HomeMy WebLinkAbout2023-03-02 Escape Fire Protection - Report of Inspection/Test • Report of Inspection/Test 1 wet 1 dry # * ESCAPE FIRE March 2, 2023 ` auxPROTECTION Property 4i' 3000 Centerville Rd Americinn Oak Park Heights r �'`' 6Little 51-771$874 MN 55117 lUa5 1305 60th St N Conducted by: Luke Heikkila Oak Park Heights, MN 55082 Inspection Ref: 36858 Gabrielle Justus (651)287-1047 Print Date: 3/3/2023 Signatures Inspector-Printed Inspector-Signature Date Completed I state that the information on this form is correct at the time and place of my inspection,and all equipment Luke Heikkila 3/2/23 tested at this time was left in operational condition upon completion of this inspection except as noted. Owner-Printed Owner-Signature Date Completed I acknowledge this report has been reviewed with me. ROShnI Patel Except as noted,there have been no changes to the 3/2/23 original approved system. System Off 11:30 Monitoring Company Monitoring Company Operator Alarm Panel/Code System On 02:00 SK Honeywell FCI 1800-2244 Central Station Test Yes Alarm,Trouble and Supervisory indication tested and verified with the central station? Owner Information Yes Is the building occupied? Yes Has the occupancy classification and hazard of contents remained the same since the last inspection 2 Yes Are all fire protection systems in service? Yes Has the system remained in service without modification since the last inspection? Yes Was the system free of actuations of devices or alarms since the last inspection? Water Based System Yes Gauges on wet pipe system in good condition and Yes Alarm devices free from physical damage? showing normal water supply pressure? Yes Hydraulic nameplate,if provided,securely attached to Yes Valve supervisory switches indicate movement? riser and legible? Fire Department Connection Yes Visible and accessible? Yes Couplings and swivels not damaged and rotate smoothly? Yes Plugs or caps in place and undamaged? Yes Gaskets in place and in good condition? Yes Identification sign(s)in place? Yes Check valve is not leaking? Yes Automatic drain valve in place and operating properly? NA Interior free of obstructions(if caps are not in place)? NA Valve clapper operational over its full range(if caps are not in place)? Pipe Yes In good condition? Yes Free of mechanical damage and not leaking? Yes No external corrosion? Yes Properly aligned 2 Yes No external loads? Yes Visible pipe hangers and seismic braces not damaged or loose? Yes Was an obstruction investigation conducted and the system flushed? Print Date: 3/3/2023 Page 1 of 4 Copyright 2002-2016 Life Safety Inspector,OnSite Software Report of Inspection/Testi ti, ry . Annual 1 wet 1 dry ESCAPE FIRE i� _,a PROTECTION March 2, 2023 \\*.:;':tire. h k Garuda.MN 5511] Property: Americinn Oak Park Heights651,x,-ear. Inspection Ref: 36858 Sprinklers Yes Sprinkler wrench with spare sprinklers? Yes Proper number and type of spare sprinklers? Yes Free of corrosion? Yes Free of obstructions to spray patterns? Yes Free of foreign materials including paint? Yes Free of physical damage? Yes Are all sprinklers in service dated 1920 or later? Yes Fast Response sprinklers in service for less than 20 years?If"no"test sample now and every 10 years. Yes Standard sprinklers less than 50 years old? If no test Yes If sprinklers have been replaced,were they proper sample now and every 10 years. replacements? NA Sprinklers and spray nozzles protecting commercial cooking equipment and ventilating systems replaced except for bulb-type which show no signs of grease buildup? Cold Weather Check Yes Adequate heat in areas with wet piping? Yes Interior of pipe in preaction and dry pipe systems which passes through freezers free of ice blockage? Yes Auxiliary drains drained in dry pipe,preaction and deluge systems prior to the onset of freezing weather? Dry Valve Yes Enclosures around dry-pipe,preaction or deluge valves Yes Gauges on dry,preaction and deluge systems in good maintaining a minimum of 40 deg F'? condition and showing normal air and water pressure? Yes Free from physical damage? Yes Trim valves in appropriate(open or closed)position? Yes No leakage