Loading...
HomeMy WebLinkAboutBP 2020-00329 Roof-Top Solar Panels - Electrical Permit Informatoin 1lirlDEPARTMENT OF 443 Lafayette Road N.,St. Paul, MN 55155 :14 LABOR AND INDUSTRY (651)284-5026,www.dli.mn.gov 20 2U-- Electrical Permit cc 32 1 Permit Number: ELE2011-13584 Permit Information as of 11/21/20 Structure Type:One-Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued Site County: Washington County Issued Date: 11/21/20 Site Address: 15042 63rd St N, Oak Park Heights, MN 55082 Expiration Date: 11/21/21 Fees Paid:$67.00 Job Reference: P-150152-20 Permit Applicant Information SOLCIUS LLC Phone: (844) 357-2258 SOLCIUS LLC Mobile: (844) 357-2258 1555 N FREEDOM BLVD, PROVO, UT84604 Email: solarpermits@solcius.com Property Owners Information Heather Bixby Phone: (651) 757-8618 15042 63rd St N, Stillwater, MN 55082 Email: hmbixby@yahoo.com Contracted Electrical Inspectors Information Name: Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Addres: mailto:don.edel.inspectionsPgmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough-In Inspection Required: No Number of Inspections Requested: 1 Project Description: PV System Installation of Solar PV System (24 panels, 1 inverter/s) - 7.68kW A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 11/21/2020 rrift DEPARTMENT OF LABOR AND INDUSTRY * F, .:�:. Inspection Report Project Name: PV System Permit Number: ELE2011-13584 Project location/address: 15042 63rd St N, Oak Park Heights, Washington County, MN, 55082 Applicant: SOLCIUS LLC Phone: (844) 357-2258 Owner: Heather Bixby Phone: (651) 757-8618 Inspection Type: Partial Final Result: Pass with Conditions Inspector Report 7.68 KW PV SOLAR ARRAY SOLAR EDGE (ROOF MOUNT) (A PLAQUE IS REQUIRED AT EACH POWER SOURCE) (DC PV RACEWAYS ARE REQUIRED TO BE LABELED) (THE PIERCING LINE TAPS ARE REQUIRED TO BE LISTED BY THE MANUFACTURER) NEC 690.64(6)(7) ft 705.10 (PLAQUES REQUIRED) NEC 690.31 (G)(3)8t(4) (DC RACEWAYS REQUIRED TO BE LABELED) NEC 110.2 a MINNESOTA STATUTES, SECTION326.243 (ALL ELECTRICAL EQUIPMENT TO BE LISTED) MN STATUTE326B.36, Correct the noted deficiencies. Return a signed copy of the Inspection Report to the inspector when the corrections are complete but no later than 14 days from the date of issuance unless otherwise instructed by the inspector. Inspected By: Donald Edel Email: don.edel.inspections®gmail.com Phone: (507) 210-8233 Date: 4/1/2021 443 Lafayette Road N.,St. Paul, MN 55155 (651)284-5005 I www.dli.mn.gov Misti DEPARTMENT OF x. +'0 111 LABOR AND INDUSTRY 14 ••• r I:1 Inspection Report Project Name: Revisions to 2020-00329 Permit Number: ELE2105-00848 Project location/address: 15042 63rd St N, Oak Park Heights, Washington County, MN, 55082 Applicant: SOLCIUS LLC Phone: (844) 357-2258 Owner: Heather Bixby Phone: (651) 757-8618 Inspection Type: Final Result: Pass Inspector Report 7.68 KW PV solar installation (final) Solar Edge roof mount Inspected By: Donald Edel Email: don.edel.inspections@gmail.com �.: Phone: (507) 210-8233 Date: 9/2/2021 443 Lafayette Road N., St. Paul, MN 55155 I (651) 284-5005 I www.dli.mn.gov nilDEPARTMENT OF 443 Lafayette Road N.,St. Paul, MN 55155 LABOR AND INDUSTRY (651)284-5026,www.dli.mn.gov Electrical Permit Permit Number: ELE2105-00848 Permit Information as of 05/04/21 Structure Type: One-Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued Site County: Washington County Issued Date: 05/04/21 Site Address: 15042 63rd St N, Oak Park Heights, MN 55082 Expiration Date: 05/04/22 Fees Paid: $101.00 Job Reference: P-150152-20 Permit Applicant Information SOLCIUS LLC Phone: (844) 357-2258 SOLCIUS LLC Mobile: (844) 357-2258 1555 N FREEDOM BLVD, PROVO, UT 84604 Email: solarpermits@solcius.com Property Owner's Information Heather Bixby Phone: (651) 757-8618 15042 63rd St N, Stillwater, WA 55082 Contracted Electrical Inspector's Information Name: Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Addres: mailto:don.edel.inspectionsPgmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough-In Inspection Required: No Number of Inspections Requested: 1 Project Description: Revisions to 2020-00329 Installation of Solar PV System (24 panels, 1 inverter) - 7.68kW Main Service Panel Upgrade or Replacement: 100A Bus/100A Main A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 05/04/2021