Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2017 AIE Inspection Services Backflow Prevention Test Reports
Please print all information neatly AIE Inspection Services, I nc1 EIVED ',; );r , Backflow Prevention Assembly Test ReportJAN 2 4 2018 Inspected By Store# WM-1861 Company Quality Design & Fire City of Oak Park He.fits Address _3.40 _st.+_W Address 780 Mayhew Lake Rd. NE Inspector Lenny-Bur;$ess—At`t_3 - g ,' - 11-8-17 Oak Park Heights, MN. St Cloud, MN. 56304 Certification/ Manager Phone (320)493-8277 License# 090989-BT " Time 1715 Phone 651-439-7476 Job# 1 H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central Alarm Phone 497-273-4600 Location: Inside '• I Describe location(Please be specific): Located in Riser Room. Usage:Domestic Mfg Model Size Serial# Type: Reduced Pressure Zone 'V Watts 'V 909 3" 179856 Orientation: Horizontal ' Protection: Isolation .r Height off i Meter;Acct# Floor 4' (in/ft) i N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date N/A * Relief ports on RPZ free of continuous discharge? Yes 'V Installed Double Check Valve Assembl Pressure Di)ferenDate Y Ne(15'ck-relief) _ N/A Rebuilt N/A CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVB/SVB J Q C Held at 0 PSID Held at PSID Opened at PSID AIR INLET — Leaked ❑X Closed Tight El Did Not Open ❑ Opened at PSID Leaked El Did Not Open El ❑ Cleaned ❑ Cleaned ❑ Cleaned C Cleaned ❑ Replaced: ❑ Replaced: ❑ Replaced: ❑ Replaced: cw 0 w < — cc Air Inlet PSID Q PSID PSID 7 W PSID Check Valve PSID Closed Tight ❑X Leaked ❑ PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight I)( Leaked C Forward Flow Test Performed: If Performed - Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning,flushing or unclogging of test cocks. Test Kit Make Midwest 'V Model 845 ir Serial # 10060303 'V Last Calibration Date 9-17 X Certification Tag Placed on BFP at Completion of Test n BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636) 398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD, Defiance, MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611-AIE-DIGITAL EDITION 082211 Please print all information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected By Store# WM-1861 Company quality Design&Fire Address 3400 55th St. N.W. Address 780 Mayhew Lake Rd. NE Inspector Lenny Burgess ' Date 11-8-17 Oak Park Heights, MN. St Cloud, MN. 56304 Certification! Manager Phone (320)493-8277 License it 090989-BT ' Time 1730 Phone 651-439-7476 Job# 1H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central w Alarm Phone 497-273-4600 V Location:Inside V Describe location(Please be specific): Located in Riser Room. Usage:Fire Type: Double Detector Check-Bypass � Mfg Model Size" 1# YP Ames � 2000B 3/4" 41196 Orientation: Horizontal 'V Protection: Containment ir Height off Meter/Acct# Floor 4' (in/ft) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date N/A * Relief ports on RPZ free of continuous discharge? 'V Installed Double Check Valve Assembly Pressure DifferenceDate N (15'ck-relief) N/A Rebuilt N/A CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVB/SVB J d_ Held at 0 PSID Held at PSID Opened at PSID AIR INLET Z Leaked Q Closed Tight ❑ Did Not Open 0 Opened at PSID Leaked 0 Did Not Open ❑ ❑ Cleaned ❑ Cleaned 0 Cleaned ❑ Cleaned rn ❑ Replaced: ❑ Replaced: ❑ Replaced: ❑ Replaced: cc w 0 w m cc J Air Inlet PSID z PSID PSID LL PSID Check Valve PSID Closed Tight ❑ Leaked ❑ PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight X Leaked Forward Flow Test Performed: If Performed - Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning,flushing or unclogging of test cocks. Test Kit Make Midwest yr Model 845 1r Serial # 10060303 'V Last Calibration Date 9-17 n Certification Tag Placed on BFP at Completion of Test ❑X BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636)398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD,Defiance,MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611-AIE-DIGITAL