HomeMy WebLinkAbout2007-08-30 Summit Fire Protection - Report of Inspection 4 AN _ SUMMA FIRE PROTECTION - ` , � 575 MJ!NEHAHA AVE.W•ST.'PAUL,MN 55103•(651)-LD-141880 t l-`" --°o—» 1 3026 40TH AVE.NW•ROCHESTER,MN 55901 •(507)280-0622 ' 418 GREAT OAK DR.,WA1'I'h PARK,MN 56387•(320)257-6390 k OCT I , Luu' 760 LIBERTY WAY,NORTH LIBERTY,IA 52317•(319)665-4330 /, SHEET 1 OF 2-Use separate sheet for each building inspection f REPORT OF INSPECTION MI SOTA LICENSE NO.C0075 JOB NUMBER 1 —°"' I CTION NAME ii I' BUILDING/LOCATION SAin/4 STREET` 4315 sr elli/V .. ikio. INSPECTOR +'�;, ,+'l A CITY&STATE <� "el( /Yic,c , DATE � -0 7 Owner's Section(to be answered by Owner or Occupant) ,,4,f 11 A. Explain any occupancy hazard changes since the previous inspection: Vole B. Describe fire protection modifications made since last inspection: moy,4 C. Describe any fires since last inspection: D. When was the system piping last checked oppage,corrision of foreign material? 0.,e li,it A E. When was the cir 'piping syste ecked for proper.i h?Aar F: Are dry.valses adequately.pr6 'cterom freezing? A a .--- Signature: .,,..,.75,,,,‹......„ / r_;- Title d'') r._ s ...,. ) e ». &Dale ' '""i '- /...-4,a„ Inspector's Section(All responses reference current inspection) NA=NOT APP CABLE 1. General 1 k a.Is the building occupied?ld s ❑No l' b.Are all systems in service? Yes❑No c.Is there a minimum of 18 in.(457 mm)clearance between the top of her storage and the sprinkler deflectors?,, Yes ❑No d.Does all electrical heat tape appear to be satisfactory? UYes ❑NogNA e.Does the hand hose or standpipe on the sprinkler system(s)appear to be satisfactoryes ❑No❑NA 2. Control Valves(See Item 15.) a.Are all sprinkler system control valves and all other valves in the appropriate open or closed position? es ❑No b.Are all control valves in the open position locked,sealed or equipped with a tamper switch? ❑Ye No 3. Tanks,Pumps,Fire Department Connections f,� a.When was fire pump last tested for performance? /�+T4' b.Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? UYes❑No 'NA c.Are fire department connections ip satisfactory condition,couplings free,caps in place,and check valves tight?"Yes ❑No ❑NA ' Are they accessible and visible?4Yes❑No ❑NA 4. Wet Systems a.Are cold weather valves(O.S.&Y.)in the appropriate open or closedoposition? UYes ❑No_ 'NA b.Have antifreeze system solutio en tested? UYes ❑Nod$NA c.What temp is antifreeze? d.In areas protectec y wet system(s),does the building appear to be properly heated in all areas,including blind attics and perimeter,areas where accessible ,,?1Yes ❑No❑NA 5. Dry System(Sce Items 11 to 13) I a.Are dry valve(s)in service? UYes ❑No ANA b.Are the air pressures and priming water levels in accordance with the manufacver's instructions? UYes ❑No f!'IeNA c.Has the operation of the air or nitrogen supplies been tested? UYes❑No !U NA AreAim service? UYes❑No/1'J` NA d.Were low points drained during this inspection?UYes ❑No❑4lA Ijow many? 55�i' e.Did quick-opening devices operate satisfactorily? UYes ❑No.. NA \-, f. f.Did the dry valve(s)trip properly during the trip pressure test? UYes ❑NgtJ NA g.Did the heating equipment in the dry-pipe value room(s)operate at time of inspection? ❑1'es ❑NogNA 6. Special Systems(See Item 14.) a.Did the deluge or pre-action valves operate properly during testing? O'Yes ❑No iNA b.Did the heat-responsive devices operate properly during testing? UYes ❑No.E4NA c.Did supervisory devices operate during testing? UYes❑No 4 NA d.Did flow for kitchen hood system shut off gas or electric? UYes❑No.dNA 7. Alarms a. id water motor(s)and gong(s)test satin ctorily? UYes 0 No %NA 4 C>Ca4+L+ 14.4,14115- b. 4b.Did electric alarm(s)test satisfactory' Yes❑No ❑NA c.Did supervisory alarm service test satisfactory? UYes ❑No#'NA d.Did tamper swithces test satisfactory? ❑Yes4 No 0 NA 8. Sprinlders �.