HomeMy WebLinkAboutBP 2021-00136 - Electrical Permit & Inspections M1DEPARTMENT OF ;1;. v,i1 LABOR AND INDUSTRY7rA• ° - Inspection Report - 221 - Project Name: PANEL REPLACEMENT Permit Number: ELE2105-09334 Project location/address: 14250 55th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: SUNSHINE ELECTRIC LLC Phone: (651) 442-1147 Owner: SCOTT ANDERSON Phone: (651) 442-1147 Inspection Type: Final Result: Corrections Required Inspector Report replace service panel and add recessed lighting and receptacles in basement (final) 2-new circuits (final) **basement receptacles are required to be tamper resistant / GFCI AND AFCI protected **the altered switch must be replaced with an uncompromised switch plate. **the service has been upgraded from a 100 amp service to a 200 amp service, therefore requiring an emergency disconnect to be installed. (if the "emergency disconnect" is also the "service disconnect", then the service panel will need to be converted to a sub-panel) MN Rules 3801.3620, All electrical equipment, including luminaires, devices and appliances used as part of or in connection with an electrical installation shall be listed and labeled by a Nationally Recognized Testing Laboratory (NRTL) as having been tested and found suitable for a specific purpose. NEC 210.8(A) and 406.4 The ground-fault circuit-interrupter shall be installed in a readily accessible location. Ground-fault circuit-interrupter (GFCI) protection shall be provided for all 125-volt through 250-volt, receptacle outlets installed outdoors, indoor damp and wet locations, in boathouses, crawl spaces, basements, laundry areas, garages, accessory buildings, bathrooms, at kitchen countertops and within 6-feet of the top inside edge of all sink bowls, and within 6-feet from the outside edge of bathtubs and shower stalls. GFCI protection shall be provided for all lighting outlets installed in crawl spaces. NEC 210.12, All branch circuits supplying 125-volt, 15- and 20-amp outlets or devices in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, laundry areas, closets, hallways or similar areas shall be protected by a listed combination-type AFCI device. AFCI protection is also required where branch circuit wiring in the above locations is modified, replaced or extended. MN STATUTE 3266.37, There will be a charge of $35.00 for an extra inspection required to be paid before the next inspection. 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 www.dli.mn.gov nil DEPARTMENT OF .rr0 frA' LABOR AND INDUSTRY fr � Inspection Report ° ` -F NEC 110.3, Listed electrical equipment shall be installed and used in accordance with the listing requirements and the manufacturer's installation instructions. NEC 406.4 &t 406.12, All 125- and 250-volt, 15- and 20-amp receptacles installed or replaced in dwelling units shall be listed as tamper-resistant (TR). NEC 230.67, A dwelling electrical service must be protected by a Type 1 or Type 2 surge protective device. NEC 230.85, Each dwelling shall have an outdoor readily accessible emergency disconnect installed. The emergency disconnect could be a service disconnect for the dwelling or it could be a disconnect supplied by the serving utility. If the disconnect is the service disconnect, it must be labeled as the "EMERGENCY DISCONNECT- SERVICE DISCONNECT". If the disconnect is provided by the serving utility, and is not the service disconnect, the disconnect must be labeled "EMERGENCY DISCONNECT - NOT SERVICE EQUIPMENT". Inspected By: Donald Edel Email: don.edel.inspections@gmail.com Phone: (507) 210-8233 Date: 6/1/2021 443 Lafayette Road N., St. Paul, MN 55155 (651)284-5005 I www.dli.mn.gov MIDEPARTMENT OF D� D LABOR AND INDUSTRY ❑ i o•. Inspection Report Project Name: PANEL REPLACEMENT Permit Number: ELE2105-09334 Project location/address: 14250 55th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: SUNSHINE ELECTRIC LLC Phone: (651) 442-1147 Owner: SCOTT ANDERSON Phone: (651) 442-1147 Inspection Type: Final Result: Corrections Required Inspector Report 443 Lafayette Road N., St. Paul, MN 55155 (651) 284-5005 I www.dli.mn.gov mlDEPARTMENT OF LABOR AND INDUSTRY Inspection Report Inspection Failed. MN Rules 3801.3620, All electrical equipment, including luminaires, devices and appliances used as part of or in connection with an electrical installation shall be listed and labeled by a Nationally Recognized Testing Laboratory (NRTL) as having been tested and found suitable for a specific purpose. NEC 210.8(A) and 406.4 The ground-fault circuit-interrupter shall be installed in a readily accessible location. Ground-fault circuit-interrupter (GFCI) protection shall be provided for all 125-volt through 250-volt, receptacle outlets installed outdoors, indoor damp and wet locations, in boathouses, crawl spaces, basements, laundry areas, garages, accessory