12 inches. D. Maintain a minimum 1 inch vertical clearance between lines crossing at an angle greater than 45 degrees. E. Trench Width: Not less than 5 inches. F. Install underground piping so that it is not in contact with concrete, existing piping or other hard objects. Provide a minimum clearance of 2 inches between piping and hard object. G. Thrust Blocks: Concrete thrust blocks shall be provided on the thrust side of mains. H. Backfill: Section 02315 - Excavation and Fill. 1 . Material shall not contain brick, rock, lumber or organic materials subject to decomposing. 2. Trenches, after backfilling, shall be water filled and settled to prevent aftersettling. 3. Level with finished grade. 4. After backfilling and water settling, soil, around pop-up heads shall be tamped and heads left level with grade and plumb. I. Piping Installation: 1. Install plastic pipe in a manner to provide for expansion and contraction. 2. Cut plastic pipe with a hand saw. Ensure a square cut. Remove burrs at cut ends prior to installation. 3. Plastic to plastic joints shall be solvent - welded. Solvent compatible with pipe and able to withstand specified pressure requirements. 4. Solvent Welded Joints: a. Thoroughly clean pipe and fitting with all purpose primer /cleaner and clean dry cloth. USPS MASTER SPECIFICATION V2.0 02810 5 Issue Date: 03/1711998 IRRIGATION SYSTEMS 1 United States Postal Service - MSBD, .BD, StorCADID MASTER SPECIFICAT, b. Apply a uniform coat of solvent to the outside of the pipe. c. Apply solvent to the fitting. d. Re -apply a light coat of solvent to the pipe and quickly insert into the fitting. e. Give the pipe or fitting a quarter turn to ensure even distribution of the solvent and make sure the pipe is inserted to the full depth of the fitting socket. f. Hold in position for 15 seconds. g. Wipe off excess solvent that appears at the outer shoulder of the fitting. h. Allow joints to set at least 24 hours before pressure is applied to the system. J. Valves: 1. Manual Valves: Install manual valves in a valve box extending from grade to valve body, with minimum of 4 inch cover measured from grade to top of valve stem. 2. Automatic Valves: a. Install automatic valves plumb to within 1/16 inch, in a valve box extending from grade to valve body, with minimum of 4 inch cover measured from grade to top of valve stem. b. Automatic valves installed under sprinkler heads may be installed without valve box. c. Automatic drains valves: Locate downstream of each control valve at the tow point. K. Sprinklers and Quick Coupler 1. Install plumb to within 1116 inch. 2. Heads at Walks and Curbs: Set flush to within 1/8 Inch. 3. Lower sprinkler heads to finished grade after lawn has become established and has settled. L. Control Wire: 1 . Bury wires taped to side of pipe in same trench. 2. Bundle multiple wires and tape together maximum 10 feet on center. 3. Provide a 10 inch loop in wire at each valve where controls are connected. 4. Provide 10 inch loop in wires at not over 100 foot intervals. 