Loading...
HomeMy WebLinkAboutELE 2020 ELE2007-001924 Accessory Structure Electrical Permit rylli DEPARTMENT OF 443 Lafayette Road N., St. Paul, MN 55155 LABOR AND INDUSTRY (651) 284-5026, www.dli.mn.gov Electrical Permit Permit Number: ELE2007-01924 Permit Information as of 07/07/20 Structure Type: One-Family Home I Existing Home or Other Items Permit Status: Issued Site County: Washington County Issued Date: 07/07/20 Site Address: 5714 Penrose Ave N, Oak Park Heights, MN 55082 Expiration Date: 07/07/21 Fees Paid: $406.00 Permit Applicant Information Irwin turner Phone: (651) 470-3545 5714 penrose ave n., Oak Park Height, MN 55082 Email: lturner0722@yahoo.com Contracted Electrical Inspector's Information Name: Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Addres: mailto: don.edel.inspections@gmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough-In Inspection Required: Yes Number of Inspections Requested: 2 Directions to Job Site: 5714 Penrose Avenue North Oak Park Heights Backyard detached 2 car garage Project Description: electrical wiring to garage New construction of detached garage in back yard. I will be installing wiring from house to garage. Two courtesy lights on outside of garage. Two electric outlets on outside of garage. There will also be some electrical outlets on inside of garage with some ceiling lights. Quanity of circuits is 12 with 100 amp breaker box. A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. zJ Print Date: 07/07/2020 niDEPARTMENT OF 0 : ' 03 LABOR AND INDUSTRY } !' •.i Inspection Report Project Name: electrical wiring to garage Permit Number: ELE2007-01924 Project location/address: 5714 Penrose Ave N, Oak Park Heights, Washington County, MN, 55082 Applicant: Irwin turner Phone: (651) 470-3545 Inspection Type: Final Result: Pass Inspector Report new garage panel and 4-circuits (final) Inspected By: Donald Edel Email: don.edel.inspections@gmail.com Phone: (507) 210-8233 Date: 7/30/2020 443 Lafayette Road N., St. Paul, MN 55155 (651) 284-5005 I www.dli.mn.gov DEPARTMENT OF LABOR AND INDUSTRY .' ' '. Inspection Report Project Name: electrical wiring to garage Permit Number: ELE2007-01924 Project location/address: 5714 Penrose Ave N, Oak Park Heights, Washington County, MN, 55082 Applicant: Irwin turner Phone: (651) 470-3545 Inspection Type: Rough-In Result: Corrections Required Inspector Report Trench ok Garage not completed Wr required, tr required, boxes required for ext fixtures, 2 rods required, nm not allowed undrground in raceway Inspected By: Braden Trende Email: bj@trendeelectric.com Phone: (763) 232-7569 Date: 7/16/2020 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 www.dli.mn.gov DEPARTMENT OF Or2%. LABOR ANDI � , Inspection Report Project Name: electrical wiring to garage Permit Number: ELE2007-01924 Project location/address: 5714 Penrose Ave N, Oak Park Heights, Washington County, MN, 55082 Applicant: Irwin turner Phone: (651) 470-3545 Inspection Type: Rough-In Result: Corrections Required Inspector Report garage service and (rough-in) (THE GARAGE RECEPTACLES NEED TO BE GFCI PROTECTED) THE FEEDER FROM THE HOUSE TO THE GARAGE MUST HAVE A GROUND WIRE (FOURTH WIRE) INSTALLED WITH THE OTHER (3) CONDUCTORS NEC 250.32, Detached buildings or structures supplied by a feeder or branch circuit shall have an equipment grounding conductor installed with the supply conductors and connected to the grounding electrode system at the building or structure. 2017 NEC 210.8, The ground-fault circuit-interrupter shall be installed in a readily accessible location. Ground-fault circuit-interrupter (GFCI) protection shall be provided for all 125-volt, 15- and 20-amp receptacle outlets installed outdoors, in boathouses, crawl spaces, unfinished basements, laundry areas, garages, accessory buildings, bathrooms, at kitchen countertops and within 6-feet of the top inside edge of all sink bowls, and within 6-feet from the outside edge of bathtubs and shower stalls. GFCI protection shall be provided for all lighting outlets installed in crawl spaces. GFCI protection shall be provided for all dishwashers; permanently connected or cord-and-plug connected. Inspected By: Donald Edel Email: don.edel.inspections®gmail.com Phone: (507) 210-8233 Date: 7/27/2020 443 Lafayette Road N., St. Paul, MN 55155 I (651) 284-5005 I www.dlLnn.gou