Loading...
HomeMy WebLinkAbout2025-02-06 TPC Planning Report TPC3601 Thurston Avenue N, Suite 100 C •4f Anoka, MN 55303 Phone: 763.231.5840 Facsimile: 763.427.0520 TPC«PlanningCo.corn PLANNING REPORT TO: Jacob Rife FROM: Scott Richards DATE: February 6, 2025 RE: Oak Park Heights — Stagecoach Trail Condo Building — Conditional Use Permit for Parking — 5845 Stagecoach Trail North TPC FILE: 236.02 — 24.05 BACKGROUND CJ Randazzo of JACC Capital Holdings, LLC has made an application for a Conditional Use Permit to allow for additional parking from what is required by ordinance. The development would be a six unit, three story condominium building at 5845 Stagecoach Trail North. In October 2024, Mr. Randazzo applied for a Comprehensive Plan Amendment to change the land use classification of Industrial use to Residential/Business Transitional use; Conditional Use Permits for building height, parking, and density bonus; and Design Guidelines/Site Plan review for the project. At their December 10, 2024, meeting the City Council denied the requests for the Conditional Use Permits but approved the Comprehensive Plan Amendment. Mr. Randazzo has redesigned the building to comply with the building height, density, and the Design Guidelines review. The Conditional Use Permit for parking is still required in that the parking provided in the plans exceeds what is required by ordinance. The review is based upon the following submittals: Exhibit 1: Project Narrative Exhibit 2: Project Location Exhibit 3: Existing Site Conditions Exhibit 4: Site Plan (C200) Exhibit 5: Landscape Plan (L100) Exhibit 6: General Information — Perspectives (A00.01) Exhibit 7: General Information — Perspectives (A00.02) Exhibit 8: Architectural Site Lighting Plan (A20.01) Exhibit 9: Photometric Plan Exhibit 10: Plan — Parking (A30.00) Exhibit 11: Plan — First Floor (A30.01) Exhibit 12: Plan — Second Floor (A30.02) Exhibit 13: Plan — Roof (A30.03) Exhibit 14: Exterior Elevations (A40.00) Exhibit 15: Exterior Elevations (A40.01) Exhibit 16: General Information — Perspectives — Materials (A00.03) Exhibit 17: Light Fixtures — Wall and Bollard PROJECT DESCRIPTION The project narrative is as follows and as found as Exhibit 1. Project Overview: JACC Capitals is proud to present the development of a 6-unit apartment building near the scenic and historic town of Stillwater, Minnesota. Located along the picturesque St. Croix River, this project offers future residents a modern, elegant living experience while embracing the natural beauty and charm of the surrounding area. The development seeks to balance sophisticated architectural design with the tranquility of riverside living, making it a premium residential choice in Stillwater. Please see the supporting document for light fixtures, construction, etc. Unit Composition: 6-unit building will offer a variety and sizes of 2 bedroom and 3 bedroom units each designed to maximize natural light and river view for the back units of the apartment. ISSUES ANALYSIS Adjacent Uses. Uses adjacent to the subject site include open area to the north, Highway 95 to the east, the Xcel Energy Substation to the south, and a single family neighborhood to the west. Comprehensive Plan. The Comprehensive Plan 2018 Proposed Land Use Map designated this area as Industrial. This reflects the previous use that was a commercial business and the use to the south which is the Xcel Energy Substation. The City Council approved a land use classification of Residential/Business Transitional Use for the subject property at their December 10, 2024, meeting. The land use classification change has been submitted and approved by the Metropolitan Council. Zoning. The property is currently zoned R/B - Residential Business Transitional District. Multiple family structures are a permitted use in the District. Building Height. Section 401.15.C.2 allows for a building height of 35 feet in the R/B District. The proposed building will be three stories and 33 feet, 4 3/4 inches to the top of the flat roof of the building. The height of the parapet is 2 feet, 3 inches above the roof and the elevator is 4 feet above the roof. The measurements are taken from the median grade. A Conditional Use Permit is no longer required