HomeMy WebLinkAbout2021-02-11 Fire Alarm Inspection & Testing Report www.nardinifire.com / sales@nardinifire.com FIRE ALARM INSPECTION AND TESTING Service Order Number: Work Site #: Date In: Time In: Date Out: Time Out: 1. PROPERTY INFORMATION Name of property: Address: Description of property: Name of property representative: Address: Phone: Fax: E-mail: 2. TESTING AND MONITORING INFORMATION Testing organization: Address: Phone: Fax: E-mail: Monitoring organization: Address: Phone: Fax: E-mail: Means of transmission: Account number: Phone line 1/IP address: Phone line 2/IP address: Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE 4.1 Control Unit Manufacturer: Model number: 4.1.1 Circuit Styles: 4.1.2 Number of Circuits: 4.1.3 Panel Locations: Firmware revision number: 4.1.4 Was Firmware Updated? Yes No Comments: Does Alarm Panel Have Most Updated Firmware? Yes No Comments: 4.3.1 Primary (Main) Power Nominal voltage: Amps: Location: Overcurrent protection type: Amps: Disconnecting means location: 4.3.2 Secondary Power Type: Location: Battery type (if applicable): Calculated capacity of batteries to drive the system: In standby mode (hours): In alarm mode (minutes): FACP AMERICINN BY WYNDHAM 39053 2/11/2021 OAK PARK HEIGHTS, MN 55082 651-483-6631 SLC Circuit breaker OAK PARK HEIGHTS, MN 55082 3pm ST00182945 13025 60TH STREET N 7100-2D Nardini Fire Equipment 12:30pm Sealed lead acid PATEL, ROSHNI St. Paul, MN 2/11/2021 651-275-1230 13025 60TH STREET N 1 PP11 ckt #43 2 12v5ah 09/2019 405 Cty Rd E west St Paul MN 55126 651-275-4027 FCI POTS Front entry sales@nardinifire.com 20 651-275-0980 Hotel 120VAC www.nardinifire.com / sales@nardinifire.com FIRE ALARM INSPECTION AND TESTING 5. NOTIFICATIONS MADE PRIOR TO TESTING Monitoring organization Contact: Time: Building management Contact: Time: Building occupants Contact: Time: Authority having jurisdiction Contact: Time: Other, if required Contact: Time: 6. TESTING RESULTS 6.1 Control Unit and Related Equipment Description Visual Inspection Functional Test Comments Control Unit Lamps/LEDs/LCDs Fuses Trouble Signals Disconnect Switches Ground-Fault Monitoring Supervision Local Annunciator Remote Annunciators Remote Power Panels Elevator Recall Shunt Trip Door Holder Area of Refuge Silent knight Management 12:30pm 12:30pm www.nardinifire.com / sales@nardinifire.com FIRE ALARM INSPECTION AND TESTING 6.2 Power Supplies Power Supply Location Battery Condition Discharge Test Charger Test Comments 6.3 Secondary Power Location: Description Visual Inspection Functional Test Comments Battery Condition Discharge Test Charger Test FCI FC-5495 Good (2) 12v7ah dated 2/2020GoodElectrical room Good In facp www.nardinifire.com / sales@nardinifire.com FIRE ALARM INSPECTION AND TESTING 6.4 Alarm and Supervisory Initiating Device Description Quantity Functional Test Comments Manual Pulls Smoke Detectors Heat Detectors Flame Detectors Beam Detectors Wet Water Flow Dry Water Flow Aspirating Smoke Detection Duct Detector Sprinkler Tamper (Supervisory) Sprinkler Low/High (Supervisory) CO Detector Building Temperature Fire Pump Running Fire Pump Phase Fail Fire Pump Phase Reversal Fire Pump Trouble Kitchen System Gas Detectors Other 6.4.1 Aspirating Smoke Detection NAME MFG MODEL FILTER DATE AMBIENT % ACTION ALERT ALARM 1 ALARM 2 TRANSPORT TIME 3 Escape tested Visual inspection only 1 1 Escape tested Escape tested 20 2 Escape tested 6 1 www.nardinifire.com / sales@nardinifire.com FIRE ALARM INSPECTION AND TESTING 6.5 Notification Appliances Description Quantity Functional Test Comments Horn/Strobe Horn Strobe Speaker Chime Other 6.5.1 Number of Alarm Notification Circuits___________ 6.6 Supervising Station Monitoring Description Yes No Time Comments Alarm Signal Alarm Restoration Trouble Signal Trouble Restoration Supervisory Signal Supervisory Restoration 7. COMMENTS 8. NOTIFICATIONS THAT TESTING IS COMPLETE Monitoring organization Contact: Time: Building management Contact: Time: Building occupants Contact: Time: Authority having jurisdiction Contact: Time: Other, if required Contact: Time: 9. SYSTEM RESTORED TO NORMAL OPERATION Date: Time: 10. NARDINI FIRE TECHNICIAN Printed Name: Printed Name: 11. CUSTOMER SIGNATURE Printed Name: Signature: 50 3pm 3pm 12:30pm 16 Piezo Management 4 6 12:30pm Silent knight Red tag system, smoke detector in south lobby not working John Lo 3pm 2/11/2021 3pm 3pm 3pm 12:30pm