Loading...
HomeMy WebLinkAboutBP 2021-00146 Electrical Permit & Inspection ReportsDEPARTMENT OF 443 Lafayette Road N., St. Paul, MN 55155 LABOR AND INDUSTRY (651) 284-5026, www.dii.mn.gov Electrical Permit IP 22 )Zl _ I Wo Permit Number: ELE2201-08084 Permit Information as of 01/31/22 Structure Type: One -Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued Site County: Washington County Issued Date: 01/31/22 Site Address: 6188 Beach Rd, Oak Park Heights, MN 55082 Expiration Date: 01/31/23 Fees Paid: $71.00 Permit Applicant Information ONEILL ELECTRIC INC Phone: (651) 342-0906 ONEILL ELECTRIC INC Mobile: (651) 342-0906 6143 OSGOOD AVE N, STILLWATER, MN 55082 Email: Cydnie@oneillelectricmn.com Property Owner's Information American Home Remodeling Phone: (651) 342.0906 6188 Beach Rd, Stillwater, MN 55082 Contracted Electrical Inspector's Information Name: Donald Ede] Phone: (507) 210-8233 Don Edel Inspections LLC Email Address: mailto: don.edel.insoections@amail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough -In Inspection Required: Yes Number of Inspections Requested: 2 Project Description: Garage Remodel/ Lighting NA A rough -in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 01/31/2022 DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: Garage Remodel/ Lighting Permit Number: ELE2201-08084 Project location/address: 6188 Beach Rd, Oak Park Heights, Washington County, MN, 55082 Applicant: ONEILL ELECTRIC INC Phone: (651) 342-0906 Owner: American Home Remodeling Phone: (651) 342-0906 Inspection Type: Rough -In Result: Pass detached garage (rough -in) Inspected By: Donald Ede[ Phone: (507) 210-8233 Inspector Report Email: don.edel.inspections@gmail.com Date: 2/15/2022 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dli.mn.gov DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: Garage Remodel/ Lighting Permit Number: ELE2201-08084 Project location/address: 6188 Beach Rd, Oak Park Heights, Washington County, MN, 55082 Applicant: ONEILL ELECTRIC INC Phone: (651) 342-0906 Owner: American Home Remodeling Phone: (651) 342-0906 Inspection Type: Partial Final Result: Pass Inspector Report meter socket installation for utility connection (partial final) Inspected By: Donald Edel Email: don. edel.inspections@gmail.com Phone: (507) 210-8233 Date: 3/8/2022 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 I www.dli.mn.gov DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: Garage Remodel/ Lighting Permit Number: ELE2201-08084 Project location/address: 6188 Beach Rd, Oak Park Heights, Washington County, MN, 55082 Applicant: ONEILL ELECTRIC INC Phone: (651) 342-0906 Owner: American Home Remodeling Phone: (651) 342-0906 Inspection Type: Final Result: Pass with Conditions Inspector Report service and garage wiring (final) 200 amp M / 15 -circuits / 1 -feeder (the EMERGENCY DISCONNECT / SERVICE DISCONNECT need to be identified) (2 -ground rods need to be installed at the service) MN STATUTE32613.36, Correct the noted deficiencies. Return a signed copy of the Inspection Report to the inspector when the corrections are complete but no later than 14 days from the date of issuance unless otherwise instructed by the inspector. NEC 230.85, Each dwelling shall have an outdoor readily accessible emergency disconnect installed. The emergency disconnect could be a service disconnect for the dwelling or it could be a disconnect supplied by the serving utility. If the disconnect is the service disconnect, it must be labeled as the "EMERGENCY DISCONNECT- SERVICE DISCONNECT". If the disconnect is provided by the serving utility, and is not the service disconnect, the disconnect must be labeled "EMERGENCY DISCONNECT - NOT SERVICE EQUIPMENT". NEC 250.53, Unless a rod, pipe and plate electrode has a resistance to ground of 25 ohms or less, it shall be supplemented with another acceptable electrode other than an underground water pipe. Inspected By: Donald Edel Phone: (507) 210-8233 Email: don.edet.inspections@gmai1.com Date: 4/11/2022 443 Lafayette Road N., St. Paul, MN 55155 ( (651) 284-5005 1 www.dii.mn.gov