Loading...
HomeMy WebLinkAbout2020-03-13 Ahern Annual Sprinkler Inspection Report ,3705 26'" Avenue, Suite 110 Sprinkler Inspection Minneapolis, MN 55441 main 763.268.0515 fax 763.268.0516 Annual HERN E www . ahernfire . com Work Order: 1338828 Agreement: 36071 Inspection Start Date : 03/13/2020 Customer PO: SC-2003-0070-1-4 Inspection Location Contact: Greg Inman Goodwill Easter Seals Cell#: (612)221.7367 5980 Krueger Lane N Phone#: (763) 591.5588 Oak Park Heights MN 55082 E-Mail: gsinman@eganco.com Cust ID: 101250 Loc ID: 032 Check Valve Qty: 1 Status: Complete Eq ID: 032-CHKVLV2 Customer System ID Manufacturer ID Unknown Model ID U Size 4" Location In Buildin• NE corner Question Result 10 What date was the last internal ins section serformed on the check valve? 2017-04-01 Bldg/Ovvner Questions SP 032-GENSPQUES1 -General SP Questions Qty: 1 Status: Corn.lete E. ID: 032-SPBOQUESI Question , Result 0� Did owner verify that there is adequate heat(40°F min.)in all areas with water-filled Yes i.in ? Check Valve 032-GENSPQUESI -General SP Questions Qty: 1 Status: Corn lete E. ID: 032-CHKVLV1 Customer System ID Manufacturer ID deringer Model ID 20 Size 4" Location In Building riser room Question Result 10 What date was the last internal inspection performed on the check valve? 2017-04-01 Fire Department Connection 032-GENSPQUESI -General SP Questions Qty: 1 Status: Complete Eq ID: 032-FDC1 FDC Type Wall Exposed Size 5x4 Storz Location In Building NE corner Question Result 10 Is the F.D.C.Visible and Accessible? Yes 20 Are the plugs and caps in place and undamaged? Yes 30 Are couplings and swivels free of damage and rotate smoothly,are gaskets in place and in Yes good condition,are identification signs in place? 40 Is the F.D.C. Check Valve free of Leaks,is the automatic drain valve in place and Yes operating properly,are the clappers in place and operating properly? Sprinkler Questions 032-GENSPQUESI -General SP Questions Qty: 1 Status: Complete Eq ID: 032-SPQUESI Question Result 10 Gauges in good condition and showing normal water or air pressure? Yes 20 At the time of inspection,was there adequate heat(40°F min.or 70°F min. for diesel NA Thomas D Yorkson Page 1 of 3 pumps without engine heater)in all valve and pump houses? 50 Hydraulic nameplate(calculated systems only) securely attached to riser and legible? Yes 60 Alarm devices free from mechanical damage? Yes 100 Date gauges were last tested with calibrated gauge or replaced? 2017-04-01 110 System information sign legible and securely attached to riser supplying an antifreeze loop, NA dry system,preaction system,or auxiliary system control valve? 130 Visible pipe hangers and seismic braces free from damage and securely attached? Yes 140 Visible pipe and fittings free from mechanical damage,leakage,and external corrosion? Yes 150 Visible piping free from external loads? Yes 155 Has any heat tape on sprinkler piping been inspected per manufacturer's requirements? NA 160 Date of last internal inspection of the piping? 2017-04-01 170 Visible sprinklers free from leakage,corrosion,foreign materials,paint,and physical No DEF damage? 180 Visible sprinklers installed in the proper orientation? Yes 190 Liquid in all visible glass bulb sprinklers? Yes 200 Minimum clearance being maintained below all sprinklers? .Yes 220 Proper number and type of spare sprinklers and wrenches?— " — Yes 230 Visible sprinklers dated 1920 or later? Yes 240 Fast response sprinklers 20 or more years old replaced or successfully sample tested NA within last 10 years? 250 Standard response sprinklers 50 or more years old replaced or successfully sample tested NA within last 10 years? 260 Standard response sprinklers 75 or more years old replaced or successfully sample tested NA within last 5 years? 270 Extra high temperature solder-type sprinklers or sprinklers in corrosive environments NA replaced or successfully sample tested within last 5 years? 280 Dry sprinklers replaced or successfully sample tested within last 10 years? NA Valve Inspection Record o x U 4.7 w O .4 cn v 'y y Qcu O. O yH to aiz �, i. O es et x o Valve ID Valve Type Size Secured A 4-' 4 H a w a Control Valve AF Check Butterfly 4" Supervised Yes Yes N/A Yes Yes Yes N/A Control Valve BF Check Butterfly 4" Supervised Yes Yes N/A Yes Yes Yes N/A Water Flow Alarm Tests System Number Time to Alarm(sec.) Results acceptable? Flow Switch 50 Yes Main Drain Tests System Number Static Pressure Residual Pressure Time for Pressure Size of Drain Are test results Before Test(P.S.I.) (P.S.I.) to return to acceptable? original(sec) Main Drain 65 58 2 2 Yes Thomas D Yorkson Page 2 of 3 Deficiency Recap: 032-SPQUES1-Sprinkler Questions 032-GENSPQUES1-General SP Questions Question ID: 170 Task: Annual Location: Question: Visible sprinklers free from leakage,corrosion,foreign materials, No paint,and physical damage? Tech Notes There is(1)upright head in loading dock area that has tape on it.This should be able to be removed with a 12' ladder Deficiency NFPA 25-2011 Edition Section: 5.2.1.1.2 Authority Any sprinkler that shows signs of any of the following shall be replaced: (1)Leakage(2) Corrosion(3)Physical damage(4)Loss of fluid in the glass bulb heat responsive element(5) Loading(6)Painting unless painted by the sprinkler manufacturer Additional Notes: No Additional Notes NOTES: Any backflow preventers tested as part of this inspection were tested in accordance with all applicable state rules and regulations and all readings are true and accurate to the best of my knowledge. Any comments or findings in this inspection report are not in any way to be considered a fire protection engineering review. All fire protection system inspection and testing,as contracted with Customer is performed to the following NFPA codes and editions (listed as code-edition);10—2013,11-2005,12-2008,12A-2004,16-2007,17-2013,17A—2013,25-2011,72-2010,96— 2014,409-2011,750-2006,1962—2013,2001—2008 and Life Safety 101 (Chapter 7)-2012. Inspection Contractor: AFP Twin Cities Service 13705 26th Ave Minneapolis,MN 55441-3635 Building Owner or Authorized Representative: Technician: Signature: Signature: Name: Thomas D Yorkson Name: Greg Inman License#: Customer Signature 03/13/2020 Inspection 03/13/2020 Date: End Date: This inspection report is expressly subject to the terms and conditions of sale located at JF Ahern Terms and Conditions which are incorporated by reference as if fully set forth herein.By accepting this inspection report you are deemed to have read,understood and accepted the electronic terms and conditions of sale. An experienced Fire Protection professional will be contacting you shortly to discuss how we might help eliminate any deficiencies identified in this inspection. This document is the property of the inspecting entity.Copyright J.F.Ahern Co/Ahern Fire Protection. REPRODUCTION IN ANY FORM VIOLATES COPYRIGHT. Thomas D Yorkson Page 3 of 3