HomeMy WebLinkAbout42 BRAUN
INTERTEC w}}
The Science You Build On. Letter of Transmittal 42
Client: Stillwater Area Public Schools Project No: 81602671'
Project: Stillwater High School Renovations and Additions
Date: January 20, 2017 Braun Intertec Corporation
11001 Hampshire Ave. S.
Bloomington, MN 55438
To: Kristen Hoheisel Phone: 651-351-3840
Stillwater Area Public Schools Email: hoheiselk@stillwaterschools.org
Independent School District#834
1875 Greeley St S
Stillwater, MN 55082
Re: Stillwater BLVD N, Oak Park Heights, MN
(Documents Sent Comments
Concrete Tests Sets 112& 113(28-Day Break)
Set 114(7-Day Break)
Fireproofing Fireproofing report 8 dated 1110117
'Copy List
Jared Olson, BKBM Engineers Jack Bronczyk, Kraus-Anderson Construction Company
Daniel Martin, Braun Intertec Corporation Jeff Moore, Kraus-Anderson Construction Company
Steven Martin, Braun Intertec Corporation Kristy Casper, Kraus-Anderson Construction Company
Aaron Fields, BWBR Architects, Inc. Randy LaFaive, Market&Johnson
Michael Smunty, BWBR Architects, Inc.
Julie Hultman, City of Oak Park Heights
Dustin Phillips, Kraus-Anderson Construction Company
Contact Information:
Sent By: Sarah Madsen
Email: smadsen@braunintertec.com
Phone:
Rev:05/05/2014 Providing engineering end environmental solutions since 1957
BRAUN Compressive Strength of Concrete Report Date:1/9/2017
g Sample:132619
NTE RTE C p
Test Method:ASTM C39
heSC aTuu lu4Yl Or:..
1826 Buerkie Road Client: Project:
Saint Paul,MN 55110 Stillwater Area Public Schools 81602871
Phone:651-487-3245 Independent School District#8341875 Greeley St S Stillwater High School Renovations and Additions
Stillwater,MN 55082 Stillwater BLVD N
Oak Park Heights,MN
Sample Details
Set#: 112 Technician: Matheson,Kyle Batched:
Specimen Size: 4"X 8" Cast By: Matheson,Kyle Sampled: 08:20 CST
Specimens In Set: 5 Date Cast: 12/09/16 Cast: 08:30 CST
Truck/Ticket#: 874/3958630 Sampled From: Chute Truck Empty:
Contractor: Market and Johnson Placement Method: Buggy Placement Time:
Location
Placement Location Building Interior-Slab on Grade
Location Details: At grids EE to KK.2-16 to 17,FF to KK.2-25 to 26,B"-7.1*to C*-7.1
Sample Location/Notes: At grids EE-16.2
Batch Log Specifications
Supplier: Gemstone Mix Design: SHS5065 Strength: 4000(psi)
Plant: 3 Lakeland,MN Air: Not Required- (%)
On-Site Admixtures: 1.00 Gal HRWRA-High Range Water Reducing Admixture(11 (1")
Field Measurements
Weather: Mostly cloudy/inside Slump(in): 7-1/4(ASTM C143) Plastic Unit Weight:
Air Temperature(F): 50 Concrete Temp(F): 59(ASTM C1064) Air Content: 4.7(ASTM C231)
Load Volume: 11(yd3)
Lab Test Results
Testing Lab:Bloomington,11001 Hampshire Ave S,Bloomington,MN,55438
Specimen Test l Test Field 1 Lab Average Cylinder Cylinder Max Load Strength ` Fracture Break Capping
Number Age Days Date Cure Days Diameter(In) Area(In2) (lbs) (psi) Type Remark Method
112-1 7 12/16/16 3/4 4,00 12.57 75;660 6,020 4 1A N
112-2 28 01/06/17 3/25 400 12.57 99,030 7,880 2 1B N
112-3 28 01/06/17 3/25 4.00 12.57 101,900 8,110 3 1B N
112-4 28 -01/06/17 3(25 - 4.00 12.57 101,150 8,050 3 1B N
112-5 35 H 01/13/17 3/32
Test Age Average Strengths Wei):7 Day-6020,28 Day 8010
Break Remarks Capping Methods
1A The test result is for informational purposes. N:ASTM C1231,Unbonded Caps
1B:The result meets or exceeds the specified compressive strength.
