HomeMy WebLinkAbout47 BRAN
INTERTEC
The science You Build On. Letter of Transmittal 47
Client: Stillwater Area Public Schools Project No: B1602671
Project: Stillwater High School Renovations and Additions
Date: May 04, 2017 Braun Intertec Corporation
11001 Hampshire Ave. S.
Bloomington, MN 55438
To: Kristen Hoheisel Phone: 651-351-3840
Stillwater Area Public Schools Email: hoheiselk@stillwaterschools.org
Independent School District#834
1875 Greeley St S
Stillwater, MN 55082
Re: Stillwater BLVD N, Oak Park Heights, MN
Documents Sent 'Comments
Concrete Tests Sets 125-127(7-Day Break)
'Copy List 1
Jared Olson, BKBM Engineers Jack Bronczyk, Kraus-Anderson Construction Company
Daniel Martin, Braun Intertec Corporation Jeff Moore, Kraus-Anderson Construction Company
Steven Martin, Braun Intertec Corporation Laurie Fronk, Kraus-Anderson Construction Company
Aaron Fields, BWBR Architects, Inc. Randy LaFaive, Market&Johnson
Michael Smunty, BWBR Architects, Inc.
Julie Hultman, City of Oak Park Heights
Dustin Phillips, Kraus-Anderson Construction Company
Contact Information:
Sent By: Sarah Madsen
Email: smadsen@braunintertec.corn
Phone:
Rev:05/05/2014 Providing engineering and environmental solutions since 1957
BRAUN Compressive Stren th of Concrete ReportDate:4/28/2017
I NT E RT E C Test P g Sample:142135
Method:ASTM C39
Stat U r..1<,.4 4.1.0o
1826 Buerkle Road Client: Project: High Paul,MN 55110 Stillwater Area Public Schools B1602671
Phone'651-487-3245 1381 North Rice Street Stillwater Hi h School Renovations and Additions
St Paul,MN 55117 Stillwater BLVD N
Oak Park Heights,MN
• Sample Details 1
Set*: 125 Technician: Westberg,Arik Batched: 07:41 CDT
Specimen Size: 4"X 8" Cast By: Westberg,Arik Sampled: 08:10 CDT
Specimens In Set: 5 Date Cast: 04/17/17 Cast: 08:15 CDT
Truck/Ticket#: 574/4015756 Sampled From: Chute Truck Empty: 09:00 CDT
Contractor: Curb Masters inc. Placement Method: Buggy Placement Time: 79(min)
Location
Placement Location: Paving-Sidewalk
Location Details: Sidewalk paving in the NE courtyard.
Sample Location i Notes: NE corner of east sidewalk in courtyard.
BatchSpecif cations
Log
Supplier: Cemstone Mix Design: 3A3268 Strength: 4000(psi)
Plant: 3 Lakeland,MN Air: 4.5-7.5(%)
On-Site Admixtures: None
Field Measurements
Weather: Sunny Slump(in): 3(ASTM C143) Plastic Unit Weight:
Air Temperature(F): 48 Concrete Temp(F): 67(ASTM C1064) Air Content: 8.0(ASTM C231)
Load Volume: 10(yd3)
Lab Test Results
Testing Lab:Bloomington,11001 Hampshire Ave S,Bloomington,MN,55438
Specimen Test Test Field/Lab Average Cylinder Cylinder Max Load Strength Fracture Break Capping
Number Age Days Date Cure Days Diameter(In) Area(In') (lbs) (psi) Type Remark Method
125-1 7 04/24/17 1/6 4.00 12.57 41,930 3,340 5 1A N
125-2 28 05/15/17 1/27 '
125-3 28 05/15/17 1/27
125-4 28 05/15/17 1/27
125-5 35 H 05/22/17 1/34
Test Age Average Strengths(psi):7 Day-3340
Break Remarks Capping Methods
1A:The test result is for informational purposes. N:ASTM C1231,Unbonded Caps
X ,. \A \
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
r- fry
Steve Martin
04/28/2017
Page 1 of 1
O RAU N Compressive Strength of Concrete Report Date:4/28/2017
I NTERTEC Test Method: ASTM C39 Sample:142315
1826 Buerkle Road Client: Project:
Saint Paul,MN 55110 Stillwater Area Public Schools B1602671
Phone 651-487-3245 1381 North Rice Street Stillwater High School Renovations and Additions
St Paul,MN 55117 Stillwater BLVD N
Oak Park Heights,MN
Sample Details
Set#: 126 Technician: Westberg,Ark Batched: 06:25 CDT
Specimen Size: 4"X 8" Cast By: Westberg,Arik Sampled: 07:10 CDT
Specimens In Set: 5 Date Cast: 04/19/17 Cast: 07:15 CDT
Truck 1 Ticket#: 861/4017526 Sampled From: Chute Truck Empty: 07:10 CDT
Contractor: Curb Masters Inc. Placement Method: Buggy Placement Time: 45(min)
Location
Placement Location: Paving-Sidewalk
Location Details: Walkway in NE courtyard.
