HomeMy WebLinkAbout2022-05-17 Stanted Review of Plans Submitted 5-10-2022, revised 5-16-2022Stantec Consulting Services Inc. 733 Marquette Avenue Suite 1000, Minneapolis MN 55402-2309 May 17, 2022 File: 193800151-137 Attention: Mr. Eric Johnson City of Oak Park Heights 14168 Oak Park Blvd. Oak Park Height, MN 55082 Reference: Park Dental – Review of plans submitted 5-10-2022, revised 5-16-2022 Dear Eric: We have reviewed the re-submitted plans dated 5-10-2022, revised 5-16-2022, for the proposed Park Dental project. All previous comments have been addressed and we have no further comments. The General Comments from previous letters still apply. If you have any questions or require further information, please do not hesitate to contact me. Regards, Stantec Consulting Services Inc. Lee M. Mann, PE MN, WI, CA Principal Phone: 612-712-2085 Lee.Mann@stantec.com c.file Julie Hultman, Building Official Andrew Kegley, Director of Public Works Scott Richards, City Planner Kevin Sandstrom, City Attorney WWWWWWWWWWWWWREMOVE CURB & GUTTER REMOVE CONCRETE DRIVEWAY APRON REMOVE MONUMENT SIGN & PLANTING BED REMOVE MONUMENT SIGN REMOVE BUILDING REMOVE BUILDING EXISTING PARK DENTAL BUILDING TO REMAIN UNTIL OPERATION IS MOVED TO NEW BUILDING. REMOVE CONCRETE REMOVE CONCRETE REMOVE BITUMINOUS PAVEMENT REMOVE & REPLACE BITUMINOUS TRAIL REMOVE & REPLACE BITUMINOUS STREET FOR CURB & GUTTER CONSTRUCTION REMOVE & REPLACE BITUMINOUS STREET FOR CURB & GUTTER CONSTRUCTION REMOVE CURB STOP & WATER SERVICE TO MAIN REMOVE CURB STOP & WATER SERVICE TO MAIN REMOVE SANITARY SEWER SERVICE TO PROPERTY LINE. PROPOSED BUILDING TO BE SERVED WITH THIS LINE. REMOVE WATER SERVICE REMOVE SANITARY & WATER SERVICES REMOVE SANITARY & WATER SERVICES AFTER OPERATION IS MOVED TO NEW BUILDING REMOVE & REPLACE BITUMINOUS TRAIL REMOVE CABLE TV UTILITY REMOVE ROOF DRAIN AFTER OPERATION IS MOVED TO NEW BUILDING CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 2:37 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C1-2 Demo PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 N SCALE IN FEET 0 20 40 DEMOLITION PLAN C1-2 NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY WESTWOOD PROFESSIONAL SERVICES, DATED 06/22/18. REMOVE EXISTING CURB & GUTTER, RETAINING WALLS, FENCE, ETC. REMOVE EXISTING MANHOLES, POWER POLES, LIGHT POLES, BOLLARDS, PARKING METERS, SIGNS, ETC. REMOVE EXISTING CONCRETE PAVING, SIDEWALKS, ETC. REMOVE EXISTING TREES - SEE SHEET L0-1 REMOVE EXISTING UTILITIES REMOVE EXISTING BITUMINOUS PAVING DEMOLITION LEGEND: 1.CONTRACTOR SHALL REMOVE AND/OR RELOCATE EXISTING PRIVATE UTILITIES AS NECESSARY. CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES. 2.CONTRACTOR SHALL PROTECT SURFACE AND SUBSURFACE FEATURES NOT NOTED FOR REMOVAL. 3. CONTRACTOR TO CLEAR AND GRUB EXISTING VEGETATION WITHIN CONSTRUCTION LIMITS, STRIP TOP SOIL, AND STOCKPILE ON-SITE. REFER TO GRADING PLAN AND SWPPP FOR SEDIMENT AND EROSION CONTROL REQUIREMENTS. 4.CLEAR AND GRUB AND REMOVE ALL TREES, VEGETATION AND SITE DEBRIS PRIOR TO GRADING. ALL REMOVED MATERIAL SHALL BE HAULED FROM THE SITE DAILY. ALL CLEARING AND GRUBBING AND REMOVALS SHALL BE PERFORMED PER THE CONTRACT SPECIFICATIONS. EROSION CONTROL MEASURES SHALL BE IMMEDIATELY ESTABLISHED UPON REMOVAL. SEE THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP). 5.CONTRACTOR SHALL REMOVE ALL SITE SURFACE FEATURES WITHIN REMOVAL LIMITS UNLESS OTHERWISE NOTED. SITE DEMOLITION NOTES 1.THE CONTRACTOR SHALL CLEAR & GRUB AS SHOWN ON PLANS. THIS INCLUDES THE REMOVAL OF TREES, BRUSH, STUMPS, ROOTS AND OTHER PLANT LIFE AS NOTED. ALL REMOVALS SHALL BE DISPOSED OF OFF-SITE IN A MANNER MEETING ALL APPLICABLE REGULATIONS. 2.BITUMINOUS PAVEMENT REMOVALS ARE TO BE MADE TO A VERTICAL SAW CUT OR TO A NEAT MILLED EDGE. 3.CONCRETE PAVEMENT, SIDEWALK, CURB & GUTTER AND OTHER POURED CONCRETE ITEMS ARE TO BE REMOVED TO AN EXISTING EXPANSION OR CONTRACTION JOINT. SAW CUT AS NECESSARY FOR A NEAT EDGE OF REMOVAL. 4.ALL REMOVAL ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR UNLESS SPECIFIED OTHERWISE AND SHALL BE DISPOSED OF OFF-SITE IN A MANNER MEETING ALL APPLICABLE REGULATIONS. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF ALL SIGNS, MAILBOXES, ETC. 6.ANY DAMAGE TO ITEMS NOT NOTED TO BE REMOVED SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REPAIRED OR REPLACED TO ORIGINAL CONDITION WITH NO ADDITIONAL COMPENSATION. DEMOLITION SPECIFICATIONS TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. REMOVE EXISTING BUILDING NO PARKING NO PARKING PROPOSED BUILDING FFE=938.00 60TH STREET N. FUTURE ADDITION FFE=938.00 FILTRATION BASIN 1 NWL=DRY BTM=931.50 HWL=934.16 MEDIA INV=929.50 6" DT INV=929.50 FILTRATION BASIN 2 NWL=DRY BTM=934.30 HWL=935.99 MEDIA INV=932.30 6" DT INV=932.30 18.0' 9.0'9.0'9.0'9.0'9.0' 9.0' TYP. 9.0' TYP 9.0' TYP. 11 6 17 10 10 24.0' 22.0' 22.0'28.0'28.3' 28.3' 5.0' CONCRETE SIDEWALK TYP-SEE DETAIL ADA PARKING SIGN ON BOLLARDS (3) TYP-SEE DETAIL TYP ADA PARKING SEE DETAIL B612 CURB & GUTTER TYP-SEE DETAIL 16.6' TRASH ENCLOSURE SEE ARCHITECTURAL PLAN MATCH EXISTING CURB AND GUTTER MATCH EXISTING CURB AND GUTTER CONCRETE STOOP SEE ARCHITECTURAL & STRUCTURAL PLANS CONCRETE STOOP SEE ARCHITECTURAL & STRUCTURAL PLANS FLAT CURB TYP-SEE DETAIL PROPERTY LINE HEAVY DUTY BITUMINOUS PAVEMENT TYP-SEE DETAIL LIGHT DUTY BITUMINOUS PAVEMENT TYP-SEE DETAIL CONCRETE PAVEMENT TYP-SEE DETAIL 3' TRANSITION TO FLAT CURB 18' TRANSITION TO FLAT CURB 20.0' 20.0' 10.0' 59.6' RIGHT OF WAY LINE 40.0' 10.0' 41.9' MATCH EXISTING BIT. TRAIL WIDTH & SECTION CONCRETE DRIVEWAY APRON 42.5'R 1.0'R 5.0'R 25.0'R 30.0'R BIKE RACK TYP-SEE DETAIL 10' TRANSITION TO FLAT CURB 10' TRANSITION TO FLAT CURB CONCRETE PEDESTRIAN RAMP STAIRS (SEE GRADING PLAN) 18.0' 18.0' 1.0'R 1.0'R 1.0'R 42.5'R 42.5'R 42.5'R 42.5'R 1.0'R 42.5'R 42.5'R 42.5'R 1.0'R 1.0'R 1.0'R MONUMENT SIGN SEE ARCHITECTURAL & STRUCTURAL PLANS TRANSFORMER B612 CURB & GUTTER TYP-SEE DETAIL EXISTING PARK DENTAL BUILDING PER SURVEY BY OTHERS 3.0'R 3.0'R 