111A e/i*Ns
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
Steve Martin
01/09/2017
Page 1of1
BRAUN Compressive Strength of Concrete Report Date:1/9/2017
h g Sample:132753
I NTE BTEC
Test Method:ASTM C39
Th.s.Tos,awM fire,
1826 Buerkle Road Client: Protect:
Saint Paul,MN 55110 Stillwater Area Public Schools B1602671
Phone:651-487-3245 Independent School District#8341875 Greeley St S Stillwater High School Renovations and Additions
Stillwater,MN 55082 Stillwater BLVD N
Oak Park Heights,MN
Sample Details
Set#: 113 Technician: Singer,Zach Batched:
Specimen Size: 4"X 8" Cast By: Singer,Zach Sampled: 10:45 CST
Specimens In Set: 5 Date Cast: 12/12/16 Cast: 11:00 CST
Truck I Ticket#: 829/03959367 Sampled From: Chute Truck Empty:
Contractor: Market and Johnson - Placement Methods Bucket Placement Time:
Location
Placement Location: Building Exterior-Slab on Grade
Location Details: SOG connecting stoop to interior sog on the SE and SW corner of zone 12 at grids DD.7 to EE-25.1 to 26 and KK.1 to
KK.2-25.1 to 26
Sample Location/Notes: SOG connecting stoop to interior sog on the SW corner of zone 12 at grids 1313.7 to EE-25.1 to 26
Batch Log Specifications
Supplier: Gemstone Mix Design: 5036F Strength: 4500(psi)
Plant: 8 Midway St.Paul,MN Air: 4.5-7.5(%)
On-Site Admixtures: 10.00 Gal Water(6 yd3),24.00 Oz AEA-Air Entraining Admixture(5.5 yd'),
Field Measurements
Weather: Partly sunny Slump(in): 7-1/4(ASTM C143) Plastic Unit Weight:
Alr Temperature(F): 2 Concrete Temp(F): 58(ASTM C1064) Air Content: 5.8(ASTM C231)
Load Volume: 6(yd')_
Lab Test Results
s.
Testing Lab:Bloomington,11001 Hampshire Ave S,Bloomington,MN,55438
Specimen Test Test "Field/Lab Average Cylinder Cylinder Max Load Strength Fracture Break Capping
Number Age Days Date Cure Days.. Diameter(In) Area in' (lbs) (psi) Type Remark Method
113-1 7 12/19/16 1/6 4.01 12.63 45,140 3,570 5 1A N
113-2 28 01/09/17 1/27 4.00 12.57 64,440 5,130 4 1B N
113-3 28 01/09/17 1/27 4.00 12.57 63,920 4 5,090 4 1B N
113-4 28 ' 01/09/17 1/27 4.00 12.57 64,690 5,150 4 1B N
w
113-5 35 H 01/16/17 1/34
Test Age Average Strengths(psi):7 Day-3570,28 Day-5120
Break Remarks Capping Methods
1A:The test result Is for informational purposes. N:ASTM C1231,Unbonded Caps
1B:The result meets or exceeds the specified compressive strength, s
1 \' / 7 \
.N X11 _
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
Steve Martin
01/09/2017
Page 1of1
BRAUN Com ressive Stren th of Concrete Report Date:1/5/2017
1 N T E RT E C Test P g Sample:133930
Method:ASTM C39
teScs-,Yo,,tWd Qn.:
1826 Buerkle Road Client: Project:
Saint Paul,MN 55110 Stillwater Area Public Schools B1602671
Phone:651-487-3245 Independent School District#8341875 Greeley St S Stillwater High School Renovations and Additions
Stillwater,MN 55082 Stillwater BLVD N
Oak Park Heights,MN
Sample Details
Set#: 114 Technician: Singer,Zach Batched:
Specimen Size: 4"X 8" Cast By: Singer,Zach Sampled: 08:10 CST
Specimens in Set: 5 Date Cast: 12/28/16 Cast: 08:25 CST
