Loading...
HomeMy WebLinkAbout2018-03-30 Ltr to Homeowner Re Non Compliant Stairway CITY OF OAK PARK HEIGHTS of t��a 14168 Oak Park Boulevard No. • P.O.Box 2007 • Oak Park Heights,MN 55082-2007 • Phone:651/439-4439 • Fax:651/439-0574 March 30, 2018 Mr. Gary Howe 13210 56th St. N. Oak Park Heights, MN 55082 Re: Stairway Construction Dear Mr. Howe: I was by your home on March 28th for the purpose of conducting a final re-roofing inspection for Buildtec Contracting (P#2018-00034). While I was there, I noticed the stairway alongside your house, leading to your lower rear yard. A review of the property file does not show that a permit was ever issued for the stairway construction. The stairway is not Code compliant as it lacking a handrail and guards. This is being brought to your attention to notify you that this letter is being placed in your property file that work to the stairway has occurred without a permit and has not been inspected for Code compliance. Additionally, I observed a large exhaust fan in operation at the crank out window at the lower level to the side of these stairs. Kindly contact me to advise to what purpose this exhaust is serving. The City of Oak Park Heights Ordinance has adopted the Minnesota State Building Code (including plumbing) and by its reference the International Residential, Mechanical, Fuel Gas and Fire Code. The adoption of these codes does require inspections to new construction and remodeling projects (ie: siding, windows, additions, etc.). Residential contractors and Plumbers are required by the State of Minnesota to have a State license to perform work within the State of Minnesota. Remodeling work without a permit and subsequent inspection is a violation of City Ordinance and State Law. I encourage you to bring the stairs into Code compliance for safety. I have enclosed the Code for stairway handrails, rise and run and guards for your use. Please give me a call or email me, when you are considering work or repair to verify permit needs, if any. I am always happy to help you verify State contractor licensure as well. Sincerely, PLANING & CODE ENFORCEMENT Juli= ultman Buis , g Official Enclosure Tree City U.S.A. BUILDING PLANNING egress door in accordance with Section R311.2 shall be by a the turn and located 12 inches (305 mm) from the side ramp in accordance with Section R311.8 or a stairway in where the winders are narrower. The 12-inch (305 mm) accordance with Section R311.7. dimension shall be measured from the widest point of the R311.5 Construction. clear stair width at the walking surface of the winder. If winders are adjacent within the flight,the point of the wid- R311.5.1 Attachment. Exterior landings, decks, balco- est clear stair width of the adjacent winders shall be used. nies, stairs and similar facilities shall be positively R311.7.5 Stair treads and risers. Stair treads and risers anchored to the primary structure to resist both vertical shall meet the requirements of this section. For the pur- and lateral forces or shall be designed to be self support- poses of this section all dimensions and dimensioned Sur- ing. Attachment shall not be accomplished by use of toe faces shall be exclusive of carpets,rugs or runners. ' nails or nails subject to withdrawal. R311.6 Hallways.The minimum width of a hallway shall be R311.7.5.1 Risers. The maximum riser height shall be not less than 3 feet(914 mm). 73/4 inches(196 mm). The riser shall be measured verti- cally between leading edges of the adjacent treads. The R311.7 Stairways. greatest riser height within any flight of stairs shall not M R311.7.1 Stairways;general. exceed the smallest by more than 3/8 inch(9.5 mm).Ris- N ers shall be vertical or sloped from the underside of the N R311.7.1.1 Stairways serving dwellings or accessory nosing of the tread above at an angle not more than 30 N structures. All stairways serving a dwelling or acces degrees(0.51 rad)from the vertical.Open risers are per- N sory structure, or any part thereof, shall comply with mitted provided that the opening between treads does not • this section. This shall include exterior stairs from a M dwelling or garage to grade and those stairs serving permit the passage