30.0'R 20.0' FLAT CURB TYP-SEE DETAIL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:26 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C2-1 Site PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 N SCALE IN FEET 0 20 40 NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY WESTWOOD PROFESSIONAL SERVICES, DATED 06/22/18. TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. CURRENT ZONING:B-4, LIMITED BUSINESS DISTRICT PROPOSED ZONING:B-4, LIMITED BUSINESS DISTRICT PROPERTY AREA:1.493 AC DISTURBED AREA:1.493 AC EXISTING IMPERVIOUS AREA:1.228 AC (82.3%) EXISTING PERVIOUS AREA:0.265 AC (17.7%) EXISTING IMPERVIOUS AREA TO REMAIN:0.175 AC PROPOSED IMPERVIOUS AREA:0.849 AC TOTAL SITE IMPERVIOUS AREA:1.024 AC (68.6%) PROPOSED PERVIOUS AREA:0.469 AC (31.4%) STANDARD PARKING STALLS:51 ADA PARKING STALLS:3 TOTAL PARKING STALLS:54 SITE DATA 1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND STATE/LOCAL JURISDICTION REQUIREMENTS. 2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND LOCAL/STATE REQUIREMENTS. 3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. 5.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. 6.REFER TO ARCHITECTURAL SITE PLAN FOR BUILDING SETBACKS. 1.MINNESOTA STATE STATUTE REQUIRES NOTIFICATION PER "GOPHER STATE ONE CALL" PRIOR TO COMMENCING ANY GRADING, EXCAVATION OR UNDERGROUND WORK. 2.THE CONTRACTOR SHALL FIELD VERIFY LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM THE PLANS. 3.THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASE OF THIS PROJECT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGES TO ADJACENT PROPERTIES OCCURRING DURING THE CONSTRUCTION PHASE OF THIS PROJECT. 4.THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TRAFFIC CONTROL DEVICES SUCH AS BARRICADES, WARNING SIGNS, DIRECTIONAL SIGNS, FLAGMEN AND LIGHTS TO CONTROL THE MOVEMENT OF TRAFFIC WHERE NECESSARY. PLACEMENT OF THESE DEVICES SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE APPROPRIATE MINNESOTA DEPARTMENT OF TRANSPORTATION STANDARDS. 5.IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 6.THE DUTY OF THE ENGINEER OR THE DEVELOPER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTORS SAFETY MEASURES IN, OR NEAR THE CONSTRUCTION SITE. 7.BEFORE BEGINNING CONSTRUCTION THE CONTRACTOR SHALL INSTALL EROSION AND SEDIMENTATION CONTROL MEASURES IN ACCORDANCE WITH NPDES PERMIT REQUIREMENTS, BEST MANAGEMENT PRACTICES, STATE AND LOCAL REQUIREMENTS AND THE DETAILS SHOWN ON THE DETAIL SHEET(S) OF THE PROJECT PLANS. 8.ALL CONSTRUCTION PERMITS, APPLICATIONS AND FEES ARE THE RESPONSIBILITY OF THE CONTRACTOR. 9.ALL ENTRANCES AND CONNECTIONS TO CITY STREETS SHALL BE CONSTRUCTED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND NOTIFICATIONS AS REQUIRED. 10.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. 11.ADJUST ALL EXISTING STRUCTURES, BOTH PUBLIC AND PRIVATE TO THE PROPOSED GRADES WHERE DISTURBED AND COMPLY WITH ALL REQUIREMENTS OF THE UTILITY OWNERS. STRUCTURES BEING RESET TO PAVED AREAS MUST MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING. 13.SUBGRADE PREPARATION SHALL BE PERFORMED IN ACCORDANCE WITH MNDOT 2112. THE TOP 3 FEET SHALL BE COMPACTED TO 100% OF THE STANDARD PROCTOR DENSITY. 14.AGGREGATE BASE SHALL BE MNDOT 2211 CLASS 5. COMPACTION SHALL BE BY THE QUALITY COMPACTION METHOD. 15.PLANT MIXED BITUMINOUS PAVEMENT SHALL BE CONSTRUCTED IN ACCORDANCE WITH MNDOT 2360 WITH MIX DESIGN AS SHOWN ON THE DETAILS. COMPACTION SHALL BE BY THE ORDINARY COMPACTION METHOD. 16.CONCRETE CURB & GUTTER SHALL BE PERFORMED IN ACCORDANCE WITH MNDOT 2531. CURING SHALL BE BY THE MEMBRANE CURING METHOD. EXPANSION JOINTS EVERY 200 FEET AT ALL FIXED OBJECTS. CONTRACTIONS JOINTS EVERY 10 FEET. 17.CONCRETE WALK SHALL BE PERFORMED IN ACCORDANCE WITH MNDOT 2521. CURING SHALL BE BY THE MEMBRANE CURING METHOD. EXPANSION JOINTS AT ALL FIVES OBJECTS. CONTRACTION JLINTS EVERY 5 FEET. 18.A CITY RIGHT-OF-WAY PERMIT IS REQUIRED TO WORKING WITHIN RIGHT OF WAY. 19.STREET PATCHING ON PUBLIC STREETS AT A MINIMUM SHALL MATCH EXISTING PAVEMENT SECTION. THE SECTION TO BE USED WILL BE CONFIRMED AT THE TIME OF CONSTRUCTION; WEAR COURSE TO BE A MINIMUM OF 11 2" INCHES, UTILIZING C TYPE OIL. THE PATCH JOINTS SHALL BE BUTT JOINTS. DENOTES CONCRETE PAVEMENT DENOTES HEAVY DUTY BITUMINOUS PAVEMENT DENOTES LIGHT DUTY BITUMINOUS PAVEMENT SITE NOTES GENERAL NOTES PAVEMENT LEGEND DENOTES CONCRETE SIDEWALK PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 DENOTES BITUMINOUS TRAIL SITE PLAN C2-1 NO PARKING NO PARKING PROPOSED BUILDING FFE=938.00 60TH STREET N. FUTURE ADDITION FFE=938.00 936. 0 0 936. 5 0 93 6 . 0 0 936.89 HP 937.70 937.70 93 7 . 5 0 937. 5 0 937.70937.70937. 5 0 93 7 . 5 0 937.70 936.48936. 9 6 HP 937.70937.44937. 1 0 937. 2 0 93 6 . 5 0 937.00 937. 1 0 937. 1 0 93 6 . 5 0 937. 1 2 937.21 93 7 . 3 0 937. 3 0 937. 6 5 937. 8 0 937. 3 0 937. 3 0 936.60 936.55 MATC H E XI S TI N G 934. 4 4 MATC H E XI S TI N G 933. 8 8 934. 2 1 EO F 93 4 . 7 5 93 7 . 8 0 93 7 . 8 0 93 7 . 8 0 93 7 . 8 0 93 7 . 8 0 937. 8 0 8 8 8 8 8 8888888888935 932 933934 936 935936937 93 7 937 937 9 3 7 935 936937938 EOF 935.80 FILTRATION BASIN 1 NWL=DRY BTM=931.50 HWL=934.16 MEDIA INV=929.50 6" DT INV=929.50 FILTRATION BASIN 2 NWL=DRY BTM=934.30 HWL=935.99 MEDIA INV=932.30 6" DT INV=932.302.2%2.2%1. 8%1.5% 1.1%1.5% 2. 6%2.4% 0.6%0.7%0.9%2.0%2.2%1.5%4493 7 . 5 0 93 7 . 5 0 93 7 . 5 0 937. 7 4 93 7 . 8 0 x x x x xx937.5 937.85 937.85 x 938.0 937.90 x 937.7 937.4 937.8 14.0% 25.3% 11.0% 12.9 % 9.2% 30.8% 20.1% 20.6% 27.4% 1 . 9% 3 .8%16.5%16.7%11.3% 3.3% x 937.67 SWALE 1.2% 937.70 937.39 935.51936.69 936.95937.46 935.34 935.95 937.98 3.8%10.1% 10.0% x 937.5 SWALE 1.5% x 937.0 x 936.3 x 937.60 x 937.27 x 937.36 x 937.80 x x 938.00 937.80 SWALE 1.0% 10' CURB TRANSITION FLAT CURB 10' CURB TRANSITION18' CURB TRANSITION 3' CURB TRANSITION FLAT CURB B612 CURB B612 CURB B612 CURB 936.10 93 6 . 7 7 93 6 . 7 7 93 6 . 7 7 93 6 . 7 7 1.2% 9 3 7 . 