HomeMy WebLinkAbout2022-07-27 Applicant Response to 07-20-22 TPC Ltr 1r: ;;;N Letter of Transmittal 7096 EAST FISH LAKE RD. MAPLE GROVE, MN 55311 Date: 7/27/2022 To: City of Oak Park Heights Project: St.Croix Car Wash 14168 Oak Park Blvd. N 14493 60th Street N. Oak Park Heights, MN 55082 Oak Park Heights, MN 55082 We are sending for your review: x Documents Finish Sample Board x Application Thumb Drive x Plans 1 Landscape plan 1 7/27/2022 2 Signage plan 1 7/27/2022 3 Lighting plan 1 7/27/2022 4 Drainage calculations 1 5a Al - 3D drawings 1 7/18/2022 5b A2 - Elevations 1 7/18/2022 6 Vacuum details 1 7 Mailing labels 1 8 Development Application - revision with variance request 1 7/27/2022 cc Judd Andrews, Owner DUAN CORPORATION Jay Andrews, Owner Tim Krings, Lift Bridge Builders Frank Duan, Duan Corporation Amanda Berndt . , . r t A. DATE: I LOCATION: \�•j design.performance.technology TYPE: I PROJECT:110 j/ L%MI&' CATALOG#: VIPER Area/Site EbPTICS VIPER LUMINAIRE MIG 1R-43-STRIKE I STRSTRIKE FEATURES • Low profile LED area/site luminaire with a variety of IES distributions for lighting ,..,„.., F applications such as auto dealership,retail,commercial,and campus parking lots f'. � ""-- t • Featuring two different optical technologies,Strike and Micro Strike Optics, which provide the best distribution patterns for retrofit or new construction • Rated for high vibration applications including bridges and overpasses.All sizes are ,..,.:‘. rated for 1.5G • Control options including photo control,occupancy sensing,NX Distributed Intelligence"',wiSCAPE and 7-Pin with networked controls • New customizable lumen output feature allows for the wattage and lumen output to be customized in the factory to meet whatever specification requirements may entail • Field interchangeable mounting provides additional flexibility after the fixture has shipped t BUY _. _... AMERICAN C 0 us 1P65 SOLUTIO* OL*NS see Cert�cati°n speciti atians CONTROL TECHNOLOGY DISTBTED •d1 INTELRLIGENCEEa WISCAPE SPECIFICATIONS CONSTRUCTION INSTALLATION(CONTINUED) CONTROLS(CONTINUED) • Die-cast housing with hidden vertical heat • Knuckle arm fitter option available for 2-3/8" • NX Distributed Intelligence'available with fins are optimal for heat dissipation while OD tenon in fixture wireless control module,features keeping a clean smooth outer surface dimming and occupancy sensor • For products with EPA less than 1 mounted to • wiSCAPE®available with in fixture wireless • Corrosion resistant,die-cast aluminum housing a pole greater that 20ft,a vibration damper • control module,features dimming and with 1000 hour powder coat paint finish is recommended g occupancy sensor. Also available in 7-pin • External hardware is corrosion resistant ELECTRICAL configuration OPTICS • Universal 120-277 VAC or 347-480 VAC input CERTIFICATIONS • Micro Strike Optics(160,320,480,or voltage,50/60 Hz • Meets the qualifications for DLC Premium 720 LED counts)maximize uniformity in • Ambient operating temperature-40°C to 40°C • Listed to UL1598 and CSA C22.2#250.0- applications and come standard with