HomeMy WebLinkAboutBP 2021-00146 Electrical Permit & Inspection ReportsDEPARTMENT OF 443 Lafayette Road N., St. Paul, MN 55155
LABOR AND INDUSTRY (651) 284-5026, www.dii.mn.gov
Electrical Permit IP 22 )Zl _ I Wo
Permit Number: ELE2201-08084
Permit Information as of 01/31/22
Structure Type: One -Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued
Site County: Washington County Issued Date: 01/31/22
Site Address: 6188 Beach Rd, Oak Park Heights, MN 55082 Expiration Date: 01/31/23
Fees Paid: $71.00
Permit Applicant Information
ONEILL ELECTRIC INC Phone: (651) 342-0906
ONEILL ELECTRIC INC Mobile: (651) 342-0906
6143 OSGOOD AVE N, STILLWATER, MN 55082 Email: Cydnie@oneillelectricmn.com
Property Owner's Information
American Home Remodeling Phone: (651) 342.0906
6188 Beach Rd, Stillwater, MN 55082
Contracted Electrical Inspector's Information
Name: Donald Ede] Phone: (507) 210-8233
Don Edel Inspections LLC Email Address: mailto:
don.edel.insoections@amail.com
Project Information
Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com
Rough -In Inspection Required: Yes Number of Inspections Requested: 2
Project Description: Garage Remodel/ Lighting
NA
A rough -in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench
backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the
cost associated with uncovering and replacing the covering material.
The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized
and the space is occupied.
Print Date: 01/31/2022
DEPARTMENT OF
LABOR AND INDUSTRY
Inspection Report
Project Name: Garage Remodel/ Lighting Permit Number: ELE2201-08084
Project location/address: 6188 Beach Rd, Oak Park Heights, Washington County, MN, 55082
Applicant: ONEILL ELECTRIC INC Phone: (651) 342-0906
Owner: American Home Remodeling Phone: (651) 342-0906
Inspection Type: Rough -In Result: Pass
detached garage (rough -in)
Inspected By: Donald Ede[
Phone: (507) 210-8233
Inspector Report
Email: don.edel.inspections@gmail.com
Date: 2/15/2022
443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dli.mn.gov
DEPARTMENT OF
LABOR AND INDUSTRY
Inspection Report
Project Name: Garage Remodel/ Lighting Permit Number: ELE2201-08084
Project location/address: 6188 Beach Rd, Oak Park Heights, Washington County, MN, 55082
Applicant: ONEILL ELECTRIC INC Phone: (651) 342-0906
Owner: American Home Remodeling Phone: (651) 342-0906
Inspection Type: Partial Final Result: Pass
Inspector Report
meter socket installation for utility connection (partial final)
Inspected By: Donald Edel Email: don. edel.inspections@gmail.com
Phone: (507) 210-8233 Date: 3/8/2022
443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 I www.dli.mn.gov
DEPARTMENT OF
LABOR AND INDUSTRY
Inspection Report
Project Name: Garage Remodel/ Lighting Permit Number: ELE2201-08084
Project location/address: 6188 Beach Rd, Oak Park Heights, Washington County, MN, 55082
Applicant: ONEILL ELECTRIC INC Phone: (651) 342-0906
Owner: American Home Remodeling Phone: (651) 342-0906
Inspection Type: Final Result: Pass with Conditions
Inspector Report
service and garage wiring (final)
200 amp M / 15 -circuits / 1 -feeder
(the EMERGENCY DISCONNECT / SERVICE DISCONNECT need to be identified)
(2 -ground rods need to be installed at the service)
MN STATUTE32613.36, Correct the noted deficiencies. Return a signed copy of the Inspection
Report to the inspector when the corrections are complete but no later than 14 days from the
date of issuance unless otherwise instructed by the inspector.
NEC 230.85, Each dwelling shall have an outdoor readily accessible emergency disconnect
installed. The emergency disconnect could be a service disconnect for the dwelling or it could
be a disconnect supplied by the serving utility. If the disconnect is the service disconnect, it
must be labeled as the "EMERGENCY DISCONNECT- SERVICE DISCONNECT". If the disconnect is
provided by the serving utility, and is not the service disconnect, the disconnect must be
labeled "EMERGENCY DISCONNECT - NOT SERVICE EQUIPMENT".
NEC 250.53, Unless a rod, pipe and plate electrode has a resistance to ground of 25 ohms or
less, it shall be supplemented with another acceptable electrode other than an underground
water pipe.
Inspected By: Donald Edel
Phone: (507) 210-8233
Email: don.edet.inspections@gmai1.com
Date: 4/11/2022
443 Lafayette Road N., St. Paul, MN 55155 ( (651) 284-5005 1 www.dii.mn.gov