Loading...
HomeMy WebLinkAboutBP 2023-00355 Electric Permit & InspedtionsMDEPARTMENT OF LABOR AND INDUSTRY 443 Lafayette Road N., St. Paul, MN 55155 (651) 284-5026, www.dli.mn.gov Electrical Permit Permit Number: ELE2309-03418 Permit Information as of 09/12/23 Structure Type: One -Family Home I Existing Home or Other Items Permit Status: Issued Site County: Washington County Issued Date: 09/12/23 Site Address: 14825 57th St N, Oak Park Heights, MN 55082 Expiration Date: 09/11 /24 Fees Paid: $71.00 Permit Applicant Informat_i_on Mary Kay Badar Mobile: (214) 399-9684 14825 57th St N, Oak Park Heights, MN 55082 Email: marykaybadar@gmail.com Contracted Electrical Inspector's Information Name: Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Address: mailto: d on.ed el, i nsoecti onsOo mai I.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough -In Inspection Required: Yes Number of Inspections Requested: 2 Project Description: Basement Remodel finish basement with 2 bedrooms and a bathroom A rough -in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 09/12/2023 DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: Basement Remodel Permit Number: ELE2309-03418 Project location/address: 14825 57th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: Mary Kay Badar Inspection Type: Rough -In Phone: (214) 399-9684 Result: Pass with Conditions Inspector Report Basement remodel (rough in) (add another receptacle to meet code) (the cables must be strapped no less than 1-1 /4 inches from the nailing surface of the stud) MN STATUTE 326B.36, Correct the noted deficiencies. Return a signed copy of the Inspection Report to the inspector when the corrections are complete but no later than 14 days from the date of issuance unless otherwise instructed by the inspector. NEC 300.4, Cables and raceways shall be protected from damage. Where installed through holes in wood framing, the edge of the hole shall be not less than 1.25-inch from the nearest edge of the wood member or shall be protected by a 1 /16-inch steel plate. CAUTION: Refer to the Building Code for restrictions on boring, cutting, drilling, and notching of wood framing members NEC 210.52, Receptacle outlets in habitable rooms shall be installed so that no point measured horizontally along the floor line in any wall space is more than 6-feet from a receptacle outlet. A receptacle outlet shall be installed in each wall space 2-feet or more in width. Inspected By: Donald Ede[ Phone: (507) 210-8233 Email: don.edet.inspections@gmail.com Date: 9/25/2023 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dli.mn.gov DEPARTMENT OF LABOR AND INDUSTRY Inspection Report Project Name: Basement Remodel Permit Number: ELE2309-03418 Project location/address: 14825 57th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: Mary Kay Badar Phone: (214) 399-9684 Inspection Type: Rough -In Result: Pass with Conditions Inspector Report basement rough in 1.Owner to remove wire to hallway outlet from bathroom circuit and rewire it off family room or bedroom circuit. 2. The bedroom ceiling boxes need to be changed to fan rated boxes Inspected By: Randy Edel Email: randyedel59@gmail.com Phone: (507) 334-3748 Date: 4/2/2024 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dli.mn.gov DEPARTMENT OF 0 LABOR AND INDUSTRY Inspection Report Project Name: Basement Remodel Permit Number: ELE2309-03418 Project location/address: 14825 57th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: Mary Kay Badar Phone: (214) 399-9684 Inspection Type: Final Result: Pass with Conditions Inspector Report basement remodel (final) (need to correct one of the basement circuits that is not GFCI protected) (one receptacle has no power) Inspected By: Don Ede[ Phone: (612) 419-7129 Email: don.edel@state.mn.us Date: 1 /23/2025 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dli.mn.gov