EDITION 082211 Please print all information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected 8y __ Store WM-1861 Company Quality Design&Fire Address 3400 55th St.N.W. Address 780 Mayhew Lake Rd.NE Inspector Lenny Burgess Date 11-8-17 Oak Park Heights,MN. St Cloud,MN.56304 Certification/ Manager Phone (320)493_8P77 License#090989-BT Time 1745 Phone 651-439-7476 Job# 1 H565 Cert Exp Date 12-31-2018 Alarm C(1WM Alarm Central w Alarm Phone 497.273-4600 Location:Inside w Describe location(Please be specific):Located in Riser Room. Usage:Fire Type:Double Check Mfg Model Size Serial# Ames 'V 3000SS 8" 137787 0205 Orientation:Horizontal ♦ Protection:Containment v. Floor REDUCED PRESSURE PRINCIPLE ASSEMBLY Date N/A *Relief ports on RPZ free of continuous discharge? 'V Installed Pressure Difference Date Double Check Valve Assembly (1"ck-relief) N/A Rebuilt N/A CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVBISVB J Q E' Held at 0 PSID Held at 2.0 PSID Opened at PSID AIR INLET E Leaked ❑X Closed Tight ® Did Not Open ❑ Opened at PSID Leaked ❑ Did Not Open ❑ ❑ Cleaned ❑ Cleaned 0 Cleaned ❑ Cleaned m ❑ Replaced: ❑ Replaced: ❑ Replaced: 0 Replaced: tr w w2 Air Inlet PSID PSID PSID -,7- I�I PSID Check Valve PSID LL Closed Tight Inf Leaked fl PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight e Leaked Forward Flow Test Performed: If Performed-Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note:Include hose stream demand where applicable Please note it attempted cleaning,gushing or unclogging of test cocks. Test Kit Make Midwest 'V Model 845 Serial# 10060303 'V Last Calibration Date 9-17 ri Certification Tag Placed on BFP at Completion of Test © BFP in Service Inspector's Signature Customer Signature Print Name&Title 1314 Hwy DD,Defiance,MO 63341 (636)398-5288 Fax:(636)8284634 We're fired up Distribution: DIGITAL COPY to AIE,1314 Hwy DD,Defiance,MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0811-AIE-DIGITAL EDITION 082211 Please print neat) AIE Inspection Services , Inc. informationy Backflow Prevention Assembly Test Report Inspected By Store # WM-1861 Company Quality Design & Fire Address 3400 55th St. N.W. Address 780 Mayhew Lake Rd. NE Inspector Lenny Burgess ' Date 11-8-17 Oak Park Heights. MN. St Cloud, MN. 56304 Certifications Manager Phone (320) 493-8277 License tt 090989-BT v Time 1800 Phone 651-439-7476 Job # 1H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central w Alarm Phone 497-273-4600 lir Location: Inside lor Describe location (Please be specific): Located at Back Mop Sink. Usage: Domestic V Mfg Model Size Serial # Type: 'V Watts ' 800M4 3/4" 403973 Orientation: Vertically Up ' Protection: Isolation mr Height off Meter!Acct # Floor 8' (in/ft) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date * Relief ports on RPZ free of continuous discharge? NrInstalled 2-16 Double Check Valve Assembl Pressure Difference Date Y (1st ck-relief) N/A Rebuilt N/A J CHECK VALVE #1 CHECK VALVE #2 RELIEF VALVE PSVB Q 1 Held at PSID Held at PSID Opened at PSID AIR INLET — Leaked ❑ Closed Tight ❑ Did Not Open ❑ Opened at 2.2 PSID Leaked 0 Did Not Open ❑ ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Cleaned Cn ❑ Replaced: ❑ Replaced: ❑ Replaced: ❑ Replaced: LY LE Q 0 — --- Q w 2 — — — -- ----- ---------- c Air Inlet 21 PSID zPSID PSID ------ --_ I PSID Check Valve 2.0 PSID Closed Tight ❑ Leaked ❑ PASS I FAIL No.2 Shutoff Valve Supply Pressure 50 Closed Tight X Leaked `— Forward Flow Test Performed: If Performed - Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning, flushing or unclogging of test cocks. Test Kit Make Midwest ' Model 845 Serial # 10060303 Last Calibration Date 9-17 X Certification Tag Placed on BFP at Completion of Test X BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636) 398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD, Defiance, MO 63341/ Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611 -AIE-DIGITAL EDITION 082211 Please print all