2 7 x937.80 x936.05x937.80 x937.80 x937.80 xx 936.05937.808 2.0% MAX. SLOPE IN ANY DIRECTION 935 934.3 EXISTING PARK DENTAL BUILDING PER SURVEY BY OTHERS CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:26 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C3-1 Grading And Drainage PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 N SCALE IN FEET 0 20 40 NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY WESTWOOD PROFESSIONAL SERVICES, DATED 06/22/18. TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 1.SEE STORMWATER POLLUTION PREVENTION PLAN FOR SOIL STABILIZATION INFORMATION. 2.EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE ESTABLISHED AROUND THE ENTIRE SITE PERIMETER AND IN ACCORDANCE WITH NPDES PERMIT REQUIREMENTS, BEST MANAGEMENT PRACTICES, CITY REQUIREMENTS AND THE DETAILS SHOWN ON THE CIVIL DETAILS SHEETS OF THESE PLANS. 3.ALL CURB SPOT ELEVATIONS ARE TO GUTTER LINE-UNLESS NOTED OTHERWISE. 1.SPOT ELEVATIONS REPRESENT FINISHED SURFACE GRADES, GUTTER/FLOW LINE, FACE OF BUILDING, OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2.CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH BASINS IN GUTTERS SHALL BE SUMPED 0.16 FEET. RIM ELEVATIONS SHOWN ON PLANS DO NOT REFLECT SUMPED ELEVATIONS. 3.ALL DISTURBED UNPAVED AREAS ARE TO RECEIVE MINIMUM OF 4 INCHES OF PREMIUM TOP SOIL AND SEED/MULCH OR SOD. THESE AREAS SHALL BE WATERED/MAINTAINED BY THE CONTRACTOR UNTIL VEGETATION IS ESTABLISHED. VERIFY WITH LANDSCAPE PLAN. 4.REFER TO THE REPORT OF GEOTECHNICAL EXPLORATION AND REVIEW (REPORT P-0004506), DATED 8/3/2021 AS PREPARED BY AMERICAN ENGINEERING TESTING INC. FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS. 5.STREETS MUST BE CLEANED AND SWEPT WHENEVER TRACKING OF SEDIMENTS OCCURS AND BEFORE SITES ARE LEFT IDLE FOR WEEKENDS AND HOLIDAYS, OR AS DIRECTED BY CITY. A REGULAR SWEEPING SCHEDULE MUST BE ESTABLISHED. 6.DUST MUST BE ADEQUATELY CONTROLLED. 7.SEE SWPPP FOR ADDITIONAL EROSION CONTROL NOTES AND REQUIREMENTS. 8.SEE UTILITY PLAN FOR WATER, STORM AND SANITARY SEWER INFORMATION. 9.SEE SITE PLAN FOR CURB AND BITUMINOUS TAPER LOCATIONS. 10.A STREET SWEEPER MUST BE AVAILABLE WITHIN 3 HOURS UPON NOTICE FROM THE CITY THAT THE STREETS NEED TO BE SWEPT. 11.THE CONTRACTOR ALONG WITH THE OWNER SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM GOVERNING AUTHORITIES, INCLUDING ANY CITY PERMITS AND THE NPDES PERMIT FROM THE MPCA. 12.INSTALL EROSION CONTROL AND TREE PROTECTION MEASURES BEFORE BEGINNING SITE GRADING ACTIVITIES. SOME EROSION CONTROLS SUCH AS BALE CHECKS AND TEMPORARY SILT PONDS MAY BE INSTALLED AS GRADING OCCURS IN SPECIFIC AREAS. MAINTAIN EROSION CONTROLS THROUGHOUT THE GRADING PROCESS AND REMOVE WHEN TURF HAS BEEN ESTABLISHED. 13.THE CONTRACTOR SHALL ADHERE TO ALL REQUIREMENTS OF THE MPCA NPDES PERMIT. THE AREA TO BE DISTURBED SHALL BE MINIMIZED AND TURF SHALL BE ESTABLISHED WITHIN THE TIME REQUIRED. 14.GRADES SHOWN ARE FINISHED GRADES. 15.FINAL GRADING TOLERANCES ARE +/-0.1 FEET TO FINISH GRADES. 16.UNDER PAVEMENTS COMPACT THE UPPER 3 FEET OF SUBGRADE TO 100% STANDARD PROCTOR DENSITY AT OPTIMUM MOISTURE CONTENT AND 95% STANDARD PROCTOR DENSITY BLOW THE UPPER 3 FEET OF SUBGRADE. OUTSIDE PAVEMENT AREAS COMPACT EMBANKMENTS TO 95% STANDARD PROCTOR DENSITY. 17. WORKING HOURS ARE 7:00 AM - 10:00 PM, MONDAY - SATURDAY. A 48 HOUR NOTICED IS REQUIRED FOR SATURDAY WORK. 18.THE CONTRACTOR MUST HAVE A CITY LICENSE. 19.A CITY RIGHT-OF-WAY PERMIT IS REQUIRED PRIOR TO WORKING WITHIN CITY ROW. 20.FILTRATION BASINS SHALL BE TESTED TO CONFIRM THAT BASINS WORK AS DESIGNED PRIOR TO THE RELEASE OF ANY REMAINING FEE OR SECURITY FROM THE MIDDLE ST. CROIX WATERSHED MANAGEMENT ORGANIZATION (MSCWMO). 21.CONTRACTOR TO PROVIDE RECORD PLANS OF THE FILTRATION BASINS. THIS MUST INCLUDE AREA OF BASIN AND DEPTH OF BASIN TO CONFIRM VOLUME. CONTRACTOR SHALL ALSO PROVIDE FILTRATION TESTING TO CONFIRM THAT THE DESIGN FILTRATION RATE OF 1.63 TO 8.0 IN/HR. HAS BEEN MET. 22.EXISTING TOPOGRAPHY PROVIDED BY OTHERS. GRADING & DRAINAGE NOTES GRADING, DRAINAGE & EROSION CONTROL SPECIFICATIONS GRADING PLAN C3-1 NO PARKING NO PARKING PROPOSED BUILDING FFE=938.00 60TH STREET N. FUTURE ADDITION FFE=938.00 8 8 8 8 8 8888888888935 932 933934 936 935936937 93 7 937 937 9 3 7 935 936937938 FILTRATION BASIN 1 NWL=DRY BTM=931.50 HWL=934.16 MEDIA INV=929.50 6" DT INV=929.50 FILTRATION BASIN 2 NWL=DRY BTM=934.30 HWL=935.99 MEDIA INV=932.30 6" DT INV=932.30448SILT FENCE TYP-SEE DETAIL INLET PROTECTION TYP-SEE DETAIL INLET PROTECTION TYP-SEE DETAIL INLET PROTECTION TYP-SEE DETAIL ROCK CONSTRUCTION ENTRANCE TYP-SEE DETAIL EROSION CONTROL WOODFIBER BLANKET TYP-SEE DETAIL POST CONSTRUCTION SILT FENCE TYP-SEE DETAIL POST CONSTRUCTION SILT FENCE TYP-SEE DETAIL EROSION CONTROL WOODFIBER BLANKET TYP-SEE DETAIL EXISTING PARK DENTAL BUILDING PER SURVEY BY OTHERS CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:27 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C3-2 SWPPP PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 N SCALE IN FEET 0 20 40 SWPPP PLAN C3-2 NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY WESTWOOD PROFESSIONAL SERVICES, DATED 06/22/18. TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 SEE SHEET C3-3 FOR SWPPP NOTES AND C8-1&2 FOR SWPPP DETAILS. GENERAL NOTES SWPPP LEGEND SILT FENCE INLET PROTECTION EXISTING DRAINAGE PATTERN PROPOSED DRAINAGE PATTERN ROCK CONSTRUCTION ENTRANCE WOODFIBER BLANKET BIOROLL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:27 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C3-3 SWPPP DetailOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 SWPPP NOTES C3-3 TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 1.THE NATURE OF THIS PROJECT WILL CONSIST OF CONSTRUCTING A SINGLE-STORY OFFICE BUILDING & THE ASSOCIATED PARKING, UTILITIES, & STORM WATER TREATMENT AREAS. 