HomeMy WebLinkAbout2024-02-05 Fire Alarm Inspection & Testing Report Nardini -PAEoBpARyKE- R Nardini Fire Equipment 405 County Road E W Saint Paul MN 55126 (651)483-6631 Report Cover Page SERVICE DATE:2/5/2024 SERVICE TICKET:ST00324503 BUILDING STREET CITY STATE ZIP Americinn By Wyndham 13025 60TH Street N Oak Park MN 55082 Heights BUILDING CONTACT PHONE N/A 651-275-0980 ext 400 System Status: Pass Tag Color: Yellow Please see the attached reports. If there are any questions, please reach out to the above office. Download your Report at: https://customer.nardinifire.com Signed 2/5/2024 Signed 2/5/2024 Inspector: Mike Hexum Building Contact: N/A Title: Service Ticket No. :ST00324503 Date : 2/5/2024 A Company of- Frequency: Annual Nardini PYE•BARKER Service Ticket No. : ST00324503 FIRE EQUIPMENT FIRE &SAFETY Inspection Contract No. : 0001432678 PO No. : Equipment Location : Front entry Fire Alarm Inspection Property : Americinn By Wyndham Owner : Americinn By Wyndham Address : 13025 60TH Street N Address : 13025 60TH Street N City : Oak Park Heights City : Oak Park Heights State : MN State : MN Zip : 55082 Zip : 55082 Phone : 651-275-0980 ext 400 Phone : 651-275-0980 ext 400 FIRE ALARM INSPECTION SUMMARY Smoke Detector: 20 Horn / Strobe: 18 Pressure Switch: 1 Manual Pull Station: 6 Chime: 51 Heat Detector: 5 Strobe: 8 Waterflow Switch: 2 SYSTEM DETAILS Panel Condition Normal On Arrival? Yes Was sensitivity performed during this inspection? No Monitoring Company Silent Knight Operator N/A Time Placed On Test 10:31am Circuit Class B Software Revision 6.0 Panel Make Gamewell FCi Panel Model S3 Last Date Software Revised. 01/01/2023 SYSTEM POWER SUPPLY Primary Normal Volts 120 Control Panel Amps _ 2.75 Over Current Type Circuit Breaker Over Current Amps 20 Panel Location Panel PP-11 •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 2 of 9 Service Ticket No. :ST00324503 Breaker# 43 SYSTEM TEST AND INSPECTIONS Control Panel (FACP) Specify type of inspection Visual and Functional Sequence Of Operation Specify type of inspection Visual & Functional Interface Equipment Specify type of inspection Visual and Functional Lamps/Led Specify type of inspection Visual and Functional Fuses Specify type of inspection Visual Primary Power Supply Specify type of inspection Visual and Functional Trouble Signals Specify type of inspection Visual and Functional Disconnect Switches Specify type of inspection Visual and Functional Ground Fault Monitoring Specify type of inspection N/A Transiet Suppressors Specify type of inspection N/A Remote Annuciators Specify type of inspection N/A Door Holders Specify type of inspection N/A Heat Detectors Were heat detectors tested with heat? N/A FACP BATTERY TEST Battery#1 AH Rating (2) 12vdc 12Ah Battery#1 Type Sealed Lead-Acid EMERG. COMM. EQUIP I NOTIFICATION APP. System Performance **Visual Pass **Functional Pass Audible **Visual Pass •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 3 of 9 Service Ticket No. :ST00324503 **Functional Pass Visual **Visual Pass **Functional Pass Speakers **Visual N/A **Functional N/A Phone Set **Visual N/A **Functional N/A Phone Jack **Visual N/A **Functional N/A Off Hook Indicator **Visual N/A **Functional N/A Amplifiers **Visual N/A **Functional N/A Tone Generators **Visual N/A **Functional N/A Call In Signal **Visual N/A **Functional N/A Voice Clarity **Visual N/A **Functional N/A Fireman Phone **Visual N/A **Functional N/A Was dBA meter utilized? No MONITORING & NOTIFICATION On/off Premises Monitoring Monitoring Agency Phone# 9528810344 Account Number 1800-2244 Account Password 1800-2244 **Alarm Signal - Received? Pass **Alarm Restore- Received? Pass •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 4 of 9 Service Ticket No. :ST00324503 **Trouble Signal - Received? Pass **Trouble Restored- Received? Pass **Supervisory Signal - Received? Pass **Supervisory Restore- Received? Pass Notifications Of Testing Completion **Fire Alarm Panel Condition Normal On Departure? Yes WATERFLOW SWITCH - Location: Dry Sprinkler Waterflow Zone or Address M052 Switch Type Paddle Type Size (inches) 0 **Pass/Fail Pass WATERFLOW SWITCH #2 - Location:Wet Sprinkler Waterflow Zone or Address M060 Switch Type Paddle Type Size (inches) 0 • **Pass/Fail Pass BOOSTER NAC Location Electrical Room Behind Front Desk Manufacturer FCi Model # FC-5495 Battery Size (2) 12vdc 7Ah Battery Type Sealed Lead-Acid **Visual Condition Pass **Battery/Charger( Pass or Fail ) Pass •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 5 of 9 Service Ticket No. :ST00324503 