of a 4-inch-diameter (102 mm) M decks,porches,balconies,sun rooms,and similar struc- sphere. M tures. Exception: The opening between adjacent treads is N not limited on stairs with a total rise of 30 inches N Exceptions: (762 aim)or less. N 1. Stairs serving attics or crawl spaces. R311.7.5.2 Treads.The minimum tread depth shall be M2. Stairs that only provide access to plumbing, 10 inches(254 mm).The tread depth shall be measured N mechanical,or electrical equipment. horizontally between the vertical planes of the foremost M M R311.7.1.2 Width. Stairways shall not be less than 36 projection of adjacent treads and at a right angle to the N inches (914 mm) in clear width at all points above the tread's leading edge. The greatest tread depth within M permitted hand-rail height and below the required head- any flight Sof stairs shall not exceed the smallest by N room height. Handrails shall not project more than 4.5 more than 3/8 inch(9.5 mm). M • inches (114 mm) on either side of the stairway and the R311.7.5.2.1 Winder treads.Winder treads shall have M minimum clear width of the stairway at and below the a minimum tread depth of 10 inches(254 mm) mea- ts handrail height,including treads and landings,shall not sured between the vertical planes of the foremost pro- M be less than 311/2 inches (787 mm) where a handrail is jection of adjacent treads at the intersections with the M installed on one side and 27 inches (698 mm) where walldine. Winder treads shall have a minimum tread N handrails are provided on both sides. depth of 6 inches (152 mm) at any point within the M Exception: The width of spiral stairways shall be in clear width of the stair. Within any flight of stairs,the N accordance with Section R311.7.9.1. largest winder tread depth at the walkline shall not M R311.7.2 Headroom. The minimum headroom in all parts exceed the smallest winder tread by more than 3/8 inch Mof the stairway shallnot be less than 6 feet 8 inches(2032 (9.5 mm). Consistently shaped winders at the walkline N shall be allowed within the same flight of stairs as rect- M mm) measured vertically from the sloped line adjoining angular treads and do not have to be within 3/8 inch(9.5 M the tread nosing or from the floor surface of the landing or mm)of the rectangular tread depth. N platform on that portion of the stairway. N p R311.7.5.3 Nosings.The radius of curvature at the nos- N Exceptions: ing shall be no greater than 9/16 inch(14 mm).A nosing M 1. Where the nosings of treads at the side of a flight not less than 3/4 inch (19 mm) but not more than 11/4 M extend under the edge of a floor opening through inches (32 mm) shall be provided on stairways with N which the stair passes, the floor opening shall be solid risers. The greatest nosing projection shall not N allowed to project horizontally into the required exceed the smallest nosing projection by more than 3/8 M headroom a maximum of 43/4 inches(121 mm). inch (9.5 mm) between two stories,including the nos- M 2. The minimum headroom for existing buildings ing at the level of floors and landings.Beveling of nos- N shall be in accordance with Section R305.2.2. ings shall not exceed 1/2 inch(12.7 mm). I R311.7.3 Vertical rise. A flight of stairs shall not have a Exception: A nosing is not required where the tread vertical rise larger than 12 feet (3658 mm) between floor depth is a minimum of 11 inches(279 mm). levels or landings. R311.7.5.4 Exterior wood/plastic composite stair R311.7.4 Walkline. The walkline across winder treads treads. Wood/plastic composite stair treads shall corn- shall be concentric to the curved direction of travel through ply with the provisions of Section R507.3. 