Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Development Application - Petroleum Maintenance Information
3101 Spring St. N.E. Mpls., MN 55413 www.zahl- pmc.com End rprises, 11255 @g St. N. lake : Iwo, MN Dennis Lahti Sales ZAHL- PETROLEUM MAlNTENApj Sales, Service, Installation of Petroleum Equipment Since 1952 Phone: 61 2- 331 -8553 Fax: 61 2- 331 -8553 E -mail: vtilltpiaro.d.kftdiet ZAHL- PETROLEUM MAINTENANCE CO. E Milleigirrile104 �J = The Leader in Submersible Technology SUBMERSIBLE TURBINE PUMP $PECIFICATIQNS (Fixed speed models: 113, 3/4, 1 -1/2, and 2 horsepower)* GENERAL • The entire pumping assembly shall have UL listing and shall meet all requirements of UL Standard UL 79. • The pump discharge head and manifold assembly shall be manufactured from ASTM A48 Class 25 gray iron. • The pump shall be available in 1/3, 3/4, 1 1/2, and 2 horsepower sizes and shall be manufactured to the proper length as determined by the tank diameter, type of tank, and bury depth. • An optional variable length telescopic feature shall be provided such that the length of the pump is field adjusted at the job site to fit the specific pump length required. This variable length option shall be available in three variable length ranges, referred to as VL1, VL2 & VL3, where the VL2 model will fit 94% of all known installations. • The pump motor shall have a thermal over-current overload protector with automatic reset. • The pump motor assembly shall be clearly marked with pertinent information including Model, Horsepower, Voltage, Phase, and Manufacturer. • Fixed speed Single-phase pump motors shall be a permanent split phase capacitor, and shall incorporate a 15 ocF capacitor for 113, 3/4, and 1 112 horsepower motors and a 40 ocF capacitor for 2 horsepower motors. • The pump shall be UL listed for blend concentrations of: Standard models: 0% - 15% ethanol or methanol and gasoline 20% MTBE with 80% gasoline 20% ETBE with 80% gasoline 17% TAME with 83% gasoline AG (alcohol /gasoline) motels: 0% 100% ethanol or methanol and gasoline 20% MTBE with 80% gasoline 20% ETBE with 80% gasoline 17% TAME with 83% gasoline • The pumping unit shall not incorporate any flexible diaphragms and all sealing shall be accomplished with 0 -rings or UL recognized gaskets. • The pump shall be rated to operate between —40 °F ( -40 °C) and 104 °F (40 °C) with non - gelled product. • FE Petro Inc. shall manufacture the pump. INSTALLATION AND MAINTENANCE • The pump shall have a two or three wire field connection depending on single or three phase models and an easy access ground wire terminal, and shall incorporate a wire retainer which will accommodate these wires. • The pump shall incorporate a port for line pressure testing that shall be sealed with a 114" NPT pipe plug. • The pump head shall be equipped with a manual pressure relief screw to manually drop line pressure to zero by venting line pressure into storage tank. Purpose of this function is to avoid fuel spraying into dispenser and pump containment sumps during any routine service requiring piping to be opened to atmosphere such as filter replacement or leak detector maintenance. • The pump unit shall have a fully extractable head in order to permit removal of the pump motor assembly without disturbing the discharge piping, product in the pipelines downstream of the check valve, syphoning system with syphon check valve installed, or the electrical wiring. • During the removal of the extractable portion of the pump, product contained in the discharge manifold of the pump shall drain automatically into the storage tank. • The pump will be equipped as standard with a 2 3/4" line check valve. • The line check valve shall be independent of the removable head and shall be easily accessible. • The pump motor shall be interchangeable by horsepower with different manufacturers' products. OPERATION • The pump shall have an air /vapor elimination system that returns air or vapors to the underground storage tank through a tube. • The pump unit shall contain a built -in expansion relief valve that relieves pressure at or above pumping pressure but below 50 psi as standard. Other pressure relief settings required by electronic line leak detection shall be available. • The pump motor shall utilize the product being pumped for lubrication of the motor bearings and for cooling the stator, and this fluid shall discharge into the underground storage tank at the top of the motor. • The pump shall have syphon capability built into the pump as standard. `Note: Some fixed speed model pumps may not be available in certain voltage, frequency, and phase ratings 4805 Voges Road, P.O. Box 139 McFarland, WI 53558 Toll free: (800) 225 -9787 Telephone: (608) 838 -8786 Fax (608) 838 -6433 Fepetro@fepetro.com http:llwww.fepetro.com MEMBER � eilIM RUtAT 10" STPOOI 07/1 5/2002 IW VjjN: OUR UNIQUE VARIABLE IENGTH VARIABtISPIEII OPTIONS 11110;31M 5 r' Since the mid 1950's, FE Petro's parent company, Franklin Electric, has been involved in the design and manufacture of submersible motors for use in pumping motor fuels. Building on this extensive history, FE Petro has contributed innovative product designs for submersible pumps throughout the 1990's. A .......: . ... Our STP's use the FE Petro cooling system. This unique system continually passes over 1 GPM through a fine bronze filter and directly through motor bearings whenever pump is operating. nn OI Sib Ma rketers concerned about fueling times, efficiency, serviceability, reliability and overall product quality find it an easy choice to specify FE Petro. Consider these unique FE Petro fea to res to improve the profitability of your retail operations: ��Y"x''iy} �^.9 • . ° ..ksi'�S4 - �`C�$�!tiiA,T���F.'F".�Y.U�.. x$,.3%4!' . a urerne u te s... a The STP uses FE Petro's proven line check valve. At 2 . i " (70mm) in diameter, this valve reduces pressure loss at high flow rates, resulting in faster fueling times and lower power consumption. 1 ia. Finally, one pump that. fits 94°o of al]. known tank diameters and tank bury depth combinations. Two other model lengths are available to handle installations shorter or longer than this range. The telescoping connection is patented by FE Petro. n e c tin, dBl ilk 'one' sirup' g . P a` out . of .t RIVE li � .` ' �'' • � $ $ � .nom b! FE Petro 60 HZ Submersible Turbine Pumps p Per or nance Chart Pump 2HP Variable Speed option 150 130 °r IIME =IEC:��WAii www-r M } _ _;_.. •i ErANZIEVE i = == = _: -' ma�� C� liffing r L mmEEE 150 0 130 1. 120 iii MI 110 ILL 100 z 90 OM 8 Z 60 j 50 4 40 3D 20 10 _ _ _ ■■■1IIIIIM I = ■ amimEME __�� wwww..lrr��w — 120 - ...'.. w - . , i al, m ® �CC E ■■■■I!■■■•• KEY TO PUMP CURVES: Al STP33 1/3HP STP33 1 ST P 75 3141°1 P 2 2 } STP75 C1 S T P150 1.5HR CZ [2} STP15❑ Di STPH 150 1.5HP DZ 2 STPH 150 ' 110 ■■ $ 0 ■■ il 8° 70 i i 6❑ 5U isminffinmeiguils_ -^ # ^ T. VA- .• ; -_ . I(2) M . m == - w ..� �w�o� w -■-�� IMEMM i ra� = =l mm i l ,..:._... f .:.T__ , T T ww i��M 1 =i = r __ � _ � Y ; �� _ _ € q:3 : T �==� C - is w F ��Ko iimpip= I ���� a. a m izr mWm1 i �� f.�+1 N .._�.. -_ w �EEM �l�. ! —FAINIIIII _ . 4 .a�ra�r ° r w 'fir"*" y� kgl i� lima AIi A� ` " mm® n r�� ° ■ wra E �II=1 : i ISAMiv � r■■■■ ■ ■■■ ■� -N �mE � M AMI =-�■ BENww�rawww�w ELE E EM �M�I�MI�, MW ww�ww w ..., 0 t0 20 3R 40 50 60 76 80 90 100 110 120 130 140 150 160 170 180 190 200 � LTAZI ©MFAWAVi VA.T. � __m l i �►"�� a i . MA C OPERATING RANGE ON 1 STP-VS2 CC■■ M IERTZ �oM =� ∎ = � === OPERATING RANGE ON 2 STP -VS2 NOTES: PERFORMANCE IS BASED ON PUMPING SOLVENT (SG -.'�S) PR ESSURE IS TAKEN AT THE DISCHARGE MANIFOLD OUTLET. SYSTEM CURVES ARE BASED ON 125 FEET OF 2" PIPE, AN AVERAGE NUMBER OF FITTINGS, AND A TYPICAL AUTOMATIC NOZZLE AT THE MIDDLE SETTING. ■cam 1 !4}�� km =E = = I■ WM M SYSTEIIfI CURVES - NUMBER OF NOZZLES OPERATING AT THE SAME TIME ∎/� ��►!1�■=� ��i "al ■k�� �• �,��� M �rs� � m m = =C�9■r� umweim wm= ∎ =■�r� =� =Ea ■i. — Emumm s. a====== �■ . .. ■ ��� ■� ■ © .■■■r, ■■�� �s.� �i■■�■ . D 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 FLOW IN GALLONS PER MINUTE FE Petro 50 HZ Pump Performance Submersible Thu Pumps 2HP Variable Speed option Chart ;.....: 45 1 - , 2 1 4D . 4 MI_ I 7 ... --- , = - :w:: -s. 1 111111111111 W . �,1 T PAC .. 4 �'.��� - I ❑ ur. rAM - 15 - FIE JEF .. # ES Ar A 101 Ill En , 1 MEkeerra Bin 2 ° =1 MEI mmorkvirmisiwgrartmorAto A' 'ILVAILTANNOMPAIIMPI , AF__APIIIIIIN t IiTa►�1■■I►.■Il A Ar FAIIIIVILAVIr MI 'CCiCIW AVM F ■W ■►III2VS i_ WAIIMUMM SIM EIMER I I _ _ itri 0 50 S DD 164 200 250 300 350 400 450 500 550 600 650 700 780 OPERATING RANGE ON 1 STP -VS2 OPERATING RANGE ON 2 STP -VSZ NOTES: PERFORMANCE IS BASED ON PUMPING SOLVENT {SGW.78} PRESSURE IS TAKEN AT THE DISCHARGE MANIFOLD OUTLET. SYSTEM CURVES ARE BASED ON 38.5 METERS OF 2" PIPE, AN AVERAGE NUMBER OF FITTINGS, AND A TYPICAL AUTOMATIC NOZZLE MIDDLE SETTING. AT THE 1. 1.. TOTAL 47 ❑ P - 1 SYSTEM CURVES • NUMBER OF NOZZLES OPERATING • ∎ 1 . - 0 . i � I �� ''.7„-V 'I VI CH -HP 4 AT THE 1 SAME TIME 0 .p° (2 )_ST 0 50 100 150 FLOW 200 IN 250 LITERS 300 350 400 MINUTE $ 450 500 MEM 550 600 � .