HomeMy WebLinkAbout2019-05-02 Nardini Fire Inspection Report - Xcel Substation 5701 St. Croix Trail N ro N Nardini FIRE EQUIPMENT www.nardinifire.com/sales@nardinifire.com St.Paul,MN ENGINEERED SYSTEM INSPECTION AND TESTING REPORT Work Site#: 24708 Service Order#: ST00117172 Name of Facility: XCEL SUBSTATION--ALLEN KING Installation/Service Report Date: 05/02/2019 Time In: 1200 AM ElTimeOut: 1400 AM Ei El Street: 5701 N ST CROIX TRAIL I I C 3 kJ"-CA.- )Th 1 ,-1-(...- PM ® PM City: OAK PARK State:: MN Zip: 56357 Last Maintenance Date: 2019-02-02 Installation 0 Quarterly 0 Authorized Contact: WEIBEL,HAROLD Last Maintained By: Nardini Fire Semi-Annual gi Phone: 9528874575 Annual 0 Suppression Type Panel Type Manufacturer of System: Pyro-Chem Manufacturer: Ansul Revision: Type of Agent: ABC Dry Chem Model: AutoPulse Z-10 Intelligent 0 Conventional El Chip#: System Location: Generator Electrical Disconnect Location: CKT#13 Hazard Description: Generator Manual Release Operable? Yes IN No Qty: ( 1 ) Alarms Operable? Yes © No 0 Abort Operable? Yes i No Qty: ( 0 ) Lockout Valve? Yes [] No [] N/A 0Bypass Switch Operable? Yes No Qty: ( I ) Odorizer? Yes 01 No ❑ N/A El Actuator Operable? Yes No ❑ Date: 5-2019 Type: ECH3 Time Delay? Yes ® No 0 N/A ❑ Auto Detection Operable? Ye s® No 0 Discharge Hose Date: Detection Type: Ion( ) Photo( ) Heat( I )Temps: 165 Optical( ) Aspirating( ) Other( ) Notification Type: Bells( ) Horns( ) Horn/Strobes( 2 ) Strobes( ) Other( ) Model: System Sensor Auxiliary Functions Relay Press Low High Tested Batteries Switch Volt Volt Shutdown Equipment 0 0 0 Igi Size Qty. Date(s) Shutdown Ventilation 0 0 0 ® 12v lah 2 5-2019 Shutdown Dampers 0 Eg 0 0 El Building/Local Alarm Tie-In ® 0 0 ❑ El Panel Transfer to Battery?Yes® No 0 Load Test: Good Charger Test: Good Type of Release: Single Zone( X) Cross Zoned( ) Counting Zone( ) Other( ) Discharge Delay- 0 Seconds Pneumatic/Electric Sequence of Operations: l'Alarm- H/S 2°d Alarm- Discharge- H/S Abort Delay- N/A Seconds ELECTRIC Perimeter Doors Sealed Yes® No 0 Ceiling Tiles Clipped Yes 0 No 0 N/A Warning Signs Yes® No 0 Hazard Changes Yes 0 No r_ N/A 0 Checked Hazards for Leaks Yes® No 0 Nozzles Cl.(8"dia.) Yes No 0 N/A 0 Is actuator on cylinder and strapped? Yes® No 0 Serial# N/A Comments: System tested good.Pressure lines tested and discharge hoses blown out. w Pfeifer,Z Jason ,—.--•'_-- `-'—_--" Nardini Fire Technician(s) Customer/Authorized Agent—Printed Name Customer/Authorized Agent-Signature 1 r4) N ar ini FIRE EQUIPMENT www.nardinifire.com/sales@nardinifire.com Tanks SERIAL NUMBER FILL WT. GROSS WT. ACT.WT./LL TEST DATE PSIG VALVE MODEL 1. ATM736254 35 7-2018 340 Pyro-Chem 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 3