HomeMy WebLinkAbout1999-12-09 BFD Inspection Report Inspection Report Bayport Fire Department• 301 2nd Avenue North • Bayport, MN 55003 • (612) 439-6992 Date TimeProperty Address Phone /2/0f/`l9 /°%, _ 14 .'23 H `i6�h s4, �3o-zl'jg Buildin so eqy ame , „ Correspondence To Occupancy Class '� � Const. Type Const. Year No. of Stories Sq. Ft. Floor No. of Occupancies Inspec. Type Owner Name � /; Address y� / / C��/,,( City e/J/�,.f/ "M/0/2t �4— /35L3 A /L y� ar-- %/7,e State Zip V-Does Not Meet Requirements NV-Appears To Meet Requirements NA-Not Applicable (See Additional Instructions On Back) V NV NA 1. Exterior V ply NA 4. Storage V NV NA 8. Sprinkler Systems ❑ ❑ a. Fire Lanes marked/unobstructed ❑ El d. No combustible storage under El El 1 b. Controls readily accessible ❑ K ❑ b. Address visible unprotected stairways ❑ ❑ c. Valves locked open or ❑ bpi ❑ c. Fire hydrant(s) accessible ❑ ❑ e. Storage maintained 2' below supervised CI X ❑ d. Combustible accumulation(s) ceiling (unsprinklered) ❑ CId. Properly serviced acceptable ❑ igl ❑ f. Storage maintained 18" below ❑ ❑ e. Heads in good condition ❑ tit ❑ e. F.D. lock box present sprinkler heads ❑ ❑ f. Wrench/spare heads present ❑ Ikr ❑ f. F.D. connections visible/good ❑ ❑ g. Aisles maintained - 44" min. condition ❑ pa ❑ h. Rubbish, oily rags, waste 9. Fire Alarm Equipment material property stored ❑ 131 ❑ a. Detectors (smoke, heat) properly 2. Exit Features installed ❑ JX El a. Adequate number of exits 5. Flammable/Comb. Liquids ❑ ❑ cii b. Pull stations properly installed ❑ KT ❑ b. Exits, aisles and corridors ❑ RI ❑ a. Proper quantities ❑ ❑ 0" c. Detectors needed free of obstructions ❑ Igc- ❑ b. Proper storage/dispensing El ❑ d. Properly serviced/maintained El [X LI c. Exits openable from inside ❑ [lj El c. No sources of ignition ❑ 7 El e. Tests/drills conducted ❑ AC ❑ d. Exit hardware present and ❑ Q ❑ d. Adequate ventilation operational 10. Other Fire Protection Equip. CI �y{ ❑ ❑ ❑ e. Proper electrical equipment CI!� e. Exit signs present ❑ 4 a. Standpipes needed ElEl f. Exit illumination adequate 6. Utility, Mechanical, HVAC ❑ CIb. Standpipe/hose in good cond. El ❑ g. Emergency lighting present and El 6 U a. Relief valve present on boilers ❑ ❑ X c. Adequate coverage and water heaters operational _ ❑ d. Hood system-fuel shutoff present In 0 111h. Occupant load posted and 101 Xi ❑ b. Shut off valve present on gas ❑ ❑ e. Properly serviced/maintained maintained appliances ❑ ❑ i. Interior finish acceptable ❑ r ❑ c. Approved piping/connectors 11. Electrical 111 )4 J. Stairway ID present Eland appliances usedp ❑ a. Appliances/fixtures in good ❑ LN ❑ d. Proper venting present and in condition 3. Construction Features good condition El ❑ b. Overcurrent protection present ❑ ( El a. Fire separations present ❑ El e. Combustion air supply present El igi ❑ c. Proper wiring/connections and maintained ❑ I ❑ f. Adequate clearances between CId. Extension cords not used in ❑ y L1 b. Openings in fire walls sealed combustibles and appliances place of fixed wiring CI VI El c. Rated fire doors present and ❑ T— ❑ g. Clean ducts and filters El ® El e. Proper use of wiring and equip. operational (closing/latching) El 4n f. 30" clear access to panels CI7. Fire Extinguishers ❑ d. Vertical openings acceptable provided ❑ ® ❑ a. Readily accessible 4. Storage ❑ El b. Proper number and type r • 12. Miscellaneous ❑ ❑ a. Storage neat and orderly El roM ❑ c. Suitable location ❑ w—❑ a. Proper storage of compressed ❑ ❑ b. No combustible storage ingases ❑ ❑ d. Properly serviced/maintained boiler or mechanical rooms ❑ Q- El b. Interior decorations acceptable ❑ ❑ c. No combustible storage in 8. Sprinkler Systems or flame retardant unprotected attics El ❑ 11 a. Adequate coverage ❑ ❑ c. No smoking provisions enforced Comments. No Cu.o p•ticy toad po<r .z voio Same_ of -IJP C,►tw, t ao( ark . Reinspect Date Inspector.Fire Dept. I Pro.rowner/Representat e Form 4185 Disk STW 2 NOTICE TO THE OWNER, OCCUPANT, LESSEE, OR AGENT OF THE PROPERTY WHOSE ADDRESS IS LISTED ON THE REVERSE SIDE: In accordance with Minnesota Statutes 299F.011,an inspection of your property was conducted for the purpose of fire and life safety. At the time of the inspection, certain conditions were observed which do not meet minimum require- ments of the MN Uniform Fire Code.Those items are checked in the first column, under V. A follow-up inspection will be conducted on or after the date listed on the bottom of the inspection report.The purpose of the follow-up inspection is to determine that any violations or deficiencies observed on the previous inspection have been corrected. Failure to comply with fire prevention requirements is a violation of state statute and/or municipal ordinance.There is a variance procedure provided by the statute. Thank you for your assistance with these fire prevention items. If you have any questions or need additional informa- tion, please feel free to contact the Bayport Fire Department at 439-6992.