mid- • Drivers have than 90%power factor 24 for wet locations and 40°C ambient power LEDs which evenly illuminate the entire and less than greater THD temperatures luminous surface area to provide a low glare • 1.5 G rated for ANSI C136.31 hi h vibration appearance.Catalog logic found on page 2 • LED drivers have output power over-voltage, applications g • Strike Optics(36,72,108,or 162 LED counts) over-current protection and short circuit provide best in class distributions and protection with auto recovery • Fixture is IP65 rated maximum pole spacing in new applications • Field replaceable surge protection device • Meets IDA recommendations using 3K CCT with high powered LEDs. Strike optics are provides 20kA protection meeting ANSI/ configuration at 0 degrees of tilt held in place with a polycarbonate bezel to IEEE C62.41.2 Category C High and Surge • This product qualifies as a"designated mimic the appearance of the Micro Strike Location Category C3;Automatically takes country construction material"per FAR Optics so both solutions can be combined fixture off-line for protection when device is 52.225-11 Buy American-Construction on the same application.Catalog logic found compromised Materials under Trade Agreements effective on page 3 04/23/2020.See Buy American Solutions. • Both optics maximize target zone illumination CONTROLS • Photo control,occupancy sensor programmable WARRANTY with minimal losses at the house-side, controls,and Zigbee wireless controls • 5 year warranty reducing light trespass issues. Additional available for complete on/off and dimming • See HLI Commercial and Industrial Outdoor backlight control shields and house side control shields can be added for further reduction of Lighting Warranty for additional information illumination behind the pole • Please consult brand or sales representative when combining control and electrical options • One-piece silicone gasket ensures a as some combinations may not operate as weatherproof seal anticipated depending on your application • Zero up-light at 0 degrees of tilt • 7-pin ANSI C136.41-2013 photocontrol receptacle option available for twist lock • Field rotatable optics photocontrols or wireless control modules INSTALLATION (control accessories sold separately) • Mounting patterns for each arm can be • 0-10V Dimming Drivers are standard and KEY DATA found on page 11 dimming leads are extended out of the Lumen Range 5,000-80,000 luminaire unless control options require • Optional universal mounting block for ease connection to the dimming leads.Must Wattage Range 36-600 of installation during retrofit applications. specify if wiring leads are to be greater than . Available as an option(ASQU)or accessory the 6"standard Efficacy Range(LPW) 92-155 for square and round poles. • All mounting hardware included Weight lbs.(kg) 13.7-30.9(6.2-13.9) Page 1/13 Rev.01/12/22 ©2022 Beacon Products,a division of Hubbell Lighting.Inc.Specifications subject to change without notice. ( '-- i_.. •-' ueee�� -� HUBBELL BEA VIPER-S-SPEC 701 Millennium Boulevard•Greenville,SC 29607/Tel 864.678.1000/Website vnvw.beaconproducts.com ��_i� Lighting A. 1•: '- v./Au—, r4cow--. , re' , • -.... 