Loading...
HomeMy WebLinkAbout2023-12-23 Commercial Plumbing & Heating RBA Test Report 0Fore24428 Greenway Avenue tstjNt�FtitICSAI< st Lake, MN 55025 ag.a.nr,�..v n r.wr6 (651)464-2988 REGULATED BACKFLOW ASSEMBLY (RBA)TEST REPORT NAME OF BUILDING,OWNER/OCCUPANT CONTACT NAME AND PHONE NUMBER Goodwill ADDRESS CITY STATE ZIP CODE 5980 Krueger lane north Oak Park Heights Mn 55082 APPLICANT COMPANY NAME CONTRACTOR LICENSE# CONTACT NAME AND PHONE NUMBER Commercial Plumbing&Heating,Inc. PC643117 Melinda Wisgerhof ADDRESS CITY STATE ZIP CODE EMAIL 24428 Greenway Ave Forest Lake MN 55025 mwisgerhof@cpandh.com TESTER NAME TESTER CERTIFICATION# PHONE Clint Pream BF065696 651-464-2988 TEST EQUIPMENT MANUFACTURER TEST EQUIPMENT MODEL# TEST EQUIPMENT SERIAL# TESTING EQUIPMENT CALIBRATION DATE Mid-West 845 11150355 1/6/23 ..':'''''''' ''',-.1.65 si p TYPE OF WORK AND FEE INFORMATION(check one) Ilinstall I Itelocate ❑Remove[ (Replace and SN#of Replaced Device Rebuild-Z Test BACKFLOW ASSEMBLY DETAIL INFORMATION Type(check one):fr/lReduced Pressure Principal or Pressure Principal Fire Protection I Reduced Pressure Detector Fire Protection 1-1 Double Check Valve 1-1 Double Check Detector Fire Protection Fl Pressure Vacuum Breaker[ (Spill Resistant Pressure Vacuum Breaker Manufacturer:APOIIo Model#RPLF4A Serial#719812Size:11/2" (inches) System Servicedirrigation Location in bldg.Water main room Floor# Room# TEST RESULTS: ✓ Pass ElFail (COMPLETE APPLICABLE ASSEMBLY TYPE SECTION BELOW) Reduced Pressure Principal or Reduced Pressure Detector Fire Protection(RP) TEST RESULTS Check Valve#2 Shutoff Valve#2' Check Valve#1 Pressure Diffevential Relief Valve InitialClosed Tight n✓ Yes❑No Closed TightlYes[lo Closed Tight nYes allo 7 8 Opened 2.4 psid Test Pressure Drop Across Check Valve#1 psid Final Closed Tight nYes nNo Closed Tight❑Yesnlo Closed Tight❑1' nNo Opened psid Test Pressure Drop Across Check Valve#1 psid Double Check Valve or Double Check Detector Fire Protection(DC)-TEST RESULTS Check Valve#1 Check Valve#2 Shutoff Valve#2 Initial Test Closed Tight nYesFIN° psid Closed Tight❑Yes[1Vo psid Closed Tightf1n Yes I 1No Final Test n Closed Tight I IYesElE n nNo psid Closed Tight Eyes No psid Closed Tight 1 I Yes 1 I No Pressure Vacuum Breaker(PVB)or Spill Resistant Vacuum Breaker(SRVB)-TEST RESULTS Air Inlet Vck V hutoff 2 Initial Test Failed to Open YES NO Closed Tight II YES Closed Tight I YES I NO Opened at psid CNhO PressureYYDrop Across Final Test Opened at psid Closed Closed Tight I—YES ONO Pressure Drop Across Check Valve#1 Describe parts and repairs when needed: CERTIFICATION:I hereby certify the foregoing information provided by me e correct and that the tested device is functioning in compliance with State of Minnesota Plumbing Code,Chapter 4714. TESTER'S SIGNATURE: TEST DATE:12/27/2023