112 2015 MINNESOTA RESIDENTIAL CODE BUILDING PLANNING R311.7.6 Landings for stairways. There shall be a floor perimeter dimension of at least 4 inches (1(2 or landing at the top and bottom of each stairway. The mm) and not greater than 61/4 inches (160 mrn) minimum width perpendicular to the direction of travel with a maximum cross section of dimension of shall be no less than the width of the flight served. Land- 2'/4 inches(57 mm).Edges shall have a minimum ings of shapes other than square or rectangular shall be radius of 0.01 inch(0.25 mm). permitted provided the depth at the walk line and the total 2. Type H. Handrails with a perimeter greater than area is not less than that of a quarter circle with a radius 61/4 inches (160 mm) shall have a graspable fin- equal to the required landing width. Where the stairway ger recess area on both sides of the profile. The has a straight run, the minimum depth in the direction of finger recess shall begin within a distance of 3/4 travel shall be not less than 36 inches(914 mm). inch(19 mm)measured vertically from the tallest Exception: A floor or landing is not required at the top portion of the profile and achieve a depth of at of an interior flight of stairs, including stairs in an least 5/16 inch (8 mm) within 7/8 inch (22 nun) enclosed garage, provided a door does not swing over below the widest portion of the profile. This the stairs. required depth shall continue for at least 3/8 inch R311.7.7 Stairway walking surface.The walking surface (10 mm)to a level that is not less than 13/4 inches of treads and landings of stairways shall be sloped no (45 mm) below the tallest portion of the profile. steeper than one unit vertical in 48 inches horizontal (2- The minimum width of the handrail above dr percent slope). recess shall be 11/4 inches(32 mm)to a maximum 8311.7.8 Handrails. Handrails shall be provided on at of 23/4 inches (70 mm). Edges shall have a mini- least one side of each continuous run of treads or flight mum radius of 0.01 inch(0.25 mm). with four or more risers. R311.7.8.4 Exterior wood/plastic composite hand- rails. Wood/plastic composite handrails shall comply R311.7.8.1 Height.Handrail height,measured vertically with the provisions of Section R507.3. from the sloped plane adjoining the tread nosing, or fin- ish surface of ramp slope,shall be not less than 34 inches R311.7.9 illumination. All stairs shall be provided with (864 mm)and not more than 38 inches(965 mm). illumination in accordance with Section R303.6. Exceptions: R311.7.10 Special stairways. Spiral stairways and bulk- head enclosure stairways shall comply with all require- 1. The use of a volute, turnout or starting easing ments of Section R311.7 except as specified below. shall be allowed over the lowest tread. R311.7.10.1 Spiral stairways. Spiral stairways are 2. When handrail fittings or bendings are used to permitted, provided the minimum clear width at and provide continuous transition between flights, below the handrail shall be 26 inches (660 mm) with transitions at winder treads,the transition from each tread having a 71/2-inch(190 mm)minimum tread handrail to guardrail, or used at the start of a depth at 12 inches (914 mm) from the narrower edge. flight, the handrail height at the fittings or All treads shall be identical, and the rise shall be no bendings shall be permitted to exceed the more than 91/2 inches(241 mm).A minimum headroom maximum height. f 6 feet 6 inches(1982 mm)shall be provided. R311.7.8.2 Continuity. Handrails for stairways shall R311.7.10.2 Bulkhead enclosure stairways. Stair- be continuous for the full length of the flight, from a ways serving bulkhead enclosures, not part of the point directly above the top riser of the flight to a point required building egress,providing access from the out- directly above the lowest riser of the flight. Handrail side grade level to the basement shall be exempt from ends shall be returned or shall terminate in newel posts the requirements of Sections R311.3 and R311.7 where or safety terminals. Handrailsadjacent to a wall shall the maximum height from the basement finished floor have a space of not less than 11 /2 inch(38 mm)between level to grade adjacent to the stairway does not exceed the wall and the handrails. 8 feet (2438 mm) and the grade level opening to the Exceptions: stairway is covered by a bulkhead enclosure with 1. Handrails shall be permitted to be interrupted hinged doors or other approved means. by a newel post at the turn. R311.8 Ramps. 