4 9 • VwPLED Voltaire Architectural Wall Pack WilliamsG CATALOG 4: Op 5-11/16" ' —. 0 TYPE:. i< 16-3/4" .I VWPH Front View PROJECT: Weight:15 lbs FEATURES ORDERING EXAMPLE:VWP H - L30/740 - T3 - DBZ - SDGL - OPTIONS - DIM - UNV • Designed to illuminate sidewalks, entryways,perimeters or facades ORDERING INFO • Intended for use in both uplight and downlight applications SERIES TYPE LUMENS 1'1 CRI CCT DISTRIBUTION 121 • Savings of up to 80%energy compared to VWP H Horizontal L30 3,0001m 7 70 30 3000K T3 Type III HID systems V Vertical L60 6,0001m 40 4000K TFT Type forward throw • Blends seamlessly with a variety of 50 5000K architectural styles • Made Right Here®in the USA SPECIFICATIONS FINISH OPTIONS 131 SHIELDING • HOUSING—Die-cast aluminum enclosure. BLK Black(RAL#9004) SDGL Micro-prismatic tempered glass lens • THERMAL MANAGEMENT—Integral DBZ Dark bronze CGL Clear tempered glass lens die-cast aluminum heatsink and LED DBR Medium bronze assembly provide passive thermal GRAY Standard gray management.Rated-30°C to 40°C SLV Satin aluminum(RAL#9006) ambient operating temperature(-20°C WHT White(RAL#9003) to 40°C with EM/10WC;0°C to 39°C with EM/4W). • OPTICAL SYSTEM—Precision,injection- molded,refractive acrylic lensing OPTIONS CONTROL VOLTAGE produces standard IES distributions. EM/4W 4-watt integral emergency LED driver 141 DIM Dimming driver prewired for 120 120V • LED ASSEMBLY—ANSI 3000K,4000K,or SF Single fuse 151 0-10V controls 208 208V 5000K CCT,minimum 70 CRI LEDs. DF Double fuse 161 240 240V • LED DRIVER—0-10V dimming. PC Factory-installed button-style photocell 01 277 277V • ELECTRICAL—120-277,347,and 480 HSGX Empty housing extension used to match units with UNV 120-277V VAC input range;50-60Hz;power factor EM,OCC,or conduit entry options. 347 347V 1141 >.90;THD<20%at full load.FCC Class TP Tamper-resistant Torx head screws 181 480 480V 1751 A compliant 10kA/10kV surge protection standard.Quick-disconnect wiring CONDUIT ENTRY 151 provided.L70>50,000 hours per IES TM-21. CR Right side conduit entry[+°I • FINISH—Super durable polyester 11+1 powder coat bonded to phosphate-free, CL Left side conduit entry multi-stage pretreated metal,meets and CD Dual conduit entry exceeds AAMA 2604 specifications for outdoor durability. VWPH ONLY • MOUNTING—Surface mounts directly EM/10WC 10-watt emergency LED driver 17�1 over a 4"maximum outlet box.Must be OCCWS FSP-311-L_Factory-installed-occupancy sensor 1731 anchored to adequate structure that can safely support fixture weight(VWPH=15 ACCESSORIES lbs,VWPV=23 lbs). • LISTINGS— TPTX-25 TOOL Tamper-resistant tool for Torx head screws.1161 • cCSAus certified as luminaire suitable for wet locations. • IDA Dark-Sky approved(downlight applications only). • RoHS compliant • IP65 rated. • Title 24 compliant with NOTES OCCWS FSP-311-L_option. 1 Lumen output based on 3500 CCT.Actual lumens may vary 9 Fixtures require housing extension when specified with conduit • WARRANTY—5-year limited warranty,see +/-5%,see page 2 for FIXTURE PERFORMANCE DATA. entry.Increases fixture depth.Conduit entry provided with 1/2" hew.com/warranty. 