HomeMy WebLinkAboutBP 2024-432 Met Council SAC Determination - Croixview HoldingsMCES USE: Letter Reference: 23091463 Address ID: 764811 Payment ID: 470869 Date of Determination: 09/14/23 Greetings! Please see the determination below. Determination Expiration: 09/14/25 Project Name: Croixview Holdings Project Address: 5416 Stagecoach Trail North Suite #/Campus: N/A City Name: Oak Park Heights Applicant: Joan Klatt and Tim Siegfried, George Siegfried Construction Company Special Notes: None Charge Calculation: Mixed Use: 15,200 sq. ft. @ 3800 sq. ft. / SAC = 4.00 Total Charge: 4.00 Credit Calculation: None Total Credit: Net SAC: 4.00 - 4 SAC Due The business information was provided to MCES by the applicant at this time. It is the City's responsibility to substantiate the business use and size at the time of the final inspection. If there is a change in use or size, a redetermination will need to be made. If you have any questions email me at: sara,running@metc.state.mn.us. Thank you, Sara Running SAC Technician Please visit our SAC website by going to: http://www.metrocouncil.org/SACprogram 390 Robert Street North I St. Paul. rv1N 55101-1805 Phone 651.602.1000 1 Fax 651.602.1550 1 M' 651.291.0904 metrocouncil.org ' • • A,„ Eqyi Emplo�lcv .nw�r- • PLAN NOTES # NOTES } 6"METAL STUD WALL PATH SW GYP. BOARD EA. SIDE BUILT TO ROOF DECK IN FUTURE. WALL TO DIVIDE TENANT AND OWNER !SPACES 7 IDASHED. HALF -TONED LINEWORK INDICATES FUTURE TENANT EXPANSION. RDUGH41JPLlMTBING ONLY 3 (LOADING DOCK AREA RETAINING WALL/MiWOR1L TO E4'NT BELOW Fp81CH FLOOR FISYATp}t 197A",CC9RgIbLTE YBTIICARL7 ;STRUCTURAL FOR REQUIREMENTS, 4 RECEPTOWBT AREA ,f, VJIGFUL57ATM FURfattlIm 1 CABINETRY TO BE DESIGNED BY OIANER. i CONC RETE WALK S EE C ML 6 GOOLCclwVLLWT LOCNRORAIL 7 BOARD FORMED B" CONCRETE BEARING WALL L APPROX ROOF DRAIN LOCATION AND PROPOSED CONNECTION LOCATION TO UNDERGROUNDS A IROUGHSAWN TIMBER SILLS, WITH STEEL OR ALUMINUM JAMBS. VERIFY WITH OWNER NOTES NOTES FLOOR PLAN GENERAL NOTES 1. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 2. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE AND IN PROPERALIGNMENT, U.N.O. 3. ALL DIMENSIONS=TO FINISH CONSTRICTION, U.N.O. DIMENSIONS NOTED "HOLD" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN 3 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE DIMENSIONS NOTED "CLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE MAINTAINED WITHOUT EXCEPTION, DIMENSIONS MARKED i MEAN A VARIANCE NOT GREATER THAN I INCH, VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT, ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE FINISH FACE OF WALL BELOW SILL, U.N.O. 4 ALL GLASS SHALL BE CLEAR TEMPERED. GLAZING TONE MARKS SHALL NOT BE VISIBLE. CLEAN & POLISH ALL GLASS PRIORTO PROJECT DELIVERY. ALL PARTITIONS ARE TYPE 'A' LLMO. WHERE PARTITIONS ARE ATTACHED TO CURTAIN WALL, CENTER PARTITIONS ON WINDOW MULLIONS, PERPENDICIILARTO PERIMETER WAG., U.N.O. S. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS SHALL ACCOMMODATE FULL CONCEALMENT OF RECESSED CABINETS OR PARTIAL CONCEALMENT OF SEMI - RECESSED CABINETS AS SPECIFIED BY THE MANUFACTURER. 