2. The use of a volute, turnout, starting easing or R311.8.1 Maximum slope.Ramps shall have a maximum starting newel shall be allowed over the lowest slope of 1 unit vertical in 12 units horizontal (8.3-percent tread. slope). R311.7.8.3 Grip-size.All required handrails shall be of Exception:Where it is technically infeasible to comply one of the following types or provide equivalent grasp- because of site constraints, ramps may have a maxi- ability. mum slope of one unit vertical in eight horizontal (12.5-percent slope). I. Type I. Handrails with a circular cross section shall have an outside diameter of at least 11/4 R311.8.2 Landings required. A minimum 3-foot-by-3- inches (32 mm)and not greater than 2 inches(51 foot(914 mm by 914 mm)landing shall be provided: mm).If the handrail is not circular,it shall have a 1. At the top and bottom of ramps. 2015 MINNESOTA RESIDENTIAL CODE 11 3 BUILDING PLANNING 2. Where doors open onto ramps. guard, shall not allow passage of a sphere 6 3. Where ramps change direction. inches(153 mm)in diameter. 2. Guards on the open side of stairs shall not have R311.8.3 Handrails required.Handrails shall be provided openings which allow passage of a sphere 43/8 on at least one side of all ramps exceeding a slope of one• inches(111 mm)in diameter. unit vertical in 12 units horizontal(8.33-percent slope). R312.1.4 Exterior woodplastic composite guards. R311.8.3.1 Height. Handrail height, measured above Woodplastic composite guards shall comply with the pro- the finished surface of the ramp slope, shall be not less visions of Section R317.4. than 34 inches (864 mm) and not more than 38 inches (965 mm). R312.2 Window fall protection. Window fall protection N** shall be provided in accordance with Sections R312.2.1 and N R311.8.3.2 Grip size.Handrails on ramps shall comply R312.2.2. M with Section R311.7.8.3. R312.2.1 Window sills.In dwelling units,where the low- M R311.8.3.3 Continuity. Handrails where required on est part of the opening of an operable window is located N, ramps shall be continuous for the full length of the more than 72 inches (1829 mm) above the finished grade M ramp.Handrail ends shall be returned or shall terminate or surface below, the lowest part of the window opening M in newel posts or safety terminals. Handrails adjacent shall be a minimum of 36 inches (914 mm) above the fin- N M to a wall shall have a space of not less than 11/2 inches ished floor of the room in which the window is located. N (38 mm)between the wall and the handrails. Operable sections of windows shall not permit openings that allow passage of a 4-inch diameter(102 mm) sphere M where such openings are located within 36 inches (914 M SECTION R312 mm)of the finished floor. M GUARDS AND WINDOW FALL Exceptions:PROTECTION N M N R312.1 Guards.Guards shall be provided in accordance with 1. Windows with openings that will not allow a 4- N Sections R312.1.1 through R312.1.4. inch diameter (102 mm) sphere to pass through N M R312.1.1 Where required. Guards shall be located along the opening when the window is in its largest N M the open sides of floors, stairs, ramps, and landings that opened position. M M are located more than 30 inches(762 mm)measured verti- 2. Openings that are provided with window fall pre- N M cally to the floor or grade below.Insect screening shall not vention devices that comply with ASTM F 2090. N M be considered as a guard. N 3. Windows that are provided with window opening M R312.1.2 Height. Required guards at open-sided walking control devices that comply with Section M surfaces, including stairs, porches, balconies or landings, R312.2.2. N shall be not less than 36 inches (914 mm) high measured 4. Replacement windows. N vertically above the adjacent walking surface, adjacent M fixed seating or the line connecting the leading edges of R312.2.2 Window opening control devices. Window N the treads. opening control devices shall comply with ASTM F 2090. N The window opening control device, after operation to N Exceptions: release the control device allowing the window to fully N 1. Guards on the open sides of stairs shall have a open,shall not reduce the minimum net clear opening area M height not less than 34 inches (864 mm) mea- of the window unit to less than the area required by Sec- N sured vertically from a line connecting the lead- tion R310.1.1. M ing edges of the treads. 