2 Additional lumen package available,see options NPT tapered pipe thread and plug.Increases fixture height See page 2 for DISTRIBUTION DETAILS. Conduit fitting to be supplied by others.Left and right when 3 See page 3 for FINISH OPTIONS. viewed from behind fixture. 4120-277V only;VWPV includes housing extension,increases 10 Left and right when viewed from behind fixture. Ida fixture depth.See page 2 for FIXTURE DETAILS. " Left and right when viewed from behind fixture. _____ 5 120V,277V,or 347V only;must specify voltage t2 Low temperature,includes housing extension increases fixture 6 208V,240V,or 480V only;must specify voltage. depth;120-277V only;not available with CR and CD options.See 120V,208V,or 277V only;must specify voltage.Not available page 2 for FIXTURE DETAILS. when specified with OCCWS option.See page 3 for 13 Includes housing extension(increases fixture depth),must OPTIONS DETAILS.Right side when viewed from behind fixture. specify lens.See page 3 for OCCUPANCY SENSOR DETAILS. 8 Silver finish only.Safety screws providing added support to the t4 Includes stepdown transformer. lens are not tamper-resistant(lens is sealed to the fixture via 15 Includes stepdown transformer. adhesion).Requires a tamper-resistant tool,see Accessories. t6 Tamper-resistant tool must be ordered separately.Please specify quantity required per project. H.E.Williams,Inc. • Carthage,Missouri • www.hew.com • 417-358-4065 • Designed and Manufactured in the USA Wall Information contained herein is subject to change without notice. REV.0224/22.70490.LA Page 1 of 3 • 6 • VWMLED Voltaire Mini Architectural Wall Pack Williams 0 CATALOG#: 01 I TYPE: 4-5/8" )L—I� 1< 10-3/16" 3.1 VWMH Front view PROJECT: Weight:6.5 Lbs. FEATURES ORDERING EXAMPLE:VWM H - L20/740 - T3 - DBZ - SDGL - OPTIONS - DIM - UNV • Designed to illuminate sidewalks, entryways,perimeters or facades ORDERING INFO • Intended for use in both uplight and downlight applications SERIES TYPE DI LUMENS 171 CRI/CCT DISTRIBUTION 131 • Savings of up to 80%energy compared to VWM H Horizontal 70 CRI 70 CRI TL Lambertian distribution 151 HID systems V Vertical L17 1,700Im 141 730 3000K T3 Type 111161 • Blends seamlessly with a variety of L20 2,000lm 740 4000K architectural styles 80 CRI 750 5000K • Made Right Here®in the USA L10 1,000lm 80CRI L17 1,7001m 830 3000K SPECIFICATIONS 840 4000K • HOUSING—Die-cast aluminum enclosure. • THERMAL MANAGEMENT—Integral die- FINISH OPTIONS 17I SHIELDING cast aluminum heatsink and LED source provide passive thermal management. BLK Black(RAL#9004) SDGL Micro-prismatic tempered glass lens Rated ambient operating temperature DBZ Dark bronze CGL Clear tempered glass lens -30°C to 50°C(L10,L17),-30°C to 45°C DBR Medium bronze (L20). GRAY Standard gray • OPTICAL SYSTEM—General output SLV Satin aluminum(RAL#9006) provides full cutoff. WHT White(RAL#9003) • LED SOURCE—ANSI 3000K,4000K, or 5000K CCT;70 or 80 CRI LEDs.L20: circuit board design.110&L17:Chip on board. OPTIONS CONTROL