HomeMy WebLinkAbout2019-09-27 Interstate Testing RPZ Test Report Sep.30.2019 11:32 AM Interstate Testing 7637555365 #3590 P 2/ 2 Interstate Testing, LLC P.O. Box 55 Anoka, MN 55303 REGULATED BACKFLOW ASSEMBLY (RBAJ APPLICATION FORM/TEST REPORT COMPLETE JOBADDRESS(INCLUDE Apt/Unit 0) NAME OF BUILDING.OWNER/OCCUPANT,CONTACT NAME AND PHONE NUMBER 5990 Nova Scotia Ave, N. Bremer Bank (Oak Park Heights) KeHlly ec(sel (651)312-3215 Oak Park Heiglits, MN 55082 Kelly LlecKsel .... APPLICANT COMPANY NAME CONTRACTOR LICENSE it CONTACT NAME AND PHONE NUMBER Interstate Testing, LLC PC751575 0 Q n.r MileJ (763)744-6149 ADDRESS CITY STATE ZIP EMAIL P.O. Box 55 Anoka MN 55303 interstatetestinqAcomcast.net TESTER NAME TESTER CERTWICATION# PHONE Donn Miller B=065323 (763)744-6149 TEST EQUIPMENT MANUFACTURER TEST EQUIPMENT MODEL# TEST EQUIPMENT SERIAL# TESTING EQUIPMENT CALIBRATION DATE Midwest Instruments 845-5 05090906 01-16-18 F`,.'71, ,I, 40.:4;j5-;:,,,,, .'1::!':•D.:!i't9..4.',C('?.'7 r.7.040#4:105IAii 6 FEE'Ii4 FORIVATI OK(0 kit one .:.'''..',.,.,.:,,,..,g.A.-•'..;5• ','.:.,-;441::.::,',','i..,1:. Install Relocate Remove Replace and SNO of Replaced Device _Rebuild X Test Aiit05,10ASSEMBLY0(0iiiii, iiiooft441104 2,0....,Q:s.y,,,,,,':-.,,,,;;;;;:i:,•,:-../. .fief:',. ..4,•;!:1,s.,444,,r.;;.,,es,,?,.z..,,,,,..r...,,..„ , ,..,,,......., , i i —. ,, ..• .;•,4,-;‘.,•• .,•,•• • _., ,-It;,,,v,..,,, . ,:., Type(check one): . ..... Reduce Pressure Principal Of Prsure Principal Fire Protection, Reduced Pressure Detector Fire Protection Double Check Valve Double Check Detector Fire Protection _Pressure Vacuum Breaker..._Spill Resistant Pressure Vacuum Breaker Manufacturer:VVOttS Model# 009M2 Serial 1 AQ0110 Sizeinches) system serviced I rri q a tio n Location in bidg Risor room gear# Room tt RiSOr P•-gY 11t:OV.'.4A41121:1003H.'\..E;I:041t., .''!,A(0,"elAiftgisft' 7,40.0 6#,O.,i,4,. ..:i, tr, iti_i,iit.:;, !*, E:4.:i,i.b.,,4-,•,,,,,,1*t. .51)2. ...-,;:.:,.:„.:',.'' --;:: •: 04#44441,..:,#`.,iiifiiitiifi,po.:fi*fot,*tto4c*it4;.000,4ie:oyokooKkvo::**to'o*ixlg:tvq,f4T.Aov)-oA,ir,,,.R.;:?;.i:':;:w: : :: Pressure Differe,ritial Check Valve#2 Shutoff Valve#2 Check Valve#1 Relief Vail/e initial Cloed Tight X Yes No Closed light .Yes_No Closed Tight .X.,..Yes—No Test Opened at 2,2 psid Pressure Drop Across Check Valve#1,9.2 psid Final Closed Tight _Yes No Closed Tight Yes No Closed Tight —Yes—11/410 Test IYOpened at psid . Pressure Drop Across Check Valve#1, psid ''' ' ,',' '' .-,ii i,•',...Vd.Vr'','''-iiiii4-‘4'sei,,1,Atiii0i'liititiri-t46 .'itio;:;oi 'it4*::11-6ii)t. ,, ,-"ct4,iii 6. ''.-4ESt t..kitiA.z,!:::,i.:,.,,,.,:1::::.,:•iiii,,,..,:,.,..,,,,.,,,,:,5,,, ,:. , „, . ... . . Check Valve#1 Check Valve 42 Shutoff Valve#2 Initial Test closed Tight Yes No psid Closed Tight Yes No osid Closed Tight Yes _No Final Test Closed Tight Yes No psid Closed Tight Yes No psid Closed Tight Yes No 14;;; :•::::".,: Fir' S4illi*444e*ii440j0,(/.6):ti 1Ts*k$k4;r7i,‘'(/44iifii.41:6ki(skiii40ii***!# :, :?2qr.;*i:.ti;,,I: Air Inlet Valve initial Test Failed to Open _Yes No Closed Tight Yes CheckNoValve _ 1 Shutoff P2 Closed Tigtrt Yes No Opened at. psi d Pressure Drop Across Check Valve#1___psid . _ Closed"Reit Yes No al Test opened at psid PressureClosed Yes Drop Across Check Valve#3. _psi d Tight — No .. . , t I Describe parts and repairs when needed: I EC RTIFICAnom I hereby certify the'foregoing information wmride.dbymtw . . rect and that the test device Is functioning in compliance with State of Minnesota Plumbing Code,Chapter 4714. P)/111 ___ TESTER'S SIGNATURE TEST DATE09-27-19