Loading...
HomeMy WebLinkAbout2021-04-21 Nardini Fire Equipment Testing Report Nardini FIRE EQUIPMENT . www.nardinifire.com/sales@nardinifire.com ENGINEERED SYSTEM INSPECTION AND TESTING REPORT Work Site#: 24708 Service Order#: ST00188447 Name of Facility: XCEL SUBSTATION--ALLEN KING \ Installation/Service Report Date: 04/21/2021 Street: 5701 N ST CROIX TRAIL L 1 C) 7J V,U) Plan G 17--ei ) Time In: 8:45 Time Out: 9:45 City: OAK PARK State: MN Zip: 56357 Last Maintenance Date: 10/21/2020 Installation 0 Authorized Contact: EDDY,ANGELA Last - IR 0 Maintained By: Nardini Semi Semi-AAlynnual, Phone: 9528874575 Annual 0 Suppression Type Panel Type Manufacturer of System: Pyro-Chem Manufacturer: Ansul Revision: Type of Agent: ABC Dry Chem Model: AutoPulse Z-10 Intelligent 0 Conventional Chip#: System Location: Generator Electrical Disconnect Location: CKT#13 Hazard Description: Generator Manual Release Operable? Yes ® No 0 Qty:( 1 ) Alarms Operable? Yes ® No 0 Abort Operable? Yes 0 No 0 Qty:( 0 ) Lockout Valve? Yes 0 No 0 N/A El Bypass Switch Operable? Yes ® No 0 Qty:( 1 ) Odorizer? Yes 0 No 0 N/A El Actuator Operable? Yes ® No 0 Date: CO2 cartridge daiType: ECH3 Time Delay? Yes ® No 0 N/A 0 Auto Detection Operable? Yes ® No 0 Discharge Hose Date: Detection Type: Photo( ) Heat( 1 ) Temps: 165 Optical Flame( ) Aspirating( ) Ion( ) Other( ) Notification Type: Bells ( ) Horns( ) Horn/Strobes( 2 ) Strobes( ) Other( ) Model: System Sensor Auxiliary Functions Relay Press Low High Tested Batteries Switch Volt Volt Shutdown Equipment 0 Ei ® 0 _ _i Size Qty: Date(s) Shutdown Ventilation 0 ® ® 0 ® 12v 7ah 2 5-2019 Shutdown Dampers 0 ® ® 0 _ El Building/Local Alarm Tie-In 0 ® ® 0 El Load Test: Pass Panel Transfer to Battery? Yes® No 0 Charger Test: Pass Type of Release: Single Zone( X ) Cross Zoned( ) Counting Zone( ) Other( )Discharge Delay- 0 Seconds ELECTRIC Sequence of Operations: 1S1 Alarm- H/S 2nd Alarm- Discharge- H/S Abort Delay- N/A Seconds Perimeter Doors Sealed Yes ® No 0 Ceiling Tiles Clipped Yes 0 No 0 N/A El Warning Signs Yes ® No 0 Hazard Changes Yes 0 No ® N/A 0 Checked Hazards for Leaks Yes ® No 0 Nozzles Clearance(8"dia.) Yes ® No 0 N/A 0 Is actuator on cylinder and strapped? Yes 0 No ® Serial#: Comments: System tested normal Joel Hoffman Xx Nardini Fire Technician(s) Customer/Authorized Agent—Printed Name Customer/Authorized Agent—Signature ar ini FIRE EQUIPMENT www.nardinifire.com/sales@nardinifire.com Aspirating Smoke Detection FILTER TRANSPORT NAME MFG MODEL DATE AMBIENT% ACTION ALERT ALARM 1 ALARM 2 TIME r4. ar ini FIRE EQUIPMENT www.nardinifire.com/sales@nardinifire.com Tanks SERIAL NUMBER FILL WT. GROSS WT. ACT.WT.ILL TEST DATE PSIG VALVE MODEL 1. ATM736254 35 7-2018 340 Pyro-Chem 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54.