HomeMy WebLinkAboutPL 2021-00018 Remodel - Skopko Optical CITY OF OAK PARK HEIGHTS 1111111111111111111 111 14168 OAK PARK BLVD N. OAK PARK HEIGHTS, MN 55082- * 2 0 2 1 - 0 0 0 1 8 * (651)351-1661 FAX: (651) 439-0574 ISSUED: 02/01/2021 Permit #: 2021-00018 ADDRESS : 13189 60TH ST PIN : 05.029.20.22.0019 LEGAL DESC : BRACKEY 4TH ADDITION : LOT 1 BLOCK I PERMIT TYPE : PLUMBING PROPERTY TYPE : COMMERCIAL CONSTRUCTION TYPE : REMODEL ACTIVITY : TENANT SPACE PLUMBING BUILD OUT VALUATION : $ 16,400.00 NOTE: CONSTRUCT PER APPROVED PLAN&MN LID REVIEW LETTER PB-R2012-0133-APPROVAL DATE 12-29-2020. WORK SHALL COMPLY WITH MN STATE CODE&LOCAL ORDINANCE REQUIREMENTS. VALUE OF PLUMBING 16400 APPLICANT PLUMBING-COMMERCIAL 164.00 PLUMBING STATE SURCHARGE COMMERCIAI 8.20 VOSS UTILITY& PLUMBING LICENSE VERIFICATION 5.00 885 KATYDID LANE TOTAL 177.20 ST. MICHAEL, MN 55376- (763)4974577 Payment(s) CHECK 037471 177.20 OWNER KRUEGER LANE LLC 4999 FRANCE AVE STE 216 MINNEAPOLIS, MN 55410- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to: (1)the conditions of this permit;(2)the approval plans and specifications;(3)the applicable city approvals,Ordinances, and Codes;and,(4)the State Building Code. This permit is for only the work described,and does not grant permission for additional or related work which requires separate permits. This permit will expire and become null and void if work is not started within 180 days,or if work is suspended or abandoned for a period of 180 days any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the Minnesota State Building Code. SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. DEPARTMENT OF LABOR AND INDUSTRY Division of Construction Codes and Licensing REPORT ON PLUMBING PLANS PROJECT: Shopko Optical Oak Park Heights, 13189 60th Street North,Oak Park Heights, Washington County, Minnesota,Plan No. PB-R2012-0133 OWNERSHIP: Shopko Optical, c/o Mr. Tony Minino, 700 Pilgram Way, Green Bay, WI 54304 SUBMITTER: Destinee Higdon, 604 Courtland Street,Orlando,FL 32804 Plans Dated: December 8,2020 Initial Date Received: December 18,2020 Last Date Received: December 18, 2020 Date Approved: December 29,2020 This review is limited to the provisions of the Minnesota Plumbing Code,Minnesota Rules,Chapter 4714 and assumes the data on which the design is based are correct. Approval is contingent upon meeting the requirements listed below. A copy of the approved plans and this report must be retained at the project location. INSPECTIONS: This project will be inspected by the local municipality. The contractor/installer must obtain all required inspection permits from the Oak Park Heights Building Official, Julie Hultman. All plumbing installations must be tested and inspected in accordance with the requirements of the Minnesota Plumbing Code. No plumbing work may be covered prior to inspection. REQUIREMENT(S): 1. All plumbing shall be installed in accordance with Chapter 4714. All pipe, fittings,traps,fixtures, materials, and devices shall be listed or labeled by a third-party listing agency and comply with the applicable standards referenced in the code(see Sections 301.1 and 1401.1). 2. The new water distribution branch must connect to an existing branch of at least I-inch in size an in no case smaller than will meet the requirements of Section 610. 3. Double wyes may not be used for drainage fittings in the horizontal position(see Section 310.5). Proper pipe slope cannot be maintained on both of the offset branches. 4. Trap primers must have an ASSE 1013 reduced pressure principle backflow preventer; an ASSE 1020 pressure vacuum breaker; an ASSE 1056 spill-proof vacuum breaker; or an ASSE 1001 atmospheric vacuum breaker with no shutoff valve downstream(see Table 603.2). Trap primers with integral backflow prevention are permitted only when equipped with one of the above-listed backflow preventers. 5. A hose thread water outlet without listed integral backflow prevention must be provided with an ASSE 1052 non-removable hose bibb-type backflow preventer; an ASSE 1011 non-removable hose bibb type vacuum breaker; or an ASSE 1001 atmospheric vacuum breaker on the discharge side of the last control valve at least 6 inches above the highest point of usage(see Sections 603.5.7,603.4.6, and 301.1.2). This shall include the laundry tub faucet. 