HomeMy WebLinkAboutFP 2007-00043 Material & Test Certificate CONTRACTOR'S MATERIAL&TEST CERTIFICATE FOR ABOVEGROUND PIPING
•
PROCEDURE
Upon completion of work,Inspection and tern shall be made by the contractor's representative and witnessed by an owner's representative. All
defects shall be corrected and system left In service before contractor's personnel finally The the lob.
A owl/late shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners end contractor,
It Is understood the owner's representative's signature In no way prejudices any claim against contractor for faulty material,poor workmanship,
or failure to comply with approving authority's requirements or load ordinances.
PROPER/ AME E 01- & c,-'S
rYSa7
PROPSYARD/ RESS7��`(^! ;
ACCEPTED BY APPROVING AUTH0 0 ( NAMES
CC BILI
ADDRESS
PLANS
INSTALLATION CONFORMS TO ACCEPTED PLANS.. areLIS 0 NO
EQUIPMENT USED IS APPROVED
EYES ONO
IF NO,EXPLAIN DEVIATIONS
HAS PERSON IN CHARGE OF FIRE EQUIPMENT SEEN INSTRUCTED AS TO LOCATION p+I'ES 0 NO
OP CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT
IF NO,EXPLAIN
INSTRUCTIONS pOA Ess OFROPRA !ININSTRUCTIONS AND CARE AND MAINTENANCE CHARTS S El NO
AND HAVE SEEN "mammas
IF NO,EXPLAIN
LOCATIONND CARE A/5)00S.�/L y�� /j�yr �e
OF SYSTEM V�t LV L i/l/ F14,1441 i+e/ CZ,7 A SIN ig/�c3C�1 T
YEAR OF ORIFICE TEMPERATURE
MAKE MODEL OUANTITV
MANUFACTURE RATING
`j'�/e'er £41 ' "TV 22 -. 70v7 r " c3 /,$'-5-a
SPRINKLERS jjllf/C&J , 4S i /33 2vv"/ X. " / .5 LSA "
PIPE CONFORMS TO, / ee-O, STANDARD see YES 0 NO
PIPE AND FITTINGS CONFORM TO r1/f 7' STANDARD j'ES 0 NO
FITTINGS IF NO,EXPLAIN
ALARM DEVICE MAXIMUM TIME 10 OPERATE THROUGH TEST PIPE
ALARM TYPE MAKE MODELzi, MIN. S
VALVE
OR FLOW i/i41"I S A� Sy cin D Y . 3
INDICATOR S W t re
b+ JZ Nv<eYl
DRY VALVE • 0 0.0.
MAKE. MODEL SERIAL NO. MAKE MODEL SERIAL NO.
TIME TO TRIP WATER AIR TRIP POINT TI WATER ALARM
REACHED OPERATED
THRU TEST PIPE' PRESSURE PRESSURE AIR PRESSURE TEST OUTLET'
PROPERLY
DRY PIPE MIN, SEC, PSI PSI PSI MIN. SEC. YES NO
OPERATING
TEST Without
I 0.0.0.
t Wren
O.O.O.
IF NO,EXPLAIN
'MEASURED FROM TIME INSPECTOR'$TEST PIPE IS OPENED.
SSA 00101 PRINTED IN USA (OVERI
Contractor's Material&Teat Certificate for Aboveground Piping
1
13-10 SPRINKLER SYSTFMS
see-- - - -
OPERATION
❑PNEUMATIC ❑ELECTRIC ❑HYDRAULIC
PIPING SUPERVISED ❑YES ONO 'DETECTING MEDIA SUPERVISED ❑YES ONO
DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS OYES ONO
DELUGE Si IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO,EXPLAIN
PREACTION ❑YES 0 NO
VALVES
,A, MAKE MODEL DOES EACH CIRCUIT OPERATE r DOES EACH CIRCUIT MAXIMUM-wen)iji
I/Y\ SUPERVISION LASS ALARM OPERATE VALVE RELEASE OPERATE RELEASE
YES l NO YES NO MIN. SEG 1
HYDROISTATIC: Hydrostatic tests shell be made at not less theni200 psi(13.6 bars)for two hours or 50 psi(3.4 bars)above static
pressure in excess of 150 psI(10.2 bars)for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage.
All aboveground piping leakage shall be stopped.
TEST FL�SHING: Flow the required rate until water is clear as Indicated by no collection of foreign material in burlap bags at outlets such as
DESCRIPTION hydrants and blow-offs. Flush at flows not less than 400 GPM(1514 L/min)for 4-inch pipe,600 GPM(2271 L/man)for 5•inch pipe,
750 GPM(2839 L/min)for 6-inch pipe,1000 GPM 13785 L/min)for 8-inch pipe,1500 GPM(5678 L/min)for 104nch pipe and 2000
GPM(7570 L/min)for 12-Inchipe. When supply cannot produce stipulated flow rates,obtain maximum available.
PNEUMAT C:Establish 40 psi 12.7 bars)air pressure and measure drop which shall not exceed 144 psi(0.1 bars)in 24 hours. Test
pressure tans at normal water level and air pressure and measure air pressure drop which shall not exceed 144 psi(0.1 bars)in 24 hours.
ALL PIPING HYDROSTATICALLY TESTED AT PSI FOR HAS. IF NO,STATE REASON
DRY PIPING PNEUMATICALLY TESTED(j'sy ❑YES ❑NO ,
R
EQUIPMENT OPERATES POPERL !!tt OYES ❑NO 13 •4-•/
DRAIN READING OF GAGE LOCAT N WATER SUPPLY TEST PIPE: RESIDUAL WITH VALVE IN TEST PIPE OPEN WIDE
TESTS TEST STATIC PRESSURE: PSI PSI
Underground mains and le in connections to system risers flushed bef a connection made to sprinkler piping.
VERIFIED BY COPY OF THE U FORM NO,15511 ❑YES ONO OTHER EXPLAIN
I
FLUSHED BY INSTALLER OF UNDER•
GROUND SPRINKLER PIPING Dyes ONO
BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED
GASKETS
WELDED PIPING ❑YES ONO
IF YES...
DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY
WITH THE REQUIREMENTS OF AT LEAST AWS 010.9,LEVEL AR-3 ❑YES ONO
00 YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN
WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3 ❑YES 0 NO
00 YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A
DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE
RETRIEVED,THAT OPENINGS IN PIPING ARE SMOOTH,THAT SLAG AND OTHER
WELDING RESIDUE ARE REMOVED,AND THAT THE INTERNAL DIAMETERS OF
OYES ONO
PIPING ARE NOT PENETRATED
HYDRAULIC NAMEPLATE PROVIDE IF NO,EXPLAIN
DATA
NAMEPLATE YES 0 N
DATE LEFT IN SERVICE WIT ALL C NTROL ES OPEN:
REMARKS ' ` Q
NAME O PRINKLER CONTRACTOR
. atad/ r )re-4 1044� c--'r 6cr- '7 e I
TESTS WITNESSED BY
SIGNATURES FO' PROPERTY OWNER(SIGNED TITLE DATE
1 b.– C 1.4_..t. I -Ftc,f CA-Ctt_ 6611414Q4At I q"S--—t 7
FOR SP .�L_• CONT CTOR(SIGNED) TITLE DATE `
ADDITIONAL EXPLAN•T ON AND NOTES
i
SSA BACK
Contractor's Material&Test Certificate for Aboveground Piping