buildings, bathrooms, at kitchen countertops and within 6-feet of the top inside edge of all sink bowls, and within 6-feet from the outside edge of bathtubs and shower stalls. GFCI protection shall be provided for all lighting outlets installed in crawl spaces. NEC 210.12, All branch circuits supplying 125-volt, 15- and 20-amp outlets or devices in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, laundry areas, closets, hallways or similar areas shall be protected by a listed combination-type AFCI device. AFCI protection is also required where branch circuit wiring in the above locations is modified, replaced or extended. MN STATUTE 3266.37, There will be a charge of $35.00 for an extra inspection required to be paid before the next inspection. NEC 110.3, Listed electrical equipment shall be installed and used in accordance with the listing requirements and the manufacturers installation instructions. NEC 406.4 Et 406.12, All 125- and 250-volt, 15- and 20-amp receptacles installed or replaced in dwelling units shall be listed as tamper-resistant (TR). NEC 230.67, A dwelling electrical service must be protected by a Type 1 or Type 2 surge protective device. NEC 230.85, Each dwelling shall have an outdoor readily accessible emergency disconnect installed. The emergency disconnect could be a service disconnect for the dwelling or it could be a disconnect supplied by the serving utility. If the disconnect is the service disconnect, it must be labeled as the "EMERGENCY DISCONNECT- SERVICE DISCONNECT". If the disconnect is provided by the serving utility, and is not the service disconnect, the disconnect must be labeled "EMERGENCY DISCONNECT- NOT SERVICE EQUIPMENT". Inspected By: Donald Edel Email: don.edel.inspections®gmail.com Phone: (507) 210-8233 Date: 7/28/2021 443 Lafayette Road N., St. Paul, MN 55155 (651) 284-5005 www.dli.mn.gov rrilDEPARTMENT OF 443 Lafayette Road N.,St. Paul,MN 55155 LABOR AND INDUSTRY (651)284-5026,www.dli.mn.gov Electrical Permit Permit Number: ELE2105-09334 Permit Information as of 05/25/21 Structure Type:One-Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued Site County: Washington County Issued Date: 05/25/21 Site Address: 14250 55th St N, Oak Park Heights, MN 55082 Expiration Date: 05/25/22 Site Contact: SUNSHINE ELECTRIC Phone: Fees Paid:$136.00 Permit Applicant Information SUNSHINE ELECTRIC LLC Phone: (612)221-3896 SUNSHINE ELECTRIC LLC Mobile: (651)442-1147 PO BOX 17348, MINNEAPOLIS, MN 55417 Email: sunshine.elect@gmail.com Property Owner's Information SCOTT ANDERSON Phone: (651)442-1147 SCOTT ANDERSON Mobile: (612) 221-3896 14250 55TH ST N, STILLWATER, MN55082 Email: sunshine.elect®gmaiLcom Contracted Electrical Inspector's Information Name:Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Addres: mailto: don.edel.inspections@gmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough-In Inspection Required: No Number of Inspections Requested: 1 Project Description: PANEL REPLACEMENT PANEL REPLACEMENT A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 05/25/2021 mlDEPARTMENT OF 443 Lafayette Road N.,St. Paul,MN 55155 LABOR AND INDUSTRY (651)284-5026,www.dli.mn.gov Electrical Permit Permit Number: ELE2111-01199 Permit Information as of 11/03/21 Structure Type: One-Family Dwelling I Existing Dwelling or Other Items Permit Status: Issued Site County: Washington County Issued Date: 11/03/21 Site Address: 14250 55th St N, Oak Park Heights, MN 55082 Expiration Date: 11/03/22 Fees Paid: $36.00 Job Reference: AND2103 Permit Applicant Information MERCURY ELECTRIC CORPORATION Phone: (651)464-1660 MERCURY ELECTRIC CORPORATION Mobile: (651)464-1660 10 N OAKS RD, VADNAIS HEIGHTS, MN 55127 Email: mercuryelectricmn@gmail.com Property Owners Information Scott Anderson Phone: (651)442-1147 14250 55th St. N., Stillwater, MN 55082 Contracted Electrical Inspectors Information Name:Donald Edel Phone: (507) 210-8233 Don Edel Inspections LIC Email Address: mailto: don.edel.inspections@gmail.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bctmn@xcelenergy.com Rough-In Inspection Required: No Number of Inspections Requested: 1 Project Description: replace meter Replace meter A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 11/03/2021 M1DEPARTMENT ABORAND INDUSTRY 67,2 ax IFS ,, Inspection Report ° F Project Name: replace meter Permit Number: ELE2111-01199 Project location/address: 14250 55th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: MERCURY ELECTRIC CORPORATION Phone: (651) 464-1660 Owner: Scott Anderson Phone: (651) 442-1147 Inspection Type: Final Result: Pass Inspector Report replace meter and add 200 amp disconnect / basement receptacles and plates (final) Inspected By: Donald Edel Email: don.edel.inspections@gmail.com Phone: (507) 210-8233 Date: 11/12/2021 443 Lafayette Road N., St. Paul, MN 55155 I(651)284-5005 I www.dli.mn.gov