` ' �'' • � $ $ � .nom b! A standard FE Petro feature. When necessary during maintenance to bleed line pressure to zero a vent screw is provided. By turning this screw, product is diverted back to the tank, dropping line pressure to zero. I�? a,r • • If ever required, the pump can be easily removed from the tank by unthreading three bolts. There is no need to disconnect the syphon system, or remove the leak detector from the system to service the STP. his feature ret ce causing another. NUAI P T 1 ISSUE RELIEF v1c1 :IIIS ar ed into t o su l hole: ;dispenser ecZn . ce:t r o test n se . f he. an .d ut in se p and the en correcting T orie prob em an :�Uax- �a3�:•h�;i����.sr�.� -;i- sir. ��7 .,- L�9.5 ;:r�:�.srae�eca�.w�.��a� • : " '�u.���o�i.� Another unique feature of FE Petro. Provides for a simple connection to underground piping. 1.11 p. o • su .l ; • you with a coz��rr�i�.��.zent to � .p � � . • .ce ` ith internatio all uc t: , n .4(eQ a . a.ss � od .. rid cl� ... . co ze q uality st dards: . • 01 CERTIFIED The FE Petro optional single phase motor control box is available in two configurations. These control boxes are UL listed, CSA Certified or C -UL listed and fit any horsepower FE Petro 4" submersible. Models are available in both 120 volt and 220 volt coils for 50 and 60 Hz power supplies. Please specify. STP -SC: The Smart ControllerTM, using power monitoring technology, offers all the features of our standard STP -CBS control box, plus the following protection and. diagnostics: • Dry Running Protection • Low Voltage Detection • Purnp Motor Failure Detection • Open Circuit Detection • Extended Pump Run Detection • Slave Pump(s) Auto Start Operation • Alternating Pump Control. • Remote Diagnostic Polling Capability STP -CBS: Control Box with wiring terminals, contactor relay and pilot light with lock out toggle switch. One required per pump. Enclosure size is 8 /2" x 5" x 3" (215mmx127mmx76mm). tvo s IFS: Our intake filter screen option utilizes 316 stainless steel to filter particles .009" (.23mm) and larger. It can significantly reduce dispenser filter changes, reducing maintenance costs by 100's of dollars per year. \\\„Av :�:� - '.'.f...: �.��.�fr is '::v� ='�s �yrs t • - Provides constant flow for up to 8 nozzles at a predetermined flow rate set at installation. � dally Pe From January 1, 1996, the EPA requires a maximum flow rate per nozzle of 10 GPM. The STP-VS2 meets this requirement with a one time investment. To comply, the maximum flow rate for one nozzle is adjusted to a maximum of 10 GPM. The STP VS2 will provide a constant flour rate for up to 8 nozzles operating simultaneously. w - neap.s faster ftueli .:• i s du ing th se .... g usiness pe io nda; ustmon 3z eorra a1 tie The Variable Frequency Controller has continuous running diagnostics and displays system conditions on the controller: • Dry Run Protection • Low Incoming Voltage Detection • Pump Motor Failure Detection • Open Circuit Detection • Short Circuit Detection • Thermal Overload In Controller • Controller Capacitors Failing • Remote Diagnostic Polling Capability • STANT ROW uric 1 e nt r0.. ;15. 1.1 et by r ista lation Invest in tivnirrq 33i.xL'.: Fi:.i YCI '�SCS ?'riff POWER SUPPLY OPTIONS: • 60 Hz Applications: Available in 1/3, 3/4, 1 72 and 1/ hp high pressure models in 208 -230 volt, single phase. • 50 Hz Applications: Available in 3/4,1'/2 and 1 72 hp high pressure models in 220 -240 volt, single phase, and 380 -415 volt 3 phase. • 50/60 Hz Applications: 2 hp Variable Speed Option for use with Variable Frequency Controller only. Input 200 -250 volt, 50 or 60 Hz, single or 3 phase. Controller provides 3 phase power to 2 hp variable speed pump motor. PUMP MOTOR: • Centrifugal type, directly interchangeable with most competitive makes. • Maximum liquid viscosity: 70 SSU at 60 F. (15.5° C). • Thermally protected: Automatic thermal overload turns motor off at approximately 205 F (95° C) and resets on at approximately 115' F (45° C). LIQUID COMPATIBILITY: • Standard units compatible with fuel mixtures containing up to 15% ethanol or methanol with gasoline and 20% MTBE, 20% ETBE, or 17 % TAME with gasoline, and diesel fuels. • Alcohol/Gasoline models (designated with AG in model number) are compatible in fuel mixtures containing any combination of ethanol or methanol and gasoline and 20% MTBE, 20 °% ETBE, or 17 °n TAME with gasoline, and diesel fuels. CHECK VALVE: • 2 3 /4" (70mm) diameter constructed of aluminum and steel with fluorocarbon seal. Alcohol gas compatible. PRESSURE RELIEF VALVE: • Standard valve is set to relieve static line pressure at 35-- 50 PSI (2.38 to 3.4 bar), reseals above 30 PSI (2.0 bar). Other settings available. AIR ELIMINATOR: • Returns air to tank with one way check valve to prevent back flour. SEAL ELASTOMERS: All wetted seals on standard units use Vitoif. • Alcohol/Gasoline (AG) models use Viton GFLT ' fluorocarbon seals. SYPHON: • Syphon Primer is venturi type, capable of 26" Hg (66cm) vacuum. • Syphon Check Valve is machined aluminum, field repairable. VARIABLE FREQUENCY CONTROLLER: • Alternating lead pump and master /slave capability. Provides alternating start of the lead pump and "auto ,start" of additional pumps in manifolded pump applications. • Enclosure size is 5 Vs" wide by 10" high by 8'/- " deep (130mm x 254mm x 210mm). APPROVALS AND /OR LISTINGS: • UL, CSA, BASEEFA, TUV, SAA, BKI, INMETRO, TIIS, KHK, FTZU, others pending. QUALITY CERTIFICATION: • FE Petro is an ISO 9001 Certified Manufacturer. R`a�' i s:,'�;al .y �- '•�:Gps,.,.; ..... � :fin ^.• MEMBER w g SEEP,! EQ. HPMENT l�r STPBOO1 :•'idyr^,"�swif •iitinr�rii� Note: The VL2 length can be used in 94% of all known installations. The following information indicates certain installations where a VLF. or VL3 is required: Effective Tank Diameter (ETD) is the combination of any or all of the following: Tank Diameter (to top of. 4" bung) + Manway + Sump Adapter Riser to be determined by bury depth • • R' ' DEPT RISER MIN. Note: Above ground tanks have a minimum riser length of 7". Vi SPECIFY MODEL VL1, VL2 OR 11L3 FROM CHART BELOW MODEL LENGTH= ETD + riser - bottom clearance DETERMINING MODEL LENGTH MODEL LENGTH —B GRADE LEVEL RISER --C EFFECTIVE TANK DIAMETER (ETD) • -iii .... j Vito • 1 1 SUMP ADAPTER MANWAY 5" BOTTOM CLEARANCE (RECOMMENDED) To size pump correctly, the following information is needed: 1 Pump Model/Horsepower? 2. Effective tank (Inside) Diameter? 3. Steel or Fiberglass Tank? 4. If Fiberglass: • Manufacturer? • Single Wall or Double Wall? • Will pump mount on tank or on manway? 5. Bury Depth? 6. Containment Sump? The FE Petro Model Number is designated STRA -B -C, using the critical dimensions shown above, where: A = Pump Horsepower B = Model Length C = Riser Length. Minimum riser length = 7". t3° FE Petro, Inc. 4805 Voges Road P.C. Box 139 d McFarland, WI 53558 (608) 838 -8786 1 --800- 225 -9787 Fax: (608) 838 -6433 w fepetro@fepetro.com a http://www.fepetro.com Rev. 10/99 tlas m 9100 Series Standard, High and Super-High Mechanical Commercial Dispensers • DIESEL GASBOY Fleet Management • Commercial Dispensers • Liquid Transfer Pumps • Service and Support e" Industry standard Defined in more government and industrial specs than any other supplier of fle.et fueling equipment. At Commercial grade constru -ion for longer life Galvanized steel. frame and painted or stainless lower panels offer superior corrosion resistance. intestfation e 11 CA - b Tors incre Field proven flow-through meter im.proves accuracy and performance in contaminated fuel environments. Fleet mana ement TopKATim the industry's only factory mounted integrated fleet syste.m. CFN III PLUS combination fleet management system and P05. Islander 11 card, key, or code activated island fleet manager system. G C. Comprehensive product offering The broade.st rimge of fleet management systems and commercial dispensers for most fueling applications, including gasoline, kerosene, diesel, aviation, E858/185, and Biodiesel fuels. • h Fki sed durabilit eli airu„ (x)rnmerclal tuelmq Lower installation and service costs Footprints are more standardized with a single sized frame for consistent layout of low hose products. Superior graphic options Choose from factory applied paint or stainless lower doors with - fed.lar® or vinyl graphics for a uniform and longer lasting image. uality ma es the differenc DIESEL 4", .1 -: ' o POS and fleet management Dispensers integrate with a complete line of Gasboy or third party fleet control systems. 12 warranty standard Additional 12 - month.s available. Service and support With over 500 Distributors and 150 Authorized Service Contractors, customers are assured of easy access to sales and service anywhere in the world. 1 - Interfaces with POS and Fleet System products. 2 - Factory-installed filter in convenient location. 3 - Improved flow-through meter increases reliability, 4 Vane type pumping unit does not require special priming procedure. 5 - Heavy duty 13-gauge, galvanized 'frame and lower panels. 6 - Fully removable door for easier access and service with plenty of room to work. 7 - Removable side and top sheathing black or customer specified color, or stainless steel side and top panels. 