2. Where the top of the guard also serves as a hand- SECTION R313 rail on the open sides of stairs, the top of the AUTOMATIC FIRE SPRINKLER SYSTEMS guard shall not be less than 34 inches (864 mm) R313.1 Townhouse automatic fire sprinkler systems. An N and not more than 38 inches (965 mm)measured automatic residential fire sprinkler system shall be installed in N vertically from a line connecting the leading edges of the treads. townhouses. M R312.1.3 Opening limitations.Required guards shall not Exception: An automatic residential fire sprinkler system N have openings from the walking surface to the required shall not be required when additions or alterations are N guard height which allow passage of a sphere 4 inches made to existing townhouses that do not have an auto N (102 mm)in diameter. matic residential fire sprinkler system installed. M Exceptions: R313.1.1 Design and installation. Automatic residential N fire sprinkler systems for townhouses shall be designed M N 1. The triangular openings at the open side of stair, and installed in accordance with IRC Section P2904 or N formed by the riser, tread and bottom rail of a NFPA 13D. M 114 2015 MINNESOTA RESIDENTIAL CODE L • BUILDING PLANNING ing membrane below, draftstopping shall be provided in area of the interior room but not less than 25 square feet(2.3 floor/ceiling assemblies under the following circumstances: m2). 1. Ceiling is suspended under the floor framing. Exception: Openings required for light and/or ventilation 2. Floor framing is constructed of truss-type open-web or shall be permitted to open into a sunroom with thermal members. isolation or a patio cover, provided that there is an open- perforatedable area between the adjoining room and the sunroom or R302.12.1 Materials.Draftstopping materials shall not be patio cover of not less than one-tenth of the floor area of less than 1/2-inch (12.7 mm) gypsum board, 3/8-inch (9.5 the interior room but not less than 20 square feet (2 m2). mm) wood structural panels or other approved materials The minimum openable area to the outdoors shall be based adequately supported.Draftopping shall be installed paral- upon the total floor area being ventilated. lel to the floor framing members unless otherwise R303.3 Bathrooms. Bathrooms, water closet compartments approved by the building official. The integrity of the and other similar rooms shall be provided with aggregate draftstops shall be maintained. glazing area in windows of not less than 3 square feet (0.3 R302.13 Combustible insulation clearance. Combustible m2),one-half of which must be openable. insulation shall be separated a minimum of 3 inches(76 mm) Exception: The glazed areas shall not be required where from recessed luminaires, fan motors and other heat-produc- artificial light and a local exhaust system are provided. ing devices. The minimum local exhaust rates shall be determined in Exception: Where heat-producing devices are listed for accordance with Section M1507. Exhaust air from the lesser clearances, combustible insulation complying with space shall be exhausted directly to the outdoors. the listing requirements shall be separated in accordance , R303.4 Mechanical ventilation. Where the air infiltration with the conditions stipulated in the listing. rate of a dwelling unit is less than 5 air changes per hour Recessed luminaires installed in the building thermal when tested with a blower door at a pressure of 0.2 inch w.c envelope shall meet the requirements of Section N1102.4.4 of (50 Pa)in accordance with Section N1102.4.1.2,the dwelling this code. unit shall be provided with whole-house mechanical ventila- tion in accordance with Section M1507.3. SECTION R303 R303.5 Opening location.Outdoor intake and exhaust open- LIGHT,VENTILATION AND HEATING ings shall be located in accordance with Sections R303.5.1 and R303.5.2. R303.1 Habitable rooms.All habitable rooms shall have an R303.5.1 Intake openings. Mechanical and gravity out aggregate glazing area of not less than 8 percent of the floor door air intake openings shall be located a minimum of 10 area of such rooms.Natural ventilation shall be through win feet (3048 mm) from any hazardous or noxious contami- dows, doors, louvers or other approved openings to the out- nant, such as vents, chimneys, plumbing vents, streets, door air. Such openings shall be provided with ready access alleys,parking lots and loading docks,except as otherwise or shall otherwise be readily controllable by the building specified in this code. Where a source of contaminant is occupants. The minimum openable area to the outdoors shall located within 10 feet (3048 mm) of an intake opening, be 4 percent of the floor area being ventilated. such opening shall be located a minimum of 3 feet (914 Exceptions: mm)below the contaminant source. 