5. Make electrical splices waterproof. M. Automatic controller. Mount automatic controller in accordance with manufacturer's recommendations. 3.5 FIELD QUALITY CONTROL A. Section 01450 - Quality Control: Field testing and inspection. B. Inspection: 1. Trenching. 2. Pressure supply line installation and testing. 3. Lateral line and electrical valves. 4. Coverage tests. C. Testing and Flushing 1. Flushing: a a. After all piping, risers, and valves are in place and connected, but prior to installation of sprinkler heads, yard hydrant assemblies, and hose valves, thoroughly flush piping system under a full head of water. b. Maintain flushing for 3 minutes though furthermost valve. c. After flushing, cap all risers. 2. Adjusting: a. Flush and adjust all sprinkler heads for optimum performance and to prevent over -spray onto walks, roadways, and buildings. b. if it is determined that adjustments in the irrigation equipment will provide proper and more adequate coverage, make such adjustments prior to planting. Adjustments may include changes in nozzle sizes and degrees of arc as required. 02810 4 6 USPS MASTER SPECIFICATION V2.0 Issue Date: 03/17/1998 IRRIGATION SYSTEMS United States Postal Servic&. JISBD, SSBD, StorCAD/D MASTER SPE !CATION 3. c. Lower raised sprinkler heads within 10 days after notification by Contracting Officer. d. Sprinkler heads shall be performed at no cost to United States Postal Service. Testing: as Test all pressure lines under hydrostatic pressure of 150 pounds per square inch. Prove water tightness. b. Testing of pressure main lines shall occur prior to installation of electric control valves. c. Sustain pressure in lines for not less than 2 hours. If leaks develop, replace joints and repeat test until entire system has been accepted. d. Furnish force pump and accessory test equipment. e. When the irrigation system is completed, perform a coverage test in the presence of the Contracting Officer to determine if the water coverage for planting areas is complete and adequate. Correct inadequacies of coverage due to deviations from Drawings. Complete test before ground cover is planted. 3.5 SYSTEM OPERATION AND ACCEPTANCE A. Operation: 1. Operate the completed system for the Contracting Officer inspection at which time each sprinkler head shall be visually checked for coverage, adjustment, installation and performance; valves shall be inspected for adjustment, installation and proper automatic manual control; "record documents" will be checked for accuracy; cleanup of site will be checked; and general items such as manual drain valves, controller and quick couple valves will be inspected for the maintenance period. B. Instruction. 