HomeMy WebLinkAboutPL 2019-00326 Remodel - Wendy's CITY OF OAK PARK HEIGHTS
111110 111 1111111 1111
14168 OAK PARK BLVD N.
OAK PARK HEIGHTS, MN 55082- * 2 0 1 9 - 0 0 3 2 6 *
(651) 351-1661 FAX: (651) 439-0574 ISSUED: 12/04/2019
Permit #: 2019-00326
ADDRESS : 14560 60TH ST N
PIN : 33.030.20.43.0037
LEGAL DESC : SUMMIT PARK
: LOT 0 BLOCK 6
PERMIT TYPE : PLUMBING
PROPERTY TYPE : COMMERCIAL
CONSTRUCTION TYPE : REMODEL
VALUATION : $ 1500.00
No I I I: INS IAIJ.NEW KITCHEN I IAND-SINK. REPLACE WATER CLOSETS& LAVS(X2)PER APPROVED PLANS. WORK SI TALL
COMPLY"WI"III MN CODE_AND LOCAI,ORDINANCE REQUIREMENTS. (.MN DLI PLAN REVIEW PB-R1911-0112)
VALUE OF PLUMBING 3500
APPLICANT PLUMBING-COMMERCIAL 75.00
PLUMBING STATE SURCHARGE COMMERC IAI 1.75
NORTHERN MECHANICAL CONTRACTORS LLC TOTAL 76.75
1975 SENECA RD
4100 Payment(s)
E
CHECK 8214 76.75
AGAN. MN 55122-
(65 I) 789-2275
OWNER
FOURCROWN INC& ACORN BUSINESS CTR
ONE DAVE THOMAS BLVD
DUBLIN.OH 43017-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed
according to: (I)the conditions of this permit:(2)the
approval plans and specifications:(3)the applicable city
approvals.Ordinances. and Codes:and.(4)the State Building
Code. This permit is for only the work described,and does
not grant permission for additional or related work which
requires separate permits. This permit will expire and become
null and void if work is not started within 180 days.or if work
is suspended or abandoned for a period of 180 days any time
after work has commenced. The applicant is responsible for
assuring all required inspections are requested in conformance
with the Minnesota State Building Code.
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
PLUMBING SPECIFICATION CONTINUED:
1
ROOF DRAINS:TYPE"RD".CAST IRON ROOM DRAIN WITH FLANGE,FLASHING RING WITH GRAVEL STOP UNDERDECK CLAMP,CAST IRON MUSHROOM DOME STRAINER,AND ADJUSTABLE EXTENSION
FOR VARING INSULATION THICKNESS,SHALL BE A WADE SERIES 3000AE,JOSAM SERIES 2100,WATTS DRAINAGE SERIES RD-300 OR APPROVED EQUAL.TYPE'ORD"CAST IRON ROOF DRAIN WITH
F FLANGE.FLASHING RING WITH GRAVEL STOP,UNDERDECK CLAMP,CAST IRON MUSHROOM DOME STRAINER,ADJUSTABLE EXTENSION FOR VARING INSULATION THICKNESS,AND ADJUSTABLE PVC
STANDPIPE.
ALL PROTIONS OF:THE STORM SEWER SYSTEM LOCATION WITHIN 10 FEET OF THE BUILDING OR WATER SERVICES LINE MUST BE TESTED IN ACCORDANCE WITH MINNESOTA RULES,CHAPTER 4714,
SECTION 1109.0
IN NO CASE SHALL WATER FROM ROOFS BE ALLOWED TO FLOW UPON THE PUBLIC SIDEWALK(SEE MINNESOTA RULES,CHAPTER 4714 SECTION 1001.1).VERIFY THE DISCHARGE FROMQ
RAINWATER CONDUCTORS WILL MEET THIS REQUIREMENT. ALL
CO
WATER SUPPLY PIPING:ALL ABOVE GROUND WATER SUPPLY PIPE SHALL BE TYPE L HARD TEMPER COPPER WATER TUBE COMPLYING WITH ASTM B88.FLOW GUARD CPVC GOLD,OR PEX. Q) > 0)
5' _a
POTABLE WATER PIPES AND FITTIGNS WITH LEAD CONTENT MUST NOT EXCEED 0.25 PERCENT LEAD IN THE WEETED SURFACE MATERIAL(SEE MINNESOTA RULES,CAPTER 4714,SECTION 604.11). `
