HomeMy WebLinkAboutBP 2021-00089 - Electrical Permit & Inspection ReportsMDEPARTMENT OF
LABOR AND INDUSTRY
443 Lafayette Road N., St. Paul, MN 55155
(651) 284-5026, www.dli.mn.gov
Electrical Permit
�P -aoa i - 00089
Permit Number: ELE2103-10372
Permit Information as of 03/31/21
Structure Type: One -Family Home I Existing Home or Other Items Permit Status: Issued
Site County: Washington County Issued Date: 03/31/21
Site Address: 5660 Oak Cove N, Stillwater, MN 55082 Expiration Date: 03/31/22
Fees Paid: $60.00
Permit Applicant Information
Natalie Sintek Mobile: (651) 324-3246
5660 Oak Cove N, Oak Park Heighs, MN 55082 Email: nataliesintek@gmail.com
Contracted Electrical Inspector's Information
Name: Donald Ede] Phone: (507) 210-8233
Don Edel Inspections LLC Email Addres: mailto: don.edel.inspections@gmail.com
Project Information
Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmnC:xcelenergy.com
Rough -In Inspection Required: No Number of Inspections Requested: 1
Directions to Job Site: On the corner of Oakgreen Ave and Oak Park Rd
Project Description: adding outlets to flex space
Adding 4 250 -volt GFCI receptacle and outlets, replacing light fixture, adding new light fixture. This home was finished in
2021 and was built fully to code, this project will be finishing the flex space an office/ meditation space and is currently
roughed in.
A rough -in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench
backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the
cost associated with uncovering and replacing the covering material.
The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized
and the space is occupied.
Print Date: 03/31/2021
DEPARTMENT OF
LABOR AND INDUSTRY
Inspection Report
Project Name: adding outlets to flex space Permit Number: ELE2103-10372
Project location/address: 5660 Oak Cove N, Stillwater, Washington County, MN, 55082
Applicant: Natalie Sintek
Inspection Type: Partial Final
Phone: (651) 324-3246
Result: Corrections Required
Inspector Report
Adding 4 250 -volt GFCI receptacle and outlets, replacing light fixture, adding new light fixture.
This home was finished in 2021 and was built fully to code, this project will be finishing the
flex space an office/ meditation space and is currently roughed in.
(the NM cables entering the switch box require listed connectors to be installed)
(the NM cables must be strapped within 12 inches of the box)
NEC 334.30, Nonmetallic -sheathed cable shall be supported and secured by staples; cable ties
listed and identified for securement and support; or straps, hangers, or similar fittings designed
and installed so as not to damage the cable, at intervals not exceeding 4 1/2 -feet and within
12 -inches of every cable entry into enclosures such as outlet boxes, junction boxes, cabinets,
or fittings. The cable length between the cable entry and the closest cable support shall not
exceed 18 -inches. Flat cables shall not be stapled on edge.
NEC 314.17, Where raceway or cable are installed, the raceway or cable shall be secured to the
boxes.
Correct the noted deficiencies. Reinspection will be made at the time of the final inspection.
Inspected By: Donald Ede[
Phone: (507) 210-8233
Email: don.edet.inspections@gmail.com
Date: 6/29/2021
443 Lafayette Road N., St. Paul, MN 55155 ( (651) 284-5005 1 www.dii.mn.gov
DEPARTMENT OF
LABOR AND INDUSTRY
Inspection Report
Project Name: adding outlets to flex space Permit Number: ELE2103-10372
Project location/address: 5660 Oak Cove N, Stillwater, Washington County, MN, 55082
Applicant: Natalie Sintek
Phone: (651) 324-3246
Inspection Type: Final Result: Pass
Inspector Report
Adding outlets to flex space (final)
Inspected By: Donald Ede[
Phone: (507) 210-8233
Email: don.ede[.inspections@gmail.com
Date: 9/24/2021
443 Lafayette Road N., St. Paul, MN 55155 J (651) 284-5005 I www.dli.mn.gov