Loading...
HomeMy WebLinkAboutBP 2021-00089 - Electrical Permit & Inspection ReportsMDEPARTMENT OF LABOR AND INDUSTRY 443 Lafayette Road N., St. Paul, MN 55155 (651) 284-5026, www.dli.mn.gov Electrical Permit �P -aoa i - 00089 Permit Number: ELE2103-10372 Permit Information as of 03/31/21 Structure Type: One -Family Home I Existing Home or Other Items Permit Status: Issued Site County: Washington County Issued Date: 03/31/21 Site Address: 5660 Oak Cove N, Stillwater, MN 55082 Expiration Date: 03/31/22 Fees Paid: $60.00 Permit Applicant Information Natalie Sintek Mobile: (651) 324-3246 5660 Oak Cove N, Oak Park Heighs, MN 55082 Email: nataliesintek@gmail.com Contracted Electrical Inspector's Information Name: Donald Ede] Phone: (507) 210-8233 Don Edel Inspections LLC Email Addres: mailto: don.edel.inspections@gmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmnC:xcelenergy.com Rough -In Inspection Required: No Number of Inspections Requested: 1 Directions to Job Site: On the corner of Oakgreen Ave and Oak Park Rd Project Description: adding outlets to flex space Adding 4 250 -volt GFCI receptacle and outlets, replacing light fixture, adding new light fixture. This home was finished in 2021 and was built fully to code, this project will be finishing the flex space an office/ meditation space and is currently roughed in. A rough -in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 03/31/2021 DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: adding outlets to flex space Permit Number: ELE2103-10372 Project location/address: 5660 Oak Cove N, Stillwater, Washington County, MN, 55082 Applicant: Natalie Sintek Inspection Type: Partial Final Phone: (651) 324-3246 Result: Corrections Required Inspector Report Adding 4 250 -volt GFCI receptacle and outlets, replacing light fixture, adding new light fixture. This home was finished in 2021 and was built fully to code, this project will be finishing the flex space an office/ meditation space and is currently roughed in. (the NM cables entering the switch box require listed connectors to be installed) (the NM cables must be strapped within 12 inches of the box) NEC 334.30, Nonmetallic -sheathed cable shall be supported and secured by staples; cable ties listed and identified for securement and support; or straps, hangers, or similar fittings designed and installed so as not to damage the cable, at intervals not exceeding 4 1/2 -feet and within 12 -inches of every cable entry into enclosures such as outlet boxes, junction boxes, cabinets, or fittings. The cable length between the cable entry and the closest cable support shall not exceed 18 -inches. Flat cables shall not be stapled on edge. NEC 314.17, Where raceway or cable are installed, the raceway or cable shall be secured to the boxes. Correct the noted deficiencies. Reinspection will be made at the time of the final inspection. Inspected By: Donald Ede[ Phone: (507) 210-8233 Email: don.edet.inspections@gmail.com Date: 6/29/2021 443 Lafayette Road N., St. Paul, MN 55155 ( (651) 284-5005 1 www.dii.mn.gov DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: adding outlets to flex space Permit Number: ELE2103-10372 Project location/address: 5660 Oak Cove N, Stillwater, Washington County, MN, 55082 Applicant: Natalie Sintek Phone: (651) 324-3246 Inspection Type: Final Result: Pass Inspector Report Adding outlets to flex space (final) Inspected By: Donald Ede[ Phone: (507) 210-8233 Email: don.ede[.inspections@gmail.com Date: 9/24/2021 443 Lafayette Road N., St. Paul, MN 55155 J (651) 284-5005 I www.dli.mn.gov