2.THE INTENDED SEQUENCING OF MAJOR CONSTRUCTION ACTIVITIES ARE AS FOLLOWS: 1.INSTALL VEHICLE TRACKING BMP 2.INSTALL SILT FENCE AROUND SITE 3.INSTALL PROTECTIVE FENCE AROUND FILTRATON AREAS 4.CLEAR AND GRUB SITE 5.STRIP AND STOCKPILE TOPSOIL 6.REMOVE PAVEMENTS AND UTILITIES 7.CONSTRUCT STORMWATER MANAGEMENT BASINS 8.INSTALL SILT FENCE AROUND BASINS 9.ROUGH GRADE SITE 10.IMPORT CLEAN FILL FOR REPLACEMENT AND BALANCE 11.INSTALL UTILITIES 12.INSTALL INLET PROTECTION ON STORM CATCH BASINS. 13.INSTALL BUILDING FOUNDATIONS 14.INSTALL CURB AND GUTTER 15.INSTALL PAVEMENTS AND WALKS 16.FINAL GRADE SITE 17.REMOVE ACCUMULATED SEDIMENT FROM BASINS 18.SEED AND MULCH 19.WHEN ALL CONSTRUCTION ACTIVITY IS COMPLETE AND THE SITE IS STABILIZED, REMOVE SILT FENCE AND RESEED ANY AREAS DISTURBED BY THE REMOVAL. 3.SITE DATA: AREA OF DISTURBANCE:1.493± AC PRE-CONSTRUCTION IMPERVIOUS AREA:1.228± AC POST-CONSTRUCTION IMPERVIOUS AREA:1.057± AC GENERAL SOIL TYPE:SEE GEOTECHNICAL REPORT 4.THE LOCATION OF AREAS NOT TO BE DISTURBED MUST BE IDENTIFIED WITH FLAGS, STAKES, SIGNS, SILT FENCE, ETC. BEFORE CONSTRUCTION BEGINS. 5.ALL DISTURBED GROUND LEFT INACTIVE FOR SEVEN (7) OR MORE DAYS SHALL BE STABILIZED BY SEEDING OR SODDING (ONLY AVAILABLE PRIOR TO SEPTEMBER 15) OR BY MULCHING OR COVERING OR OTHER EQUIVALENT CONTROL MEASURE. 6.ON SLOPES 3:1 OR GREATER MAINTAIN SHEET FLOW AND MINIMIZE RILLS AND/OR GULLIES, SLOPE LENGTHS CAN NOT BE GREATER THAN 75 FEET. DENOTES SLOPES GREATER THAN 3:1. ALL 3:1 SLOPES TO BE STABILIZED WITH EROSION CONTROL BLANKET 7.ALL STORM DRAINS AND INLETS MUST BE PROTECTED UNTIL ALL SOURCES OF POTENTIAL DISCHARGE ARE STABILIZED. 8.TEMPORARY SOIL STOCKPILES MUST HAVE EFFECTIVE SEDIMENT CONTROL AND CAN NOT BE PLACED IN SURFACE WATERS OR STORM WATER CONVEYANCE SYSTEMS. TEMPORARY STOCKPILES WITHOUT SIGNIFICANT AMOUNT OF SILT, CLAY, OR ORGANIC COMPOUNDS ARE EXEMPT EX: CLEAN AGGREGATE STOCK PILES, DEMOLITION CONCRETE STOCKPILES, SAND STOCKPILES. 9.SEDIMENT LADEN WATER MUST BE DISCHARGED TO A SEDIMENTATION BASIN WHENEVER POSSIBLE. IF NOT POSSIBLE, IT MUST BE TREATED WITH THE APPROPRIATE BMP'S. 10.SOLID WASTE MUST BE DISPOSED OF PROPERLY AND MUST COMPLY WITH MPCA DISPOSAL REQUIREMENTS. 11.EXTERNAL WASHING OF CONSTRUCTION VEHICLES MUST BE LIMITED TO A DEFINED AREA OF THE SITE, RUNOFF MUST BE PROPERLY CONTAINED. 12.NO ENGINE DEGREASING IS ALLOWED ON SITE. 13.THE OWNER WHO SIGNS THE NPDES PERMIT APPLICATION IS A PERMITTEE AND IS RESPONSIBLE FOR COMPLIANCE WITH ALL TERMS AND CONDITIONS OF THE PERMIT. THE OPERATOR (CONTRACTOR) WHO SIGNS THE NPDES PERMIT APPLICATION IS A PERMITTEE FOR ALL APPLICABLE CONSTRUCTION ACTIVITY REQUIREMENTS FOUND IN SECTIONS 3, 4, 6-24 OF THE NPDES PERMIT AND IS JOINTLY RESPONSIBLE WITH THE OWNER FOR COMPLIANCE WITH THOSE PORTIONS OF THE PERMIT. 14.TERMINATION OF COVERAGE-PERMITTEE(S) WISHING TO TERMINATE COVERAGE MUST SUBMIT A NOTICE OF TERMINATION (NOT) TO THE MPCA. ALL PERMITTEE(S) MUST SUBMIT A NOT WITHIN 30 DAYS AFTER ONE OR MORE OF THE FOLLOWING CONDITIONS HAVE BEEN MET: A.FINAL STABILIZATION, PER NPDES PERMIT SECTION 13 HAS BEEN ACHIEVED ON ALL PORTIONS OF THE SITE FOR WHICH THE PERMITTEE IS RESPONSIBLE. B.TRANSFER OF OWNERSHIP AS DESCRIBED IN THE PERMIT. 15. INSPECTIONS A.INITIAL INSPECTION FOLLOWING SILT FENCE INSTALLATION BY CITY REPRESENTATIVE IS REQUIRED. B.EXPOSED SOIL AREAS: ONCE EVERY 7 DAYS AND WITHIN 24 HOURS FOLLOWING A 0.5" OVER 24 HOUR RAIN EVENT. C.STABILIZED AREAS: ONCE EVERY 30 DAYS D.FROZEN GROUND: AS SOON AS RUNOFF OCCURS OR PRIOR TO RESUMING CONSTRUCTION. E.INSPECTION AND MAINTENANCE RECORDS MUST BE RETAINED FOR 3 YEARS AFTER FILING OF THE NOTICE OF TERMINATION AND MUST INCLUDE: DATE AND TIME OF ACTION, NAME OF PERSON(S) CONDUCTING WORK, FINDING OF INSPECTIONS AND RECOMMENDATIONS FOR CORRECTIVE ACTION, DATE AND AMOUNT OF RAINFALL EVENTS GREATER THAN 0.5 INCHES IN A 24 HOUR PERIOD. 16. MINIMUM MAINTENANCE A.SILT FENCE TO BE REPAIRED, REPLACED, SUPPLEMENTED WHEN NONFUNCTIONAL, OR 1/3 FULL; WITHIN 24 HOURS B.SEDIMENT BASINS DRAINED AND SEDIMENT REMOVED WHEN REACHES 1/2 STORAGE VOLUME. REMOVAL MUST BE COMPLETE WITHIN 72 HOURS OF DISCOVERY. C.SEDIMENT REMOVED FROM SURFACE WATERS WITHIN (7)SEVEN DAYS D.CONSTRUCTION SITE EXITS INSPECTED, TRACKED SEDIMENT REMOVED WITH 24 HOURS. E.PROVIDE COPIES OF EROSION INSPECTION RESULTS TO CITY ENGINEER FOR ALL EVENTS GREATER THAN 12" IN 24 HOURS 17.THE SWPPP, INCLUDING ALL CHANGES TO IT, AND INSPECTIONS AND MAINTENANCE RECORDS MUST BE KEPT AT THE SITE DURING CONSTRUCTION ACTIVITY BY THE PERMITTEE(S) WHO HAVE OPERATIONAL CONTROL OF THE SITE. 18.OWNER MUST KEEP RECORDS OF ALL PERMITS REQUIRED FOR THE PROJECT, THE SWPPP, ALL INSPECTIONS AND MAINTENANCE, PERMANENT OPERATION AND MAINTENANCE AGREEMENTS, AND REQUIRED CALCULATIONS FOR TEMPORARY AND PERMANENT STORM WATER MANAGEMENT SYSTEMS. THESE RECORDS MUST BE RETAINED FOR THREE YEARS AFTER FILING NPDES NOTICE OF TERMINATION. 19.SWPPP MUST BE AMENDED WHEN: A.THERE IS A CHANGE IN DESIGN, OPERATION, MAINTENANCE, WEATHER OR SEASONAL CONDITIONS THAT HAS A SIGNIFICANT EFFECT ON DISCHARGE B.INSPECTIONS INDICATE THAT THE SWPPP IS NOT EFFECTIVE AND DISCHARGE IS EXCEEDING WATER QUALITY STANDARDS. C.THE BMP'S IN THE SWPPP ARE NOT CONTROLLING POLLUTANTS IN DISCHARGES OR IS NOT CONSISTENT WITH THE TERMS AND CONDITIONS OF THE PERMIT. 20.CONCRETE WASHOUT AREA A.CONCRETE WASH-OUT IS NOT ALLOWED ON-SITE. 21.IN THE EVENT OF ENCOUNTERING A WELL OR SPRING DURING CONSTRUCTION CONTRACTOR TO CEASE CONSTRUCTION ACTIVITY AND NOTIFY ENGINEER. 22.PIPE OUTLETS MUST BE PROVIDED WITH TEMPORARY OR PERMANENT ENERGY DISSIPATION WITHIN 24 HOURS AFTER CONNECTION TO A SURFACE WATER. 23.FINAL STABILIZATION FINAL STABILIZATION REQUIRES THAT ALL SOIL DISTURBING ACTIVITIES HAVE BEEN COMPLETED AND THAT DISTURBED AREAS ARE STABILIZED BY A UNIFORM PERENNIAL VEGETATIVE COVER WITH 70% OF THE EXPECTED FINAL DENSITY, AND THAT ALL PERMANENT PAVEMENTS HAVE BEEN INSTALLED. ALL TEMPORARY BMP'S SHALL BE REMOVED, DITCHES STABILIZED, AND SEDIMENT SHALL BE REMOVED FROM PERMANENT CONVEYANCES AND SEDIMENTATION BASINS IN ORDER TO RETURN THE POND TO DESIGN CAPACITY. 