HomeMy WebLinkAbout1999-12-09 Bayport Fire Department Inspection Report Inspection Report �`
Bayport Fire Department• 301 2nd Avenue North • Bayport, MN 55003 • (612) 439-6992
Date Time C- Property Address Phone
/Z/a'9— 77 _ 9,f 6l.10 oc6,td 41,E.. ,1/. v.Prii. s `7'39— Z25—/
Building/Pr erty tm z, Correspondence To
Occupa cy Class Const. Type Const. Year No. of Stories Sq. Ft. Floor No. of Occupancies Inspec. Type
Owner Name Address CityState Zip
6/Z0 o e 44c. 426 o 0,H it/2.__ /1?,, 5. z-_ _
V-Does Not Meet Requirements NV-Appears To Meet Requirements NA-Not Applicable (See Additional Instructions On Back)
V NV NA 1. Exterior V WV NA 4. Storage V NV NA 8. Sprinkler Systems
❑ EN- ❑ a. Fire Lanes marked/unobstructed ❑ IN ❑ d. No combustible storage under ❑ ❑ b. Controls readily accessible
❑ ❑ b. Address visible unprotected stairways ❑ ❑ c. Valves locked open or
❑ IR ❑ c. Fire hydrant(s) �{`
accessible 0 ❑ t 2' below supervised
ceiling (unsprinklered) ❑ CId. Properly serviced
CI / ❑ d. Combustible accumulation(s)
acceptable ❑ ❑ Ei f. Storage maintained 18" below ❑ ❑ e. Heads in good condition
❑ ❑ � e. F.D. lock box present sprinkler heads ❑ ❑ f. Wrench/spare heads present
❑ ❑ , f. F.D. connections visible/good ❑ ❑ g. Aisles maintained - 44" min. 9. Fire Alarm Equipment
condition ❑ ❑ h. Rubbish, oily rags, waste ® ❑ ❑ a. Detectors (smoke, heat) properly
2. Exit Features material property stored installed
❑ M ❑ a. Adequate number of exits 5. Flammable/Comb. Liquids ❑ ❑ b. Pull stations properly installed
❑ t ❑ b. Exits, aisles and corridors ❑ E ❑ a. Proper quantities /KI ❑ ❑ c. Detectors needed
free of obstructions ❑ r ❑ b. Proper storage/dispensing i• ❑ ❑ d. Properly serviced/maintained
❑ ` ' LI c. Exits openable from inside ❑ [r ❑ c. No sources of ignition ❑ ❑ e. Tests/drills conducted
❑ ❑ d. Exit hardware present and ❑ e ❑ d. Adequate ventilation 10. Other Fire Protection Equip.
L ❑ e. Exit signs present
operational.' CI IX ❑ e. Proper electrical equipment CI a. Standpipes needed q p
CI
f. Exit illumination adequate 6.Utility, Mechanical,HVAC ❑ CI b. Standpipe/hose in good cond.
ri ❑ g. Emergency lighting present and ❑ I U a. Relief valve present on boilers ❑ ❑ c. Adequate coverage
u operational and water heaters ❑ ❑ d. Hood system-fuel shutoff present
X LI ❑ h. Occupant load posted and ❑ ❑ b. Shut off valve present on gas ❑ ❑ e. Properly serviced/maintained
maintained appliances
Li , ❑ i. Interior finish acceptable ❑ r CIc. Approved piping/connectors 11. Electrical
❑ ❑ J. Stairway ID present and appliances used ❑ X1--0 a. Appliances/fixtures in good
❑ d. Proper venting present and in condition
CI
3. Construction Features good condition ❑ A ❑ b. Overcurrent protection present
❑ 70❑ a. Fire separations present ❑ El e. Combustion air supply present ❑ ❑ c. Proper wiring/connections
and maintained ❑ [ ❑ f. Adequate clearances between ❑ ❑ d. Extension cords not used in
❑ t ❑ b. Openings in fire walls sealed combustibles and appliances place of fixed wiring
❑ ,i E c. Rated fire doors present and ❑ ❑ g. Clean ducts and filters ❑ II ❑ e. Proper use of wiring and equip.
operational (closing/latching) ❑ /] n f. 30" clear access to panels
Cl i ❑ d. Vertical openings acceptable T xtinguishers provided
❑ ❑ a. Readily accessible
4. Storage ❑ ❑ b. Proper number and type 12. Miscellaneous
❑ tK ❑ a. Storage neat and orderly ❑ ❑ ❑ c. Suitable location ❑ ❑ a. Proper storage of compressed
❑ iclf ❑ b. No combustible storage ingases
boiler or mechanical rooms �`` ❑ `d. f'ro senrtced/mamtained ❑ ❑ b. Interior decorations acceptable
❑ LI c. No combustible storage in 8. Sprinkler Systems or flame retardant
unprotected attics ❑ ❑ I a. Adequate coverage ❑ r ❑ c. No smoking provisions enforced
Comments.
No noir s)54t- - AAVrtio 71, flL'T fvir S ri ai r 1/o.
711 14.4. A Zfr pi- i>iJNgez:rii ers Se ' '—.4i - / 4,64G 2444&.C4
Witslikk 7-441 ,4- ail M-_0111411A344 .2"rItio 4.4 ..(,4.1 _
Reinspect Date Inspec r-Fire ept. � .1[4 / Propert Ow resentati
4_041
Form 4185 Disk STW 2
i i