1. The glazed areas need not be openable where the opening is not required by Section R310 and a For the purpose of this section,the exhaust from dwell- ing unit toilet rooms,bathrooms and kitchens shall not be whole-house mechanical ventilation system is considered as hazardous or noxious. installed in accordance with Section M1507. R303.5.2 Exhaust openings. Exhaust air shall not be 2. The glazed areas need not be installed in rooms directed onto walkways. where Exception 1 above is satisfied and artificial R303.6 Outside opening protection.Air exhaust and intake light is provided capable of producing an average openings that terminate outdoors shall be protected with cor- illumination of 6 footcandles (65 lux) over the area rosion-resistant screens,louvers or grilles having a minimum of the room at a height of 30 inches(762 mm)above opening size of inch(6 mm)and a maximum opening size the floor level. , inch(13 mm),in any dimension.Openings shall be pro- 3. Use of sunroom and patio covers,as defined in Sec- tected against local weather conditions. Outdoor air exhaust tion R202, shall be permitted for natural ventilation and intake openings shall meet the provisions for exterior if in excess of 40 percent of the exterior sunroom wall opening protectives in accordance with this code. walls are open, or are enclosed only by insect R303.7 Stairway illumination. All interior and exterior screening. stairways shall be provided with a means to illuminate the R303.2 Adjoining rooms. For the purpose of determining stairs, including the landings and treads. Interior stairways light and ventilation requirements,any room shall be consid- shall be provided with an artificial light source located in the ered as a portion of an adjoining room when at least one-half immediate vicinity of each landing of the stairway. For inte- of the area of the common wall is open and unobstructed and rior stairs the artificial light sources shall be capable of illu- provides an opening of not less than one-tenth of the floor minting treads and landings to levels not less than 1 foot- 2015 MINNESOTA RESIDENTIAL CODE 105 1 BUILDING PLANNING candle(11 lux)measured at the center of treads and landings. R304.2 Other rooms. Other habitable rooms shall have a Exterior stairways shall be provided with an artificial light floor area of not less than 70 square feet(6.5 m2). source located in the immediate vicinity of the top landing of Exception:Kitchens. the stairway. Exterior stairways providing access to a base R304.3 Minimum dimensions.Habitable rooms shall not be ment from the outside grade level shall be provided with an less than 7 feet(2134 mm)in any horizontal dimension. s' artificial light source located in the immediate vicinity of the bottom landing of the stairway. Exception: Kitchens. Exception: An artificial light source is not required at the R304.4 Height effect on room area.Portions of a room with top and bottom landing, provided an artificial light source a sloping ceiling measuring less than 5 feet (1524 mm) or a 14 . is located directly over each stairway section. furred ceiling measuring less than 7 feet(2134 mm)from the finished floor to the finished ceiling shall not be considered R303.7.1 Light activation. Where lighting outlets are as contributing to the minimum required habitable area for installed in interior stairways, there shall be a wall switch that room. at each floor level to control the lighting outlet where the stairway has six or more risers. The illumination of exte- 1. rior stairways shall be controlled from inside the dwelling SECTION R305 unit. CEILING HEIGHT > Exception: