Loading...
HomeMy WebLinkAbout39 BRAUN 1 NTERTE The Scienee You Build On. Letter of Transmittal 39 Client: Stillwater Area Public Schools Project No: B1602671 Project: Stillwater High School Renovations and Additions Date: December 06,2016 Braun Intertec Corporation 11001 Hampshire Ave. S. Bloomington, MN 55438 To: Kristen Hoheisel Phone: 651-351-3840 Stillwater Area Public Schools Email: hoheiselk@stillwaterschools.org Independent School District#834 1875 Greeley St S Stillwater, MN 55082 Re: Stillwater BLVD N, Oak Park Heights, MN IDocuments Sent Comments Fireproofing Fireproofing#5 ICopy List Jared Olson,BKBM Engineers Jack Bronczyk, Kraus-Anderson Construction Company Daniel Martin, Braun Intertec Corporation Jeff Moore, Kraus-Anderson Construction Company Steven Martin, Braun Intertec Corporation Kristy Casper,Kraus-Anderson Construction Company Aaron Fields, BWBR Architects, Inc. Randy LaFaive, Market&Johnson Michael Smunty, BWBR Architects, Inc. Julie Hultman,City of Oak Park Heights Dustin Phillips, Kraus-Anderson Construction Company Contact Information: Sent By: Nicole Sotolova Email: nsotolova@braunintertec.com Phone: Rev:05/05/2014 Providing engineering and environmental solutions since 1957 Rev.1 Issue: BRAUN, 6.32.4 R 6/23/15 INTERTEC Special Inspection Daily Report City of: Oak Park Heights Page 1 of 1 Report No.: Fireproofing#5 Observation Date: 12/1/2016 Project Name: Stillwater High School&Pony Activity Center Project No.: B1602671 Project Address: Stillwater Blvd. N Braun Intertec PM: D. Martin Client: ISD#834 Client Project No.: Weather: Sunny Temperature: 35 •F que cy Freuen Inspection Coverage (Notes) Periodic Sprayed'fire-resistant materials Did the architect or engineer authorize changes to approved plans? (It yes,list details below) Description and location of work performed: 1)Performed visual and Thickness observations of Cafco 300AC spray applied fireproofing on Beams,Columns,and Angles. Zone 3 2nd level grids E-F,5.5-11.All thickness meet or exceed the thickness requirments supplied by Custom Drywall. No Discrepancies Noted, Thickness requirments Beams 1" Columns 1" Angles 1" 1 Density Sample taken 2)Set up Adhesion/Cohesion test per ASTM E763 on Cafco 300AC spray applied fireproofing on Beams,Columns,and Angles.3 test samples were set up on both 2nd and Roof levels in Zone 10 grids EE-KK,10-16 and H'-L',1-9 and Zone 12 grids EE-KK,25-30 and A*-D*,3*-12* List tests performed: Visual •Are there any discrepancies noted from this day's observations? No •Are there any outstanding discrepancies on this project? No -If yes,see attached Summary Sheet. • Report Discussed with and Given to Contractor? Yes Report Emailed to: Jeff Moore jeff.moore@krausanderson.com 612-790-6711 Jack Bronczyk jack.bronczyk@krausanderson.com 612-812-3972 To the best of our knowledge,work inspected was done in accordance with the approved plans,specifications and applicable workmanship provisions of the current IBC,except as noted above. ix --- Baumann, Troy Signed: I.D.No.: 5067860 S1&52 Providing engineering and environmental solutions since 1957