24. TEMPORARY SEDIMENTATION BASINS A.THE TEMPORARY SEDIMENTATION BASINS SHALL BE CONSTRUCTED AND MADE OPERATIONAL PRIOR TO DISTURBANCE OF 10 OR MORE ACRES DRAINING TO A COMMON LOCATION. B.TEMPORARY SEDIMENTATION BASINS ARE REQUIRED PRIOR TO RUNOFF LEAVING THE CONSTRUCTION SITE OR ENTERING SURFACE WATERS WHEN 10 OR MORE ACRES OF DISTURBED SOILS DRAIN TO A COMMON LOCATION. THE BASIN MUST PROVIDE 3,600 CUBIC FEET OF STORAGE BELOW THE OUTLET PER ACRE DRAINED. IF HYDRAULIC CALCULATIONS ARE AVAILABLE, THE TEMPORARY SEDIMENTATION BASIN MUST PROVIDE A STORAGE VOLUME EQUIVALENT TO THE 2-YEAR, 24-HOUR STORM, BUT IN NO CASE LESS THAN 1800 CUBIC FEET PER ACRE DRAINED. THE TEMPORARY SEDIMENTATION BASIN MUST BE CONSTRUCTED AND MADE OPERATIONAL CONCURRENT WITH THE START OF SOIL DISTURBANCE UP GRADIENT OF THE POND. THE TEMPORARY SEDIMENTATION BASIN SHALL BE DESIGNED TO PREVENT SHORT CIRCUITING. THE OUTFALL SHALL BE DESIGNED TO REMOVE FLOATABLE DEBRIS, ALLOW FOR COMPLETE DRAWDOWN OF THE POND FOR MAINTENANCE ACTIVITIES, AND HAVE ENERGY DISSIPATION. THE EMERGENCY SPILLWAY SHALL BE STABILIZED. C.TEMPORARY SEDIMENTATION BASINS SHALL BE SITUATED OUTSIDE OF SURFACE WATERS AND ANY REQUIRED BUFFER ZONE, AND MUST BE DESIGNED TO AVOID DRAINING WETLANDS, UNLESS THE IMPACT IS IN COMPLIANCE WITH THE REQUIREMENTS OF THIS PERMIT. D.EXCESSIVE SEDIMENT-LADEN WATER THAT IS NOT PROPERLY FILTERED WILL NOT BE PERMITTED TO DISCHARGE FROM SITE. 25.DEWATERING AND BASIN DRAINING A.TURBID OR SEDIMENT-LADEN WATERS RELATED TO DEWATERING OR BASIN DRAINING SHALL BE DISCHARGED TO A TEMPORARY OR PERMANENT SEDIMENTATION BASIN ON THE PROJECT SITE UNLESS INFEASIBLE. THE TEMPORARY OR PERMANENT BASIN MAY DISCHARGE TO SURFACE WATERS IF THE BASIN WATER HAS BEEN VISUALLY CHECKED TO ENSURE ADEQUATE TREATMENT HAS BEEN OBTAINED IN THE BASIN AND THAT THE NUISANCE CONDITIONS WILL NOT RESULT FROM THE DISCHARGE. DISCHARGE POINTS SHALL BE ADEQUATELY PROTECTED FROM EROSION AND PROPER VELOCITY DISSIPATION PROVIDED. B.ALL WATER FROM DEWATERING OR BASIN-DRAINING ACTIVITIES MUST BE DISCHARGED IN A MANNER THAT DOES NOT CAUSE NUISANCE CONDITIONS, EROSION IN THE RECEIVING CHANNELS OR ON DOWN SLOPE PROPERTIES, OR INUNDATION IN WETLANDS CAUSING SIGNIFICANT ADVERSE IMPACTS TO THE WETLAND. C.IF FILTERS WITH BACKWASH WATERS ARE USED, THE BACKWASH WATER SHALL BE HAULED AWAY FOR DISPOSAL, RETURNED TO THE BEGINNING OF THE TREATMENT PROCESS, OR INCORPORATED INTO SITE IN A MANNER THAT DOES NOT CAUSE EROSION. BACKWASH WATER MAY BE DISCHARGED TO SANITARY SEWER IF PERMISSION IS GRANTED BY THE SANITARY SEWER AUTHORITY. 26.POLLUTION PREVENTION A.BUILDING PRODUCTS THAT HAVE THE POTENTIAL TO LEACH POLLUTANTS MUST BE UNDER COVER TO PREVENT DISCHARGE OR PROTECTED BY AN EFFECTIVE MEANS DESIGNED TO MINIMIZE CONTACT WITH STORMWATER. B.PESTICIDES, HERBICIDES, INSECTICIDES, FERTILIZERS, TREATMENT CHEMICALS, AND LANDSCAPE MATERIALS MUST BE UNDER COVER. C.HAZARDOUS MATERIALS AND TOXIC WASTE MUST BE PROTECTED TO PREVENT VANDALISM. D.SOLID WASTE MUST BE STORED, COLLECTED AND DISPOSED OF IN COMPLIANCE WITH MINN. R. CH 7035. E.PORTABLE TOILETS MUST BE POSITIONED SO THAT THEY ARE SECURE AND WILL NOT BE TIPPED OR KNOCKED OVER. SANITARY WASTE MUST BE DISPOSED OF PROPERLY IN ACCORDANCE WITH MINN. R. CH 7041. F.DISCHARGE OF SPILLED OR LEAKED CHEMICALS, INCLUDING FUEL, FROM ANY AREA WHERE CHEMICALS OR FUEL WILL BE LOADED OR UNLOADED SHALL BE PREVENTED USING DRIP PANS OR ABSORBENTS. SUPPLIES SHALL BE AVAILABLE AT ALL TIMES TO CLEAN UP DISCHARGED MATERIALS AND THAT AN APPROPRIATE DISPOSAL METHOD MUST BE AVAILABLE FOR RECOVERED SPILLED MATERIALS. 27. DESIGN CALCULATIONS TEMPORARY & PERMANENT STORMWATER TREATMENT ARE DESIGNED TO MEET MPCA GENERAL & SPECIAL WATER REQUIREMENTS. CALCULATIONS ARE PART OF THE HYDROLOGY REPORT, WHICH IS TO BE CONSIDERED PART OF THE SWPP DOCUMENTS. SEE HYDROLOGY REPORT FOR ADDITIONAL INFORMATION. 28.GENERAL STORMWATER DISCHARGE REQUIREMENTS ALL REQUIREMENTS LISTED IN SECTIONS 5-7, 14, 16-19, 21, 24 OF THE PERMIT FOR DESIGN OF THE PERMANENT STORMWATER MANAGEMENT SYSTEM AND DISCHARGE HAVE BEEN INCLUDED IN THE PREPARATION OF THIS SWPP. THESE INCLUDE BUT ARE NOT LIMITED TO: A.THE EXPECTED AMOUNT, FREQUENCY, INTENSITY, AND DURATION PRECIPITATION. B.THE NATURE OF STORMWATER RUNOFF AND RUN-ON AT THE SITE. C.PEAK FLOW RATES AND STORMWATER VOLUMES TO MINIMIZE EROSION AT OUTLETS AND DOWNSTREAM CHANNEL AND STREAM BANK EROSION. D.THE RANGE OF SOIL PARTICLE SIZES EXPECTED TO BE PRESENT ON THE SITE. 29.CONSTRUCTION OF FILTRATON BASINS A.NO HEAVY TRAFFIC ON FILTRATON AREAS. CONSTRUCTION TO BE DONE WITH MINIMAL COMPACTION TO FILTRATON AREAS. IF COMPACTION IS ENCOUNTERED, BASIN SOILS FOR THE FIRST & MUST BE REMOVED & RELAID. B.FILTRATON SYSTEMS MUST NOT BE EXCAVATED TO FINAL GRADE UNTIL THE CONTRIBUTING DRAINAGE AREA HAD BEEN CONSTRUCTED AND FULLY STABILIZED UNLESS RIGOROUS EROSION PREVENTION AND SEDIMENT CONTROLS ARE PROVIDED( SECTION 16.4). C.WHEN AN FILTRATON SYSTEM IS EXCAVATED TO FINAL GRADE (OR WITHIN THREE (3) FEET OF FINAL GRADE), THE PERMITTEE(S) MUST EMPLOY RIGOROUS EROSION PREVENTION AND SEDIMENT CONTROLS (E.G., DIVERSION BERMS) TO KEEP SEDIMENT AND RUNOFF COMPLETELY AWAY FROM THE FILTRATON AREA. THE AREA MUST BE STAKED OFF AND MARKED SO THAT HEAVY CONSTRUCTION VEHICLES OR EQUIPMENT WILL NOT COMPACT THE SOIL IN THE PROPOSED FILTRATON AREA. D.TO PREVENT CLOGGING OF THE FILTRATON SYSTEM, THE PERMITTEE(S) MUST USE A PRETREATMENT DEVICE SUCH AS A VEGETATED FILTER STRIP, SMALL SEDIMENTATION BASIN, OR WATER QUALITY INLET (E.G., GRIT CHAMBER) TO SETTLE PARTICULATES BEFORE THE STORMWATER DISCHARGES INTO THE FILTRATON SYSTEM. E.FILTRATON BASIN SHALL BE CONSTRUCTED IN DRY SOIL CONDITIONS. F.EXCAVATION, SOIL PLACEMENT, AND RAPID STABILIZATION OF PERIMETER SLOPES MUST BE ACCOMPLISHED PRIOR TO THE NEXT PRECIPITATION EVENT. G.EXCAVATION AND PLACEMENT OF MATERIALS SHALL BE PERFORMED BY AN EXCAVATOR WITH A TOOTHED BUCKET. 