Truck/Ticket#: 874/03963858 Sampled From: Chute Truck Empty:
Contractor: Market and.Johnson Placement Method: _Buggy Placement Time:
Location
Placement Location: Building Interior-Slab on Grade
Location Details: SOG in zone 2 at grids C.4-D.25-4.5 to 5.5,D.25 to D.6-4.3 to 5.5 and D.6 to E-1.5 to 4.3
Sample Location/Notes: At grids 0.8-2.5
Batch Log Specifications
Supplier: Gemstone Mix Design: SHS5065 Strength: 4000(psi)
Plane 8 Midway St.Paul,MN Air: Not Required- (%)
On-Site Admixtures: None
Field Measurements
Weather: Partly cloudy Slump(in): 6-1/4(ASTM C143) Plastic Unit Weight:
Air Temperature(F): 25 Concrete Temp(F): 65(ASTM C1064) Air Content: 2.9(ASTM C231)
Load Volume: 10(yd')
Lab Test Results
Testing Lab:Bloomington,11001 Hampshire Ave S,Bloomington,MN,55438
Specimen Test Test Field/Lab Average Cylinder Cylinder Max Load Strength Fracture Break Capping
Number Age Days , Date Cure Days Diameter(In) Area(Int) (lbs) (psi) Type Remark Method
114-1 7 01/04/17 1/6 4.00 12.57 59,570 4,740 2 1A N
114-2 28 0• 1/25/17 1/27
114-3 28 01/25/17• 1/27
114-4 28 0• 1/25/17 • 1/27
114=5 35 H 02/01/17 1/34
Test Age Average Strengths(psi):7 Day-4740
Break Remarks Capping Methods
1A:The test result is for informational purposes. N:ASTM C1231 Unbonded Caps
X riN^ 111 \
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
Steve Martin
01/05/2017
Page 1 of 1
BRAUN6.32.4 Rev.1 Issue.6/23/15
INTERTEC
Special Inspection Daily Report
City of: Oak Park Heights Page 1 of 1
Report No.: Fireproofing#8 Observation Date: 1/10/2017
Project Name: Stillwater High School& Pony Activity Center Project No.: B1602671
Project Address: Stillwater Blvd. N Braun Intertec PM: D. Martin
Client: ISD#834 Client Project No.:
Weather: Snow Temperature: 20 •F
Frequency Inspection Coverage (Notes)
Periodic Sprayed fire-resistant materials
Did the architect or engineer authorize changes to approved plans? (If yes,list details below)
Description and location of work performed:
1) Performed visual and Thickness observations of Cafco 300AC spray applied fireproofing on Beams,Columns, Deck and
Angles. Zone 2 Roof level grids C-=C.4, 1-4.5.Ali thickness meet or exceed the thickness requirments supplied by Custom
Drywall. No Discrepancies Noted.
Thickness requirments
Beams 1/2"
Columns 1/2"
Angles 1/2"
Bar-Joist 3/4"
2 Density Sample taken
List tests performed:
Visual
•Are there any discrepancies noted from this day's observations? No
•Are there any outstanding discrepancies on this project? No
- If yes,see attached Summary Sheet.
• Report Discussed with and Given to Contractor? Yes
Report[mailed to:
Jeff Moore jeff.moore@krausanderson.com 612-790-6711
Jack Bronczyk jack.bronczyk@krausanderson.com 612-812-3972
To the best of our knowledge,work inspected was done in accordance with the approved plans,specifications and applicable
workmanship provisions of the current IBC,except as noted above.
.- -�-� Baumann, Troy
Signed: I.D.No.: 5067860 51&52
0 Providing engineering and environmental solutions since 1957