8 - Brightly Ht brand area and display. 9 - Customizable graphic options on lower door. ROW rates Standard, High, and Super -High flo\v models that d.cliver from 15 to 40 GPM. Master, Satellite or Combo The Master /Satellite Combo saves installation expense and extra equipment costs while also saving forecourt space. The front is master, and back is satellite for adjacent master. Meter Four- piston positive displacement flow- through CFT meter- bolsters resistance to fuel contamination with self - cleaning central chamber. Solenoid valve Standardized 1" solenoid valve that may be cleaned or replaced without breaking down pipe work. Cabinet and finish 'Top and sides are black or stainless steel, with lower panels painted white or optional specified color or stainless steel. Po 1 Fleet; Management Interface Pulsei-s converts register revolutions to electrical pulses for connection to Gasboy Fleet Management. Systems or POS. Select. 1:1, 10:1, or 1.00:1 ratios. Electrical Keyt rolTs pulser and mounting kits Includes necessary pulsers, top cabinet: panels, and wiring for factory-installed Gasboy Electrical. 1 <eytrol. For gallons, specify 10:1 kits, and for liters, specify .1.:1 kits. Satellite compatible piping Provides internal piping arid union for connecting to a satellite dispenser. Available on remote dispenser models only. Lighted brand area and display Illuminates product and register areas for brighter day or night fueling. Mechanical display register Veeder- Root.`' mechanical registers with power reset interlock. Displays on 'both sides include gallons or liters to 999.9 and price per gallon or liter to 9.999. Includes non-resettable mechanical totalizer. _ l n .,< and motor Quiet, efficient rotary vane pump with an air- eliminator and sell -- priming built into pump casting. Pumps include an improved. check valve design and field replaceable shaft seal. Continuous duty motor. Refer - t.o table for horsepower. .:Pressure regulator valve Prevents product from leaking from the air elimination vent in aboveground tank installations. Factory installed triter Ten. - micron filter helps ensure product purit y and helps protect critical components from contamination. ,•t rn ai . filter kits Standard. and higli flow bits include adapter element, and. pipe fittings. Specify standard or 1 rosorb element. Ticket printers Print ticket with volume dispensed.. zero start and accumulative r i.odcls. Not available \vitl light or EN options. Hose Optional 31 =1 • Or 1' hardwall hose, variable lengths available. Automatic nozzles Restrict flora N- mrhei tank is lull, 314' or 1'. Internal hose retractor Helps keel: hoses out of the fueling lane. High hose retractor Eases hose handling with enclosed spring return. Keeps hose up and out of the way to reduce wear and run -over damage. Hand crank Ideal for regions where power- outages are likely. Allows dispensing by hand at a rate of .6 liters per stroke. Mechanical reset Where a hand crank. is likely to be used. Vapor recovery Complete vapor recovery kit or special nozzle boot and hanger only. Field installation required.. Voltage' and frequency Standard: 1.1.5VAC /6O l lz. For oth.cr applications & international: 230VAC /60Hz; 23OVAC /5OHz 23OVAC /6O11z with 38OVA.0 motor; 23OVAC /50Hz with 38OVAC motor. Inlet connection Standard and High: 1 -112" (3.8 cm) NPT. Super- High. 2;' (5cm) NPT. Discharge NPT, adjustable to 314" Maximum w rki n g pressure. 50 PS1 Dimensions Units: 53-3/4"H x 28-1/2" W x 18-1/2"D. Packaging: 67"H H x 38"W x 25'D Approvals* UL and cUL; US Weights and Measures for the resale of fuel for applications involving the contracted periodic billing of the fuel dispensed (cardlocks); MC Certificate of Approval for Canada Weights and Measures; and NYCFD. *Pending or in process as of January 10, 2005. Notices Performance flow rates Flow rates shown are maximum test rates, Actual delivery rates will vary depending upon the installation conditions, product: dispensed, added accessories and size of submersible pump. Tested and calibrated for accuracy at any speed or pressure. Safety Warning Failure to follow proper installation instructions may result in property damage, personal injury, or loss of life. Gasboy products must be installed by a qualified installer and used in conformance with all building, fire and environmental codes and other safety requirements applicable to their installation and use, including, but not limited to, NFPA 30, NFPA 3OA, and NFPA 70. This product is only part of a fuel dispensing system. Additional accessories or safety devices may be necessary to meet the applicable codes. Gasboy dispensers shall not be used for the direct fueling of aircraft without filters, separators, and other equipment necessary to ensure product purity. 9153K 9153KTW1 M 9153KTW2 Single Twin Prods Up to 22 (83) Up to 22 (83) Up to 22 (83) zFSr�fev_ N ..r a• (2) 3 /4hp c.d. Gilbarco CFT Gilbarco CFT Gilbarco CFT 1" I.D 1" l.D None None 9152K 9152KTW1 9152KTW2 Up to 15 (57) Up to 15 (57) Up to 15 (57) Up to 22 (83) Up to 22 (83) Up to 22 (83) Gilbarco CFT Gilbarco CFT Gilbarco CFT Gilbarco CFT Gilbarco CFT Gilbarco CFT 1" I.D. 1" I.D. Standard FIow.: 9152KX 9152KXTW1 9152 KXTW2 h Flo 9153KX 9153KXTW 1 9153KXTW2 9140KX Single Single Single Single Up to 15 (57) Up to 15 (57) Up to 15 (57) Upto40 (151) (1) 3 /4hp c.d. (1) 3 /4hp c.d. (2) 3 /4hp c.d. Gilbarco CFT Gilbarco CFT Gilbarco CFT (2) Gilbarco CFT 9215K -Z High 9215KTW -Z High 9215K High 9 852KX, or 9853AX mo del ' GASBOY Single Single Single Up to 49 Up to 40 Up to 40 Satellite dispensers May be paired with standard or high -speed remote dispensers equipped with the satellite piping option. ©2006 Gasboy e 7300 west Friendly Aye. 1 PO Box 22087 Greensboro NC o 27420 -2087 USA Telephone: 1 800 444 5579 ■ Fax: 336 547 5920 ® wwwgasboy.com a sales@gasboycom P -7054 Atlas 9100M Series 04065 Printed in USA Featurfes • High Flow Capacity The primary poppet is held out of the flow stream while the secondary poppet is held normally open to minimize head loss across the valve and to protect the poppet seals from damage and erosion, True 1X" (4 cm) and 2" (5 cm) body sizes ensure, maximum flow. Fire Protection - A fusible link trips the valve dosed at 105° F to shut off fuel supply to the dispenser. Main Poppet Seat Integral to the Top Assembly — Having the main poppet seat as an integral part of the valve top assures a new, clean seating surface is installed each time the top is replaced. This design also ensures that the integrity of the seal between the valve top and bottom is verified during line testing and allows full inspection of the main poppet when the top is removed. Duragarc1 Coat Finish — Provides superior corrosion resistance. .> Reliable Shut -off — A stainless steel main spring, a feflon- coated brass packing nut, and a copper /nickel/ chrome - plated brass stem are designed to prevent tar build-up and corrosion from interfering with poppet operation after long periods of normal service without activation. E C Ca INd 1P161 =D ,. m a T.) cast iron cast iron y I1,a r _ M-19 EiCJ� C6Frler: zinc- plated steel gym: copper-nickel-chrome- plated brass PP3ppet spring: stainless steel Sal: M -19 0-Ring Packing nut: brass, Teflon° - coated Jet and outlet thread: 114" (4 cm) NPT (British threads available) *With black Du ragard E- Coating MI5 Offset Adapleu Low Profile Main Poppet Seat Combinatio Body • The OPW PA15 Offset Adaptor is designed for adjusting misalignment of pipe in dispenser sumps and suction stubs. The PA15 has a low profile feature, and is designed for maximum flow. Ordelling Spec lica e s Thread Size Offset Height Width Part Number in cm in. cm in. cm in. cm PA15 -10 1 38.1 1" 25 21" 57.2 3%" 92.1 PA15 -15 11/2" 38.1 11/2" 38.1 2'/" 57.2 41/2" 104.8 PA15 -20 11/2" 38.1 7' 51 2%" 57.2 4% 117.5 Patented Thermal Relief valve Air Test Port Secondary Poppet :- Fusible (' Link Nickel- Plated, Teflon- Coated Main Stem Main Poppet Integral Test Port — A 'A" (9.5 mm) Test Port allows the piping system to be air- tested without breaking any piping connections. Patented Thermal Relief Valve — Rel ieves excessive pressure build-up caused by thermal expansion of fuel in the dispenser piping system in the event of fire (double- poppet models only). Low-Profile Tops -- Female and Union -top double - poppet valves have a low-profile top to allow upgrading from OPW single- poppet valves without changing existing piping. Multiple Mounting Options — Valves are boss- mounted to stabilizer bars in sumps and pans or mounted to bars embedded in the island with optional U -Bolt kits 1OUBK-015 (not included). Versatile Combination Body (boss mount /U -Bolt mount) models are available to accommodate most mounting applications with one valve style. Underwriters Laboratories — Listed for use with gasoline and 85% and 100% methanol. All OPW 10 Emergency Shut -Off Valves meet requirements of UL STANDARD 842. Compatible with 85% ethanol (E85). Materials Ductile iron Zinc Chromate pew 1 Soles Ermemency Shut-OfT Vve