30.POST CONSTRUCTION THE WATER QUALITY VOLUME THAT MUST BE RETAINED ON SITE BY THE PROJECT'S PERMANENT STORMWATER MANAGEMENT SYSTEM DESCRIBED IN SECTION 15 SHALL BE ONE (1) INCH OF RUNOFF FROM THE NEW IMPERVIOUS SURFACES CREATED BY THE PROJECT. SEE SECTION 15. FOR MORE INFORMATION ON FILTRATON DESIGN, PROHIBITIONS AND APPROPRIATE SITE CONDITIONS. 31.RESPONSIBILITIES A.THE OWNER MUST IDENTIFY A CONTRACTOR WHO WILL OVERSEE THE SWPPP IMPLEMENTATION AND THE PERSON RESPONSIBLE FOR INSPECTION AND MAINTENANCE: B.THE OWNER MUST IDENTIFY THE A PERSON WHO WILL BE RESPONSIBLE FOR LONG TERM OPERATIONS AND MAINTENANCE OF THE PERMANENT STORMWATER MANAGEMENT SYSTEM: 32.TRAINING REQUIREMENTS THE PERMITTES(S) SHALL ENSURE THE FOLLOWING INDIVIDUALS IDENTIFIED IN THIS PART HAVE BEEN TRAINED IN ACCORDANCE WITH THIS PERMIT'S TRAINING REQUIREMENTS. 1. WHO MUST BE TRAINED: A. INDIVIDUAL(S) PREPARING THE SWPPP FOR THE PROJECT B. INDIVIDUAL(S) OVERSEEING IMPLEMENTATION OF, REVISING, AND/OR AMENDING THE SWPPP AND INDIVIDUALS(S) PERFORMING INSPECTIONS FOR THE PROJECT. ONE OF THESE INDIVIDUAL(S) MUST BE AVAILABLE FOR AN ONSITE INSPECTION WITHIN 72 HOURS UPON REQUEST BY THE MPCA. C.INDIVIDUAL(S) PERFORMING OR SUPERVISING THE INSTALLATION, MAINTENANCE AND REPAIR OF BMPS. AT LEAST ONE INDIVIDUAL ON A PROJECT MUST BE TRAINED IN THESE JOB DUTIES. 2.TRAINING CONTENT: THE CONTENT AND EXTENT OF TRAINING MUST BE COMMENSURATE WITH THE INDIVIDUAL'S JOB DUTIES AND RESPONSIBILITIES WITH REGARD TO ACTIVITIES COVERED UNDER THIS PERMIT FOR THE PROJECT. AT LEAST ONE INDIVIDUAL PRESENT ON THE PERMITTED PROJECT SITE (OR AVAILABLE TO THE PROJECT SITE IN 72 HOURS) MUST BE TRAINED IN THE JOB DUTIES DESCRIBED IN SECTION 21.2B AND SECTION 21.2C. 33.THE PERMITTEE(S) SHALL ENSURE THAT THE INDIVIDUALS ARE TRAINED BY LOCAL, STATE, FEDERAL AGENCIES, PROFESSIONAL OR OTHER ENTITIES WITH EXPERTISE IN EROSION PREVENTION, SEDIMENT CONTROL, PERMANENT STORMWATER MANAGEMENT AND THE MINNESOTA NPDES/SDS CONSTRUCTION STORMWATER PERMIT. AN UPDATE REFRESHER-TRAINING MUST BE ATTENDED EVERY THREE (3) YEARS STARTING THREE (3) YEARS FROM THE ISSUANCE DATE OF THIS PERMIT. 33.LIST OF CONTACTS * MPCA 24HR. HAZARDOUS SPILL HOTLINE: 651-649-5457 OF 80420798 DESCRIPTION UNIT TEMPORARY ROCK CONSTRUCTION ENTRANCE EA PREFABRICATED CONCRETE WASHOUT EA SILT FENCE (STANDARD)LF EROSION CONTROL BLANKET SY INLET PROTECTION EA QUANTITY 1 NOT ALLOWED 760 855 10 POST CONSTRUCTION SILT FENCE (STANDARD)LF 585 NAME OF WATER BODY TYPE OF WATER BODY SPECIAL WATER IMPAIRED WATER TYPE OF SPECIAL WATER LILLY LAKE LAKE NO YES TITLE NAME OWNER . COMPANY PHONE NUMBER PARK DENTAL GROUP PROJECT MANAGER VICKI VAN DELL LOUCKS 763-496-6720 ENGINEER SWPPP ZACHARY WEBBER 763-496-6753LOUCKS CONTRACTOR SITE MANGER ERIC OLSON . SWPPP NOTES ESTIMATED QUANTITIES SPECIAL & IMPAIRED WATERS WITHIN ONE MILE OF THE PROJECT CERTIFICATION SPECIAL & IMPAIRED WATERS WITHIN ONE MILE OF THE PROJECT RJM CONSTRUCTION 952-837-8600 ERIC OLSON RJM CONSTRUCTION 952-837-8600 NO PARKING NO PARKING PROPOSED BUILDING FFE=938.00 60TH STREET N. FUTURE ADDITION FFE=938.00 8 8 8 8 8 8888888888FILTRATION BASIN 1 NWL=DRY BTM=931.50 HWL=934.16 MEDIA INV=929.50 6" DT INV=929.50 FILTRATION BASIN 2 NWL=DRY BTM=934.30 HWL=935.99 MEDIA INV=932.30 6" DT INV=932.30448CB 104 RIM= 936.50 INV=932.82 (12") E 62 LF 12" HDPE @ 0.44% CBMH 101 RIM= 934.35 INV= 931.61 (15") S INV=931.61 (15") W SUMP=928.61 FES 100 INV= 931.50 (15") E CBMH 103 RIM= 936.50 INV= 932.55 (12") W INV=932.55 (12") E CBMH 102 RIM= 937.20 INV= 932.34 (12") W INV=932.14 (15") N 48 LF 12" HDPE @ 0.44% 166 LF 15" HDPE @ 0.32% 20 LF 18" RCP @ 0.98% FES 200 INV=933.00 (18") NW 38 LF 15" RCP @ 0.30% RAIN GUARDIAN RIM=936.00 RAIN GUARDIAN RIM=936.00 8 CY RIP RAP 8 CY RIP RAP SANITARY SEWER SERVICE SHALL CONNECT TO SANITARY STUB 8 CY RIP RAP CORE DRILL INTO EXISTING MANHOLE INV=932.80 EX. INV=930.27 VERIFIED BY CONTRACTOR WET TAP EXISTING 12" WATERMAIN EMERGENCY OVERFLOW RIP RAP CBMH 101 SHALL HAVE THE PRESERVER (SEE DETAIL) 6" GATE VALVE 6" COMBINED WATER SERVICE COORDINATE WITH MECH. FOR CONTINUATION IN BUIDLING 6" DIP CL 52 WATERMAIN APPROXIMATE LOCATION OF EXISTING 12" WATERMAIN CONTRACTOR TO FIELD VERIFY TRANSFORMER EXISTING PARK DENTAL BUILDING PER SURVEY BY OTHERS 2-45° BENDS 2-45° BENDS 12" ROOF DRAIN INV=934.00 12 LF 12" PVC SCH 40 @ 1.67% 8 CY RIP RAP DAYLIGHT ROOF DRAIN INV=933.80 SANITARY SEWER SHALL BE COORDINATED WHEN MORE INFORMATION BECOMES AVAILABLE CLEANOUT RIM=936.00 INV=932.30 CLEANOUT RIM=936.00 INV=932.30 180 LF 6" PERF. DT @ 0.00% 19 LF 6" PERF. DT @ 0.00% CORE DRILL INTO EX. CB INV=932.00 EX. INV=930.00 VERIFIED BY CONTRACTOR CLEANOUT RIM=933.00 INV=929.50 CLEANOUT RIM=933.00 INV=929.50 41 LF 6" NON-PERF. DT @ 1.00% 22 LF 6" NON-PERF. DT @ 1.3% 255 TOTAL LF 6" PERF. DT @ 0.00% CORE DRILL INTO EX. CB INV=929.08 VERIFIED BY CONTRACTOR CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /16 / 2022 11:34 AMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C4-1 Utility PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 N SCALE IN FEET 0 20 40 NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY WESTWOOD PROFESSIONAL SERVICES, DATED 06/22/18. TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT , AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 2018 EDITION. 2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT. 3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES. THE CITY OR ITS DESIGNEE SHALL BE PRESENT FOR WATER AND SEWER SERVICE CONNECTIONS TO THE CITY'S SYSTEMS. 4.ALL STORM SEWER , SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE BUILDING FACE UNLESS OTHERWISE NOTED. 5.A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FOR ALL UTILITES UNLESS OTHERWISE NOTED. 6.ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 7.5 FEET OF COVER. EXTRA DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY OR STORM SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID CONFLICTS WITH SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATER AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 7.5 FEET MINIMUM DEPTH CAN NOT BE ATTAINED. 7.ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 8.PROPOSED PIPE MATERIALS: WATERMAIN CL 52 DIP (POLY WRAPPED)6" DIAMETER SANITARY SEWER PVC SDR 35 & SCH 40 6" DIAMETER STORM SEWER PVC SCH 40, HDPE, & RCP 12" TO 15" DIAMETER 9.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA RULES, PART 4715.2820 10.ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT (SEE MINNESOTA RULES, PART 4715.0700). APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, AND OTHER STRUCTURES. 11.HIGH-DENSITY POLYETHYLENE (HDPE) STORM DRAINS MUST COMPLY WITH MINNESOTA RULES, PART 4715.0540: a.PIPES 4-INCH TO 10-INCH IN SIZE MUST COMPLY WITH AASHTO M252. b.PIPES 12-INCH TO 60-INCH IN SIZE MUST COMPLY WITH ASTM F2306. c.ALL FITTINGS MUST COMPLY WITH ASTM D3212. d.WATER-TIGHT JOINTS MUST BE USED AT ALL CONNECTIONS INCLUDING STRUCTURES. 12. CONTRACTOR AND MANHOLE FABRICATOR SHALL SUMP (LOWER) ALL STORM SEWER CATCH BASIN CASTINGS WITHIN PAVED AREAS 0.16 FEET OR 2-INCHES BELOW THE RIM ELEVATION DEPICTED ON THE UTILITY PLAN. 13.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MMUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD CLOSURES SHALL BE PERMITTED WITHOUT THE EXPRESSED AUTHORITY OF OF THE CITY. 14.THE CITY SHALL OPERATE ALL GATE VALVES. 15.CONNECTIONS TO EXISTING MANHOLES SHALL BE MADE BY CORE DRILLING THE MANHOLE AT THE PROPOSED INVERT ELEVATIONS AND INSTALLING A RUBBER BOOT. GROUT IN THE BOOT AND AN INVERT FOR THE NEW SEWER LINE. 16.PIPE LENGTHS SHOWN ON THE PLAN DO NOT INCLUDE THE APRON SECTION. 17.WATERMAIN PIPE SHALL BE DIP CLASS 52, INSTALLED WITH 7.5 FEET OF COVER TO TOP PIPE. FITTINGS SHALL BE COMPACT TYPE. PIPE AND FITTINGS SHALL HAVE A CEMENT MORTAR LINING. CONDUCTIVITY SHALL BE PROVIDED BY WELDED STRAPS ACROSS EACH JOIN.T 18.TRENCH COMPACTION SHALL BE 95% STANDARD PROCTOR DENSITY IN THE AREA FROM THE PIPE ZONE TO WITHIN 3 FEET OF FINISHED GRADE AND 100% IN FINAL 3 FEET OF THE BACKFILL TO FINISH GRADE. UTILITY NOTES UTILITY PLAN C4-1 UTILITY STRUCTURE SCHEDULE STRUCTURE NO.CASTING MANHOLE SIZE CBMH 103 48" CB 104 48" 2'x3' CBMH 101 R-3067 15"FES 100 FES 200 18" CBMH 102 48"R-3067 R-3067 R-3067 CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:28 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C8-1 Civil DetailsOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 CIVIL DETAILS C8-1 CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:28 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C8-1 Civil DetailsOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 CIVIL DETAILS C8-2 SLOPE GUTTER TO MATCH PARKING LOT DRAINAGE (3/4" PER FT. TYP.) TIP GUTTER OUT AS REQ'D PAVEMENT SECTION VARIES MIN. OF 4" 3/8 " LIP MINIMUM 1' BEHIND BACK OF CURBAGG. BASE UNDER CURB (IF TOTAL THICKNESS OF SECTION ALLOWS) 7" 12"8" AGG. BASE VARIES 1/2" RAD. 20" FLAT CURB AND GUTTER (12") SPECIFICATION NOTES: 1.UPON COMPLETION, CURBING SHOULD BE SPRAYED WITH A MEMBRANE CURING COMPOUND PER MNDOT 3754. 2.EXPANSION JOINTS AT MAX. SPACING OF 200'. 3.CONSTRUCT IN ACCORDANCE WITH MNDOT 2531. 4.THE GAP BETWEEN THE SIDEWALK AND CONCRETE CURB (B612 OR FLUSH CURB) TO BE A MAXIMUM OF 14" WITH TYPICAL PRE-MOLDED EXPANSION JOINT MATERIAL - NO PLASTIC INSETS DRAWN 2/2016 LOUCKS PLATE NO. 2012LOUCKS STANDARD GUTTER 8"A 6" 13.5" 12" RAD. 24"B624 B618 18" B612 12" CURB TYPE "A" MIN. OF 4" AGG. BASE UNDER CURB (IF TOTAL THICKNESS OF SECTION ALLOWS) 3/8 " LIP 3" RAD. 1 3 3" RAD. AGG. BASE VARIES PAVEMENT SECTION VARIES SEE PAVEMENT SECTION DETAIL SLOPE GUTTER TO MATCH PARKING LOT DRAINAGE (3/4" PER FT. TYP.) TIP GUTTER OUT AS REQ'D B6 STYLE CONCRETE CURB AND GUTTER MINIMUM 1' BEHIND BACK OF CURB 7" SPECIFICATION NOTES: 1.UPON COMPLETION, CURBING SHOULD BE SPRAYED WITH A MEMBRANE CURING COMPOUND PER MNDOT 3754. 2.EXPANSION JOINTS AT MAX. SPACING OF 200'. 3.CONSTRUCT IN ACCORDANCE WITH MNDOT 2531. 4.THE GAP BETWEEN THE SIDEWALK AND CONCRETE CURB (B612 OR FLUSH CURB) TO BE A MAXIMUM OF 14" WITH TYPICAL PRE-MOLDED EXPANSION JOINT MATERIAL - NO PLASTIC INSETS. DRAWN 2/2016 LOUCKS PLATE NO. 2009LOUCKS CONCRETE SIDEWALK SECTION 4" CONCRETE WALK MN/DOT 2521 4" GRANULAR MATERIAL MN/DOT 3149 DRAWN 12/2016 LOUCKS PLATE NO. 2034LOUCKS 1.5" BIT. WEAR COURSE, MN/DOT 2360 SPWEA240F TACK COAT, MN/DOT 2357 2" BIT. NON-WEAR COURSE, MN/DOT 2360 SPNWB230E 6" AGG. BASE, CLASS 5 OR 6 MN/DOT 3138 APPROVED SUBGRADE FINISHED GRADE STANDARD BITUMINOUS PAVEMENT SECTION PAVEMENT SECTION BASED ON GEOTECHNICAL REPORT BY AMERICAN ENGINEERING TESTING INC., DATED AUGUST 3, 2021 DRAWN 12/2016 LOUCKS PLATE NO. 2031LOUCKS XX" BIT. WEAR COURSE, MN/DOT 2360 SPWEA240B TACK COAT, MN/DOT 2357 XX" BIT. NON-WEAR COURSE, MN/DOT 2360 SPNWB230B XX" AGG. BASE, CLASS 5 OR 2 MN/DOT 3138 APPROVED SUBGRADE FINISHED GRADE HEAVY DUTY BITUMINOUS PAVEMENT SECTION PAVEMENT SECTION BASED ON GEOTECHNICAL REPORT BY AMERICAN ENGINEERING TESTING INC., DATED AUGUST 3, 2021 DRAWN 12/2016 LOUCKS PLATE NO. 2032LOUCKS RIBBON CURB MAXIMUM 1/4" LIP 10-FT CURB TRANSITION FROM 6" TO 0" 10-FT CURB TRANSITION FROM 6" TO 0" B612 CURB & GUTTER 6" CURB HEIGHT B612 CURB & GUTTER 6" CURB HEIGHT RAISE BITUMINOUS TO PROVIDE A TRANSITION FROM 6" HIGH CURB TO 0" HIGH RIBBON CURB IN 10'. BOTH SIDES OF ACCESSIBLE STALLS. SIDEWALK TO BE FLUSH WITH PAVEMENT CURB / BITUMINOUS TRANSITION DRAWN 12/2016 LOUCKS PLATE NO. 2043LOUCKS 6" COMPACTED AGGREGATE BASE CL. 5 OR 2 MN/DOT 3138 APPROVED SUBGRADE FINISHED GRADE 7" CONCRETE MN/DOT 2301 CONCRETE PAVEMENT SECTION NOTES: 1.CONCRETE 6" THICK OR LESS SHALL BE REINFORCED WITH WELDED WIRE FABRIC OR REINFORCING BARS. CONCRETE 7" THICK OR GREATER SHALL BE REINFORCED PER GEOTECHNICAL RECOMMENDATIONS. 2.SAWED OR FORMED CONTROL JOINTS SHOULD BE INCLUDED FOR EACH 225 SQUARE FEET OF AREA OR LESS (15 FEET BY 15 FEET). 