�/� a.Are all sprinklers free from corrosion,loading or obstruction to spray discharge? UYes.rFi.�J No b.Are sprinklers less than 50 years old?(Older sprinklers require sample testing)4Yes ❑No c.Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing) UYes ❑No { d.Is stock of spare sprinklers available? es ❑No e.Does the exterior condition of sprinkler system appear to be satisf ctory? ❑Yes+iNo f.Are sprinklers of proper temperature rating for their locations?,A'Yes 0 No g.Are any sprinkler heads on a recall list?❑Yeso Signature: r Y )ied.r.- ;,:'!"°..F Date: P "�36 -"-=,7 SUMMIT FIRE PROTECTION 575 MINNEHAHAAVE.W•ST.PAUL,MN 55103•(651)251-1880 3026 40TH AVE.NW•ROCHESTER,MN 55901 •(507)280-0622 418 GREAT OAK DR.,WAITE PARK,MN 56387•(320)257-6390 760 LIBERTY WAY,NORTH LIBERTY,IA 52317•(319)665-4330 4208 ENTERPRISE CIRCLE•DULUTH,MN 55811•(218)740-4412 SHEET 2 OP 2-Use separate sheet for eachsystem inspection Type y dvP7rre ,,� r� of System Inspection Name and Number j"� ��+!' rf a 70;a0 How Many? lf J '"* J/4e What Size? T 4 424 s '„,h or Alarm Check with Pressure Switch 9. Date dry-pipe valve trip tested(control valve partially open) (See Trip Test Table which follows) 10. Date dry-pipe valve trip tested(control valve fully open) ___ (See Trip Test Table which follows) 11. Date quick-opening device tested (See Trip Test Ta le which follows) DRY VALVE TRIP TEST TABLE a.O.D. MAKE MOD SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE Time to Trip ater Air Trip Point lime Water Reached Afar;Operated OPERATMIG Thru Test Pipe P pressure Air Pressure Test Outlet Properly MIN. SEC. PSI PSI PSI MIN. SEC. YES NO TEST Without Q.O.D. With Q.O.D. 12. Date deluge or preaction valve tested7A (See Trip Test Table which follows) if TRIP TEST TABLE Operation 0 . E, v 0 ELECTRIC 0 HYDRAULIC . Piping Supervised 0 YES 0 NO Detecting media supervised 0 YES 0 NO DELUGE& Does valve operate from the manual trip anclor remote control stations ❑ YES 0 NO PREACTION Is there an accessible facility in each circuit for testing Method of testing-circuits VALVES I]YES Cl NO Does each circuit operate Does each circuit Maximum time to MAKE MODEL supervision loss alarm operate valve release operate release YES NO YES NO YES ) NO 13. See Control Valve Maintenance Table. Control Valve Maintenance Table Explain Abnormal Control Valves Number Type Open Secured Closed Signs Condition City Connection Control Valve Tank Control Valves •remgt Control Valves 4 FL 12 - L * 158 V y tr A.Xs iv ,j/ °` +eestIMISI Control Valves I.-le G►U �t, , System Control Valves f..a'�■ 616 1? ft .0 A eti,ze /i N /J ` t" -swap Control Valves ? I/f• 0541' •f ,✓fi /Uo ,( o Kitchen Control Valve 16. Water Flow Test at Sprinkler Riser Water Supply Source: City Tank Pump Date est Pipe Size of Static Residual Differential Location Test Pipe Pressure (Flow) Last Water Flow Test /f(/ Pressure / O ' This Water Flow Test 4 7 r♦ 1/ 70 6 'I tit 14 Explain my"No"answers and comment:, -pre, S ,comments:, '`/ lr ' /'_ ' + ►tl►! '' ,, .:err! 7.11 r l/1,�. T ii veil`''<L / � Signature: yr'-• : ...,4, `„<. .. Date: --30— .''