Loading...
HomeMy WebLinkAbout2008-10-21 Summit Fire Protection - Report of Inspection A.Th SUMMIT FIRE PROTECTI(?' 575 MINNEHAHA AVE.W•ST.PAUT,IAN 55103•(651)251-1880 -'k 3026 40TH A'1= • 74:11r 'V�' n '+ •+='1 5 1 •(507)280=0622 418 GREAT OAK DR.,WAITE PARK,MN 56387•(320)257-6390 760 LIBERT`; ' et! !�, + 52 •(319)665-4330 4208 ENTERPRISE CIRCLE•DULUTH,MN 55811 •(218)740-4412 '' CECr 11. SHEET 1 OF 2 Use separate sheet for each building inspection 11' t 1 2008 j REPORT OF INSPECTION MINNESOTA LICENSE NO.C0075 NUR7 INSPECTION NAME .. yh,i a/ S� - BUILDING/1.0CATTACK 4:7401-s.---- ....-- , if .' STREET 3 / , /( ' 4 ✓r7T INSPECTOR /3/Si,— CITY&STATE 0411. PA-e K., ifs#3 N DATE /O"6:21.—csg- Owner's Section(to be answered by Owner or Occupant) A. Explain any occupancy hazard changes since the previous inspection: B. Describe fire protection modifications made since last inspection: C. Describe any fires since last inspection: D. When was the system piping last checked for stoppage,corrision of foreign material? 1 E. When was the dry-piping system last checked for proper pitch? > F. Are dry v, ,est nate'pr. .n fr zing? j Signature' Title J c wP Date t"- ,0 ,R 1 Inspector's Section(All responses reference current inspection) NA=NOT APPLICABLE 1. General a.Is the building occupied? ❑No b.Are all systems in service? Yes❑No / c.Is there a minimum of 18 in.(457 mm)clearance between the top of�the,,�sttorage and the sprinkler deflectors? QSCes ❑No d.Does all electrical heat tape appear to be satisfactory? ❑Yes ❑No'ENA e.Does the hand hose o tani e I'Ithe sprinkler system(s)appear to be satisfactory? Yes ❑No❑NA 2. Control Valves(See Item 15. ,`y/, a.Are all sprinkler system control valves and all other valves in the appropriate op sed os tion?�JtiTes ❑No b.Are all control valves in the open position locked,sealed or equipped with r tamper swi ? Wes❑No 3. Tanks,Pumps,Fire Department Connections ) j / "---------- a.When was fire pump last tested for performance? 'V(1 b.Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? ❑Yes❑No VNA c.Are fire department connection�iyy��satisfactory condition,couplings free,caps in place,and check valves tight? Yes ❑No ❑NA Are they accessible and visible?�Yes❑No ❑NA 4. Wet Systems a.Are cold weather valves(O.S.&Y.)in the appr nate open or closed position? ❑Yes ❑N NA b.Have antifreeze system solutions been tested? Yes ❑No ❑NA c.What temp is antifreeze? "'4/0 d.In areas protectsg,ky wet system(s),does the buil ' g appear e properly heated in all areas,including blind attics and perimeter areas where accessible Yes ❑No❑NA 5. Dry System(See Items 11 to 13) a.Are dry valve(s)in service? ❑Yes ❑No/SNA b.Are the air pressures and priming water levels in accordance wi r- . .cturer's instructions? ❑Yes ❑No 0 NA c.Has the operation of the air or nitrogen supplies been tested? IF ;'" NA Are they in service? ❑Yes❑No ❑NA d.Were low points drained during this inspection?