for the proposed height of the structure. Density. Section 401.15.C.3 specifies that 2,500 square feet of lot area is required per unit (500 square feet is to be added for each bedroom over two bedrooms per unit). The unit count for the project is as follows: 1 Bedroom Units: 0 2 Bedroom Units: 6 3 Bedroom Units: 0 Total: 6 The lot area is 15,246 square feet. The six units would require a lot size of 15,000 square feet. A Conditional Use Permit is not required to allow a density bonus. Parking. The Zoning Ordinance requires at least one parking space per unit for multifamily structures or a total of six stalls for this development. The plans indicate 13 covered parking stalls, one of which is disability accessible. The proposed parking is over the amount of required parking and requires Conditional Use Permit review. The Planning Commission should comment on the additional parking. If the condo project only provided six stalls, the additional resident and guest parking would impact the surrounding streets. Setbacks. The R-B District specifies setback requirements as follows: 30 feet front yard, 30 feet rear yard, and 10 feet side yard. The proposed building will have a 30 foot front yard setback, 10 feet side yard setbacks and a 30 foot rear yard setback. The access drive and the front parking area are compliant with 10 foot setbacks. Minimum Floor Area. The Zoning Ordinance requires that multi-family housing has the following minimum floor areas per unit: Efficiency and One Bedroom Units: 600 square feet Two Bedroom Units: 720 square feet More than Two Bedroom Units: An additional 100 square feet for each Additional bedroom. The proposed units will be compliant with the requirements. Proposed Street Access. The site will be accessed from Stagecoach Trail North. The driveway is at the south side of the lot and should not create issues with 58th Street North to the west. Trails/Sidewalks. There are no sidewalks or trails along Stagecoach Trail North. There is access to trails just north of the site and crossing Stagecoach Trail North to 58th Street will provide access to trails and parks. Tree Preservation/Landscaping. There are no significant trees on site and the Applicant has provided a landscape plan. The landscaping is focused on the front of the site along Stagecoach Trail North. The plan shall be subject to the final approval of the City Arborist. 3 Grading and Drainage. Detailed grading and drainage plans have been provided as part of the development submittals. The City Engineer and the Middle St Croix Water Management Organization shall review and approve the grading and drainage plans. Utilities. A utility plan has been submitted. The final utility plan is subject to review and approval from the City Engineer. Lighting. A lighting plan has been provided that includes architectural light fixtures to be provided as accents on the building. Bollard light fixtures are proposed in the boulevard area in front of the parking area. Other decorative light fixtures are proposed for the building. A photometric plan has been provided that is compliant with the ordinance. Section 401.15.6.7. of the Zoning Ordinance allows for the use of non-full cut off fixtures with the approval of the City Council. Signage. The Applicant has proposed no signage other than the identification of the street address. Any signage proposed shall be compliant with the Zoning Ordinance and require a sign permit. Mechanical Equipment. The mechanical equipment shall be located within the building. If any mechanical equipment is ground mounted or visible from adjacent streets shall be screened as required by the Zoning Ordinance. Trash/Recycling. All the trash storage and recycling will be internal to the building. Architectural Design Guidelines/Site Plan. The application materials indicate elevations and perspective diagrams for the proposed building. The building will be a combination of exterior installation and finish system, masonry block, and aluminum batten and pergola systems. Multiple family buildings are not reviewed under the commercial Design Guideline requirements but under the building and architectural appearance requirements of Section 401.15.C.8. of the Zoning Ordinance. A review