OPW 10 Series Emergency Shut -off Valves are installed on fuel supply fines beneath dispensers at grade -level to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks off at the integral shear groove, activating poppets and shutting off the flow of fuel. Single- poppet models shut off supply flow, while double- poppet models shut off supply as well as prevent release of fuel from the dispenser's internal piping, The base of the Emergency Valve is securely anchored to the concrete dispenser island through a stabilizer bar system within the dispenser sump or pan to ensure proper shearing action. The valve base is secured to the stabilizer bar using a three -point boss mount system or a U -Bolt Kit (not included); 10UBK -015 (1 -112 ") and 1OURK -0200 (2sold separately. Valve inlet (bottom) connections are female pipe threads and outlet (top) connections are available with female threads, male threads or a union fitting. Other options include suction system models with a normally closed secondary poppet which maintains prime, and models with external threads on the inlet body which connect to secondary containment systems. opw Environmental Systems ©PUN ` OS st al er Bert The OPW 10S Stabilizer Bar Assembly is used in installations where no valve mounting system exists. When properly imbedded into the island concrete, 1OS holds the OPW 10 Series valves rigidly in place to assure proper shearing action. The 105 assembly includes all necessary installation hardware. Part # 105 -4770 regij 111 C i eft Refer to Dispenser Directory 11 7 YW � F. F C , The Large Mouth series dispenser sump modular design provides versatility and ease of installation. There are six polyethylene bases in three lengths and two depths. These bases have a large 22" wide by 24 ", 36" or 48" long openings, easing the installation of entry boots and piping connections. The ribbed riser can be cut down in 3" increments in the field to achieve proper pipe slopes with respect to grade. The bases can also be Fiberglass Encapsulated (FE series) for high water or other harsh environments. A variety of Large Mouth Tops (LMT's) are available to match nearly every dispenser model. The lids are corrosion resistant painted steel to which shear valves and dispenser frames are mounted. a 1_ at . $ e Medium Model ISArr Bar Kit , ctsit, Ynt 414 a - 4 00' Ktt LMM -1710 044 LMM-2010 .10 LMM - 2313 -T LMM -2409 LMM -2518 LMM -2811 LMM -2915 LMM - 3617 -36 28" LMM -3617 LMM -4018 Ad III go r LM ills -4111 6.00 28" 28" 28" LMD -4018 LMD -4111 LMM -4115 28" LMD -4115 20.50" 1 0.00" 23.00" 1 2.00" 23.75" 24.75" zn 28.50" 9.00" 17.75" 11.00" Atif '7141 29.75" 15.75" it Y . � -s, i3 36.00" 17,25" 36.00" 39.75" 26" 17.25" i s me r 17.75" 41.50" 11.00" 43" 41.50" 15.75" Medium and Deep Model numbers listed include base and top, stabilizer bar kits, (SBK) sold separately. 22 1 1 SBK-2 SBK -2 SBK -25 SBK -2 SBK -3 SBK -25 SBK -3 SBK -3 SBK -3 53K -3 48" SBK-25 15.5" If 1 1 2 r �� :E, . • �� ti �: FGA'.':: �.'c:r •tczr Metal Fabricators MEMBER 0 EUM EQUIPMENT INS' ,,41, . 411" i. ....,....1.k.m„:..,„„ •'�. °'':4 t chi - } s •�-= '' has r_ c, r f Morgan Brothers Is The Name For uick Response To All Your Fabricated Metal Needs Company Mission Statement • While others only say what they can do ... we deliver. Our reputa- tion for quality encompasses over 85 years of experience in sheet metal fabrication. For the past 40 years, we have manufactured permanent steel island forms and curb facia that are constructed to the highest quality standards in the industry. This has led to our reputation as the oldest, best qualified and most experienced manufacturer in the country. Permanent Steel Concrete Fascia The choice of permanent steel fascia, over the traditional job -site fabrication of temporary wooden forms, offers you many advan- tages. It is effective where curbing or costly equipment and structures are exposed to damaging vehicu- lar traffic. It becomes a permanent part of the structure as well as protecting and holding concrete in place. Rounded upper edges pre- vent damage to vehicle tires. STEEL ISLAND FORMS Service Stations Cashier & Guard Booths • Drive-In Banks � 33 ,.ham STEEL BASE FORM FACIA Time Saving - All fabrica- tions are custom built to your specifications and delivered to the job -site ready to put in place, eliminating costly job -site con- struction expenses. Because the steel curb fascia becomes a per- manent part of the project, the need for hand finishing for appear- ance, that is required for tempor- ary wooden forms, is totally elimi- nated thus resulting in additional cost savings. ® Quality and Experience - At Morgan Brothers these two factors go hand in hand, giving us the edge over our competitors. Quality assurance has been a key element in our production capa- bility. With this as our foundation, we have developed a broad base of experience that guarantees a product you can count on. Sign Pole Bases • Light Pole Bases • Pedestal Bases. for Fleet Fuel Pumps Consider These Additional Benefits Customized Service - There are numerous concrete curbing applications for permanent steel fascia. Many of these require. special considerations and unique features. Our professional engi- neering staff, with years of quali- fied experience, can review your specifications and make sugges- tions to help improve your end product and cost efficiency. Turnaround Time - Our goal is to achieve the fastest turn- around on orders in the industry. Our Three Step Approach to Fast Turnaround: 1. We stock a large assort- ment of finished products ready for immediate shipment. 2. We offer in -house custom- ized engineering service. 3. We utilize the most efficient carriers servicing your area. : ry '''' 110 ry e ,55 ii!.! ,..!!!! STEEL CURB FACIA *Shopping Center Sidewalks 0 Walkways Around Freestanding Buildings Pole, Post and Wall Protectors We offer a large list of pro ucts for a wide v ri S r if needs • Curbing/Sidewalk Permanent Steel Fascia • Catchment Boxes for " MPDs • Permanent Steel Dike 14E Curbing • Pedestals for Commercial Pumps, Trash Cans, etc. • Pipe Guards • Pole /Column Base Permanent Steel Forms • Service Island Permanent Steel Forms • We are continually adding new products. co DISPENSM1 ; e4r k4,"1,1/4151- mciRtv, z.t.t MORGAN' 12 GA. c.tr-L-pr A.mri t„ FORM 14. s CONCRETE CUM COWPACTED SAND OR GRAM, SUPPLY LINE Tivuorial iniml 11SLAN* SECTAON ELEVATION SH3H1OHEi NVDON 006P LV9 PgL XVd OVST COOZ/OC/P0 The Morgan Brothers Advantage: Quick Response, On Time Deliveries And Customer Service We treat each order with personal attention and detailed customized service. We take pride in the fact that our reputation has been built by our ability to fill orders quickly, with quality and cost effectiveness. Morgan Brothers have been approved by most major oil companies throughout the United States. 14€ 1 Tenth Avenue • Beaver Falls, PA 15010 • 412- 843 -7485 • 1 -800- 842 -0369 • FAX 412- 847 -4900 Y � 4 TopKAT is available factory- mounted on a Gasboy 9800A or Tokheim 2600A Series electronic dispenser, or with a mounting kit for an ASTRA dispenser pedestal. The optional TopKAT pedestal is required for use with mechanical dispensers or remote Gasboy 9800A, Tokheim 2600A, or ASTRA dispensers. TOPKAT FUEL MANAGEMENT SYSTEM From the smallest site to large sites, TopKAT provides sophisticated fuel control in an economical, easy-to-use configuration. For All Sites Use either the smart key reader or the keypad, or a combination of both, to initiate fueling transactions. Vehicle, employee, and department information is maintained in the system memory, so it can be easily changed at any time. An optional PCMCIA card provides a simple and reliable means for backing up and restoring system files. For Small Sites Order TopKAT in a "plug if play" configuration factory-mounted directly on a Gasboy / Tokheim electronic fleet dispenser. Add the optional built -in report printer to receive cumulative vehicle, employee, department, and MPG reports right at the fueling island. The result is a completely self - contained fuel dispensing system without having to run any special wiring! Or, with the optional interface board and pedestal mount, you can control up to two existing or new mechanical hoses. For Large Sites TopKAT handles up to 2000 vehicles and 4000 employees. Using the TINet local area network feature, you can control up to eight Gasboy or Tokheim electronic fleet dispensers from one TopKAT. For sites with multiple fueling islands, TINet allows you to link up to eight TopKATs together for common control and reporting. Optional PC/TopKAT Windows software allows you to communicate with an unlimited number of sites, automatically poll transactions, and customize your own reports. Learn more about how TopKAT can handle your fuel control requirements by contacting Gasboy International or your local Gasboy distributor. :A ... VIM Huard! r E SOFTWARE FEATURES ACCESS METHODS (owner- configured) • Vehicle key, vehicle code entered via keypad, or both • With key or code, you can have an optional id field entered via keypad (e.g.; employee #) SYSTEM