3.SAW CUTS SHOULD NOT CUT THROUGH THE WELDED WIRE FABRIC OR REINFORCING STEEL AND DOWELS SHOULD BE UTILIZED AT FORMED AND/OR COLD JOINTS. DRAWN 12/2016 LOUCKS PLATE NO. 2033LOUCKS TYPICAL ADA PARKING STALL STRIPING DRAWN 03/2017 LOUCKS PLATE NO. 2037LOUCKS LCC 4" WIDE PAINTED LINES, TRAFFIC WHITE 4" WIDE PAINTED LINES, 18" O.C., @ 45 DEG. TRAFFIC WHITE (AISLE TO CONTAIN THE DESIGNATION "NO PARKING" COMPLYING WITH MSBC 1341.0502 IF ACCESS AISLE SIGNS ARE NOT SHOWN REFER TO SITE PLAN FOR ADA PARKING SIGN LOCATION REFER TO SITE PLAN FOR ACCESS AISLE SIGN LOCATION (AISLE TO CONTAIN THE DESIGNATION "NO PARKING" COMPLYING WITH MSBC 134.0502 IF ACCESS AISLE SIGNS ARE NOT SHOWN) REFER TO SITE PLAN FOR STALL DIMENSIONS 40"PROVIDE PAINTED INTERNATIONAL SYMBOL OF ACCESSIBILITY AT EACH DESIGNATED HANDICAP PARKING STALL. CENTER SYMBOL IN STALL. HC SIGNAGE PER MINNESOTA RULES 1341.0502 ALL LINES 4" WIDE 8" DIAMETER NOT TO SCALE 67.5° 5° 36" TRAFFIC SIGN 3#/FT. 3#/FT. TRAFFIC SIGN SPECIFICATIONS STOP SIGN SHALL BE R1-1, 30"X30" OR AS DIRECTED BY ENGINEER. MATERIAL ALUMINUM SHALL BE 5052-H38 OR 6061-T6 ALLOY. GAUGE SHALL BE 0.080 ON THE LONGEST SIDE UP TO 30", 0.100 ON THE LONGEST SIDE OVER 30". REFLECTIVE SHEETING SHALL BE DIAMOND GRADE VIP. ALL SIGNS SHALL CONFORM TO MN/DOT 3352, SIGNS, DELINEATORS AND MARKERS - STANDARD SPECIFICATIONS FOR CONSTRUCTION. CHANNEL POST SPECIFICATIONS STEEL CHANNEL POSTS SHALL WEIGH 3LB. /FT. POSTS SHALL BE OF THE 4-RIB DESIGN, GALVANIZED AND PUNCHED ON 1" CENTERS.3'-0"7'-0"IF INSTALLED IN PAVEMENT, INSTALL V-LOC ANCHOR OR APPROVED EQUAL. DRAWN 12/2016 LOUCKS PLATE NO. 2041LOUCKS VAN ACCESSIBLE 60" - 66"48"12" DIA.36"TYPICAL ADA PARKING SIGN / BOLLARD COMBO 12x18" STANDARD HANDICAP PARKING SIGN WITH SEPARATE 'VAN ACCESSIBLE' PANEL. WHITE LEGEND ON BLUE BACKGROUND. USE HARDWARE PER SIGN SUPPLIER'S RECOMMENDATIONS. HC SIGNAGE PER MINNESOTA RULES 1341.0502 12x6" STANDARD 'VAN ACCESSIBLE' PANEL. WHITE LEGEND ON BLUE BACKGROUND 2" DIA. 6' LONG MIN. GALVANIZED SCHEDULE 40 STEEL PIPE. EMBED IN CONCRETE FILLED BOLLARD 6" DIA. SCHEDULE 40 GALVENZIED STEEL PIPE 6' LONG MINIMUM HEAVY DUTY HDPE DOME TOP DECORATIVE SLEEVE BLUE IN COLOR. AVAILABLE FROM BOLLARDSNSLEEVES.COM OR EQUAL. COMPACTED OR UNDISTURBED SUBGRADE. NOTES: 1.BOLLARDS TO BE PLACED 12" BEHIND BACK OF CURB. 2.MAINTAIN PLUMB UNTIL CONCRETE IS SUFFICIENTLY CURED. 3.HOLD CONCRETE FOOTING BELOW GRADE OF FINISHED CONCRETE TO CREATE FINAL PAVING PATTERN AS SHOWN ON PLANS. DRAWN 12/2016 LOUCKS PLATE NO. 2038LOUCKS6"PARKING VEHICLE ID REQUIRED UP TO $200 FINE FOR VIOLATION HARD SURFACE PUBLIC ROAD 2' MINIMUM 1" TO 2" WASHED ROCK 50 ' M I N I M U M AS R E Q UI R E D4:1 4:1 6" MINIMUM ROCK ENTRANCE TO CONSTRUCTION SITE NOTES: 1.ROCK SIZE SHOULD BE 1" TO 2" IN SIZE SUCH AS MN/DOT CA-1 OR CA-2 COURSE AGGREGATE. (WASHED) 2.A GEOTEXTILE FABRIC MAY BE USED UNDER THE ROCK TO PREVENT MIGRATION OF THE UNDERLYING SOIL INTO THE STONE. DRAWN 2/2016 LOUCKS PLATE NO. 3004LOUCKS CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 05 /10 / 2022 1:28 PMW:\2021\21210\CADD DATA\CIVIL\_dwg Sheet Files\C8-1 Civil DetailsOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION PARK DENTAL ST. CROIX VALLEY OAK PARK HEIGHTS, MINNESOTA PARK DENTAL GROUP 2200 COUNTY ROAD C WEST, SUITE 2210 ROSEVILLE, MN 55113 9/14/21 CITY SUBMITTAL 11/3/21 REV. WATERSHED SUB 12/15/21 CD SET 02/17/22 CCD #1 05/10/22 CCD #4 Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Vicki J. Van Dell - PE Project Lead Drawn By Checked By Loucks Project No. 41352 21210 VJV ZHW VJV 05/10/22 12/01/21 ALTA/NSPS1 LAND TITLE SURVEY SITE PLANC2-1 GRADING PLANC3-1 SWPPP & NOTESC3-2 - C3-3 UTILITY PLANC4-1 DETAILSC8-1 - C8-3 LANDSCAPE PLANL1-1 DEMOLITION PLANC1-2 LANDSCAPE DETAILSL2-1 TREE INVENTORY PLANL0-1 2 1 EMERGENCY OVERFLOW- CLASS 2 RIP RAP OVER GEOTEXTILE FABRIC AS SPE C I F I E D 6' MI N. BASIN OVERFLOW TOP OF BERM OVERFLOW ELEVATION AS SPECIFIED PONDING AREA PROTECT SLOPE WITH RIP RAP & FABRIC. AS SPECIFIED DRAWN 2/2016 LOUCKS PLATE NO. 3010LOUCKS CIVIL DETAILS C8-3 48" 928.61 931 .61931 .61 934.37 *VERIFY RIM & INVERT ELEVATIONS WITH UTILITY PLAN. GRASS PRE-TREATMENT STRIP UNDISTURBED, UNCOMPACTED INSITU SOIL MULCH (MnDOT TYPE 1) LAYERED MEDIA SECTION TOP 6" - MEDIA MIX C MIDDLE 8" - ASTM 33 SAND BOTTOM 10" - ASTM 33 SAND WITH 5% IRON FILLING BY VOLUME D6" PERFORATED UNDERDRAIN OUTLET PIPE.24"3H:1L MAX. DEPTH REQUIRED TO DRAIN PRACTICE IN 48 HOURS OR LESS 1.5' MAXIMUM 2' CLAY LINER MEETING MPCA LEVEL 2 LINER SPECIFICATIONS NON-WOVEN GEOTEXTILE (MnDOT TYPE 1) OVER GRAVEL BLANKET - EXTENDING 1-2' FROM UNDERDRAIN PIPE SIDES. UNDERDRAIN GRAVEL BLANKET 1-1.5" DOUBLE WASHED STONE OR 14"-12" WASHED RIVER RUN PEA GRAVEL 1-2' FILTRATION BASIN CONSTRUCTION SEQUENCING FOR BASIN 1. INSTALL APPROPRIATE TEMPORARY EROSION CONTROL DEVICES TO PREVENT SEDIMENT FROM LEAVING OR ENTERING THE PRACTICE DURING CONSTRUCTION. 2. ALL DOWN GRADIENT PERIMETER CONTROL BMP'S MUST BE IN PLACE BEFORE ANY GRADIENT AND DISTURBING ACTIVITY BEGINS. 3. PERFORM CONTINUOUS INSPECTIONS OF EROSION CONTROL PRACTICES. 4. IF FILTRATION BASIN IS BEING USED AS TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION, LEAVE A MINIMUM OF 1' COVER OVER THE PRACTICE TO PROTECT THE UNDERLYING SOILS FROM CLOGGING. 5. COMPLETE, STABILIZE, AND VEGETATE ALL OTHER SITE IMPROVEMENTS. 6. CONSTRUCT AND VEGETATE FILTRATION DEVICE FOLLOWING STABILIZATION OF CONTRIBUTING DRAINAGE AREA. ENSURE THAT CRITICAL ELEVATIONS, SUCH AS UNDERDRAIN INVERT, TOP OF MULCH, AND INVERT OF OVERFLOW STRUCTURE ARE CORRECT. 7. REMOVE TEMPORARY EROSION CONTROL DEVICES AFTER THE CONTRIBUTING DRAINAGE AREA IS ADEQUATELY ESTABLISHED. GEBERAL NOTES 1. IN THE EVENT THAT SEDIMENT IS INTRODUCED INTO THE BMP DURING OR IMMEDIATELY FOLLOWING EXCAVATION, THIS MATERIAL SHALL BE REMOVED FROM THE PRACTICE PRIOR TO CONTINUING CONSTRUCTION. 2. SEE MINNESOTA STORMWATER MANUAL FOR SUBGRADE PREPARATION. NOTES: 6" HUB WITH THREADED PVC PLUG - DO NOT GLUE CASTING MAY BE REQUIRED SEE SPECIFICATIONS END OF LINE CLEANOUT IN LINE CLEANOUT PVC LONG SWEEP BEND SCH. 40 ONE PIECE 6" PVC SCH. 40 CLEANOUT RISER DRAINTILE CLEAN-OUT STRUCTURE 10' GREEN ENAMEL U-CHANNEL FENCE POST W/ TOP 6 INCHES WRAPPED WITH 3M SCOTCHLITE REFLECTIVE TAPE OR EQUAL. DRAWN 2/2016 LOUCKS PLATE NO. 4315LOUCKS