of the building requirements is as follows: f. Multiple Family Containing Six (6) Units or More For New Construction: 1) Mass and Scale a) Each multiple family building containing six (6) or more dwelling units shall feature a variety of massing proportions, wall plane proportions, roof proportions and other characteristics similar in scale to those of single family detached dwelling units, so that such larger buildings can be aesthetically integrated into a lower density neighborhood. The following specific standards shall also apply to such multiple family dwellings: 4 Comment: The mass of the building is adequately broken into segments by the angles of the front building façade and the use of different building materials at the base and on the walls. (1) Roofs. Each multiple family building will feature a combination of primary and secondary roofs. Primary roofs will be articulated by at least one (1) of the following elements: (a) Changes in plane and elevation. (b) Dormers, gables or clerestories. (c) Transitions to secondary roofs over entrances, garages, porches, bay windows. Comment: The roofline is broken by the variations of the roof and facades. (2) Facades and Walls. Each multiple family dwelling shall be articulated with projections, recesses, covered doorways, balconies, covered box or bay windows or other similar features, dividing large facades and walls into human scaled proportions similar to the adjacent single family dwellings, and shall not have repetitive, monotonous, undifferentiated wall planes. Comment: The facades of the building are broken by the angles as well as the building material types. b) Each multiple family building shall feature walls that are articulated by at least two (2) of the following elements within every thirty (30) foot length of the facade: (1) Recesses, projections or significant offsets in the wall plane of at least four(4) feet. (2) Distinct individualized entrances with functional porches or patios. (3) Chimneys made of masonry, or other contrasting material that projects from the wall plan. (4) Balconies. (5) Covered bay or box windows. 5 Comment: The building walls are adequately varied. b) Variation Among Repeated Buildings. For any development containing at least twenty-four (24) and not more than forty- eight (48) dwelling units, there will be at least two (2) distinctly different building designs. For any such development containing more than forty-eight (48) dwelling units, there will be at least three (3) distinctly different building designs. For all developments, there will be no more than two (2) similar buildings placed next to each other along a street or major walkway spine. Comment: One building is proposed. c) Distinctly different building designs shall provide significant variation in footprint size and shape, architectural elevations and entrance features, within a coordinated overall theme of roof forms, massing proportions and other characteristics. To meet this standard, such variation shall not consist solely of different combinations of the same building features. Comment: One building is proposed. The design of the building is compliant with the building and architectural appearance requirements of Section 401.15.C.8. of the Zoning Ordinance. Conditional Use Permit Criteria. The conditional use permit criteria, found in Section 401.03.A.7 of the Zoning Ordinance, are found as follows: 1. Relationship to the specific policies and provisions of the municipal comprehensive plan. 2. The conformity with present and future land uses in the area. 3. The environmental issues and geographic area involved. 4. Whether the use will tend to or actually depreciate the area in which it is proposed. 5. The impact on character of the surrounding area. 6. The demonstrated need for such use. 7. Traffic generation by the use in relation to capabilities of streets serving the property. 8. The impact upon existing public services and facilities including parks, schools, streets, and utilities, and the City's service capacity. 9. The proposed use's conformity with all performance standards contained herein (i.e., parking, loading, noise, etc.). Comment: The Planning Commission should review the above criteria regarding the request for the parking conditional use permit. City Staff sees no issues with the request as proposed. 