Loading...
HomeMy WebLinkAbout2019-12-20 Regulated Backflow Assembly Test Report Dec.20.2019 04:31 PM Interstate Testing 7637555365 #4018 P 3/ 3 Interstate Testing, LLC P.O. Box 55 Anoka, MN 55303 REGULATED BACKFLOW ASSEMBLY[RBA) APPLICATION FORM/'TEST REPORT COMPLETE JOB ADDRESS(INCLUDE Apt/Unit#) NAME OF BULDINO,OWNER/OCCUPANT,CONTACT NANIE AND P ENUMBER 5600 Norwich Parkway Presbyterian Homes (Boutwell Landing) Dean Evanson (612)503-7498 Oak P�rK Hgights, M1\ X06? Agan Evenson _ APPLICANT COMPANY NAME CONTRACTOR LICENSE it CONTACT NAME AND PHONE NUMBER Interstate Testing, LLC PC75175 Donp Miller (763)744-6149 ADDRESS CITY STATE ZIP EMAIL P.O. Box 55 Anoka MN 55303 interstatetesting@comcast.net TESTER NAME TESTER CEII7lFICATION# PHONE Donn Miller ,B":065323 (763)744-6149 TEST EQUIPMENT MANUFACTURER TEST EQUIPMENT MODEL a TEST EQUIPMENT SERIAL it TESTING EQUIPMENTCAUBRATION DATE Midwest Instruments 845-5 05090906 01-16-18 u `YPE OF�I O It/SND FE£;INF.OR ATION(check°o de , �,i LL Install`Relocate —Remove Replace and SNH of Replaced Device Rebuild X Test �`/�, ,. " r . BACKFLOW ASSEMBL DE AIL INF IRMArIOIV Type(check one): ,,. Reduce Pressure Principal or Pressure Principal fire Protection, — Reduced Pressure Detector Fire Protection Double Check Valve ._Double Check Detector Fire Protection ._,.,Pressure Vacuum BreakerSpill Resistant Pressure Vacuum Breaker Manufacturer:Wilkin$ Model# 950XLT Serial;# 2989315 Size:, 1" (inches) system Serviced Washing Machine Fill Location in wig Laundry Room,Behind Washing MachlneS Floor tower Level Room# Laundry > „ST REST LTrSt �:� Pass*�rRit �(CO +IPL TE APP�ICE BLE ASSEMB1 Y TYPE SFGTJoN BELOW) Pressure Differential Check Valve 112 Shutoff Valve#2 Check Valve#1 Relief Valve Initial. Closed Tight „ Yes ,..No Closed Tight Yes No Closed Tight _.,Yes . No. Test Opened at psid Pressure Drop Across Check Valve#1, psid final Closed Tight ___Yes_No dosed Tight Yes No Closed Tight .,.,.'Yes_,_,,,No Opened at psid Test Pressure Drop Across Check Valve ml psid • aeu e' hei k vh nr,�o a t eck a+ x 1Ftir+�Pl'tltect qn s1' Irsu>7 Check Valve 41 Check Valve 42 Shutoff Valve tit Initial Test dosed Tight ,Les No 2.4 psid Closed Tight Yes No 1,6 psid Closed Tight , Yes No Final Test Closed light Yes _No psid Closed Tight -„-, YesNo psidTight Yes No Closed Qsat)t act Wh.8rea1t ` p1rl "lift S' i11 Rk i5t 11 �l3 Ili lr►8't Oker 5 V 5t ftl SUL'7S , Air inlet Valve Check Valve Shutoff#2 Initial Test Failed to Open_Yes No Closed Tight Yes _No Opened at .psid Pressure Drop Across Check Valve Hi psid Closed Tight Yesr No AnTest Opened at psid Closed Tight Yes_ No Pressure Drop Across Check Valve#1,.�r�psld Tight Yes.._. No Describe parts and repairs when needed: 1 r r l CERTIFICATION/ I hereby certify the foregoing Infomiatlon provided by me to rect and that the teste d 'cc is functioning in compliance with State of Minnesota Plumbing Code,Chapter4714, TESTER'S SfGNATIJRE TE5T DATE: 12-2Q-19