PARAMETERS • Handles up to 2000 vehicles • Handles up to 4000 employees* • Stores up to 1 650 transactions • Allows entry /editing of system files via keypad and display, or remotely via terminal/PC = Includes TiNet feature - Networks up to eight TopKATs at the same site (1 master/7 satellites) - Allows individual TopKATs to be configured as a master or satellite at start-up - Provides central reporting and database maintenance from the master TopKAT - Reduces need for report printer, PCMCIA, and modem options to the master TopKAT *Note: Employee # is manually entered via keypad; may instead be set up for accounts, jobs, etc.) SYSTEM CONTROLS • Key - encoded unique system ID • Vehicle or employee PIN • Vehicle and employee lockout • Fuel type restriction by vehicle • Fill limit per transaction by vehicle • Maximum fuelings per day by vehicle • Odometer entries checked against last odometer stored on key for reasonability • Manager password protection KEY TYPES • Vehicle* - references vehicle look -up file, prompts for employee file number (blocks of pre - e ncoded vehicle keys may be ordered, or encode at TopKAT) • Supervisor - prompts for vehicle and employee file numbers • Delivery - prompts for inventory delivery amount, adds to inventory • Dipstick - prompts for dipstick reading; creates dipstick transaction • Manager - allows access to reports, file editing, diagnostics, and back -up & restore • Report - allows access to reports only "Note: vehicle code entry via the keypad may be used in place of a vehicle key if desired TRANSACTION DATA RECORDED • Site number • Transaction number • Vehicle key number • Vehicle number • Vehicle department/account number • Employee number • Employee department number • Pump, product, & tank numbers Date and time • Transaction quantity • Vehicle cumulative quantity Gasboy International, Inc. P.O. Box 309 Lansdale, PA 19446 -0309 Phone: 1.215.855.4631 Fax: 1.215.855.0341 www.gasboy.com e -mail: sales@gasboy.com Africa Fax: 20.2.590.0223 Canada Fax: 1.613.475.11 45 Germany Fax: 49.89.189.53399 • Employee cumulative quantity • Odometer • Miles/Kilometers between fuelings • Error code SYSTEM REPORTS • Department/Account Vehicle Report - Reports vehicle, department or account, and grand total fuel usage, last odometer or hour meter, distance (miles /kilometers) or hours traveled, and fuel efficiency (MPG, HPG, L1100KM, LPH, KM /L, or HPL) for current time period • Vehicle Report - Lists vehicle file data plus beginning and ending odometers; maximum and current fuelings per day; cumulative fuelings and quantity per current time period • Department Employee Report - Reports employee and department fuel usage for current time period • Employee Report - Lists employee and department numbers; lockout status; PIN; cumulative fuelings and quantity per current time period • inventory Report - Lists tank number, product code, current quantity, last delivery amount and date • Pump Report - Lists pump and tank numbers, product code, cumulative pump totalizer, and reset date • Lockout Reports - Lists locked out vehicles and employees * System Configuration Report Prints system parameters • Date and Time Report - Prints current date and time HARDWARE FEATURES DIMENSIONS • 15 "w x 10 "h x 17 *d (38 cm x 25 cm x 43 cm) • Optional Pedestal (C07095): 50'h (127 cm) with triangular post and 16' x 16" (41 cm x 41 cm) base POWER & ENVIRONMENTAL REQUIREMENTS =135VAC±10 %, 47-63 hz.; optional 230VAC • -30 °C to 50 °C; 95% relative humidity, non - condensing PUMP CONTROL • Single System - Up to eight Gasboy 9800, Tokheim 2600, or ASTRA hoses - Or up to two mechanical dispenser hoses with optional interface - Up to 1000:1 pulse resolution • Master /Satellite Configuration (One master TopKAT wl up to seven satellite TopKATs) - Up to eight Gasboy 9800, Tokheim 2600, or ASTRA hoses - always controlled by master TopKAT. - Up to 2 mechanical dispenser hoses per master or satellite TopKAT; each with Latin America Fax: 1.215.361.5532 Middle East Fax: 31.497.684072 Singapore Fax: 65.289.0756 South Africa Fax: 27.114.621.942 optional interface (max. 16 w/ master having mechanical hoses or max. 14 w/ master having electronic hoses). DATA ENTRY MW INSTRUCTIONS • 2 line x 20 character, backlit LCD • 4x4 weather -proof membrane keypad with audible feedback • Read /write key receptacle REMOTE COMMUNICATION • RS2321RS422 ports are provided for communication with remote terminal, printer, modem, or PC. Number of ports depends upon configuration due to j-box wiring limitations. • One 9800A/2600A Series (pump- mounted) - One RS232/RS422 port (only RS422 when internal modem is used) plus one optional internal modem port • Single ASTRA or Mechanical Interface One RS2321RS422 port, plus second RS232/RS422 port or optional internal modem port • Master /Satellite TopKAT Configurations -Wrth master pump - mounted; one RS422 port or optional internal modem port - With master pedestal - mounted; one RS232/RS422 port, plus second RS2321RS422 port or optional internal modem port HARDWARE OPTIONS • Internal 168 CPS thermal report printer • Internal 2400 or 9600 baud phone modems • PCMCIA card for data back -up and restore • Smart keys (individual blank keys or packages of 50 pre - encoded keys with consecutive key numbers) PCITOPKAT SOFTWARE Optional Windows -based software provides an interactive link between your PC and your TopKAT site(s) - Site communication - Automatic polling of fueling transactions - Custom reporting of stored transactions ACSII file for export to your favorite program LL WARNING Failure to follow these instructions may result in property damage, personal injury or loss of life. Gasboy products must be installed by a qualified installer and used in conformance with all building, fire and environmental codes and other safety requirements applicable to their installation and use, including, but not limited to, NFPA 30, NFPA 30A and NFPA 70. This product is only part of a fuel dispensing system and additional equipment and accessories, such as, but not limited to, breakaway connectors, shear valves, pressure regulators and other safety devices may be necessary to meet the applicable codes. Qualified installers shall be familiar v th fuel system installations under the above stated building, fire and environmental codes and other safety requirements required for the particular type of installation. Gasboy dispensers shall not be used for the direct fueling of aircraft without flters, separators and other equipment necessary to ensure product purity. All sales subject to Gasboy standard warranty. - 25Y7 © 2000 Gasboy International, Inc. Printed in U.S.A. Bulletin No. SLTK 4/01 Pressure /Suction Prod?1ct ipin XP- 100 -SC -250 XP- 1O0 -SC -500 XP- 100 -SC -2500 tl OO 5250, XP- 150 --SC -100 XP 150 SC 1.50" Secondary XP-150-SC-500 Contained XP- 150 -SC -1800 Do' XP- 200 -SC -100 XP- 200 -SC -200 XP- 200 -SC -350 XP- 2O0 -SC -700 1.00" Secondary Contained 2.00" Secondary Contained F L� �.}7J'G'�'a:�.;•Y r,.y�'° te •ri.67J- { `Sti1.".vY.$.,Yk4L}IC3:SYL. a� ' i XP- 175 -SC -100 XP 175 - SC - 250 1.75" Secondary XP- 175 -SC -500 Contained XP- 175 -SC -1200 -map 1 250 500 2,500 100 Small 250 Small 500 Small 1,800 Std. Cc. 9,, $.9?.4'•57:i{'�` .°;L= :- '�".tY. �i - w:. 100 Small 250 Small 500 Small 1,200 Std. 100 200 350 700 Small Small Std. Master Master Master 5. Mast. 404 516 1,551 346 429 566 1,416 632 742 907 1,490 183 234 704 157 194 257 642 356 162 454 206 616 279 1,206 547 1 : f 5, x�2�.'•y7 r aYd Mil 287 337 411 676 SY� 4 The 1" size of APT piping can be used in both pressure and suction applications, and are ideal for providing remote feed and fill for heaters, boilers and emergency generators. The 1- 112 ", 1 -3/4" and 2" sizes of APT product piping can be used in both pressure and suction applications, and are ideal for underground service station fuel delivery systems. The D- series piping is a single wall direct bury piping, while the SC- series piping provides additional environmental security as a secondary contained direct bury pipe. Both feature controlled flexibility, even in low temperatures, permitting fast, easy installation. R °EEL SIZi ' i' jj 5 �' jjjj t om: M1 s. .. �.. -..r' h-F --� ^ -• rs Small Standard f ' �� e (� Master 84x24x64.5 ti 91 x33 LL l „,„" 231.1 x83.8x 187.9 Do not store piping in direct sunlight 213.3 x 60.9 x 163.8 US LISTED 1 I.D. PRIM ARY LAYER APT PRESSURE /SUCTION PIPE XP-1 00—D n XP— 150 —D XP— 175 —D RigaiM XP-200—D 7?! Q.D. PRIMARY —, LAYER >ti rS �r 3ft•: 1.000 s S ' l s •v r f � s � 1.400 1.650 rd R i'•'i7< f�• rS s i •4 a;' � � c�Z +[6A �a�rw�'c'.".. 2.040 xtKi- •T7}c p t �y, 1.270 1.700 Ip 1.950 i •� r- ..r : Ir MOLL 2.450 T'! •f •�• 7 z ^rs r } :s N/A � ilii3 =l1 ",1 N/A Q.D. SC JACKET NIA r ylrr wc� SV N/A 1424i e•� ti Q.D. SCUFF GUARD s - ♦ •.,�.. to 5 P E� [ •.sue .�' � r 3 7 •R t . . M11 y =p � t t. l� �r 4y�m EP��Pa.r� N/A ,rr x l7 4 S k ,°S NIA t N/A S N/A "3 _C 36.00" x • � e 3 ic. 'r• .3-• .� . k�.F� � x 36.00" 36.00" •r <a �i. 1�+�.o L;� •Y�. 36.00" k4 2 p' A f7� • } iin ❑��]1�y r • - � '.•V' �, s 'r ik f j' . 