Loading...
HomeMy WebLinkAboutFP 2019-00249 Kitchen Remodel CITY OF OAK PARK HEIGHTS 1111111111 11111111H 14168 OAK PARK BLVD N. OAK PARK HEIGHTS, MN 55082- * 2 0 1 9 - 0 0 2 4 9 * (651) 351-1661 FAX: (651) 439-0574 ISSUED: 10/03/2019 Permit #: 2019-00249 ADDRESS : 12585 58TH ST N PIN : 06.029.20.12.0024 LEGAL DESC : OAK PARK STATION SECOND ADDITION : LOT 1 BLOCK 1 PERMIT TYPE : FIRE PROTECTION PROPERTY TYPE : COMMERCIAL CONSTRUCTION TYPE : FIRE PROTECTION VALUATION : $ 900.00 NOTE: PERMIT ISSUED FOR INSTALLATION OF AN ANSUL 3.0 GALLON(R102)UNIT AS PART OF KITCHEN REMODEL PROJECT AT KWIK TRIP. WORK SHALL BE PER MANUFACTURER SPECIFICATION AND PRODUCT STANDARDS AND SHALL COMPLY WITH MN CODE AND LOCAL ORDINANCES. FIRE MARSHAL MIKE BELL TO BE CONTACTED FOR INSPECTION @ 651.724.1577 APPLICANT FIRE PROTECTION BASE FEE 35.70 FIRE PROTECTION PLAN REVIEW 23.21 SUMMIT FIRE PROTECTION STATE SURCHARGE-BUILDING 0.45 575 MINNEHAHA AVE. W. ST. PAUL,MN 55103- TOTAL 59.36 (651)251-1880 Payment(s) Minnesota State License#:C075 CHECK 054453 59.36 OWNER KWIK TRIP INC 1626 OAK ST. P.O. BOX 2107 LA CROSSE,WI 54603- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to: (1)the conditions of this permit;(2)the approval plans and specifications;(3)the applicable city approvals,Ordinances,and Codes;and,(4)the State Building Code.This permit is for only the work described,and does not grant permission for additional or related work which requires separate permits.This permit will expire and become null and void if work is not started within 180 days,or if work is suspended or abandoned for a period of 180 days any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the Minnesota State Building Code. SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. 4,4-L.A..) 0 I ► 0 kid..--1 NOTES --� Hood FJa -� - / - FIELD PIPE DROPS AS SHOWN c 9 00 SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, 0 ,,°•-_____4,714. 1 J SALAMANDERS, ETC, 51124.00 A, a,00• 1 - MAXIMUM 9 ELBOWS IN SUPPLY LINE. a I - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE-PIPED CHARBR❑ILER DROPS ARE SHIPPED LOOSE, - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE Hd6=1 -t-(tH.. -��-rt r9�e6r9 - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE Model. DD-24 ;iG xsa SIZE, NOT THE OVERALL APPLIANCE SIZE, &m th, g 6' IIc gd Front - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS Job #1 3932679 Job Name Kwik Trip #111, 401+3, #, $ tw System Sizes ANSUL-3,0-WC Total FP required 8 —21,00•--2100 — Hood 4 1 3' 6.00' Long x 36' Wide x 50' High Riser # 1 Size! 10' Dia, E 3 -} I Hood # 1 Metal Blow-Off Cps Icluded. I OOLEGEND - FIRE CABINET ANSUL SYSTEM --al.fbo•--13,00•— ® Fo tt 1A 1.5 GALLON TANK 1B 3 GALLON TANK 2 OEM AUTOMAN RELEASE 3 OEM REGULATED RELEASE BN 3N 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (1.5 GAL.) FACTORY PIPING 7 CARTRIDGE (101-20) 8 CARTRIDGE (101-10) 9 CARTRIDGE (101-30) — — FIELD PIPING 9A CARTRIDGE (LT-A-101-30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK . 11 DOUBLE MICROSWITCH 0 0 / 12 HOSE ASSEMBLY a A a A IPII 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) t>S rano xm =?� 1W NOZZLE ASSEMBLY (419336) z0 1F NOZZLE ASSEMBLY (419333) T.a, Ld ' 1N NOZZLE ASSEMBLY (419335) TS Two 1/2N NOZZLE ASSEMBLY (419334) '�n =B 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REMOTE MANUAL PULL STATION S SWIVEL ADAPTOR