information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected By Store# WM-1861 Company Quality Design&Fire Address 3400 55th St.N.W. Address 780 Mayhew Lake Rd.NE Inspector Lenny Burgess I' Date 11-8-17 Oak Park Heights,MN. St Cloud,MN.56304 Certification/ Manager Phone (320)493-8277 Licensed 090989-BT Time 1815 Phone 651-439-7476 Job# 1H565 Cert Exp Date 12-31-2018 Alarm Co.WM Alarm Central., Alamt Phone 497-273-4600 Location:Inside Describe location(Please be specific):Located in Garden Center Valve Room. Usage:Irrigation V T Reduced Pressure Zone Mfg Model Size Serial# Type: Wilkens `v 975RP 2" 037127 Orientation:Horizontal Ay Protection: Isolation Height o6 Meter/Acct# Floor 2' (in/6) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date N/A *Relief ports on RPZ free of continuous discharge?Yes v' Installed Double Check Valve AssemblyPressure Difference Date N/A (1 ck-relief) N/A Rebuilt CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVB/SVB a' Q E Held at 6.8 PSID Held at 0 PSID Opened at 3.0 PSID AIR INLET z Leaked 0 Closed Tight 0 Did Not Open 0 Opened at PSID Leaked ® Did Not Open 0 ❑ Cleaned 0 Cleaned ❑ Cleaned 0 Cleaned u, ❑ Replaced: 0 Replaced: ❑ Replaced: 0 Replaced: rew ap w2 w Air Inlet PSID PSID PSID Z PSID Check Valve PSID a Closed Tight 11 Leaked fl PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight Xe Leaked Forward Flow Test Performed: If Performed-Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note:Include hose stream demand where applicable Please note if attempted cleaning,flushing or unclogging of test cocks. Test Kit Make Midwest Model 845 Serial# 10060303 Last Calibration Date 9-17 7 Certification Tag Placed on BFP at Completion of Test n BFP in Service Inspector's Signature Customer Signature Print Name&Title 1314 Hwy DD,Defiance,MO 63341 (636)398-5288 Fax:(636)828-4634 We're fired up Distribution: DIGITAL COPY to AIE,1314 Hwy DD,Defiance,MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611-AIE-DIGITAL EDITION 082211 Please print all information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected By Store # VVM-1861 Company Quality Design & Fire Address 3400 55th St. N.W. Address 780 Mayhew Lake Rd. NE Inspector Lenny Burgess ' Date 11-8-17 Oak Park Heights, MN. St Cloud, MN. 56304 Certification/ Manager Phone (320) 493-8277 License # 090989-BT 'V Time 1830 Phone 651-439-7476 Job # 1H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central v- Alarm Phone 497-273-4600 lir Location: Inside V Describe location (Please be specific): Located in Deli. Usage: Domestic v Mfg Model Size Serial # Type: 1r Watts IF 008QT 3/4" 00692 Orientation: Vertically Up V Protection: Isolation lor Height off Meter/ Acct # Floor 5' On/ft) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date * Relief ports on RPZ free of continuous discharge? Installed N/A Double Check Valve Assembl Pressure Difference Date y (1st ck-relief) N/A Rebuilt N/A CHECK VALVE #1 CHECK VALVE #2 RELIEF VALVE PVE/SVB J Q �- Held at PSID Held at PSID Opened at PSID AIR INLET z Leaked ❑ Closed Tight D Did Not Open ❑ Opened at_ PSID Leaked 0 Did Not Open ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Cleaned U, n Replaced: ❑ Replaced: (1 Replaced: ❑ Replaced: ccw w < Needs replacement c Air Inlet PSID Q PSID PSID z PSID Check Valve 0 PSID Closed Tight ❑ Leaked ❑ PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight Leaked 111 Forward Flow Test Performed: If Performed - Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning, flushing or unclogging of test cocks. "Needs replacement Test Kit Make Midwest l• Model 845 V Serial # 10060303 1r Last Calibration Date 9-17 X Certification Tag Placed on BFP at Completion of Test X BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636) 398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD, Defiance, MO 63341/ Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611 -AIE -DIGITAL EDITION 082211 Please print all