SOLDER AND FLUX FOR POTABLE WATER SYSTEMS SHALL CONTAIN LESS THAN 0.2 PERCENT LEAD.JOINTS MUST INCLUDE NON-CORROSIVE NON-TOXIC PASTE-TYPE FLUX COMPLYING WITH ASTM
B813(SEE MINNESOTA RULES,CHAPTER 4714,SECTION 605.3.4). O
E 13
ALL COPPER FITTINGS SHALL BE WROUGHT COPPER.DIELECTRIC COUPLINGS SHALL BE USED BETWEEN STEEL AND COPPER CONNECTIONS.ALL BELOW GROUND WATER SUPPLY PIPE SHALL BE O (0
C E
TYPE K COPPER WATER TUBE. A O
DOMESTIC WATERPIPING ON PLANS ARE SIZED FOR COPPER INSTALLATION.IF CPVC IS USED,SOME MANUFACTURERS OF CPVC WATER DISTRIBUTION PIPE USEA LIMITING VELOCITY OF 5 FEET a1
PER SECOND FOR IRON PIPE(IPS)CPVC AND 8 FEET PER SECOND FOR COPPER TUBE SIZE(CTS)CPVC,IF CPVC WATER DISTRIBUTION PIPING IS INSTALLED,VERIFY THEY PIPE SIZING MEETS THE • O N
CPVC REQUIREMENTS. @ 0 - C M
CROSS-LINK POLYETHYLEN(PEX)BUILDING SUPPLY SERVICES PR WATER DISTRIBUTION SYSTEMS MUST MEET MINNESOTA RULES,CHAPTER 4714,SECTION 6065.10 AND TABLE 604.1: ' CO 03L O Y
1. THE TUBING SYSTEM MUST COMPLY WITH ASTM F877,F877,F876,OR CSA 8137.5 AWWA C904 PEX MAY BE USED FOR COLD WATER APPLICATIONS ONLY(SEE TABLE 604.1) N
2. ASTM F876 TUBING MUST BE MARKED WITH THE STANDARD OF THE FITTINGS TO BE UTILIZED. (0 •� LO
- O
3. THE FITTINGS MUST BE MARKED WITH ASSE 1061,ASTM F8�7,ASTMA F1807,ASTM F1960,ASTM F1961,ASTM F2080,ASTM F2159 OR SCA 8137.5 0
THE INSTALLATION'OF ASTM D2846 CPVC WATER DISTRIBUTING PIPING MUST COMPLY WITH MINNESOTA RULES,CHAPTER 4714 SECTION 605.4 AND TABLE 604.1: U p (� O Z
1. PIPES MUST MMET ASTM STANDARD D2846,F411 OR F442. a A-' O O C C
2. FITTINGS MUST MEET ASTM STANDARDS D2846,F437,F438,F439,OR F1970. 0) OO L. CU O
3. SOLVENT CEMENT MUST COMPLY W TH ASTM F493.SOLVENT CEMENT REQUIRING THE USE OF PRIMER MUST BE ORANGE.PRIMER MUST MEET ASTM F656 AND BE COLORED.ONE-STEP ` _ ,� U
YELLOW OR RED O La O ® cn -,
4. [HE INSTALLATION MUST COMPLY WITH IAPMO INSTALLATION STANDARD 20,INCLUDING PROVISIONS FOR EXPANSION AND CONTRACTION.
ABOVE-GROUND HORIZONTAL PIPES MUST BE SUPPORTED AS FOLLOWS(SEE MINNESOTA RULES,CHAPTER 4714,TABLE 313.1 AND THE APPLICABLE INSTALLATION STANDARD):
1. PEX PIPE:32 INCHES FOR 1-INCH AND SMALLER,4 FEET OR LARGER SIZES.
2. CPVC PIPE:3 FEET FOR 1 INCH AND SMALLER,4 FEET FOR LARGER SIZES.
3. COPPER TUBING WTH SOLDERED OR BRAZES JOINTS(114 INCH OR LESS):AT LEAST EVERY 6 FEET.
4. COPPER TUBING WITH SOLDERED OR BRAZED JOINTS(2 INCH OR OVER):AT LEAST EVERY 10 FEET.
5. COPPER TUBING WITH MECHANICAL JOINTS:PER ADMINSTRATIVAUTHORITY REQUIREMENT.
COPPER WATER SERVICES MUST MEET ONE OF THE FOLLOWING ASTM STANDARDS:842,B75,B88,B251,B302,OR B447(SEE MINNESOTA RULES,CHAPTER 4714,TABLE 604.1)
THE WATER SUPPLY SYSTEM MUST BE DISINFECTED PER MINNESOTA RULES,CHAPTER 4714,SECTION 609.9
VALVES SHALL BE INSTALLED PERMITTING THE WATER SUPPLY TO EACH ROOM OR INDIVIDUAL FIXTURES TO BE SHUT OFF WITHOUT DISRUPTING ANY OTHER PORTION OF THE BUILDING.
