The following comments are in response to your plan review letter dated November 6, 2024 on the
above named project. Please see below for responses to the items included in your letter, which
have been reviewed by the design team and applicable consultants. Revisions that require updates
or modifications to the drawings will be incorporated for inclusion in the issued contract
documents.
1. Comment: Any mechanical equipment installed outside of the building shall be screened in
accordance with Section 401.15.E.10.e of the Zoning Ordinance.
Response: Per discussion with City of Oak Park Heights Planning and Code Enforcement, it is our
understanding that the only new exterior mechanical equipment, being an exhaust fan, will not require
screening due to its size and low profile compared to roof and wall elevations.
2. Comment: Any signage proposed for the site shall be in compliance with Section 401.15.G of
the Zoning Ordinance and will require a sign permit.
Response: Acknowledged. As part of the sign stadium improvements project, the District intends to
include school signage on the west side of the stadium press box (approximately 1,100 feet due east of
Stillwater Boulevard) that matches the existing sign on the east side of the press box, which is 3’-6”(h) x
36’-0”(w) (126sqft total). A signage permit will be obtained as noted. See attached drawing for analysis.
3. Comment: Any additional lighting proposed for the site shall be in compliance with Section
401.15.B.7 of the Zoning Ordinance.
Response: Acknowledged. No additional lighting on the High School building is being proposed.
Lighting on the press box is being replaced like for like.
Letter to Scott Richards
Page 2
4. Comment: Grading and drainage plans shall be subject to review by the City Engineer.
Response: Acknowledged; final grading and drainage plans will be submitted for review as required.
Sincerely,
Wold Architects and Engineers
John Kretchmer | AIA
Associate
Enclosure
cc: Jacob Rife, City of Oak Park Heights
Julie Hultman, City of Oak Park Heights
Mark Drommerhausen, Stillwater Area Public Schools
Anthony Willger, Stillwater Area Public Schools
Paul Aplikowski, Wold
Valerie Peterson, Wold
Alex Malnaa, Wold
TD/EDU-MN-ISD834/Stillwater HS/242077/_Admin/Letters/2024.11.25 Letter to Scott Richards
HOME OF THE PONIES PROPOSED SIGNAGE = 126sqft
PROPOSED PRESS BOX = 632sqft
9'
-
7
"
66'-0"
3'
-
6
"
36'-0"
STILLWATER AREA
HIGH SCHOOL
PRESS BOX
S TILL W A T E R B L V D
1,100ft
HOME
VISITOR
PR
E
S
S
B
O
X
WO
R
K
E
R
S
MEDIA 1
MEDIA 3
MEDIA 2
HO
M
E
O
F
T
H
E
P
O
N
I
E
S
*
P
O
N
Y
H
E
A
D
L
O
G
O
*
N
66
'
-
0
"
8'-6"
9'
-
7
"
66'-0"
3'
-
6
"
36'-0"
265'-0"
30
'
-
0
"
APPROXIMATE AREAS:
EXISTING GRAND STAND: 7,950SQFT
PROPOSED PRESS BOX = 632SQFT
PROPOSED SIGNAGE = 126SQFT
PROPOSED SIGN
PROPOSED PRESS BOX
EXISTING GRAND STAND
Autodesk Docs://242077 - Stillwater Area HS Admin Renovation/242077 - SAHS Main Office Addition and Renovation (R23).rvt
11/25/2024 10:42:26 AM
Independent School District #834
SAHS 2025 ADDITION AND RENOVATIONS
November 25, 2024
Comm No: 242077
PRESS BOX SIGN
PB1.0
0
3/16" = 1'-0"2 PROPOSED PRESS BOX SIGN - WEST ELEVATION
4' 8'
3 EXISTING PRESS BOX SIGN - EAST ELEVATION 4 PRESS BOX SITE PLAN 5 PRESS BOX PLAN
0
1/32" = 1'-0"1 EXISTING GRAND STAND & PROPOSED PRESS BOX
24' 48'