6 CONCLUSION / RECOMMENDATION Subject to the preceding review, City staff recommends the Planning Commission consider the following request for a six unit, three story condominium building at 5845 Stagecoach Trail North, subject to the conditions that follow: • Conditional Use Permit for Parking 1 . The Fire Chief and Police Chief shall approve the final plans to determine the accessibility of emergency vehicles throughout the development. 2. The landscape plan shall be subject to review and approval of the City Arborist. 3. The grading and drainage plans shall be subject to City Engineer and the Middle St Croix Water Management Organization approval. 4. All utility plans shall be subject to review and approval by the City Engineer. 5. The Planning Commission and City Council shall comment on the proposed number of parking stalls that exceed the City requirement. 6. All lighting fixtures are required to be installed in compliance with the lighting standards of the Zoning Ordinance or as approved by the City Council. 7. All the trash storage and recycling shall be internal to the building. 8. Any mechanical equipment that is ground mounted or visible from adjacent streets shall be screened as required by the Zoning Ordinance. 9. Any proposed signage for the site shall be compliant with the Zoning Ordinance and require a sign permit. C: Julie Hultman 7 Julie Hultman From: CJ Randazzo Sent: Tuesday, February 11, 2025 9:15 PM To: Julie Hultman Subject: Project Narrative Follow Up Flag: FollowUp Flag Status: Flagged JACC Capitals 6-Unit Apartment Building Project Overview:JACC Capitals is proud to present the development of a 6-unit apartment building near the scenic and historic town of Stillwater, Minnesota. Located along the picturesque St. Croix River, this project offers future residents a modern, elegant living experience while embracing the natural beauty and charm of the surrounding area.The development seeks to balance sophisticated architectural design with the tranquility of riverside living, making it a premium residential choice in Stillwater. Please see supporting documents for light fixtures, construction etc. Unit Composition: 6—unit building will offer a variety and sizes of 2bd and 3bd units with each designed to maximize natural light and river views for the back units of the apartment. C.J. Randazzo 1 CrO / 4:;:1-'. . ,..„ 7,,,,. lk:2:1/4:,,, '''' ,,- . -r':., --litrok„.., .. cr. 1 ` r ,_' • �i > • �, - --- Y, ..sue'% . i a• .-�Y ; � ay- ,. � ." ow or /„..., , ._ k 4 w .-, -1 pk \'',4- _ .„ . ..„ , x �k F[ * ' 2 -�°'°-vx673"`. -- - - --- EXISTING SITE CONDITIONS . �� -' .` �_ .� ���� �_.`` _ `�.�_ •- Lot Address: x,6715-.� - 5845 Stagecoach Trail x677.5 Oak Park Heights, MN 55082 x676.7 X 76.2 677.3 4 l 680.7 ` - x677.4 N x677.0 x67r-F- x67$,1 1 76.3 x 679.6 _ x 655.3 x652.2 680.7 -� .� x677.7 ` 1 � x679.5 _. � �, � � ,� ,1 t x678.8 I �� Bit. x678.} 651.0 � � � ti •� '3 680.3 x678.6 1 ` x679.0 x676. �, ':� ;� ,� ;1 �.650.8 i x677.6 x679.4 xi)78.0 l l i x651.0 it. Bit. Bit. x678.3 x 75.8 x678.4 x677.3 x6516.6 Q 10 20 � x679.0 x678.1 x650.7 649.2 I Scale in feet x679.3 x678.1 674.8 679.9 x678.7 x 78.5 9653.9 D.3/'] x679.2 ! 52.5 rr�-7 x678.6 x675.6 75.5 ilk r n x67.8.2 r : x658.3 x654.6 x678.6 Bit. 5 � p C�a .00'�" 77.9 Bit. x678.4 ��i ;� RECEIVED OCT 14 2024 f ,r x659.9 ;' x677.� 1F. 679.3 r •9 x677.9 x669.5 f 656.0 �(827.70) Denotes proposed Elev. x665:4. ae6O2;6 ' x660.1 57.5 827.70 Denotes Existing Elev. exx 6 71.4 .i fl Denotes Proposes 1 i Gross lot area = 15000 s.f. Direction of Surface x674.0 Bituminous Pvmt. = 3475.39 s.f. Percent Impervious = 23.17% Drainage x6C,8.? ds Denotes down spout 679.0 x678 I hereby certify that this plan, survey, or report was HP Denotes highpoint x674 2 x671.6 prepared by me or under my direct supervision and that I ti am a duly Registered Land Surveyor under the laws of the SITE DEVELOPMENT PLAN Willis L. Gilliard State of Minnesota. As Surveyed by me this 28th day of Civil Engineer and Labd Surveyor ! Marc 023 PO Box17 - for Jacc capital Holdings, -LLC Saint Michael, hlinnesolati'55376 612-382-0795 Willis