Loading...
HomeMy WebLinkAboutFP 2006-00348 Material & Test Certificate CONTRACTOR'S MATERIAL&TEST CERTIFICATE FOR ABOVEGROUND PIPING PROCEDURE Upon completion of work,Inspection end tests shall be made by the contractor's rapresentatlw and witnessed by an owner's representative, All defects shell be corrected end system left In service before contractor's personnel finally Neve the job, A certlfl.:ete shell be filled out and signed by both repreeentatives. Copies shell be prepared for approving authorities,owners end contractor. It Is understood the owner's representative's signature in no way preludlces any claim against contractor for Nulty material,poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAMEDATE fiu6 6"/40 E, 642240 et-,S //-/ PROPERTY ADDRESS .5236 Z 64 a- 604‘.ry 6.T. ACCEPTED SY APPROVING AUTHORITY 'SI NAMES Cri g � 3 ADDRESS PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS YES 0 NO EQUIPMENT USED IS APPROVED ES 0 NO IF NO,EXPLAIN DEVIATIONS OHAS P CONTROL VALVESCHARGE ANDFFIRE CARE ANDMAINTENANCEOINSTRUCTED THIS NEW EQAS UIPMENT ❑YES NO IF NO,EXPLAIN INSTRUCTIONS HAVE c OAHU OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS ❑YES 0 NO AND N.PA 13A BEEN LEFT ON PREMISES NLOCATION SUPPLIES.LDOS'LOOS, �y� Vha f , Ai ��+ - ,� 1 OF SYSTEM S�'p L, �/tue MAKE MODELFEAR OF ORIFICE QUANTITY TEMPERATURE MANUFACTURE SIZE RATING 2..006 /5"5-- SPRINKLERS 7-'/� Ori il� ( /r' &aO. �v" l Z /,55— PIPE CONFORMS TO / STANDARD hE ES D NO PIPE AND FITTINGS CONFORM TO / O STANDARD Lt. ❑NO FITTINGS IF NO,EXPLAIN ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST PIPE ALARM -E TypE MAKE MODEL MIN. OR F L. ries,SRo1"reit _511 7 X fig V 33" INDICATOR DRY_YALVE 0.0.0, �� `�E MODEL I SERIAL NO MAKE MODEL SERIAL N0. TIME TOT . WATER AIR TRIP POI ALARM REACHED OPERATED THRU TEST PIPE- SURE PRESSURE AI RE TEST OUTLET PROPERLY DRY PIPE MIN. SEC, PSI PSI /'— PSI MIN. SEC. YES NO OPERATING TEST Without O.O.O. With O.O.D. IF NO,EXP `____"_________` 'MEASURED FROM TIME INSPECTOR'S TEST PIPE IS OPENED. (OVER) SSA 00401 PRINTED IN USA Contractor's Material&Test Certificate i' ; Aboveground Piping 13-10 SPRINKLER SY(AP.-fS OPERATION • • - - •TIC DELECTRIC OHYDRAULIC PIPING SUPERVISED AYES it, • DETECTING MEDIA S '- ED AYES ONO DOES VALVE OPERATE FROM THE MANUAL TRIP ANO/OR RE • •. • STATIONS ❑YES ONO DELUGE& IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUI -- - STING IF NO, •- • PREACTION DYES ii .• VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT MAX •• . ME T MA MODEL SUPERVISION LOSS ALARM OPERATE VALVE RELEASE OPERATE Ru•-- YES NO YES NO MIN, riz. HYDROSTATIC: Hydrostatic tests shell be mode at not less than 200 psi)13.6 bars)for two hours or 50 psi 13.4 bars)above static pressure,n excess of 150 psi(10.2 bars)for two hours. Differential dry-pipe valve clappers shell be left open during test to prevent damage. All aboveground piping leakage shall be stopped. TEST FL SN(NG: Flow the required rate until water is clear as Indicated by no collection of foreign materiel in burlap bags at outlets such as DESCRIPTION hydrants and blow-offs. Flush at flows not less then 400 GPM(1514 L/min)for 4-Inch pipe 600 GPM(2271 L/min)for 5-Inch pipe, 760 GPM(2839 Llmin)for 6-inch P8(34,1000 GPM(3785 L/min)for 8-inch pipe,1500 GPI(15678 L/min)for 10-Inch pipe end 2000 GPM(7570 L/min)for 12-inch pipe. When supply cannot produce stipulated flow rates,obtain maximum available. PNEUMATIC:Establish 40 psi 12.7 bars)air pressure end measure drop which shall not exceed 1.14 psi(0.1 bars)In 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-14 psi(0.)bars)In 24 hours. ALL PIPING HYDROSTATICALLY TESTED jA PSI FOR HRS. IF NO,STATE REASON �� DRY PIPING PNEUMATICALLY TESTED ❑YES ONO J4s[ EQUIPMENT OPERATES PROPERLY ,v i D YES ❑NO !/ READING OF GAGE LDRAINOCATED EA WATER SUPPLY TEST PIPE, RESIDUAL PR ITH VALVE IN TEST PIPE OPEN WIDE TESTS TEST STATIC PRESSURE: PSI J PSI Underground mains and lead In connections to system risers flushed before connection made to sprinkler piping. VERIFIED BY COPY OF THE U FORM NO,a5B DYES ONO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDER• GROUND SPRINKLER PIPING DYES ONO BLANK TESTING NUMBER ED LOCATIONS NUMBER REMOVED GASKETS WEL ED PIPING ❑YES pirQO IFYES..- DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS 010.9,LEVEL AR-3 0 YES [ANO 00 YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS 010.9,LEVEL AR-3 D YES D NO 00 YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED,AND THAT THE INTERNAL DIAMETERS OF YES ONO PIPING ARE NOT PENETRATED HYDRAULIC NAMEPLATE PROVIDED IF NO,EXPLAIN DATA NAMEPLATE YES ONO DATE LEFT INS RVI WITH AL NTrj.LyALVVS'�O EN: REMARKS (I _f/'/'� NAME OF SPRINKLER CO=j•RACTORr /1-7,- -- 6egieo .�Pe'V•UL6)L TESTS WITNESSED BY SIGNATURES F PROPERTY OWNER(51O CO 1A.14 TITLA,�, DATE FOR SPRI CONTR CTOR (SIGNED) TITLE DATE 5 cD t n-e� j o�iE� 'y14/h4l I f/ ?C3 . ADDITIONAL EXPLANA ION AND NOTES e5A BACK (gilts.-toy's Matt-dal& Tcci fCcrtific. for Abovcgraund r'ipLIg