6. ALL PARTITIONS ABUTTING COLUMNS ARE TO ALIGN WITH THE FACE OF THECOLUMN, LIN.O. 7. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS, PROVIDE LEVEL 4 FINISH,U.N.O.- REFERTO MATERIAL SCHEDULE& FINISH PLAN FOR MATERIALS & LOCATIONS THAT REQUIRE A LEVEL 5 FINISH, U. N.O. B, ALL EXPOSED GYPSUM BOARD EDGES TO HAVE VINYL OR METAL EDGE TRIM. 9. REFER TO THE PARTITION TYPES FOR PARTITION THICKNESS I& ITI CONSTRUCTION OF FIRE -RATED PARTONS, INCLUDING TAPING AND FINISHING OF GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE, SHALL BE IN ACCORDANCE WITH UL SPEQRCATIONS TO ACHIEVE RATING INDICATED. 11. ACOUSTICAL (SOUND -ISOLATION) PARTITIONS SHALL BE SEALED FOR RILL HEIGHT TO PREVENT PASSAGE OF AIRBORNE SOUND. TAPE AND FINISH ALL GYPSUM WALLBOARD JOINTS AND FASTENERS(INCLUDING ABOVE SUSPENDED CEILING). CAULKAT PERIMETER AND SEAL AT ALL PENETRATIONS. 12. WHERE PARTITIONS EXTEND ONLYTO UNDERSIDE OF SUSPENDED CEILING, SECURE THE TOP TRACKTO THE EXPOSED CEILING GRID. PROVIDE A COMPRESSIBLE GASKET BETWEEN THETOPTRACK AND THE CEILING GRID, PROVIDE TAPABLE METAL 3-BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO JOINTS VARYING MORE THAN 1/6" OVER 6-0-- AND NO JOINTS GREATERTHAN 3/I6", UµO, CAULK PERIMETER AT TOP OF GW& 13. PROVIDE GROUNDS AND BLOOONGIN METAL STUD WALL FRAMING FOR SUPPORT OF CASEWORK SHELF -STANDARDS, A/V DEVICES, FURNITURE, ETC. COORDINATE BLOCKING REQUIREMENTS WITH RURNITURE & AV INSTALLERS SEE CONSrRUCUON PLANS FOR WALL -MOUNTED MARKFRBOARD, MONITORS & PROJECTION SCREENS; PROVIDE BLOCKING PER MANUFACTURERS REQUIREMENTS. 14. ALL HINGED DOORS TO BE 4" FROM NEAREST PERPENDICULAR PARTITION, U.N.O. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. ALL DOORS SHALL HAVE V-6` CLEAR ON THE STRUaVPULL SIDE OF DOOR AND 1'-0 CLEAR ON THE SrRIIWPUSH SIDE (IF THEY HAVE BOTH A LATCH AND A CLOSER) VWFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIORTO CLOSING OUT PARTITIONS 15. THE CONTRACTOR SHALL ESTABLISH A SINGLE FLOOR ELEVATION THAT IS TO BE USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS OF THE SAME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR SLAB OR FINISHED FLOOR THICKNESS. 16. PROVIDE DOUBLE STUDS AT DOOR JAMBS. 17. METAL SPUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAGE (MINIMUM) fA 16- O.C. (MAXIMUM). REFERTOTHE FINISH PLANS FORTILE LOCATIONS. IB. GYPSUM WLL ABOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING ROUGH -IN (E.G.BATHROOM% PANTRY, JANITORS CLOSET, WET COLUMNS) SHALL BE WATER- RESISTANT. 19. PROVIDE DIAGONAL BRACING TO SLAB AT DOUBLE STUDS AT DOOR OPENINGS 20. PROVIDE VERTICALCONTROL JOINTS 30'O.0 MAX. IN ALL GWB PARTITIONS LONGER THAN 30'. WHEN POSSIBLE CONTROL JOINTS SHOULD BE LOCATED ABOVE THE CORNER OF A DOOR STUDIO EA 76 Coulee Road Hudson, WI 54016 716.386.8303 WeAreStudioEA.com noN oaTaavon>PwismaaAaao 21123/17-07Wsav meson ev or 111—cra Nicholas NL Clever nuMeEa sews '^� v Z Z J_ Z J � H O 2 VON OWo 2 W W�LO X_ ga Cf) Y p (D Q �O V LID BID & PERMIT SET RELEASE DATE BID B_PERMIT SEL 202307-07 PROJECT NO. 22-596 OVERALL FLOOR PLAN MAIN LEVEL - OVERALL FLOOR PLAN 3/32" = T-0" A2.1