HomeMy WebLinkAbout2024-12-19 Commercial Plumbing & Heating RBA Test Report - Irrigation24428 Greenway Avenue Forest Lake, MN 55025 (651) 464-2988 REGULATED BACKFLOW ASSEMBLY (RBA) TEST REPORT APPLICANT COMPANY NAME ADDRESS TESTER NAME TEST EQUIPMENT MANUFACTURER STATE CONTRACTOR LICENSE # CITY CONTACT NAME AND PHONE NUMBER EMAIL ZIP CODE PHONE TESTER CERTIFICATION # TESTING EQUIPMENT CALIBRATION DATE TEST EQUIPMENT SERIAL# TEST EQUIPMENT MODEL# TYPE OF WORK AND FEE INFORMATION (check one) Install Relocate Remove Replace and SN# of Replaced Device Rebuild Test BACKFLOW ASSEMBLY DETAIL INFORMATION Type (check one): Reduced Pressure Principal or Pressure Principal Fire Protection Reduced Pressure Detector Fire Protection Double Check Valve Double Check Detector Fire Protection Pressure Vacuum Breaker Spill Resistant Pressure Vacuum Breaker Manufacturer: Model # Serial # Size: (inches) System Serviced Location in bldg. Floor # Room # NAME OF BUILDING, OWNER/OCCUPANT CONTACT NAME AND PHONE NUMBER ADDRESS CITY STATE ZIP CODE TEST RESULTS: Pass Fail (COMPLETE APPLICABLE ASSEMBLY TYPE SECTION BELOW) Reduced Pressure Principal or Reduced Pressure Detector Fire Protection (RP) – TEST RESULTS Pressure Differential Relief Valve Check Valve #1 Shutoff Valve #2 Check Valve #2 Final Test Initial Test Opened at psid Opened at psid Closed Tight Yes No Pressure Drop Across Check Valve #1 psid Closed Tight Yes No Pressure Drop Across Check Valve #1 psid Closed Tight Yes No Closed Tight Yes No Closed Tight Yes No Closed Tight Yes No Double Check Valve or Double Check Detector Fire Protection (DC) – TEST RESULTS Final Test Initial Test Closed Tight Yes No psid Check Valve #1 Closed Tight Yes No psid Closed Tight Yes No psid Closed Tight Yes No psid Shutoff Valve #2 Closed Tight Yes No Closed Tight Yes No Pressure Vacuum Breaker (PVB) or Spill Resistant Vacuum Breaker (SRVB) – TEST RESULTS Air Inlet Valve Check Valve #2 Check Valve Shutoff #2 Initial Test Final Test Failed to Open YES NO Opened at psid Closed Tight YES NO Closed Tight YES NO Closed Tight YES NO Pressure Drop Across Check Valve #1 Closed Tight YES NO Pressure Drop Across Check Valve #1 Opened at psid Describe parts and repairs when needed: CERTIFICATION: I hereby certify the foregoing information provided by me to be correct and that the tested device is functioning in compliance with State of Minnesota Plumbing Code, Chapter 4714. TESTER’S SIGNATURE: TEST DATE: Joel Parent BF066231 651-464-2988 Melinda WisgerhofCommercial Plumbing & Heating, Inc.PC643117 mwisgerhof@cpandh.com Midwest Instrument 845-5-11150354 24428 Greenway Ave Forest Lake MN 55025 Static _______ PSI 1/3/24 Goodwill 5890 Krueger Lane N Oak park Heights MN 55082 Apollo RPLF4A 719812 11/2" Irrigation 7.8 2.4 12/19/24