information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected By Store# WM-1861 Company Quality Design&Fire I Address 3400 55th St. N.W. Address 780 Mayhew Lake Rd. NE Inspector Lenny Burgess ' Date 11-8-17 Oak Park Heights, MN. St Cloud, MN. 56304 Certification! Manager Phone (320)493-8277 License# 090989-BT 'V Time 1845 Phone 651-439-7476 Job# 1H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central w Alarm Phone 497-273-4600 1r Location: Inside Describe location(Please be specific): Located in Bakery. Usage: Domestic Mfg Model Size Serial# Type: V' Watts 'V 008QT 3/4" 00936 Orientation: Vertically Up 'V Protection: Isolation Height off Meter!Acct# Floor 5' (in/ft) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date * Relief ports on RPZ free of continuous discharge? v• Installed N/A Double Check Valve Assembly Pressure Difference(1st Ne (15S ck-relief)_ !A Rebuilt N/A CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVB/SVB) J Q C Held at PSID Held at PSID Opened at PSID AIR INLET Z Leaked ❑ Closed Tight ❑ Did Not Open ❑ Opened at PSID Leaked ❑ Did Not Open 0 ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Cleaned co ❑ Replaced: ❑ Replaced: ❑ Replaced: ❑ Replaced: o' w wo - < Needs replacement Air Inlet PSID Q PSID PSID z PSID Check Valve 0 PSID L Closed Tight Q Leaked 11 PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight X Leaked Forward Flow Test Performed: If Performed- Designed Flow Rate: N/A_—GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning,flushing or unclogging of test cocks _ Needs replacement Test Kit Make Midwest ' Model 845 Serial # 10060303 'V Last Calibration Date 9-17 X Certification Tag Placed on BFP at Completion of Test X BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636) 398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD,Defiance,MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611-AIE-DIGITAL EDITION 082211 Pleaseprintall information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected By Store# WM-1861 Company Quality Design&Fire Address 3400 55th St.N.W. Address 780 Mayhew Lake Rd.NE Inspector Lenny Burgess w Date 11-8-17 Oak Park Heights,MN. St Cloud,MN.56304 Certification/ Manager Phone (320)493-8277 License p 090989-BT 'V Time 1900 Phone 651-439-7476 Job# 1H565 Cert Exp Date 12-31-2018 Alarm C0.WM Alarm Central-‘, Alarm Phone 497-273-4600 Location:inside Describe location(Please be specific):Located in Produce Dept. Usage:Domestic Mfg Model Size Serial# TYPe: ' Watts I_008QT 3/4" 03782 Orientation:Vertically Up w Protection: Isolation Height off Meter/Acct# Floor 5' (in/ft) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date N/A Relief ports on RPZ free of continuous discharge? V Installed Double Check Valve Assembl Pressure DifferenceDate y (1s`ck-relief) N//A Rebuilt _,, N�/A,, CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVB1;'vty a E Held at PSID Held at PSID Opened at PSID AIR INLET K Leaked ❑ Closed Tight ❑ Did Not Open 0 Opened at _ PSID Leaked ❑ Did Not Open 0 ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Cleaned 1n ❑ Replaced: ❑ Replaced: ❑ Replaced: ❑ Replaced: Kw w0 Leeds replacement ce • Air Inlet_- PSID i PSID PSID LL r-� PSID Check Valve 0 PSID Closed Tight I I Leaked n PASS FAIL I No.2 Shutoff Valve Supply Pressure 50 Closed Tight X Leaked Forward Flow Test Performed: If Performed-Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning,flushing or unclogging of test cocks. Needs replacement l Test Kit Make Midwest v- Model / 845 Serial# 10060303 Last Calibration Date 9-17 n Certification Tag Placed on BFP at Completion of Test Q BFP in Service Inspector's Signature Customer Signature Print Name&Title 1314 Hwy DD,Defiance,MO 63341 (636)398-5288 Fax:(636)828-4634 We're fired up Distribution: DIGITAL COPY to AIE,1314 Hwy DD,Defiance,MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Repots Rev 0011-Am-DIGITAL EDITION 082211 Please print all/ AIE Inspection Services, Inc. Information neatly