HomeMy WebLinkAbout2023-08-01 CR - Deck Guard Repair f - City of Oak Park Heights 14168 Oak Park Blvd. N. Phone:651.439.4439 Oak Park Heights, MN 55082 Fax:651.439.0574 Direct Dial:651.351.1661 August 1, 2023 Anthony Gaebler & Sandra Severson 5665 Omaha Ave. N. Oak Park Heights, MN 55082 Re: Missing Deck Guard Rail—Safety Violation/Correction Request Dear Anthony&Sandra: Your upper-level deck is in violation of the Minnesota State Residential Code due to the lack of a guardrail at the exterior of the deck. This is a safety violation that requires immediate attention. 1). Use of the deck shall cease immediately; 2). The access to the deck from the door area shall be block to prohibit access and still allow your use of the stairway to grade below; and 3). A new Code compliant guardrail shall be installed to the deck as per MN Residential Code Section R312. A work permit is required. t ' # - Please contact me for the repair permit no later than 9 A+ � �` „� `. Friday, August 11, 2023. � < �. :� � -�� ° � 4 If you have any questions, please contact me immediately. I am happy to visit with you to discuss \= � the situation and what options you may have in mind. lati 1 5' = '- ' � s� �w� ,7444T4.4,4 Thank you for your prompt attention. �� Sincerely � � � i , PLANNING &CODE ENFORCEMENT � ' �!�- "� 'i l-� Jul' ultman Bu di g Official 14� Enclosure: R312 Guards and Window Fall Protection t ' # _ zy- Email:jhultman@cityofoakparkheights.com SECTION R312 GUARDS AND WINDOW FALL PROTECTION R312.1Guards. Guards shall be provided in accordance with Sections R312.1.1 through R312.1.4. R312.1.1Where required. Guards shall be located along the open sides of floors, stairs, ramps, and landings that are located more than 30 inches (762 mm) measured vertically to the floor or grade below. Insect screening shall not be considered as a guard. R312.1.2Height. Required guards at open-sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 inches (914 mm) in height as measured vertically above the adjacent walking surface or the line connecting the nosings. Exceptions: 1. 1.Guards on the open sides of stairs shall have a height of not less than 34 inches(864 mm)measured vertically from a line connecting the nosings. 2. 2.Where the top of the guard serves as a handrail on the open sides of stairs, the top of the guard shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm) as measured vertically from a line connecting the nosings. R312.1.3Opening limitations. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere 4 inches (102 mm) in diameter. Exceptions: 1. 1.The triangular openings at the open side of stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches (153 mm) in diameter. 2. 2.Guards on the open side of stairs shall not have openings that allow passage of a sphere 43/8 inches (111 mm) in diameter. R312.1.4Exterior plastic composite guards. Plastic composite exterior guards shall comply with the requirements of Section R317.4. R312.2Window fall protection. Window fall protection shall be provided in accordance with Sections R312.2.1 and R312.2.2. R312.2.1Window sills. In dwelling units,where the lowest part of the opening of an operable window is located more than 72 inches (1829 mm) above the finished grade or surface below, the lowest part of the window opening shall be a minimum of 36 inches (914 mm) above the finished floor of the room in which the window is located. Operable sections of windows shall not permit openings that allow passage of a 4-inch diameter(102 mm) sphere where such openings are located within 36 inches(914 mm) of the finished floor. Exceptions: 1. Windows with openings that will not allow a 4-inch-diameter(102 mm) sphere to pass through the opening when the window is in its largest opened position. 2. Openings that are provided with window fall prevention devices that comply with ASTM F2090. 3. Windows that are provided with window opening control devices that comply with Section R312.2.2. 4. Replacement windows. R312.2.2Window opening control devices. Window opening control devices shall comply with ASTM F2090. The window opening control device, after operation to release the control device allowing the window to fully open, shall not reduce the net clear opening area of the window unit to less than the area required by Section R310.2.1.