1. Instruct United States Postal Service personnel in complete operation and maintenance of the irrigation system including but not limited to the controller operation, maintenance of the system's filters, adjustment of heads and winterization of system. USPS MASTER SPECIFICATION V2.0 END OF SECTION 028107 Issue Date: 03/17/1998 IRRIGATION SYSTEMS X L1J cc tr W 0Q 1 co cr w w z z w co g cf) O 9 A9.03 CAD File: FACE OF CMU 16'-8" TO GRID 'C.8' 7 1112' - 1 + ° " °° PLAN DETAIL AT INVES•flGA•flVE OFFICE TYPICAL EXTERIOR WALL CONSTRUCTION S CMU WALL BELOW 3 5/8" MTL STUDS AT 8" OEC. Fac. Ch. Sect. Para. Detail 41=12 UM 112. MOD MEM W Z cc W Er 0 < i cr W Z W CO co O FACE OF CMU 10 A9.03 4( CAD File: co 16'-8" TO GRID '0.8' WALL TYPE 'K2' °" °'° PLAN DETAIL AT INVESTIGATIVE OFFICE 8� CMU WALL BELOW WALL TYPE SIM. TO 'K2' WALL TYPE 'H3' Fac. Ch. Sect. Para. Detail COM r� 5. a c4 re V3 La LL1 � w —I x x E) X W Z Z ec W EL" cr: Ua I co cc w CO N g N , � ADDENDUM # 1 4 SHEET N0. 2x WO BLOCKING COORD. W/ INSUL, THICKNESS EL 124' --0" __ ..._...�. (T.O. STUD & MASONRY) BALLASTED EPDM MEMBRANE ROOFING OVER 2 LAYERS OF 2" POLY ISO INSUL W/ STAGGERED JOINTS OVER 6 MIL POLY VAPOR BARRIER ON 1 1/2" MTL DECK 5/8" GYP. BD. VAPOR RETARDER 6" 16 GA. MTL STUDS CO 16" G.C. INSUL -- R19 � 12 A7.o ARIES Dote: 8-20-1999 scale: x- -Refs: CADD Reference No,: 9907ADD1.5WG RRT Project No.: 9907.01 CAD File: NOTE: BOTTOM PORTION OF WALL SECTION THE SAME AS ORIGINAL DOCUMENTS 1 ^8 " I 1 do l 1:1/4' • 1'-.4• e l oits. ook • ov.- A 4 � petal' PARTIAL WALL SECTION AT INSPECTOR'S ENTRY 5/8" EXTERIOR GYP. BD. SHEATHING 15 lb. FELT Fa c I Ch. STOP INSUL 12" ABOVE DECK, MIN. Sect. USPS STILLWATER -- CARRIER ANNEX OAK PARK HEIGHTS, MINNESOTA TIES — TYP. — 16" O.C. MAX. BOTH VERT. & HORIZ, CMU VENEER -- TYP. — 4" NOM. THICKNESS L' -- 8" NOM. HEIGHT A 0 t Para. (Detail RAFFERTY RAFFERTY TOLLEFSON ARCHITECTS 251 EASY FOURTH MEET SAINT PAUL, ...WA 53101 (11:121 : -4e34 1# (11.1 -1 ADDENDUM # 1 5 /16 \ [?ate: 8 -20 -1999 Seale: X —Refs: CAC }I] Reference No.: 9907A0D1.0wG RR T Project No.: 9907.01 BLDG GROUNDS , 1 1 car Sras DAR s' co.crED mum BASE (F. VAPOR rte) I SGQ 3 ■8! °' - -n■ nu vO0 VI/ Re ER nu0xs P. fltll. w/ INSUL PKIAVE0 1PEkt Now. 90019 Ova 2 LAT. Or 0 Pools,. ST0CEREO . 0 Oe I S /1' WM. 0900 0909 8E &lo foofr c Or DELI; &TOP OF GYP. B0. 8' 00 90 f rte 2 ►s carer. 5/6' CI, 80. ON 1' 0 0090*o' DORMS w/ 0 9090 IOOot. S' S o09o.E1 C.U.U. 117E 1 19911 PIATFQRIA PA ER - 51E 0019 6/A4.00 EASE 05 SCRE0000 i' C.C. SUB OM 6` COWACT[D 1:MIJUR MSC ON 6 POLY EL 100' -0' rlrL fl.R Detail. WALL SECTION a BLDG AND GROUNDS/ PLATFORM f 7.o7 CaD File ATFC�RM I�IALL Foc. h. 1Sect. 1 1 t USPS STILLWATER — CARRIER ANNEX OAK PARK HEIGHTS, MINNESOTA Fora. I Detor'1 RAFFERTY RAFFERTY TOLLEFSQN ARCHITECTS 2s3 EASI roaalx S>rtiEEr SFSkS PAUL ! q }h 555C1 r651] 221 -1671 iAt f6,5} M-0264 ADDENDUM # 1 6 SHEET 10 Dote: 8-20-1999 Scale: X —Reis: CARD Reference No.: 9907A0D1.DwG RRT Project t4o.: 9907.01 Al 11[ 1O9 991P9 9►1 US1t8 EYiu uERS.E iroarrrc vrER sus' sx & .1( 010. BD. 11 P.L4! EPf Y1S11 ....AK UP8Os8R NOM UPEPED e1s . it CRICKET LOCAA9 - SEE Rea P90 4' C.C. 508 0,0 COUPAC1W GRA0.IR 801 oop (8, oR I R) BOW !MAKER 5" C.C. SW mr.R 6 CC4.1411D CRAW. Bin (HO YAP. EoPaER) ca,C. Mow - SE[SM.T.4 Q 81AS001P0 98001 P001126 980 1 0110799 Of 2 901150. mum. w/ 1160 B1D .9015 Di 1/2' uflm. DEC+{. - R)c• , ti• BOW Em El. 11" 8010 BEM EL i 13' - l' 12 STANOARO C1sU 61.90 & GROUNDS