Loading...
HomeMy WebLinkAbout2008-02-27 BRAA Ltr to OPH7335 Highway 36 W St. Paul, MN 55113 Tel 651 - -636- -4600 Fax 651-636-1311 www,bonestroo,com February 27, 2008 Mr, Eric Johnson City Administrator City of Oak Park Heights 14168 Dak Park Blvd., P. D. Box 2007 Oak Park Heights, MN 55082 -2007 Re: W.A.T. E. Enterprises Plan Review sus' l ,n' - - Aroo No 55-08-1-)Of) Dear Eric: Al. Bonestroo Ir We have reviewed the general plans for the W.A.T.E. Enterprises (5570 and 5590 Memorial Avenue) as submitted by Folz, Freeman, Erickson, Inc. Following are our comments and/or recommendations. Development Comments All utilities and parking lots will be privately owned. I . The tree removal plan shall be reviewed by the City Arborist. r i 1 1. There are several doors shown around each building that open to bituminous surfaces. Will there be concrete stoops at the doors? If not, concrete stoops are recommended at each door to prevent the creation of a trip hazards if the bituminous settles or not allowing the doors to open as the bituminous heaves. 2. The current drawing has several transformers on the property to the north. Are these transformers for the proposed 5570 and 5590 buildings? If so, are there any issues with future ownership? 3. The transformers adjacent to Building 5600 are placed directly on top of the existing sewer and water service. Verify that there will be no conflicts with these utilities and the electrical conduits. The transformers at this location could potentially cause future problems if repair is necessary on the water or sanitary service. St. Paul St. cloud Rochester Milwaukee Chicago City o/Ook Pork Heights poge 2 m<x.T.sentenorisea 2-27u8 '`--^'`" 1. Detailed design drawings and calculations for any retaining walls over 3.0 feet tall shall be submitted to the Cit for review and approval prior to construction. 2. If the client wishes to replace the rip rap with a more natural appearance the turf reinforcement mat P Propex can be used, I It is recommended that the erosion control protection that is placed north of the flared end sections be extended to the next drivewa entrance. r L - -.L e-^ 4 1.Verity there is, adequate cover for the 27 sewer at the nmiheast comer of the site. 2. Due to the water main on the southwest side of the property being only 5feet from the property line it is recommended that a temporary easement be obtained from the Post Office for the ,construction of this water service, as well as an other g radin g activities that ma encroach. 3. Submit the rational desi worksheet for the storm sewer desi General Comments I . The additional items shall be submitted for confiramtion: a. Copy of the A letter from the Browns Creek Watershed District. If you have any questions or require additional information, please contact me at (651) 604-4788 or Dennis Postler at (651) 604-481 BONESTROD ' Karen S. Erickson, P.E. cc: TomDzzeUo' Public Works Director Jim Butler, Building Official Scott Richards, City Planner Mark Vler|ing. City Attorney Todd Erickson'Fo|z Freeman Erickson, Inc. DMP Fi|e — Bonestroo&Associates