❑Yes ❑No Ii + ''ow many? e.Did quick-opening devices operate satisfactorily? ❑Yes • • ❑ f.Did the dry valve(s)trip properly during the trip pressure test? ❑Yes ❑No❑NA g.Did the heating equipment in the dry-pipe value room(s)operate at time of inspection? ❑Yes ❑No ❑NA 6. Special Systems(See Item 14.) a.Did the deluge or pre-action valves operate properly during testing? ❑Yes ❑ loNA b.Did the heat-responsive devices operate properly during testings ❑Yes ❑No( A c.Did supervisory devices operate during testing? ❑Yes❑No SI NA d.Did flow for kitchen hood system shut off gas or electric? ❑Yes❑No YNA 7. Alarms a.Did water motor(s)and gong(s)test satisfactorily? ❑Yes ❑No'NA b.Did electric alarm(s)test satisfactory? Yes❑Njoo ❑NA c.Did supervisory alarm service test sati factory. Yes ❑No 0 N IId.Did tamper swithces test satisfactory? Wes LI No❑NA I 8. Sprinklers a.Are all sprinklers free from corrosion,,loading or obstruction to spray discharge? ?Yes ❑No b.Are sprinklers less than 50 years old?(Older sprinklers require sample testing) '<Yes ❑No c.Are quick response and residential sprinklers less than 20 years old?(Older s i nklers require sample testing) &es ❑No d.Is stock of spare sprinklers available? es ❑No '1".5r e.Does the exterior condition of sprinkle system appear to be s tisf tory? Yes❑No f.Are sprinklers of pro temperature rating for xr` locations? es U No g.Are any spri eads ,n a recall list7lJYesNo Signature/4r .: Date: %2 C2 i 1 • 1 ,,_ ". ''"S (, SUMMIT EIS rittYrEC I#�; 57 EHAHA AVE.W•ST.PAU i 55103•(651)25 t-18 3026 40TH AV •ROCHESTER,MN 55901 •(507)280-0622 4 8GREAT OAK DR.,WAITE PARK,MN 56387•(320)257-6390 7.0 w , ,,,-....r.-.11 ' ,IA 52317•(319)665-4330 4208 ENTERPRISE CIRCLE•DULUTH,MN 55811 •(218)740-4412 i'..-- •,...........,,_ f.:.:„ ;j i f SHEET 2 OF 2-Use separate sheet for eachsystem inspection I�� �" ; I.ystem ore' "` Inspection Name and Number DEC 1 $ H,T I11 !'y'" ' hie-,..„p'*--4..„ Sv,+�! S( t 77 '1 .3 e? t>a,. tr .p • s'. eck with Pressure Switch 9. Date dry-pipe valve trip tested (control valve partially open) :l, A--= ea rip Test Table which follt s) { 10 Date dry=pipe vay,e.trip tested (control valve fully.ripen) _ (See Trip Test Table which foilowS) , 11. Date quick-opening device tested (See Trip Test able which follows) DRY VALVE TRIP TEST TABLE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE Time tos Trip Water Air Trip Point Time Water Reached Alarm Operated OPERATING Thru Test Pipe Pressure pressure Air Pressure Test Outlet Properly TEST MIN. SEC. PSt PSI PSI MIN. SEC. YES NO Without Q.O.D. With Q.O.D. 12. Date deluge or preaction valve tested I_ (See Trip Test Table which follows) TRIP TEST TABLE Operation 0 PNEUMATIC 0 ELECTRIC 0 HYDRAULIC Piping Supervised 0 YES 0 NO Detecting media supervised 0 YES 0 NO DELUGE& Does valve operate from the manual trip and/or remote control stations 0 YES 0 NO PREACTION Is there an accessible facility in each circuit for testing Method of testing-circuits VALVES 0 YES 0 NO MAKE MODEL Doessupervision ach circuit cuit operate Does each circuit Maximum time to _operate valve release operate release YES NO YES NO YES NO 13. See Control-Valve Maintenance Table. Control Valve Maintenance Table Explain 4 F Abnormal - Control Valves Number Type Open Secured Closed Signs Condition City Connection Control Valve Tank Control Valves Pump Control Valves Sectional Control Valves ,,. s 66 V � l� (,4 4/ . "C/7 w '. System Control Valves L} —�' aw Gl [ Other Control Valves 57-611+ s ,r Kitchen Control Valve ;gin" 11"►r'' 'rpt 16. Water Flow Test at Sprinkler Riser 1 Water Supply Source: City Tank Pump Date Test Pipe Size of Static Residual Differential Location Test Pipe Pressure (Flow) Last Water Flow Test t;;f)'-eft/ >'r7e--)re ---J /cc) '7ff.�� ptQ i This Water Flow Test /p' 1'C• kk r - f it /de) 77 `/' 14. Explain any"No"answers and comments: Signature: Date: 21 ,d 8-- ,.-