DEVICE INSPECTION REPORT Total Inspected:109 Total Failed:0 Total Passed:109 Zone or Sensitivity Sensitivity Pass/ Device Location Comments Address Type Make Model Range Alarm Point Fail Lobby Smoke S002 Smoke Detector FCi ASD-PL Pass Lobby Smoke S003 Smoke Detector FCi ASD-PL Pass Lobby Smoke S004 Smoke Detector FCi ASD-PL Pass Lobby Smoke S005 Smoke Detector FCi ASD-PL Pass Conference Room S006 Smoke Detector FCi ASD-PL Pass Smoke 1st Floor Corridor S009 Smoke Detector FCi ASD-PL Pass Smoke 1st Floor Corridor S010 Smoke Detector FCi ASD-PL Pass Smoke 1st Floor Corridor S011 Smoke Detector FCi ASD-PL Pass Smoke 1st Floor Corridor S012 Smoke Detector FCi ASD-PL Pass Smoke 1st Floor Corridor S013 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S015 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S016 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S017 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S018 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S019 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S020 Smoke Detector FCi ASD-PL Pass Smoke 2nd Floor Corridor S021 Smoke Detector FCi ASD-PL Pass Smoke Laundry Chute Smoke S022 Smoke Detector FCi ASD-PL Pass 2nd Floor Lobby Smoke S024 Smoke Detector FCi ASD-PL Pass 1st Floor Corridor S040 Smoke Detector FCi ASD-PL Pass Smoke Main Laundry Heat S007 Heat Detector FCi ATD-RL Pass Electrical Room Heat S008 Heat Detector FCi ATD-RL Pass South Laundry Heat S014 Heat Detector FCi ATD-RL Pass 2nd Floor Electrical S023 Heat Detector FCi ATD-RL Pass Room Heat 2nd Floor Storage S025 Heat Detector FCi ATD-RL Pass Room Heat Main Entry Pull M030 Manual Pull Station FCi MS-2 Pass Front Desk Pull M031 Manual Pull Station FCi MS-2 Pass Main Laundry Pull M032 Manual Pull Station FCi MS-2 Pass South Pull M033 Manual Pull Station FCi MS-2 Pass •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 6 of 9 Service Ticket No. :ST00324503 2nd Floor Corridor Pull M026 Manual Pull Station FCi MS-2 Pass 2nd Floor Corridor Pull M027 Manual Pull Station FCi MS-2 Pass Dry System Low Air M050 Pressure Switch Pass Pool Area Horn/Strobe Pass Pool Area By Exit Door Horn/Strobe Pass Pool Area Restroom Strobe Pass Outside Hospitality Horn/Strobe Pass Room Hospitality Room Strobe Pass Restroom Hospitality Room Horn/Strobe Pass Restroom By Front Strobe Pass Desk By Main Entrance Horn/Strobe Pass By Vending Machines Horn/Strobe Pass Kitchen Storage By Strobe Pass Front Desk Laundry Room Behind Horn/Strobe Pass Front Desk By Room 105 Horn/Strobe Pass By Room 118 Horn/Strobe Pass By Room 129 Horn/Strobe Pass 1st Floor Guest Laundry Strobe Pass 1st Floor South Exit Horn/Strobe Pass By Room 229 Horn/Strobe Pass By Room 218 Horn/Strobe Pass By Room 206 Horn/Strobe Pass By Room 205 Horn/Strobe Pass In Room 105 Chime Pass In Room 106 Chime Pass In Room 108 Chime Pass In Room 107 Chime Pass In Room 109 Chime Pass In Room 110 Chime Pass In Room 112 Chime Pass In Room 111 Chime Pass In Room 113 Chime Pass In Room 114 Chime Pass In Room 116 Chime Pass In Room 115 Chime Pass In Room 117 Chime Pass In Room 118 Horn 1 Strobe Pass Room 118 Bathroom Strobe Pass In Room 120 Horn/Strobe Pass •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 7 of 9 Service Ticket No. :ST00324503 Room 120 Bathroom Strobe Pass In Room 119 Chime Pass In Room 121 Chime Pass In Room 122 Horn/Strobe Pass Room 122 Bathroom Strobe Pass In Room 124 Chime Pass In Room 123 Chime Pass In Room 125 Chime Pass In Room 126 Chime Pass In Room 128 Chime Pass In Room 127 Chime Pass In Room 129 Chime Pass In Room 229 Chime Pass In Room 227 Chime Pass In Room 228 Chime Pass In Room 226 Chime Pass In Room 225 Chime Pass In Room 223 Chime Pass In Room 224 Chime Pass In Room 222 Chime Pass In Room 221 Chime Pass In Room 219 Chime Pass In Room 220 Chime Pass In Room 218 Chime Pass In Room 217 Chime Pass In Room 215 Chime Pass In Room 216 Chime Pass In Room 214 Chime Pass In Room 213 Chime Pass In Room 211 Chime Pass In Room 212 Chime Pass In Room 210 Chime Pass In Room 209 Chime Pass In Room 207 Chime Pass In Room 208 Chime Pass In Room 206 Chime Pass In Room 205 Chime Pass In Room 204 Chime Pass In Room 204 Chime Pass In Room 203 Chime Pass In Room 202 Chime Pass •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 8 of 9 Service Ticket No. :ST00324503 SIGNATURE This report was reviewed with: Nardini Fire Equipment Print Name : N/A Technician : Mike Hexum Signature Z" / Signature • Date : 2/5/2024 Date : 2/5/2024 •405 County Road E W•Saint Paul MN•55126 Fire Alarm Inspection&Test Page 9 of 9