VOLTAGE • LED DRIVER—0-1OV dimming. PC Button-style photocell 187 DIM Dimming driver prewired for 0-10V 120 120V • ELECTRICAL—120-277 VAC input range; SP10 10kA/1OkV surge protection low voltage applications 208 208V 50-60Hz;power factor>.90;THD<20% TP Tamper-resistant Torx head screws[91 277 277V at full load.FCC Class A compliant.Quick- UNV 120-277V disconnect wiring provided.Calculated L70 >50,000 hours per IES TM-21. • FINISH—Super durable polyester ACCESSORIES powder coat bonded to phosphate-free, TPTX-25 TOOL Tamper-resistant tool for Torx head screws.061 multi-stage pretreated metal,meets and exceeds AAMA 2604 specifications for outdoor durability. • MOUNTING—Surface mounts directly over a 4"maximum outlet box.Must be anchored to adequate structure that can safely support fixture weight(6.5 Lbs). • LISTINGS— • cCSAus certified as luminaire suitable for wet locations. • IDA Dark-Sky approved(downlight applications only). • RoHS compliant. • IP65 rated. • Title 24 compliant with PC option. • WARRANTY—5-year limited warranty,see hew.com/warranty. , ida NOTES 2 See page 3 for FIXTURE DETAILS. 8 Factory-installed.120V,208V,or 277V only;must specify Lumen output based on 5000 CCT.Actual lumens may vary voltage.See page 3 for FIXTURE DETAILS.Left side when +/-5%,see page 2 for FIXTURE PERFORMANCE DATA. viewed from behind fixture. 3 See page 2 for DISTRIBUTION DETAILS. 9 Silver finish only.Safety screws providing added support to the eAvailable with 750 CRI/CCT only. lens are not tamper-resistant(lens is sealed to the fixture via L10&L17 only. adhesion).Requires a tamper-resistant tool,see Accessories. 6 L20 only. to Tamper-resistant tool must be ordered separately.Please 7 See page 3 for FINISH OPTIONS. specify quantity required per project. H.E.Williams,Inc. • Carthage,Missouri • www.hew.com . 417-358-4065 • Designed and Manufactured in the USA Wall Mount Information contained herein is subject to change without notice. REV 04/28/22.70489.LA Page 1 of 3 Sound Power and Narrow Band Report Test Condition: JE Adams Unit 9235 Customer: JE Adams Volts 120 2 Motor Unit with Q6600-092T Motors. Date: 5/10/2019 Frequency 60 Hz Small Steel Dome Mtr Model Q6600-092T(2 mtrs) By:Jonathan Johnson Inlet In Room Open Nozzle Unit: 9235-2 Test Method:ASTM F1334 FFT Data(Sound Pressure) 100- Mir Loc t 80- G - cc 19 0-1 20 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 19000 15000 16000 17000 18000 19000 20000 Frequency[Hz] Sound Power dBA 1/3 Octave Band Sound Pressure(RAW)dBA 1/3 Octave Band Mit Location Center Freq Sound RSS Corr. Avg Sound Sound Power:dBA (Hz) Power: Factor Pressure 1 2 3 4 5 6 25 11.1 6.9 4.2 6.5 2.6 1.7 1.9 4.3 5.9 iso i 31.5 14.1 -5.0 19.1 20.3 16.6 16.9 22.6 17.0 17.3 12533 ' 1 40 21.8 4.4 17.4 16.1 18.2 12.8 18.9 19.9 14.6 10000ow ! i ! ( 50 31.0 3.7 27.3 15.4 29.2 29.3 15.9 28.5 28.5 ' ' 63 36.2 9.7 26.6 26.0 25.0 26.0 25.7 28.1 27.7 6300 6300 ' ' ' ' 80 37.8 7.7 30.1 23.1 31.2 25.8 24.3 31.2 34.2 4003 100 46.2 2.0 44.2 44.0 43.7 43.4 43.4 43.9 46.2 31506.1 .(.. "1 ' ' ! 