P1 EL 1[10' -{T• FW. ELfV. 116 petal: WALL SECTION a GARAGE/ BUILDING AND GROUNDS WALL CAD Fire: Scale: Foc. ICh. !Sect. jParo. !Detail USPS STILLWATER -- CARRIER ANNEX OAK PARK HEIGHTS, MINNESOTA RAFFERTY RAFFERTY TOLLEFSON ARCHITECTS 253 EAST FOURTH STREET VAT PFlJL LA 5510. [Am) rae [s. l 22,02a4 CIVIL ADDENDUM TO CONTRACT DOCUMENTS FOR USPS CARRIER ANNEX STILLWATER, MINNESOTA OWNER: United States Postal Service ARCHITECT: Rafferty Rafferty Tollefson Architects 253 East Fourth Street St. Paul, MN 55101 CIVIL ENGINEER: Van Sickle, Alien & Associates, Inc. 2955 Xenium Lane North, Suite 10 Plymouth, Minnesota 55441 RE: Addendum No. One VAA COIVEIVI. NO.: 99129 DATE: August 20, 1999 The additions, omissions, corrections and clarifications contained in this Addendum shall be included as a part of the Contract Documents as provided for under the General Conditions of the Contract. This Addendum is a Contract Document and may apply to any or all contracts and subcontracts. Unless otherwise specified herein, all work required by this Addendum shall be in complete accord with the contract documents and subsequent Addendum thereto. This Addendum shall become part of the bid. The bidder shall insert the Addendum number in the space whereindicated on the Proposal Form. Failure to comply may result in the bid being rejected. A. Modifications to Civil Drawings 1. Drawing Sheet Cl: Refer to Supplemental Drawing Sheet R3 for revised information regarding the grading at the Handicapped Parking Area and at the drop box access sidewalk. Civil Addendum No. One Pa Au st 20 1999 •• 2. Drawing Sheet C2: Refer to Supplemental Drawing Sheet R1 for additional information regarding the revised watermain. Two (2) site hydrants were added. 3. Drawing Sheet C3: Refer to Supplemental Drawing Sheet R2 for Fire Hydrant and Gate Valve Detail. GAP ROE PEC1.991291CIVIL ADDENDUM #1.DOC End of Addendum One ellriliistul +stlt�lltw� #� 1■■■■■■■■■ ■■ Imiammommiis INN • ■ • • 1!■ r KEW .4 MI■ p* WATT U sra 1 1. fi MfATI sTa NORTH xnnExrt xAFFExrY tv;.LUsost 3I fOinm torn �} r•-.0 rr poi Bt*.D*4G �c GROUNDS #2 #FE.946.04 UNITED STTES posra SERVICE CARRIER ANNEX uSPS STILLWATER STILLWATER, MINNESOTA L L LL.L SEE 17/C3 FOR 1 1 1 1 1 1 1 1 PROPOSED BUILDING FFE = 948.00 VIS INV 942.25 VERIFY LOCATION AND INVERT WITH UECHMlICAL NW 1142.25 VERIFY LOCATION AND INVERT M H E0-1ANCAL 114.44FORLIER PD )ED FIRE HYDRANT ._.,rE VALVE =D PARTIAL PLA VAN SICKLE, ALLEN do ASSOCIATES 2955 Xenium Lane North, Suite 10 Plymouth, Minnesota 55441 (612) 559-9100 FAX (612) 559-6023 1 " =50' .J, REVISION r-- N DATE: 8/20/99 1 1 1 1 1 1 VAA JOB: 99129 G 6 SERVICE M 939.0 9.D Y 929.00 ELD VERIFY 0CATIOH & OF 6' R1 SEE NOTE # NATIONAL STANDARD OPERATING NUT N RAFFERTY RAFFERTY TOUIFSON IPICrf oa poi mini "HYDRAFINDER" 3'-O" LA 0 U z THRUST BLOCK 2.25 • SQ.FT. MINIMUM USPS STILLWATER STILLWATER, MINNESOTA 2 1/2" HOSE CON = r.ECTIDN (N.S.T.) 4 1/2" PUMPER CONNECTION (N.S.T.) GRADE 1 CU. YD. GRAVEL OR CRUSHED ROCK W/ 2 LAYERS 4 MIL. POLY. TIE HYDRANT TO VALVE W/ 2- 3/4" DIAMETER TIE RODS 8" CONCRETE BLOCK UNDISTURBED SOIL VALVE BOX DROP LID LABELED WATER. GATE VALVE BOX 7'-6" EXTENDED 3 PIECE, "G" BOX NO. 6 ROUND BASE, 5 1/4" SHAFT BUFFALO BOX. " GATE VALVE -TIE VALVE TO TEE ON MAIN WITH 2 3/4" DIAMETER TIE RODS 8" CONCRETE BLOCK NOTES 1. ALL FIRE HYDRANTS SHALL BE PAINTED PER CITY REQUIREMENTS. 