WATER METER:THIS CONTRACTOR SHALL VERIFY THE SPECIFIC REQUIREMENTS OF THE LOCAL WATER UTILITY AND PROVIDE METER AS REQUIRED.METER SHALL COMPLY WITH ALL
PERFORMANCE AND MATERIAL STANDARDS OF THE AWWA.PROVIDE REMOVE DIGITAL READOUT AT 5'-0'A.F.F.COORDINATE LOCATION WITH OWNER.
COMBINATION FIRE.PROTECTION/DOMESTIC WATER SERVICE MUST COMPLY WITH THE BACKFLOW PROTECTION REQUIREMENTS OF MINNESOTA RULES CHAPTER 4714,SECTION 603.5.15,
1. FIRE SPRINKLER SYSTEMS IN WHICH ANTI-FREF7F OR OTHER CHEMICALS MAY BE INTRODUCED DIRECTLY;
2. PUMPER CONNECTIONS LOCATION LESS THAN 1,700 FEET FROM A NONPOTABLE SECONDARY WATER SOURCE(LAKES,RIVER,OR OTHER SURFACE WATER SOURCE)THAT IS CAPABLE
OF BEING USED BY THE FIRE DEPARTMENT;OR
3. PUMPER CONNECTIONS SERVED BY NONPOTABLE SOURCES INCLUDING FIRE DEPARTMENTS VEHICLES CARRING WATER OF QUESTIONABLE QUALITY,OR WATER THAT IS TREATED
WITH CHEMICAL AGENTS.
LAWN IRRIGATION SYSTEM MUST BE PROVIDED WITH AN APPROVED BACKFLOW PREVENTER IN ACCORDANCE WITH MINNESOTA RULES,CHAPTER 4714,SECTION 603.5.6 SYSTEMS INCLUDING
CHEMICAL INJECTION OR PREVISIONS FOR CHEMICAL INJECTION MUST HAVE REDUCED PRESSURE ZONE BACFLOW PREVENTER.
PROVIDE SHUT-OFF VALVES BEFORE AND AFTER WATER METER.
IF REQUIRED,PROVIDE A PRESSURE REDUCING VALVE BEFORE THE WATER METER AND A PRESSURE GAUGE AFTER THE METER.
WATER HAMMER DEVICES PER EVERYWHERE PER SECTION 609.10 .
WATER SUPPLY CONNECTIONS TO FIXTURES OR EQUIPMENT WHICH HAVE INLETS BELOW THE SPILL LINE MUST BE PROVIDED WITH AN AIR GAP OR APPROVED BACKFLOW PREVENTER.
STATE OF MINNESOTA PLUMBING NOTES:
A ALL PLUMBING SHALL BE INSTALLED IN ACCORDANCE WITH MINNESOTA PLUMBING CODE(SEE MINNESOTA RULES,CHAPTER 4714).
•B. INDIRECT WASTE PIPES IN FOOD AND BEVERAGE ESTABLISHMENTS MUST MEET THE REQUIREMENTS OF MINNESOTA RULES,CHAPTER 4714,SECTION 801.2:
INDIRECT WASTES FROM ICE MAKERS MAY NOT BE SMALLER THAN THE DRAIN OUTLET OR'-INCH,WHICHEVER IS LARGER.
• INDIRECT WASTES FROM FOOD-HANDLING FIXTURES SHALL BE SEPARTELY TRAPPED,MAY NOT COMBINE WITH OTHER DIRECT WASTE PIPES,AND MUST DISCHARGE BY AN AIR GAP.
THE WASTE PIPE MUST NOT BE SMALLER THEN THE EQUIPMENT DRAIN OR%"-INCH,WHICHEVER IS LARGER.
* ALL OTHER IN-DIRECT WASTES MUST BEAT LEAST 1-INCH IN SIZE.
' EXCEPT THE REFRIGERATION COILS AND THE ICE MAKERS,INDIRECT WASTE LENGTH AND MAY NOT EXCEED 15 FEET.
C. WATER SUPPLY CONNECTION TO FIXTURES OR EQUIPMENT WHICH HAVE INLETS BELOW THE SPILL LINE MUST BE PROVIDED WITH AN APPROVED BACKFLOW PREVENTER(SEE
MINNESOTA RULES,CHAPTER 4714,SECTION 602.3).APPLIES TO THE RO SYSTEM,THE DISHWASHER,AND ALL APPLICABLE FOODA ND BEVERAGE EQUIPMENT.