Sample Location/Notes: SW quadrant of sidewalk.
Batch
Log' 8pecificatlona
Supplier: Gemstone Mix Design: 3A3268 Strength: 3000(psi)
Plant: 3 Lakeland,MN Air: 4.5-7.5(%)
On-Site Admixtures: None
Field Measurements
Weather: Cloudy Slump(In): 4-1/4(ASTM C143) Plastic Unit Weight:
Air Temperature(F): 43 Concrete Temp(F): 66(ASTM C1064) Air Content: 7.5(ASTM C231)
Load Volume: 10(yd3)
Lab Test Results
Testing Lab:Bloomington,11001 Hampshire Ave S,Bloomington,MN,55438
Specimen Test Test Field/Lab Average Cylinder Cylinder Max Load Strength Fracture Break Capping
Number Age Days Date Cure Days Diameter(in) Area(in2) (lbs) (psi) Type Remark Method
126-1 7 04/26/17 1/6 4.00 12.57 45,660 3,630 5 IA N
126-2 28 05/17/17 1/27
126-3 28 05/17/17 1/27
126-4 28 05/17/17 1/27
126-5 35 H 05/24/17 1/34 1
Test Age Average Strengths(psi):7 Day-3630
Break Remarks Capping Methods
1A:The test result is for informational purposes. N:ASTM C1231,Unbonded Caps
/ \ r'Nill
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
Steve Martin
04/28/2017
Page 1 of 1
BRAUN Compressive Strength of Concrete Report Date:4128/2017
I NTE BTEC Test Method:ASTM C39 Sample:142492
A ..�Yon N1111,101
1826 Buerkle Road Client: Project:
Saint Paul,MN 55110 Stillwater Area Public Schools 61802671
Phone:651-487-3245 1381 North Rice Street Stillwater High School Renovations and Additions
St Paul,MN 55117 Stillwater BLVD N
Oak Park Heights,MN
Sample Details
Set#: 127 Technician: Gavin,Nicholas Batched:
Specimen Size: 4"X 8" Cast By: Gavin,Nicholas Sampled: 11:05 CDT
Specimens In Set: 5 Date Cast: 04/20/17 Cast: 11:15 CDT
Truck/Ticket#: 751/4018992 Sampled From: Chute Truck Empty:
Contractor. Curb Masters INC Placement Method: Chute Placement Time:
Location
Placement Location: Building Exterior-Sidewalk
Location Details: Pony Plaza about 10'N of field gates
Sample Location/Notes: Pony Plaza about 10'N of field gates
Batch Log
Specifications
Supplier: Cemstone Mix Design: 3A3268 Strength: 4500(psi)
Plant: 3 Lakeland,MN Air. 4.5-75(%)
On-Site Admixtures: None
Field Measurements
Weather: Cloudy with light rain Slump(In): 4-3/4(ASTM C143) Plastic Unit Weight:
Air Temperature(F): 40 Concrete Temp(F): 68(ASTM C1064) Air Content: 7.4(ASTM C231)
Load Volume: 10(yd3)
•
Lab Test Results
Testing Lab:Bloomington,11001 Hampshire Ave S,Bloomington,MN,55438
Specimen Test Test Field/Lab Average Cylinder Cylinder Max Load - Strength Fracture Break Capping
Number Age Days Date Cure Days Diameter(in) Area(in') (lbs) (psi) Type Remark Method
127-1 7 04/27/17 1/6 4.01 12.63 44,730 3,540 5 1A N
127-2 28 05/18/17 1/27
127-3 28 05/18/17 1/27
127-4 28 05/18/17 1/27
127-5 35 H 05/25/17 1/34
Test Age Average Strengths(psi):7 Day-3640
Break Remarks Capes Methods
1A:The test result is for informational purposes. N:ASTM C1231.Unbonded Caps
/ .7
✓\ 1
TYPE TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
r a'f/l1 .
Steve Martin
04/28/2017
Page 1 of 1