6. The water heater relief valve may not discharge to the pan. 7. The installation of reduced pressure principle assemblies,double check valve assemblies,pressure vacuum breakers,or spill-proof vacuum breakers is permitted only when a testing and inspection program acceptable to the administrative authority is provided (see Section 603.5.23). The administrative authority and water purveyor must be notified prior to installation. Devices must be tested upon initial installation and not less 443 Lafayette Road N., St. Paul, MN 55155 • (651) 284-5005 • www.dli.mn.gov An Equal Opportunity Employer Shopko Optical Oak Park Heights Plumbing Plan No. PB-R2012-0133 Page 2 of 3 December 29,2020 than annually,and records must be kept. Installations must be at least 12 inches and not more than 5 feet above the finished floor or ground level unless a permanent platform for access is provided. A backflow prevention fact sheet may be viewed at: http://www.dli.mn.gov/sites/default/files/pdf/fs backflow.pdf 8. Public-use lavatories must have ASSE 1070-2004 mixing valves limiting the hot water temperature to 110 degrees Fahrenheit or less(see Section 421.2). 9. The water closets must have open-front seats or automatic seat cover dispensers(see Section 411). 10. Unions shall be installed not more than 12 inches from water heating or regulating equipment,water conditioning tanks,and similar equipment requiring service by removal or replacement(see Section 609.5). 1 I. All sanitary drainage pipe must be sloped at 1/4-inch per foot minimum(see Section 708.1). Where site conditions preclude this slope,pipes 4-inch and larger may be sloped at '/-inch per foot where approved by the administrative authority. 12. Each horizontal drain branch on the lowest floor level of the building, including floor drain branches,shall be provided with a cleanout at its upper terminal. Cleanouts are not required on branches less than five feet, unless sinks or urinals are served(see Section 707.4). 13. A cleanout is necessary where new waste and vent piping connects with existing for testing. 14. Pipe materials used in the plumbing system must meet the following: a. Water distribution piping must comply with applicable standards in Table 604.1: i. Copper water distribution pipe must meet ASTM B42,B75,B88,B251,B302,or B447 (see Table 604.1). Solder and flux shall contain less than 0.2 percent lead. Joints must use ASTM B813 non-corrosive non-toxic paste-type flux(see Section 605.3.4). ii. Cross-link polyethylene(PEX)water distribution systems must meet Section 605.10: a. The tubing must comply with ASTM F876,ASTM F877,or CSA B137.5. b. ASTM F876 tubing must be marked with the standard of the fittings to be used. c. The fittings must be marked with ASSE 1061,ASTM F877,ASTM F1807,ASTM F1960,ASTM F1961,ASTM F2080,ASTM F2159,ASTM F2735,or CSA B137.5. iii. CPVC water distribution systems must meet Section 605.4: a. Pipes must meet ASTM Standards D2846, F441,or F442. b. Solvent cement must comply with ASTM F493. Solvent cement requiring the use of primer must be orange. Primer must meet ASTM F656 and be colored. One-step yellow or red solvent cement is permitted for'/2-inch through 2-inch ASTM D2846 pipes only. c. Installation Standard 20 must be followed,including provisions for expansion and contraction. b. Drain,waste,and vent piping must comply with Table 701.1. If plastic pipe is used: i. ABS must meet ASTM D1527, D2661, F628,or F1488 per Installation Standard 5. ii. PVC must meet ASTM D1785, D2665, F891,or F1488 per Installation Standard 9. iii. Above-ground horizontal pipes must be supported at each horizontal branch connection. Restraint fittings or a minimum 24-inch offset using 45-degree fittings should be provided every 30 feet. Vertical runs exceeding 30 feet may have approved expansion joints installed per the manufacturer's instructions. iv. PVC solvent weld joints must use ASTM F656 purple primer and ASTM D2564 solvent cement. Future submittals must include material specifications. Shopko Optical Oak Park Heights Plumbing Plan No. PB-R2012-0133 Page 3 of 3 December 29,2020 15. The plumbing system shall be tested in accordance with Sections 609.4 and 712.0. 16. The water distribution system shall be disinfected in accordance with Section 609.9. NOTE(S): 1. The scope of this project consists of the remodelling of an existing building. The plumbing installation includes a water closet,a lavatory,a laundry tub, four counter sinks,and a drinking fountain. 2. This facility will be served by existing municipal water and sewer services. 3. The current Minnesota Plumbing Code, Chapter 4714, and related information can be found at: http://www.dli.mn.gov/business/plumbing-contractors/2015-minnesota plumbing-code Authorization may be withdrawn if installation does not begin within one year. Additional requirements may result from changed conditions or additional information. Approved: Bradley C. Erickson Public Health Engineer Plumbing Plan Review and Inspections Unit http://www.do li.state.mn.us/business/get-licenses-and-permits/plumbing-plan-review bradley.erickson@state.mn.us 651/284-5880 cc: Interplan LLC Shopko Optical Julie Hultman,Building Official File