Backflow Prevention Assembly Test Report Inspected By Store # WM-1861 Company Quality Design & Fire Address 3400 55th St. N.W. Address 780 Mayhew Lake Rd. NE Inspector Lenny Burgess • Date 11-8-17 Oak Park Heights, MN. St Cloud, MN. 56304 Certification/ Manager Phone (320) 493-8277 License # 090989-BT • Time 1915 Phone 651-439-7476 Job # 1 H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central • Alarm Phone 497-273-4600 • Location: Inside • Describe location (Please be specific): Located in Produce at Culligan Unit. Usage: Domestic • Mfg Model Size Serial # Type: • Watts • 800M4 3/4" 64606 Orientation: Vertically Up • Protection: Isolation Height off Meter) Acct # Floor 5' (in/ft) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date * Relief ports on RPZ free of continuous discharge? • Installed N/A Pressure Difference Date Double Check Valve Assembly (1stck-relief) N/A Rebuilt _ N/A CHECK VALVE #1 CHECK VALVE #2 RELIEF VALVE PVB/SVB J Q E- Held at PSID Held at PSID Opened at PSID AIR INLET Z Leaked D Closed Tight ❑ Did Not Open ❑ Opened at 0 PSID Leaked ❑ Did Not Open ❑X ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Replaced: n Replaced: ❑ Replaced: n Replaced: ixw Q o Q w 2 — -- -- — --------- -- — IY Air Inlet 0 PSID Q PSID PSID ZEl PSID Check Valve PSID Closed Tight C Leaked El PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight X Leaked Forward Flow Test Performed: If Performed - Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning, flushing or unclogging of test cocks. Test Kit Make Midwest • Model 845 • Serial # 10060303 • Last Calibration Date 9-17 X Certification Tag Placed on BFP at Completion of Test X BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636) 398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD, Defiance; MO 63341/ Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611 -AIE-DIGITAL EDITION 082211 Please print all information neatly AIE Inspection Services, Inc. Backflow Prevention Assembly Test Report Inspected By Store# WM-1861 Company Quality Design& Fire Address 3400 5th St. N.W. Address 780 Mayhew Lake Rd. NE Inspector Lenny Burgess IF Date 11-8-17 Oak Park Heights, MN. St Cloud, MN. 56304 Certification/ Manager Phone (320)493-8277 License# 090989-BT ' Time 1945 Phone 651-439-7476 Job# 1 H565 Cert Exp Date 12-31-2018 Alarm Co. WM Alarm Central ' Alarm Phone 497-273-4600 Location: Inside yr Describe location(Please be specific): Located in Meat Dept. Usage: Domestic Nor Mfg Model Size Serial# Type: ' Watts IF 008QT 3/4" 08987 Orientation: VerticallyUp ' Protection: Isolation Height off Meter!Acct# Floor 5' _ _(Int) N/A REDUCED PRESSURE PRINCIPLE ASSEMBLY Date N/A * Relief ports on RPZ free of continuous discharge? ' Installed Double Check Valve Assembl Pressure DifferenceDate y N/(1st ck-relief) N/A Rebuilt N/A CHECK VALVE#1 CHECK VALVE#2 RELIEF VALVE PVB/SVB J Q C Held at PSID Held at PSID Opened at PSID AIR INLET Z Leaked ❑ Closed Tight ❑ Did Not Open ❑ Opened at PSID Leaked ❑ Did Not Open ❑ ❑ Cleaned ❑ Cleaned ❑ Cleaned ❑ Cleaned cn ❑ Replaced: ❑ Replaced: ❑ Replaced: ❑ Replaced: ww w <_ Needs replacement Air Inlet___ PSID z PSID PSID PSID Check Valve 0 ❑PSID Closed Tight ❑ Leaked PASS FAIL ✓ No.2 Shutoff Valve Supply Pressure 50 Closed Tight Ei Leaked Forward Flow Test Performed: If Performed - Designed Flow Rate: N/A GPM Actual Flow Rate: N/A GPM Note: Include hose stream demand where applicable Please note if attempted cleaning,flushing or unclogging of test cocks. Needs replacement Test Kit Make Midwest Nor Model 845 Serial # 10060303 lir Last Calibration Date 9-17 X Certification Tag Placed on BFP at Completion of Test 171 BFP in Service Inspector's Signature Customer Signature Print Name & Title 1314 Hwy DD, Defiance, MO 63341 (636) 398-5288 Fax:(636) 828-4634 We're fired up Distribution: DIGITAL COPY to AIE, 1314 Hwy DD, Defiance. MO 63341/Inspector to work PRINTED COPY to STORE for you! BFP Report Rev 0611-AIE-DIGITAL EDITION 082211