Lights that are continuously illuminated or R305.1 Minimum height, new buildings. Habitable space, N automatically controlled. hallways, bathrooms, toilet rooms, laundry rooms, and por- N y M R303.8 Required glazed openings. Required glazed open- tions of basements containing these spaces shall have a ceil- N publicy, yarding height of not less than 7 feet (2134 mm). The required rt:', open- ings shall open directly onto a street or alley,ora or court located on the same lot as the building. height shall be measured from the finish floor to the lowest Exceptions: projection from the ceiling. M 1. Required glazed openings may face into a roofed Exceptions: M porch where the porch abuts a street, yard or court 1. For rooms with sloped ceilings,at least 50 percent of N and the longer side of the porch is at least 65 percent the required floor area of the room shall have a ceil M unobstructed and the ceiling height is not less than 7 ing height of at least 7 feet (2134 mm) and no por- r"+ feet(2134 mm). tion of the required floor area may have a ceiling N '= 2. Eave projections shall not be considered as obstruct- height of less than 5 feet(1524 mm). M ing the clear open space of a yard or court. 2. Bathrooms shall have a minimum ceiling height of N 6 feet 8 inches(2032 mm)at the center of the front N 3. Required glazed openings may face into the area clearance area for water closets, bidets, or sinks. N under a deck, balcony, bay or floor cantilever pro- The ceiling height above fixtures shall be such that N vided a clear vertical space at least 36 inches (914 mm)in height is provided. the fixture is capable of being used for its intended M w . purpose. A shower or tub equipped with a shower- :Al R303.8.1 Sunroom additions. Required glazed openings head shall have a minimum ceiling height of 6 feet M shall be permitted to open into sunroom additions or patio g inches (2032 mm) above a minimum area 30 M covers that abut a street, yard or court if in excess of 40 inches (762 mm) by 30 inches (762 mm) at the N percent of the exterior sunroom walls are open, or are showerhead. N °` enclosed only by insect screening, and the ceiling height R305.1.1 Basements, new buildings. Portions of base N of the sunroom is not less than 7 feet(2134 mm). ments that do not contain habitable space,hallways, bath d heating.Requireg.When the winter design tempera- rooms, toilet rooms, and laundry rooms shall have a ture in Table R301.2(1)is below 60°F(16°C),every dwelling ceiling height of not less than 6 feet 8 inches(2032 mm). unit shall be provided with heating facilities capable of main Exception:Beams,girders,ducts,or other obstructions main- ..., a minimum room temperature of 68°F (20°C) at a may project to within 6 feet 4 inches (1931 mm)of the point 3 feet (914 mm) above the floor and 2 feet (610 mm) finished floor. from exterior walls in all habitable rooms at the design tem- perature.The installation of one or more portable space heat- R305.2 Alterations to existing building basements.Altera- , ers shall not be used to achieve compliance with this section. tionst portions f existing basements shall comply with the provisionsof ction. R305.2.1 Minimum ceiling height, existing buildings. SECTION R304 Alterations to existing basements or portions thereof shall MINIMUM ROOM AREAS have a ceiling height of not less than 6 feet 4 inches(1931 R304.1 Minimum area. Every dwelling unit shall have at mm), including beams, girders, ducts, or other obstruc- least one habitable room that shall have not less than 120 tions. square feet(11 m2)of gross floor area. R305.2.1.1 Bathroom plumbing fixture clearance. Bathrooms shall have a minimum ceiling height of 6 2015 MINNESOTA RESIDENTIAL CODE 106 * .,. . ; ri l. . �" - , ai r"' e . 7h ,,; „s ,am i • • O. or .ti ,; 1, _ ' t, ,- .. tA,.t A F *.„'A apt •,..,... � -;� 'tF'� �, ` ... x� `s ,r' '4.G+.i2M \+.' 5" tet} • ik -'k", r<s .r 'ail' "amu x '4 kSos''.i }1. .. «x a ,4 "trb y ,:,.:---,,,,''\.,-::... ,..„:/.7,,,,,,,,,.., r ti .�.. r{ is„- ” , _ r. _ f { moi' 4 _ 5' ,,'. 2� E a�* ',r .''''':,,;,._,t.' i ' I itr t yi::3 , t,.:7.?.....,,..;, , P y��rgw .. y •Fl rrj y .- A ,X,,..5:0,4, ' ,Wit,,, To , . '.'1.;.-11 s,.`