125 60.0 5.4 54.6 55.3 55.2 54.8 52.7 54.2 55.0 2300 160 64.7 2.2 62.5 62.5 60.3 62.4 63.9 61.4 63.7 1600 ' ' 200 64.7 0.8 63.9 63.3 64.6 62.7 65.6 62.4 63.8 F.--, 1.730 ' ' 250 623 1.1 61.2 62.6 59.8 59.2 61.2 61.1 62.2 2 1000 .61mmisimmimmelmomI 315 77.9 0.6 77.3 80.1 75.5 71.6 72.9 77.9 79.4 Y 800 i i 400 66.6 0.3 66.3 66.6 67.0 65.4 66.2 66.4 66.2 w 630 i I 1 j 500 68.8 1.7 67.1 68.1 66.0 66.9 68.1 67.1 66.0 500 E3, 400 I 630 72.9 1.3 71.7 71.9 70.7 72.3 72.7 71.4 70.4 If 315 ' ' ' 800 76.0 0.4 75.5 74.7 75.5 76.6 75.4 76.2 74.6 250 181111.1 ! 1000 78.0 0.3 77.7 78.0 77.9 77.6 77.4 77.9 77.4 200 : 01 1250 80.7 1.2 79.4 80.9 79.5 78.8 79.8 78.4 78.5 IIIIIIIIMII 125 1600 82.2 1.5 80.8 81.7 803 80.4 813 80.7 80.0 130 '11111811811111.118 I 2000 86.0 1.2 84.8 85.3 85.2 84.5 85.1 84.8 83.5 80 ' 2500 86.5 23 84.2 84.2 83.7 83.5 84.6 84.0 84.8 j 3150 85.4 2.7 82.7 82.6 82.8 82.4 82.3 833 82.9 so ao 4000 85.7 2.7 83.0 83.4 82.8 83.0 83.2 83.0 82.7 MMI 31.5 I I 5000 83.8 3.6 80.2 80.3 80.3 80.2 79.9 79.9 80.4 25 MN I jj i 6300 83.1 4.7 78.5 78.1 78.6 78.5 78.1 78.8 78.5 0.0 20.0 40.0 60.0 80.0 100.0 8000 81.4 6.4 75.0 75.1 75.3 74.9 74.8 75.0 75.0 SOUND POWER A-WEIGHT DB 10000 76.8 7.5 69.4 69.7 69.7 693 69.0 68.9 69.4 12500 72.2 9.8 62.4 62.5 62.9 61.8 61.7 62.5 62.9 ■Sound PowerdBA 16000 68.3 13.2 55.1 54.4 55.3 55.3 55.3 55.2 553 20000 63.7 17.7 46.1 45.4 46.1 46.6 46.1 46.0 46.1 Overall Sound Power dBA: 94.3 (Sound Power=Total Sound Pressure+Reference Sound Source(RSS)Correction Factor) Page 1 of 2 1:„-. '' E CTS a Sound Power and Narrow Band Report MI MC/FOR Test Condition: JE Adams Unit 9235 Customer: JE Adams Volts 120 2 Motor Unit with Q6600-092T Motors. Date: 5/10/2019 Frequency 60 Hz Small Steel Dome Mtr Model Q66OO-092T(2 mtrs) By:Jonathan Johnson Inlet In Room Open Nozzle Unit: 9235-2 Test Method:ASTM F1334 Sound Pressure At Distances From Unit (Sound Treated as Point Source) 1P Q T r= LP=LW+10 log (47tr2) Lp=Sound Pressure dBA Lw=Sound Power Q=Directivity Factor ` r=Distance from Source Sound Power=94.3 Half Sphere Q=2 Quarter Sphere Q=4 Distance Distance Feet Meters Sound Pressure(dBA) Feet Meters Sound Pressure(dBA) 5 1.5 82.7 5 1.5 85.7 10 3.0 76.7 10 3.0 79.7 15 4.6 73.1 15 4.6 76.2 25 7.6 68.7 25 7.6 71.7 30 9.1 67.1 30 9.1 70.1 35 10.7 65.8 35 10.7 68.8 40 12.2 64.6 40 12.2 67.6 45 13.7 63.6 45 13.7 66.6 50 15.2 62.7 50 15.2 65.7 55 16.8 61.9 55 16.8 64.9 60 18.3 61.1 60 18.3 64.1 75 22.9 59.2 75 22.9 62.2 80 24.4 58.6 80 24.4 61.6 85 25.9 58.1 85 25.9 61.1 90 27.4 57.6 90 27.4 60.6 95 29.0 57.1 95 29.0 60.1 100 30.5 56.7 100 30.5 59.7 Page 2 of 2 f; ELECT Sound Power and Narrow Band Report MOTOR Test Condition: JE Adams Unit 9235 Customer: JE Adams Volts 120 2 Motor Unit with Q6600-092T Motors. Date: 5/10/2019 Frequency 60 Hz Small Steel Dome Mtr Model Q6600-092T(2 mtrs) By:Jonathan Johnson Inlet In Room Fully Blocked Nozzle Unit: 9235-2 Test Method:ASTM F1334 FFF Data(Sound Pressure) We Loc1 100- 80- m 40- ,...,.v .....,.. 20- - .. 