from intermediate chamber? Yes Interior of dry pipe,preaction and deluge valves passed internal inspection(required every 5th year if resetable without opening)? Yes Priming water level correct? Yes Low air pressure signal passed test? Yes Quick opening devices passed test? Yes Automatic air maintenance devices on dry pipe and preaction systems passed test? Yes Dry pipe systems being maintained in dry condition? Yes Interior of dry pipe,preaction and deluge valves cleaned? Valve Interior Inspection 5 Year Inspection NA Alarm valves and their associated strainers,filters and No Check valves internally inspected and all parts operate restriction orifices passed internal inspection? properly,move freely and are in good condition? NA Strainers,filters,restricted orifices and diaphragm No Gauges checked against calibrated gauge or replaced chambers on dry pipe,preaction and deluge valves ? passed internal inspection? Air Compressor Inspection Master Force Manufacturer of compressor Model of compressor Size of compressor(HP) Compressor Description/Type Yes Compressor appears to be in working condition? Yes Compressor appears free of leaks? Yes Compressor and motor are free of vibration and Yes Guages appear Ok and show normal PSI unusual noies? Yes Oil appears clean with no burnt odor Yes Electrical connections Ok? Yes Inlet air filter clean? Yes Breaker in the ON Postion? Yes Belt is in good condition? Yes Tension on the belt is Ok? Yes Has condensate/water been drained from the tank NA Dryer/Separator Ok? and/or water separator? Flow Test Outlet Pressure(psi) Waterflow Results System Connection Flowed Alarms Actuate devices pass comparable to Size Static Resid Static test prior test MECH RM Main drain 2 63 55 63 NA NA Yes Print Date: 3/3/2023 Page 2 of 4 Copyright 2002-2016 Life Safety Inspector,OnSite Software Report of Inspection/Test A'' �fk ` '�' ESCAPE FIRE Annual 1 wet 1 dry �� PROTECTION March 2, 2023 ;'?....4,,,, !!�� 6000 Cenlende Rd V'r' � le Canada MN 55117 Property: Americinn Oak Park Heights \\ 651„18974 Inspection Ref: 36858 Flow Test Outlet Pressure(psi) Waterflow Results System Connection Flowed Alarms Actuate devices pass comparable to Size test prior test Static Resid Static ITV 1/2 Yes Yes Yes Flow Time-66 sec Auxiliary Drains System/Location Drain Aux Drain Drained? Water Flow Observed . Yes Valve Inspection List a TO Location/Description Qty Valve Type SizeSecured Q .N N 2 0 w (7)' inn Q w -../ Control Valve Chart/lnsp/Maint 1 Butterfly4 Supervised Yes Yes Yes Yes Control Valve Chart/Insp/Maint 1 OS&Y 4 Supervised Yes Yes Yes Yes Yes Dry Valve Trip Test- Dry Valve Size: 4 Year Q. 0D. No QOD Year. Make Model Serial no. Make Model Serial no. Central AG Time to Trip thru water Pressure Air Pressure Trip point Time water reached Alarm Operated test pipe air pressure test outlet No Q.O.D. sec 63 psi 42 psi 1 1 psi sec Comparable to previous tests? Low Air-20 Print Date: 3/3/2023 Page 3 of 4 Copyright 2002-2016 Life Safety Inspector,OnSite Software Report of Inspection/Test , 4 , Annual 1 wet 1 dry __ ` ESCAPE FIRE March 2, 2023 ,, PROTECTION Property: Americinn Oak Park Heights °r� `='� 651.771""`°'88°'A"'"' Canada 8874 Inspection Ref: 36858 Deficiency / Recommendations Summary These items were deficient and do not meet the requirements of the applicable code at the time of the inspection. Items marked Recommendation are not required by the applicable code but are opportunities to improve the Life Safety of the property. Valve Interior Inspection 5 Year Inspection N Check valves internally inspected and all parts operate properly,move freely and are in good condition? NFPA-25-2002 12.4.2.1 Valves shall be inspected internally every 5 years to verify that all components operate properly,move freely,and are in good condition. N Gauges checked against calibrated gauge or replaced? NFPA-25-2002 12.2.8.2 Gauges shall be replaced every 5 years or tested every 5 years by comparison with a calibrated gauge.Gauges not accurate to within 3 percent of the full scale shall be recalibrated or replaced. Print Date: 3/3/2023 Page 4 of 4 Copyright 2002-2016 Life Safety Inspector,OnSite Software