Loading...
HomeMy WebLinkAboutBP 2021-00127 Storage Shed - Electrical Permit & Inspection Report r DEPARTMENT OF 443 Lafayette Road N.,St. Paul, MN 55155 LABOR AND INDUSTRY (651) 284-5026,www.dli.mn.gov Electrical Permit Bext l _ o o l art Permit Number: ELE2110-06489 Permit Information as of 10/15/21 Structure Type:One-Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued Site County: Washington County Issued Date: 10/15/21 Site Address: 5565 Peller Ave N, Oak Park Heights, MN 55082 Expiration Date: 10/15/22 Fees Paid: $71.00 Permit Applicant Information ALL TECH ELECTRIC LLC Phone: (651) 303-8882 ALL TECH ELECTRIC LLC Mobile: (651) 303-8882 11240 STILLWATER BLVD N, LAKE ELMO, MN55042 Email: brandon@alltechmn.com Property Owner's Information Tom Thiets Phone: (651) 788-5112 5655 Peller Ave N, Bayport, MN 55082 Mobile: (651) 788-5112 Contracted Electrical Inspector's Information Name: Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Address: mailto: don.edel.inspections@gmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bctmn@xcelenergy.com Rough-In Inspection Required: Yes Number of Inspections Requested: 2 Directions to Job Site: Why 36 east to Osgood ave south to 59th street east. 59th street becomes 60th street follow to Peller Ave N take a right the house is on the left side of the street Project Description: Install emergency generator transfer switch and feeder from generator, plus underground ckt to shed Install 200 amp emergency generator transfer switch for service, plus 60 amp feeder from generator. Install 20 amp 120 volt underground branch circuit to shed. A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 10/15/2021 DEPARTMENT OF , • ,r0 • LABOR AND INDUSTRY - ; ti Inspection Report Project Name: Install emergency generator transfer Permit Number: ELE2110-06489 switch and feeder from generator, plus underground ckt to shed Project location/address: 5565 Peller Ave N, Oak Park Heights, Washington County, MN, 55082 Applicant: ALL TECH ELECTRIC LLC Phone: (651) 303-8882 Owner: Tom Thiets Phone: (651) 788-5112 Inspection Type: Final Result: Pass with Conditions Inspector Report Install 200 amp emergency generator transfer switch for service, plus 60 amp feeder from generator. Install 20 amp 120 volt underground branch circuit to shed. (final) (the main breaker in the shed panel needs to have a retaining device to lock the breaker in place) (2-ground rods are required at the garage service) NEC 250.53, Unless a rod, pipe and plate electrode has a resistance to ground of 25 ohms or less, it shall be supplemented with another acceptable electrode other than an underground water pipe. NEC 408.36, Back-fed overcurrent devices shall be secured by an additional approved fastener that requires a tool for removal. MN STATUTE326B.36, Correct the noted deficiencies. Return a signed copy of the Inspection Report to the inspector when the corrections are complete but no later than 14 days from the date of issuance unless otherwise instructed by the inspector. Inspected By: Donald Edel Email: don.edel.inspections@gmail.com Phone: (507) 210-8233 Date: 12/7/2021 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-50051 www.dli.mn.gov