0-, 20 1000 2000 3000 4000 5000 6000 7000 8030 9000 10000 11000 12000 13000 14000 15000 16400 17000 18000 19000 20000 Frequency IHz] Sound Power dBA 1/3 Octave Band Sound Pressure(RAW)dBA 1/3 Octave Band Mic Location Center Freq Sound 855 Corr. Avg Sound Sound Power:dBA (Hz) Power: Factor Pressure 1 2 3 4 5 6 25 8.2 6.9 1.4 1.8 1.5 0.2 4.5 -0.7 -2.7 16000 ' ( 31.5 12.6 -5.0 17.6 20.6 13.5 17.0 20.6 15.6 8.3 12500 ' 40 19.4 4.4 14.9 16.6 15.9 14.6 14.6 13.3 13.6 wow i 50 28.9 3.7 25.2 13.8 25.2 27.9 17.4 25.3 28.0 8000 i 6300 { 63 37.1 9.7 27.4 26.6 27.0 27.9 27.0 26.0 29.2 5000 80 35.6 7.7 27.9 24.9 29.0 28.7 23.8 28.5 29.6 4ao0I 100 45.8 2.0 43.8 413 40.2 42.9 43.1 44.9 46.8 3150 ' ' I 125 57.7 5.4 52.3 53.1 52.5 49.6 52.9 53.3 51.4 2500 i 160 64.1 2.2 61.9 61.0 60.5 64.0 62.5 60.3 61.6 2000 200 63.0 0.8 62.2 60.7 61.0 64.8 62.6 62.4 59.6 T3 1600 1250 r 250 60.3 1.1 59.2 58.9 58.4 58.9 58.1 59.4 60.8 a wooi 315 78.3 0.6 77.7 79.8 76.7 80.5 74.8 78.1 683 800 400 71.8 0.3 71.6 72.2 70.6 72.7 71.2 72.1 69.9 Y z 630 , , , I 500 77.8 1.7 76.1 76.6 77.3 76.7 76.0 75.3 74.2 500 630 76.3 1.3 75.0 75.1 763 76.0 74.6 73.7 73.2 g 400 LL 315 ; i 800 83.0 0.4 82.6 81.8 83.6 83.6 82.1 82.9 81.1 250 i n I 1000 84.0 0.3 83.7 83.4 83.6 83.6 83.9 84.1 83.6 200 1250 86.2 1.2 84.9 85.2 86.0 84.0 85.6 84.5 83.8 izs 1600 88.2 1.5 86.7 87.2 87.0 85.9 87.1 87.0 86.0 100 I 2000 89.1 1.2 87.9 88.3 88.1 87,3 883 87.7 87.8 80 p=NM I 2500 88.6 2.3 86.3 86.5 86.5 86.2 86.2 86.0 86.1 63 INIMINBII 63 3150 89.1 2.7 86.4 86.4 86.4 86.3 86:4 85.9 86.7 40 { 1 4000 88.9 2.7 86.2 86.2 863 85.9 86.2 86.2 86.1 31.5 ' I I 5000 89.1 3.6 85.5 85.5 85.9 85.3 85.4 85.7 85.3 I 6300 89.2 4.7 84.5 83.9 84.4 84.8 84.4 85.0 84.5 0.0 20.0 40.0 60.0 80.0 100.0 8000 86.7 6.4 80.4 79.7 80.1 80.2 80.5 81.3 80.2 SOUND POWERA-WEIGHT DB 10000 82.6 7.5 75.1 74.0 75.2 75.1 75.0 76.3 74.9 12500 80.2 9.8 70.4 68.8 70.8 703 70.6 71.1 70.4 or sound Power:dBA 16000 78.8 13.2 65.6 62.3 65.2 65.6 65.9 68.1 64.3 20000 75.9 17.7 58.3 54.6 58.1 58.2 58.4 61.1 56.5 Overall Sound Power dBA: 98.7 (Sound Power=Total Sound Pressure+Reference Sound Source(855)Correction Factor) Page 1 of 2 a CTRO 1.7 .7 Sound Power and Narrow Band Report MMOTOR Test Condition: JE Adams Unit 9235 Customer: JE Adams Volts 120 2 Motor Unit with Q6600-092T Motors. Date: 5/10/2019 Frequency 60 Hz Small Steel Dome Mtr Model Q6600-092T(2 mtrs) By:Jonathan Johnson Inlet In Room Fully Blocked Nozzle Unit: 9235-2 Test Method:ASTM F1334 Sound Pressure At Distances From Unit (Sound Treated as Point Source) L Q �h r P Lp=Lw+101og 2 �47rra 1 Lp=SoundPressuredBA Lw=Sound Power a Q;Directivity Factor r=Distance from Source r i Sound Power=98.7 Half Sphere Q.2 Quarter Sphere Q=4 Distance Distance Feet Meters Sound Pressure(dBA) Feet Meters Sound Pressure(dBA) 5 1.5 87.0 5 1.5 90.0 10 3.0 81.0 10 3.0 84.0 15 4.6 77.5 15 4.6 80.5 25 7.6 73.1 25 7.6 76.1 30 9.1 71.5 30 9.1 74.5 35 10.7 70.1 35 10.7 73.1 40 12.2 69.0 40 12.2 72.0 45 13.7 67.9 45 13.7 71.0 50 15.2 67.0 50 15.2 70.0 55 16.8 66.2 55 16.8 69.2 60 18.3 65.4 60 18.3 68.5 75 22.9 63.5 75 22.9 66.5 80 24.4 62.9 80 24.4 66.0 85 25.9 62.4 85 25.9 65.4 90 27.4 61.9 _ 90 27.4 64.9 95 29.0 61.5 95 29.0 64.5 100 30.5 61.0 100 30.5 64.0 Page 2 of 2