D. HOSE THREAD OUTLETS MUST BE PROVIDED WITH ASSE 1052 NON-REMOVABLE OSE BIB-TYPE BACKFLOW PREVENTER SPILL-PROOF VACUUM BREAKERS,REDUCED PRESSURE
DETECTOR FIRE PROTECTION ASSEMBILIES,OR DOUBLE CHECK DECTECTOR FIRE PROTECTION ASSEMBLIES IS PREMITTED ONLY WITH A TEST AND INSPECTION PROGRAM
ACCEPTABLE TO THE ADMINISTRATIVE AUTHORITY IS PROVIDED(SEE MINNESOTA RULES,CHAPTER 4714,SECTION 603.5.23).THE ADMINISTRATIVE AUTHORITY AND WATER PURVEYOR
•
MUST BE NOTIFIED PRIOR TO INSTALLATION.DEVICES MUST BE TESTED UPON INITIAL INSTALLATION AND NOT LESS THAN ANNUAL,AND RECORDS KEPT.INSTALLATION MUST BE AT
•
LEAST 12 INCHES AND NOT MORE THAN 5 FEET ABOVE THE FINISHED FLOOR OR GROUND LEVEL UNLESS A PERMANENT HTTP//W WV.DLI.MN.GOV/CCLD/PDF/FS_BACKFLOW PDF
E. BEVERAGE DISPENERS:CARBONATED BEVERAGE MACHINES,AND COFFEE MAKERS MUST BE SUPPLIED THROUGH AN AIR GAP OR AN ASSE 1022 BACKFLOW PREVENTER.NO COPPER
TUBING MAY BE INSTALLED DOWNSTREAM OF THE BACKFLOW PREVENTER SERVING A POST-MIX CARBONATOR TO PRECLUDE COPPER POISIONING(SEE MINNESOTA RULES CHAPTER
414,SECTION 603.5.12).
•F. FLEXIBLE CORRUGATED COPPER OR STAINLESS STEEL FIXTURE CONNECTORS SHALL BE LIMITED TO THE FOLLOW LENGTHS(SEE MINNESOTA RULES,CHAPTER 4714,SECTION 604.12).
FIXTURE CONNECTORS MAY NOT EXCEED 30 INCHES.
• CLOTHS WASHER CONNECTORS MAY NOT EXCEED 72 INCHES.
• DISHWASHER AND ICE MAKER CONNECTORS MAY NOT EXCEED 120 INCHES.
G. THE WATER DISTRIBUTION SYSTEM SHALL BE DISINFECTED PER MINNESOTA RULES,CHAPTER 4714,SECTION 609.9.
H. . MATERIAL USED FOR THE PLUMBING SYSTEM SHALL COMPLY WITH THE STANDARDS SET FORTH IN THE MINNESOTA PLUMBING CODE(SEE MINNESOTA RULES,CHAPTER 4714 SECTION
301.1).
I. PIPE HANGERS AND SUPPORTS SHALL COMPLY WITH MINNESOTA RULES,CHAPTER 4714,SECTION 313.0 TABLE 313.1 AND THE APPLICABLE INSTALLATION STANDARD. 3-
J. VALVES SHALL BE INSTALLED PERMITTING THE WATER SUPPLY TO EACH INDIVIDUAL FIXTURE TO BE SHUT-OFF WITHOUT DISTRUPTING ANY OTHER PORTION OF THE BUILDING.AND O
ACCESSIBLE CONTROL VALVE SHALL BE INSTALLED AHEAD OF EACH SLIP JOINT CONNECTION AT A PLUMBING FIXTURE(SEE MINNESOTA RULES,CHAPTER 4714,SECTION 606.5)
.--
�� Pi- >2 c�i9 ,(�032‘''
1111 r*
�n,
I4, _
°'
f1 t i
, I; I
1541
L.11 �` a .s
II
4.,
I I1 i
,IJ ..)1/' if'll 6 a . ,
'.1, ,;),_?,..10, Thl
if 0 11
I
pr M
l , .
IT1�'ITiI
� III r
71
E
Ca r -
/ 0
0 ' ' �� ° r
0 _........
;.
_ - •lis `�'.
. 1
1 ..,3 t. ..
. : [1
, , .il
`—I TTTTEER
, �•
e...t,1, 7 VZ, / '\'\ \
\.11; ' 6,4, 7 \
X.
o� s .t 55b, '�.t A .'
'' ,/
'5,
.)Ss Ix
/ z::""F
v4,
/ / `',
\/
r � t
/ 'K U
/ y, ,. ,
0,( / / /
/
/ /
// I hereby certify that this plan, soerunderion
or report was prepared by
me my
direct supervision and that I am a duly
Registered Master Plumber under the laws
P.V�NIS �S ? of the State of Minnesota
S�0 �6 ^ S� FX r' Date: I f �-C y
o 6.0, r�t� e��1n �, Ty ' J., Signatur
License N .059398-PM