1 Y•. ;. � �1 F 1 i � r �h ( '� v ! = ��t�• l e f / +�' ✓ f + Y �3 �,, i + l ►�1 + {�+ i;P+p:2�P :�:•:•: \ C -�� {±7 .i• • � ` . 5 i+ 1 1 i!{ r. .�� }' i1 1 {44 1 •":4,T..'� %:• ~7 ti;� . ��ii '• �.�•:�;: �:•� �j� - r.'. 11! 1t _�'J�JY .tip. :��, ��'� J„. • t ~ ``��'i�� _ +ilfll � • _ - :�R�I + f;kll '- r- ��� l iii {e ��'f�.`�:�.r.�', ��� rC`� 111 :Y'•: o � �i'.�.', . F , . 11 1 .�� 1 5 t � •, - 'L.�f •�_ ..• l+• � it l`'`` '� _._..•t` l�a��i• ••�•.�rii',- �•��.. ■ e± fSIRSI SI NSO I .{. i'lyl�1R I S 5ur _VII i I i { WI • 0 Y 0 0 f ti; 31 t.Sf MI I • 3 MA 11 31 A a s'1 • X01 )weed- e . �►. k i .. V Q� �r I f t < <► ,1`` q „rr� i ry r . PS ' r it � `' � � ■y��g r4 k1 ��`. ;' g000vagqiwirrp. 00004* ,,,t-t0.044w .vig+Apoaay. tocRiiiNoilloidgiaggagogiAlibifiEW Z ' }5".'r 1,- fits::;,; �_��?'�+.' ; ►ii►1 �c,� � ' 1S,I rrt + _ ��� .i C r p •per `ti �^� � C , d . ;.�.��f i'r�+ 0' it # "`I • 1 -� � s�^ f1 �? � � d r c e 8 r / ��� ��1���� r+f'1 C 1 ~ L Q ..+ f ���*f1 C� ,l♦ ������a ���. � ■rlrr ,4' Fr *�3 "i'i ���* �1 1 !t t f 1.. V .�,.r�r f 0 r'4i 1 ! i'' •tii ��{ �■ r S,?{� 1��� � �. i. t 8'4t R�``�t i 'a� +. al ?$fl{ i k .. . rG x fi fi''+{��':a�+f ,�,r1 �1 t 5 �, • p F 4 { sk1� :;r� �'��� 4 ion �ssQ N1Q 01:1*.Q. 7 [. 1 a Q pad • t1 , ,►,`uv�i AV.-. d7 {'�1 r :L- - ;3:71: �,i3� F.i 4 '. 4 Rt Of:4 i W 0 3..L 0 0 0 H c, 0 V ! 0 0 0 L 0 0 0 Our Line of Type 11 Double-Wall Tanks is Rustproof. Fiberglass tanks simply will not rust --� inside or out, on all four surfaces of the inner and outer tank. That's the reason Containment Solutions' fiberglass tanks have proven to be safe, cost - effective containment solutions for petro- leum and related products. The fact is after nearly 250,000 installations since the early 1960s, not a single leak has been attributed to internal or external corrosion. True Double -Wall Construction Means High Strength. We build strength and quality into every double -wall tank from the beginning. Tank inner and outer walls and specifically designed ribs act together to form a structural system that has earned the UL 1316 listing that distinguishes this as a true double -wall tank. Secondary Containment Provides 360' of Protection. You can count on total protection from our double -wall tank. Our tanks are available with dry or wet monitoring of the annular space and will detect leaks in inner and outer walls under all conditions. Typical Gasoline System Overview (Mode( DWT6) Standard Features: A. Flow Channels B. Tank Bottom Deflector Plates C. Primary Tank Fittings D. Monitoring Fitting Recommended Accessories from Containment Solutions: 1. FRP Turbine Enclosure 2. Fitting Kits for Turbine Enclosure 3. FRP Secondary Containment Collar 4. Reservoir Sensor 5. Fiberglass Reservoir (replaces monitoring fitting) 6. Containment Collar Sensor 7. Monitoring Fluid with Color Tracer 8. Electronic Inventory Gauge 9. Electronic Control Panel 10. Split Strap Anchor System 11. Deadman Anchor Systems Optional Accessories from Your Local Petroleum Distributor: 12. Dispenser 13. Dispenser Sump 14. Double -Wall Pipe 15. Submersible Pump 16. Fill Tube with Overfill Shut -Off Device 17. Ball Float Valve 18. Overfill Spill Container 19. Primary Tank Vent c to 0 O 7 z 3 0 0 El e 4� TSD-4736 • Tank Sump, Deep Burial, 47" Base, fits 36" Manhole Tank Sump, Medium Burial, 47^ Base, msae^ Manhole rss-4736 Tank Sump, Shallow Burial, 47' Base, fits as^ Manhole The 4736 series one-piece tank sump is made of high density polyethylene with a factory installed gasketed snap-on id. The sixteen side panels ailow or pipe entry from virtually any direc ion. The 4736 series tank sump is available in three burial depths. Each is offered an optional inspection port (IP) for easy viewing of the interior of the sump without removal ofthe lid. ww mm o � 'r wr� = = SI US 5 1 - 1 --- r ---- 11 El -__ __' L - \ U la" | ' / | | 0 U 1 / , m U / Y ][ TSS-4542 Tank Sump Shallow Burial • so^ 39 4s^ 4s^ TSIV1-4542 Tank Sump Medium Burial K A ss^ MAX. z4^ MIN, 12 4o^ MAX. z4^ MIN. T3D-4542 Tank Sump Deep Burial _ ------- -- 16^ _A _I_ e4^ MAX. 2^r MIN. 4 Hsi Mint galvanized steel Cover: steel diamond plate [` rag: cast iron or fabricated steel G yet: Buna -N CustU! I1Ci Ger vice For pcTdals, Powder Coating or Tee; Handles. adard and Raintight Models Available Raintight models include Buna -N gaskets and recessed hex -head bolts or Roto -Lock fasteners to help prevent water intrusion. Wide Range of Sizes - Sizes range from 8" to 48" (25 to 122 cm) to accommodate a wide range of applications. Custom sizes and configurations are also available. Specrifflicaf1l ©[ s I Iodel Description 61 r 0 -0° T 6110 -0800 6110-121 NT 6110.1200 c -:� =`:fir.•... -.�7 r,"cs�',r. cr.: : •„r_:t - - •••_ + Z ?rim bus Raintight Standard Raintight Standard 6110416WT Raintight 6110-1600 Standard 6 110 -1OwT Raintight 61 10 -1800 Standard 6110-241111T Raintight* 6114-2410 Standard* 61104710 6110 -37T) 6110-4010 6110-42VVT Raintight* 6110 ° 4200 Standard 6110 -48W7 Raintight* 6120 -181NT Roto -Lock Raintight 201 51 0.0. in. an 9% 25 Easy Cover Removal - An integral recessed handle is included on all raintight and plain manholes 24" and larger. Manholes 42" and larger include dual recessed handles and provision for centered 112" - 13 threaded alien head blind plug for easy removal so that a 1/2" - 13 eyebolt can be threaded into the hole for easier removal of covers. Highway 20 Rated (H20) - All OPW spill containers and manholes exceed the requirements of the Highway 20 rating. I.D. Thickness Weight in. an in. an lbs. kg Ring 8 20 3/8 9 9% 25 8 20 318 9 12 5 Cast Iron 14% 35 12 30 3/8 9 30 14 Fab. Steel 14% 35 12 30 3/8 9 30 14 Fab. Steel 18 46 16 41 3/8 9 45 20 6110 4301RIT Raintight* 30 76 27% 70 1/2 13 160 73 6110 4010 Standard* 30 76 27% 70 3/8 9 160 73 6110 -371NT Raintight* 37 94 34% 88 1/2 13 178 81 Standard* 37 94 34% 88 3/8** 9 178 81 Standard** 37 94 34% 88 318 ** 9 178 81 Standard* 40 102 37% 96 318 9 198 90 42 107 39% 101 112 ** 13 290 132 42 107 39% 101 112 ** 13 290 132 48 122 45% 116 112 ** 19 390 177 6120-12W7 Roto -Lock Raintight 13 35 12 30 3/8 9 30 14 6120 -24WT Roto -Lock Raintight 24WT* 24 61 22% _55 3/8 9 88 40 6120 -30 WT Roto -Lock Raintight 30vv" 30 76 28% 70 1/2 13 160 73 6120=37WT Roto -Lock Raintight 37WT* 37 94 35% 88 3/8 13 178 81 6120 -42WT Roto -Lock Raintight 42VvT* 42 107 40% 101 1/2** 13 290 132 6120-48 Roto -Lock Raintight 48WT* 48 122 46% 116 1/2** 19 390 177 * Recessed Handle Standard - Plain No Bolts © Copyright 2006, OPW Fueling Components 12 5 Cast Iron Fab. Steel 18 46 16 41 3/8 9 45 20 Fab. Steel 20% 51 18 46 3/8 9 54 25 Fab. Steel 20% 51 18 46 3/8 9 54 25 Fab. Steel 24 61 21% 55 3/8 9 88 40 Fab. Steel 24 61 21% 55 3/8 9 88 40 Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel Fab. Steel 1 46 3/8 9 54 25 Fab. Steel Fab. Steel Fab. Steel Fab, Steel Fab. Steel Fab. Steel ** Reinforced Cover Deep skirts available upon request. Raintight - Bolt Down OPN 11110/1120 Series: Steed Hound Martimore POMECO /OP11 110/120 Series Round Manholes are designed for use in a wide range of service station driveway, industrial, and commercial applications, The 110s and 120s are used to provide access to all types of underground equipment, including vapor recovery connections, UST monitoring equipment and submersible pumps. The 120 Series includes Roto -Lock fasteners on 24" and larger manholes. P110 -18G P110 -24G Hex Head Detail 5116" Bolt Section 1 (See Lid Thickness Dimensions) Replacement Parts Part # Description ��-- -- 0.D. —� 1. D. Roto -Lock Detail 314" Hex P110 -8G 8" Replacement Gasket P110 -12G 12" Replacement Gasket P110 -16G 16" Replacement Gasket 18" Replacement Gasket 24" Replacement Gasket P110 -30G 30" Replacement Gasket P110 -37G 37" Replacement Gasket P110 -400 40" Replacement Gasket P110 -42G 42" Replacement Gasket P110 -480 48" Replacement Gasket P110 -36TEE "T" Handle Cover Lifter PROTO -LOCI( (1) Replacement Rotolock P110 -8L Replacement Cover 8" P110 -12L Replacement Cover 12" P110 -16L Replacement Cover 16" P110 -18L Replacement Cover 18" P110 -24L Replacement Cover 24" P110-37L Replacement Cover 37" 1-314" P110 -40L Replacement Cover 40" P110-42L Replacement Cover 42" P110 -48L Replacement Cover 48" P120-36L Replacement Cover 36" Rote -Lock P120-37L Replacement Cover 37" Ro' =L ock P120 -42L Replacement Cover 42" Ro'ax -Lock �� 1 FLEX CATCH Below Grade Spill Containment 5 Galion BG Part no Drain Valve Test Plug 705 - 445 -01 705 - 225 -02 90022 705 - 445 -65 705 - 225 -02 705-450 -01 705 - 120 -01 705 - 455 -01 705- 225 -02 705 -457 -01 705 - 120 -01 705- 474 -01 705-332 -19 705- 474 -65 705 - 332 -19 705 - 475 -01 705 - 332 -19 705- 475 -65 705 - 332 -19 15 Galion BG Part no. Drain Valve Test Plug 705 - 438 -06 705 - 120 -01 90022 715- 438 -05 705 - 120 -01 715- 439-01 705 - 120 -01 715- 446 -01 705- 225 -01 715- 446-65 705 - 225 -01 715- 456 -01 705 - 225 -01 715- 474 -01 • 705 - 332 -19 715- 474 -65 705 -332 -19 715 -475 -01 705 - 332 -19 715- 475 -65 705 - 332 -19 25 Gallon BG Part no Drain Valve Test Plug 725 - 429 -03 705 - 120 -01 90022 725 -447 -01 705 - 225 -03 725 - 474 -01 705 - 332 -19 725 - 474 -65 705- 332 -19 725 - 475 -01 705 -332 -19 725 - 475 -65 705- 332 -19 5 Gallon BG Below grade installation 15 Gallon BG ►► M►►►a► ►► i i iii i i ► ii i i i i► M►►AF►► NIVA rI►M►► ■ �NII ►M�r►�► r ►►NI rw►►►►r►MEUM►► MIIM MAWIMNIFNMIZIWN ►►►....,.. Flush Mounted 18" Manhole 15 Gallon Below Grade 25 Galion BG Sales Desk (800) 475 -3291 • Sales Fax (800) 475 -4329 • Phone (231) 755 -1671 2814 McCracken Avenue, Muskegon, MI 49441 • Fax (231) 755 -7201 • http: / /www.ebw.com © 1999 EBW, Inc., Form 80028 7199 , 6130-4000 61S0 -4010 6130-3000 fiszerathy Installation schematic typical; exact dimensions will vary with tank configuration, OP IN 61S0 Ovellill Prevention Valves are covered under the following patent: ,4,936,320. Re: #33,555 and Canadian patent #1,287,546. Other patents pending. Replacement Parts Part # Description 6130K -0001 CO3899M CO3632M D01756 R11 931 M Ordie[t g Product/ Suffix# Float Kit Two -point inlet tube Coaxial inlet tube Inlet Tube /Adaptor Assy. for 61SOP Drop Tube 0-Ring g ee riC,F [d0.)P Description 6130-1000 Grooved -tube 3" two -point 60 1.5 4" two -point 4" two -point c max A -Upper Tube Length in. m 0Pw 1-2100-EVR B max 60 1.5 . 