2. TOP OF FIRE HYDRANT DESIGN ELEVATION SHALL BE 2.5' ABOVE FINISH GRADE. 3. TOPS OF VALVE BOXES SHALL BE SET SO AS TO PROVIDE 12" OF UPWARD ADJUST. 4. COMPLY WITH CITY OF STILLWATER STANDARDS. . 5. FIRE HYDRANT CAPS TO BE CHAINED. PROVIDE (PENTAGON NUT ON CAPS). YDRANT & GATE VALV UNITED STATES POSTAL SERVICE CARRIER ANNEX VAN SICKLE, ALLEN & ASSOCIATES 2955 Xenium Lone North, Suite 10 Plymouth, Minnesota 55441 (612) 559 -9100 FAX (612) 559 -6023 REVISION NO SCALE DATE: 8/20/99 VAA JOB: 99129 IT WI 0 R14 946.0 3aiuIu11111M r. IF ■• ,k PROPOSED BUILDING FFE = 948.00 NORTH %h\ RIVISIID PARTIAL PLA 0 50' 100' 150' TRANSEORSAER PAD . LF TR EHCK ORM RBA 943.7 L ; En I , II l iipt„ MUM � 7- � - � rpinuor somos NE RD 939.0 VERI DON OF iw EXtS71140 t 7` WATER MAIN REVISION DATE: 8/20/99 VAA JOB: 99129 RAFFERTY RAFFERTY TOLLEFSON ARCHITECTS 3 Olt MAIM Mar 0.1..0 VSPS STILLWATER STILLWATER, MINNESOTA UNITED STiTES POSTIILSB CARRIER ANNEX VAN SICKLE, ALLEN & ASSOCIATES 2955 Xenium Lane North, Suite 10 Plymouth, #Tmesota 55441 (612) 559-9100 FAX (512) 559-6023 vicksen oad & " 56 cites Structural Engineers 300 First Avenue North Ste 420 Minneapolis, MN 55401 -2608 Telephone: (612) 324 -9210 Facsimile: (612) 342 -9214 LISPS STILLWATER ERA COMM # 99072 (1) DENOTES ADDENDUM NUMBER Reference Drawing S1— General Structural Notes and Typical Details (1) A. Revise detail 15/S1, change text "see 6/S5 for wall reinforcement" to "see 11/S5 for wall reinforcement" and change text "see 6/S5 for FTG size & Reinf" to "see 11/S5 for FTG size & Reinf'. (1) B. Revise detail 16/85, Change text "see 6/S5 for wall reinforcement" to `see 11/S5 for wall reinforcement" and change text "see 6/S5 for FTG size & Reinf' to "see 11/S5 for FTG size Reinf'. Reference Drawing S2 — Typical Details (1) A. Revise detail 13/S2, change text "2 /2" Cone on 1" 26 GA form deck reinf w16x6 w2.1 x w2.1 WWR to "2 '/2" cone on 1" 24 GA form deck reinf w/6x6 w2.1 x w2.1 WWF. Change text "TS 4x4x 1/4" to "w4x13 ". Reference Drawing S4.2 — Roof Framing plan (1) A. Revise plan S4.2 as per enclosed partial plan R1. Adjust joist spacing J building and grounds room for roof hatch. 12" emu parapet on grid "E ", ref 14/S6, extend to end of canopy. Reference Drawing S6 — Sections and Details (1) A. Revise Mezzanine plan 16/S6, change section 15/S6 to 15/S2; w Le- 0 0 ricksen aecl & Associates Itnacturei 300 Mit ■ii. nth 42a INN 115401—t606 00 10K1 M 1 cc In I 1OK1 -1 1 OK 1 I 1 0 ogr CN W14 X 22 ( +2 /2 X 22 (+2 1/2") 14K1 14K1 W 2OK6'I 20)16_4 tY W14 X 22 (+ W14 X 22 (4 112 CA a UNITED STATES PARCH. SERVICE STLLWATEF1 MN COMM. NO.: 99072 a 1 CO C) N w Ls- 0 TOS EL 0 W21 11V-2 5/8 TOS EL0W21 115 -2 5/16 TOS EL W21 114'-6 1/4" TOS EL0W21 114' -4 CHECKER: RT 8 -17 -99 Ri