83 oPw 634TT Cap 6" or per local code OPW 6150 -4000 * From inside wall of tank to bottom of upper tube Unde ground tank, typical 83 2.1 1551 4.0 2.1 154% 3.9 OPW 633 Adaptor Tube er d cut per local requirements in, m in. m in. m in. 61S0-4000 -EVR GARB 4 ", two -point 60 1.5 83 2.1 154% 3.9 531 1,4 96 2.4 107 2.7 16 7 6150 -4100 -EVR CARB 4 ", two -point 120 3.1 102 2.6 233% 5.9 1131 2.9 120 3.1 126 3.2 25 11 61 SO -4200 -EVR GARB 4 ", two -point 120 3,1 126 3.2 257% 6,5 1131 2,9 144 3.7 150 3.8 26 12 61 JSK- 4400•EVR Jack Screw Assembly; CARB 6130 Installation Kit. Required on all 61 SC -EVR Models 6130-490C 61SOM- 4121`$ Two - point, ethanol/ methanol 61SOM -4120 -EVR*$ GARS 4 ", two - point, ethanol /methanol 6130C-4001 Coaxial 61 SOC -4011 Coaxial 4" KIWA vapor-tight 60 1.5 © Copyright 2006, OPW Fueling Components 83 2.1 1541 3.9 531 53% 1.4 1.4 96 2.5 96 6" or per local code B -Lower Tube C- Overall Max. Riser Max. Nominal Max. Actual Length Length Length Tank Dia. Tank Dia. m in. 2.4 OPW 61 SOR -4000 108 107 4 " -8" long 4" NPT Nipplk 2.7 2.7 17 60 1.5 83 2.1 154% 3.9 531 1.4 96 2.4 107 2.7 16 7 120 3.1 102 2.6 233% 5.9 1131 2,9 120 3.1 126 3.2' 25 11 531 1.4 96 2.4 107 2.7 16 7 120 3.1 102 2.6 233% 5.9 1131 2.9 120 3.1 126 3.2 25 11 *For use with M85 & M100 methanol fuels 'Remote fill applications *'`*Remote fill, methanol $ Methanol (M85) and Ethanol (E85) models do not include lower drop tube, Adaptor for 3" A.O. Smith Fiberglass Pipe (Drop Tube) is included. Appropriate length of 3` 1'..0, Smith Fiberglass Pipe is required for lower Drop Tube (not furnished). UUgarground typical wet t. lbs. itg v'. 13 6 8 120 3.1 not included 233% 5.9 1131 2.9 120 3.1 126 3.2 25 11 120 3.1 not included 233% 5.9 1131 2.9 120 3.1 126 3.2 25 11 60 1.5 83 2.1 154% 3.9 531 1,4 96 2.4 107 2.7 16 7 61 SDP -4002 CARB, pop. coaxial 60 1.5 83 2.1 154% 3.9 531 1.4 96 2.4 107 2.7 20 9 6130P-4012 CARB, pop. coaxial 108 2.7 102 2.6 221% 5.6 1011 2.6 120 3.1 126 3.2 27 12 61 SDCM- 4000$ Coaxial, ethanol /methanol 120 3.1 not included 233% 5.9 1131 2.9 120 3.1 126 3.2 25 11 61 SO -4BYT Overfill valve only, no drop tubes supplied 6150R-4000** Remote 72 1.8 83 2.1 166% 4.2 651 1.7 96 2.4 107 2.7 19 9 61 SORM- 4000 * * *$ Remote, ethanoVmethanol 72 1.8 not included 185% 4.7 651 1,7 120 3.1 126 3.2 19 9 61 JSK -4RMT Jack Screw Kit for Remote application ._ 99mm r (5pern-,1 lapmegohe[ic Varnt Open Atmospheric Vents are installed on the top of vent pipes from underground or aboveground fuel storage e tanks. The vent cap and internal wire screen are designed to protect the tank vent lines against intrusion and blockage from water, debris or insects. These vents are always open to atmosphere and allow any pressure or vacuum in the tank to vent. The OPW 23 Series is a perfect choice for many applications. 3%" 92mm ( 37:1:0LW knAiatdion Filuet Viadw,/c-Pz isolation Float Vent Valves are installed aboveground on manifold vent pipes from underground fuel storage tanks. An internal stainless steel ball isolates each tank vent, should the storage tank overfill, sending product into the vent lines to help prevent intermixing of different grades of fuel. s:? Waal) carts R w North America Toll Free — TELEPHONE: (800) 422 -2525 Fax: (800) 421 -3297 Email: domesticsales @opw- fc.com International — TELEPHONE: (513) 870 -3315 or (513) 870.3261 Fax: (513) 870 -3157 0 Email: intlsales @opw- fc.com 0 wwv,wpw- fc.com P.O. Box 405003 <= Cincinnati, OH 45240 -5003 <. 9/06 4,° }3)j © Copyright 20)6, OF 1/V Fue;iing Components V f ��... � #�`'�..E =L� �;.�• is Body: aluminum Screen: 40 -mesh brass Set Screws: brass 4 Reliable Service — Vent cap drain spouts extend outward to deter rainwater entry. Corrosion - Resistant Construction — Aluminum body and cap assure a long service life. Easy Installation — The 23 is available in 2" and 3" slip -on models that provide for attachment to the vent line with set screws. SpeeilEiCaliORM Product # Description in. mm lbs. kg ,A2 2 2 3-0044 Open Vent 1'X 38 .25 .11 3 -0033 Open Vent 2 51 .25 .11 23 -0055 Open Vent 3 76 1.6 .73 Stainless Steel Ball Float — Ensures a clean, tight seal against the valve body. Aluminum Valve Body — Corrosion- resistant for a long service life. OPW 320 DV Product # ,> Complies with NFPA 30 Requiremeff's — For venting gasoline vapors upward, t High Maximum Flow Rate — 7000 S(FH at 2 psi (0.1 bar) pressure drop. 40 -Mesh Brass Wire Screen --- Helps prevent debris and insects from entering the tank vent lines. Replacement Parts Part # Description H00122M Screw H01967M Nut H01969M Screen ra rs Fxn d in. mm : • kg 3201DV0130 3:3x2 76376X51 f'4`2 2.15 c ww Monitoring/ Observation Well Aanholes Monitoring /observation well manholes are designed to be installed at grade level over a slotted PVC monitoring well where limited access and clear identification are essential. rt Dimensions MONITaRING 1 OBSERVATION WELL DO NdT FILL WARNING: r ar�TFU,cEr.soulx Cxi OTHER P£i1�JLEyyNH11 %lDOL1CT5IfJID T7S+5 tR.IV}ip(_E Gil WELL ViWAi'pR$ Flk B� .�.-i7� g TO a Dii LA.'+�lSW4 � ltti.iiES A D C Product # in, rnm in. mm in mm 104A0W -0800 8" 203 101" 257 1114" 286 104AOW -1200 12 "' 305 141" 362 111" 286 104A0W -1219 IF 305 141" 362 19%" 489 10 4A0W -1800 18" 457 20r 511 111" 286 104 A0W.1819 18" 457 20%" 511 191" 489 © Copyright 2006, OPW Fueling Components + DOVER) COMPANY North America Toll Free TELEPHONE: (800) 422 -2525 F x: (800) 421 -3297 + Email: domesticsales @opw- fc.com Intematonal — TELEPHONE: (513) 870-3315 or (513) 870-3261 Fax: (513) 870 -3157 4 Email: intlsales@opw-fc.com • www.opw-fc.com P.O. Box 405003 + Cincinnati, OH 45240 - 5003.9/06 Materials Cal NE Cam Pik N: 0 E trii Body ring: cast iron Cover. cast iron Skirt: steel (104 AOW /MW) Gasket: neoprene Features • "DO NOT FILL" Graphic Warning Statement - Permanently cast into cover with black equilateral triangle inset into a white background in accordance with API Recommended Practices 1615, Secure Cover a Two recessed, self - aligning stainless steel bolts with O -rings secure cover to the body ring. • Prevention Against Surface Water Contamination - A gasket located in the ring_ .prevents contamination from rain water or during washdown. Maximum Load Bearing Capacity - Cast iron covers and body rings are heavily ribbed to ensure maximum load bearing capacity. Trouble -Free Installation a Sturdy steel skirts extend nearly a foot below grade to ensure trouble -free installation even in deep concrete. Ordering Specifications Product # ID (in.) ID (mm) lbs. kg 104A0W -0800 8 203 15 6.8 144AOW -1200 12 305 2 8 12.7 104AOWx1212* 12 305 36 16.4 104AOW -1219 12 305 33 15.0 104A0W -1800 18 457 50 22.7 104A0W -1819 18 457 57 25.9 * Cast iron interference bars 104AOW -1200 ONE SOURCE..' 4. Optional Skirts a Extend a full 19W below grade in 12" and 18" diameter models for sandy soil locations. Unpainted Covers and No Bolt -Down Provisions Available - On the 104MW for monitoring well applications where limited access is not required. Cast Iron Interference Bars - To prevent entry of a delivery elbow, in lieu of bolt -down cover. Available on I04AOW -1212 models. Full -Size Internal Diameters for Maximum Access and Working Area. Highway 20 Rated (H20) - All OPW spill containers and manholes exceed the requirements of the Highway 20 rating. Individually Boxed for Ease of Handling. Replacement Parts Part # Description E005141 Cover for 8" 104AOW -0800 E005151 Cover for 12" 104AOW -1200 E00299M Cover for 12" 104AOW -1212 E005141 Cover for 8" 104MW -0800 E005161 Cover for 18" 104AOW -1800 H12872M Gasket for 104AOW 8" H12873M Gasket far 104AOW 12" H12874M Gasket for 104AOW 18" Tlgi Tigh' und€ tranE gasc Sta! Stag reco' rem Stag esca Mot Mon esca grorr Well cont; OPV The ; OPVI to th( to thf nit �rIng Systems 4 -Tank System Maximum with or without Leak Detection ■ Meets compliance requirements for leak de tectionlin even tort' control in up to four tanks. ■ Available with Continuous Statistical Leak Detection in popular 3 -tank and 4 -tank kits. ► CSLD provides 24 -hour leak detection without tank shutdown. • UL and cUL approved. ■ Simple menu - driven programming and operation functions. • Standard integral printer. ► Proven design means safe and simple set up and installation. Veeder - Root's TLS -300i UST Monitoring System features optional in -tank leak detection, along with inventory control and interstitial leak detection capabilities to meet regulatory compli- ance requirements at your site. The console is available with Continuous Statistical Leak Detection (OSLO) in popular 3 -tank and 4 -tank kits. CSLD provides continu- ous 24 -hour leak detection without tank shutdown. No lost busi- ness. No lost operating time. All systems support up to four Series 8473 Magnetostrictive Probes. The Mag probes can handle a wide variety of fuels and fluids, and have been third -party tested and certified to perform better than the U.S. E.P.A. standards. TLS -300i systems accommodate Veeder- Root's float - switch sensors, including: interstitial sensors for both steel and fiberglass tanks, piping sump sensors, hydrostatic sensors, and discriminating dispenser pan and containment sump sensors. The TLS -300i systems are equipped with audible and visual alarms, triggered by in -tank and interstitial alarm conditions. Any of the in -tank alarm limits can also be tied to relays to trigger on -site devices, such as overfill alarms, or to shut down submersibles. Emergency Generator Applications* ► Selectable via programming. ► One system handles a mix of standard and emergency generator tanks. . Records generator activity. ► Complete inventory reports before and after generator operation. System Capabilities ► Monitors up to four tanks. RS -232 communications interface with auxiliary port provides two 25 -pin D- connectors for data transmission. ► Standard integral report printer documents inventory leak detection, alarm and setup information. In -Tank Leak Detection Capabilities* . Accommodates any combination of up to four Veeder -Root Magnetostrictive Probes: • 0.1 GPH in -tank leak detection capability. • 0.2 GPH in -tank leak detection capability. CSLD available in easy -to -order 3001 -3 and 3001 -4 kits. Leak Sensing Capabilities ► Automatic continuous leak sensing: Tank interstitial space • Piping Sump 0 Dispenser Sump ► Audible alarm and display indicate leak location. . Supports Discriminating Dispenser Pan and Containment Sump Sensors. Alarm Capabilities In -tank warnings and alarms are activated for the following conditions: • Leak* • Low product • Sudden loss 0 Delivery needed • Overfill • Test failure* • High water • Tank test not performed"' Interstitial and piping sump warning and alarms are activated for the following conditions: Fuel presence • Low liquid B High liquid . Alarm relays can trigger alarm /security devices. Input/output Capabilities Two built -in inputs provide for: Solid -state or switch input from external devices. Two built -in output relays provide for: 0 Outputs to overfill alarms and external audible and visual warning devices. ► Either relay can shut down the submersible if power to the monitor is lost or a leak is detected. For systems equipped with in -tank leak detection or CSLD. Standard Console Models CONSOLE FORM NO, Easy -to- order 3 -tank and 4 -tank Kits with CSLD KIT FORM NO, KIT DESCRIPTION Console/Probes/Sensors Compatibility The following probes are compatible with the TLS -3001 UST Monitoring System: 13400 PROBE FORM NO.t f Refer to Veeder -Root Price List for required probe and sensor lengths and corresponding 3 -digit Form Number suffix. KNOCKOUTS FOR RS -232 —_ (3 — 9 -Pin and 2 — 25 -Pin 0- Connectors) 114" HOLE 4 PLACES 1.00" Dimensions 20.00" 16.00" FRONT VIEW BOTTOM VIEW P/N 577013 -502 1/2 - 3/4 I.P.S. KNOCKOUT (TOP & BOTTOM) Y VEEDER-ROOT Environmental Products The Leader in Tank Monitoring Technology 3/4 - 1 2.P.S. KNOCKOUT (TOP & BOTTOM) DESCRIPTION DESCRIPTION 11.25" 125 Powder Forest Drive, Post Office Box 2003, Simsbury, CT 06070 -2003 TEL: (860) 651 -2700, FAX: (860) 651 -2719 TECH SUPPORT: (860) 651 -2753 BRAZIL: Sao Paulo • CANADA: Mississauga, Ontario • ENGLAND: Richmond Surrey • FRANCE: Aulnay- Sous -Bois • GERMANY: Aidingen • SINGAPORE: Singapore printed VR6 �S 95 0 v eecter® oot c� A T LS3OOi 3-4 Tangy OInfi Console UST Monitoring Systems Product uct Over de w Designed to provide the highest quality and most cost - effective tank monitoring system for cost -- conscious retail petroleum marketers, the TLS -300i 3-4 Tank configurable console is an ideal value for many independent and /or smaller retail petroleum marketers. Veeder- Root's TLS -300i Tank Monitoring System can be configured to provide in-tank leak' detection or continuous statistical leak detection (CSLD) for underground storage tank (UST) applications with up to four leak detection Series 8473 0,1 GPH Maanetostrictive Probes, or four Series 8473 Magnetostrictive Inventory Measurement Probes to support Aboveground Storage Tank (AST) applications. Additional configurable options are designed to provide printed documentation and remote monitoring flexibility. The optional Integral Printer provides fast, quiet continuos printouts. The optional SiteFax feature can be programmed to transmit leak detection and inventory reports, as well as real - time alarm reporting to fax machines or other communications devices. Standard features include back-up generator capabilities, as well as capacity to accept up to eight Veeder-Root Series 7943 float - switch sensors. This high quality, low cost family of sensors includes interstitial leak sensors for steel and fiberglass tanks, piping sump sensors, hydrostatic sensors, and discriminating dispenser pan and containment sump sensors. Specifications tions - Rai:: r Features http://www.veeder.comidynamicipintable.citia?pageM=1 50 • System monitors up to four tanks. 6 RS -232 Communication Interface with Auxiliary Port provides two 25-pin D- connectors for data transmission to computers or point -of -sale terminals. • Automatic continuous leak sensing: tank interstitial space; piping sump O Audible alarm and display indicate leak location • In -tank warnings and alarms are activated for the following conditions: leak, overfill, low product, sudden loss, high water, delivery needed, test failure, tank test not performed. O Accepts up to eight interstitial / containment float switch sensors ▪ Interstitial and piping sump warnings and alarms are activated for the following conditions: fuel presence, low liquid, high liquid • Alarm relays can trigger alarm/security devices e Two built -in inputs provide for solid -state or switch input from external devices e Two built -in output relays provide for outputs to overfill alarms and extern& audible and visual warning devices O Either relay can shut down the submersible if power to the monitor is lost or a leak is detected e Emergency generator applications are selectable via programming e One system handles a mix of standard and emergency generator tanks 4 Records generator activity O Complete inventory reports before and after generator operation • Features & Benefits Manuals, Guides, Certifications Ready to Buy Distributor Search Page 1 of 2 215 /04 V ceder - oo t P age 2 of 2 °moo g u e Options • Continuous Statistical Leak Detection for in -tank leak detection without tank shutdown. a Integral printer, which documents inventory leak detection, alarms and setup information. • SiteFax modem for remote management of leak detection and inventory alarms and reports. O One or two Veeder -Root Magnetostrictive Probes for 0.1 GPH in -tank leak detection with 4" float kit and 5" cable 0 One or two Veeder -Root Inventory Only Probes for Inventory Control with 4" float kit and 5tt cable Mandard V41© Console Form No 848590 -421 848590 --411 848591-002 Software Enhancement Modules 330161 -001 330161 -003 Optional Site F Modern 331398-001 Form No. 847390 -1XX 847391 --)00( 847390-3XX 794390-40X 794390-420 794390 -20X 794380-301 794380-302 794380 -322 794380 -352 Description TLS -3001 3-4 Tank Configurable Console with Integral Printer TLS -3001 3-4 Tank Configurable Console without Integral Printer TLS -3001 3-4 Tank Configurable Console - PC Version Note.: Must be specified on order Static In-Tank Testing CSLD Note: Must be specified on order Site Fax Modem Kit for TLS -300 Series Consoles The following probes and sensors are compatible with the TLS -300C Monitoring System: Description 0.1 GPH Magnetostrictive Probe 0.1 GPH Magnetostrictive Probe for Alternative Fuels Magnetostrictive Probe for Inventory Measurement Interstitial Sensor for Fiberglass Tanks Interstitial Sensor for Steel Tanks Piping Sump Sensor Single -Float Hydrostatic Sensor Dual-Float Hydrostatic Sensor Discriminating Dispenser Pan Sensor Discriminating Containment Sump Sensor Please refer to Veeder -Root Price List for required probe and sensor lengths and corresponding 3 -digit Form Number suffix. Print Close ham: / /wwwo veeder. com/dynamic /printabI e. cfin?pagern =15 0 2/5/04