L. Gillia d, P.E., & R.L.S., Minn. Reg. No. 9587 (�( 3 1 4 I i 51 4 5 20SXT • - &SydE $UtLD1T6C] 00* 0 SITE DETAILS 1 B612 CURB AND GUTTER 15 HANDICAP ACCESSIBLE SIGNAGE AND STRIPING 32 CURB CUT WITH RIPRAP 38 INFILTRATION BASIN 0 SITE KEYNOTES A MATCH EXISTING CURB B MATCH EXISTING CONCRETE PAVEMENT WITH SAWCUT C PAINT4'WHITE DIAGONAL STRIPING D FLUSH CURB E TRANSITION CURB C-1148 Hours before digging: 811 or call811.com SITE LEGEND V EXISTING PROPOSED s PROPERTY LINE LOT LINE SETBACK LINE - - - - - - - - EASEMENT LINE CURB AND GUTTER CJ TIP -OUT CURB AND GUTTER - - POND NORMAL WATER LEVEL RETAINING WALL FENCE I� CONCRETE PAVEMENT G ❑ ❑ ❑ CONCRETE SIDEWALK ~ ® HEAVY DUTY BITUMINOUS PAVEMENT NORMAL DUTY BITUMINOUS PAVEMENT Q NUMBER OF PARKING STALLS Q TRANSFORMER J V • SITE LIGHTING J TRAFFIC SIGN d N y-� POWER POLE a p V Z ❑ >< / BOLLARD / POST Q a V _j GENERAL SITE NOTES Qa = a 1 BACKGROUND INFORMATION FOR THIS PROJECT PROVIDED BY WILLIS L GILLIARD, SAINT a MICHAEL MN, 03/2812023, MN 2 LOCATIONS AND ELEVATIONS OF EXISTING TOPOGRAPHY AND UTILITIES AS SHOWN ON THIS PLAN ARE APPROXIMATE CONTRACTOR SHALL FIELD VERIFY SITE tONO1T1AN5 AND UTILITY fag LOCATIONS PRIOR TO EXCAVATIONICOIVS RUCITON. IF ANY DISCREPANCIES ARE FOUND, THE ENGINEER SHOULD BE NOTIFIED IMMEDIATELY, - 3 REFER TO BOUNDARY SURVEY FOR LOT BEARINGS, DIMENSIONS AND AREAS, z 3z- A ALL DIMENSIONS ARE TO FACE OF CURB OR EXTERIOR FACE OF BUILDING UNLESS OTHERWISE NOTED - i v 5 REFER TO ARCHITECTURAL PLANS FOR EXACT BUILDING DIMENSIONS AND LOCATIONS OF EXITS, RAMPS, AND TRUCK DOCKS - s 6, ALL CURB RADII ARE SHALL BE 3 0 FEET (TO FACE OF CURB) UNLESS OTHERWISE NOTED, o V o 7 ALLCURB AND GLITTER SHALL BE B612 UNLESS OTHERWISE NOTED. n 8 THE CONTRACTOR SHALL BE RESPONS)BT,E FOR P3RCNIO(NG AND MAINTAINING TRAFFIC w CONTROL DEVICES SUCH AS BARRICADE$, WARNING SIGNS- DIWTIONAL SIGNS- FLAGGERS z Af4D LIGHTS TO CONTROL THE MOVEMENT OF TRAFFIC WERE NECESSARY PLACEMENT OF V THESE DEVICES SHALL BE APPROVED BY THE CITY AND ENGINEER PRIOR TO PLACEMENT- V 11A vi TRAFFIC CONTROL DEVICES SHALL CONFORM TO APPROPRIATE MNDOT STANDARDS. a 4'j Q 9 BITUMINOUS PAVEMENT AND CONCRETE SECTIONS TO BE IN ACCORDANCE WITH THE d LA F Z w RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER Y = a Y 10 CONTRACTOR SHALL MAINTAIN FULL ACCESS TO ADJACENT PROPERTIES DURING O W V CONSTRUCTION AND TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES. = Ne 11 SITE LIGHTING SHOWN ON PLAN IS FOR REFERENCE ONLY. REFER TO LIGHTING PLAN PREPARED O BY OTHERS FOR SITE LIGHTING DETAILS AND PHOTOMETRICS. SITE DEVELOPMENT SUMMARY EXISTING ZONING: R-B, RESIDENTIAUBUSINESS TRANSITIONAL o` m • ADDRESS 584S STAGECOACH TRAIL = 6 OAK PARK HEIGHTS, MN 55082 m £ • PROPERTY AREA: 15,000 SF (0.34 AC) D e g PERVIOUS SURFACE S;608 SF (37%) s d • IMPERVIOUS SURFACE(RATIO) 9.392 SF (63%) e BUILDING GROSS SIZE 7040 SF • BUILDING SETBACK PER CODE 301-FRONT -- y 10'=SIDE . $ 30'=REAR c �f PARKING SETBACK 10'=PROPERTY LINE r. a PARKING SPACE:/DRIVF AISLE 9' WIDE X 20' LONG, 22' AISLE 2' OVERHANG PERMITTED Z PARKING RATIO REQUIREMENT CITY OF OAK PARK HEIGHTS Q MULTIFAMILY: 25PACE5 PER UNIT J TOTAL SPACES REQUIRED: 12 SPACES (6 UNITS) LJ ( F PARKING PROVIDED: 13 ' I I t/1 l t 1- = 10' NUMBER: I "- 10' 20' 30, C 2 O O NO I FOR CONSTRUCTION DATE 10/14/2024 wot PLANT SCHEDULE CODE I OTY IBOTANICAL/ COMMON NAME SIZE I SPACING O.C. (MATURE SIZE CONIFER U SHRUBS NU1 IS j IUNIPERUS CNI EN IS'MQ L P /MIN 1lJLFP� iUNIPBR NS i f AO' H 3.5 W 4 p RENNIALS HRD 16 IH M ROCAL X'HAPPY TURNT / HAPPY A TURNS DAYLILY I+r1 COIN 1a' CIC • H FS• 1S W ib.20- GRASSES ILFG 1 fI CALA7IAAG90ST15 . ACL7TI LORA'KARL FC)ERSTEW 1 KARL RSTER FERTFIER RE eT CON(- . 3T O C- HW5• W 2.3 PDS f S SPORUdCJLUS HETEROLEPIS 1 IM10 1DROPSEED Nl Cl-7NT. Zi' O.0 101;-3 W 2-; ABBREVIATIONS: B&B = BALLED AND BURLAPPED CAL = CALIPER HT. = HEIGHT MIN =MINIMUM O.0 = ON CENTER CITY .= QUANTITY CONT. = CONTAINER NOTE: QUANTITIES ON PLAN SUPERSEDE LIST QUANTITIES IN THE EVENT OF A DISCREPANCY LANDSCAPE LEGEND y� Ohl 00 y SHRUBS MN-DOTSEEDMIX33-261 ti 'TIRI i,,.t EXISTING TREE Q PERENNIALS JkuI e / 1 EDGER LANDSCAPE SUMMARY PARKING AREAS SHALL BE SCREENED WITH A COMBINATION OF LANDSCAPE MATERIALS, LANDFORM AND DECORATIVE FENCING OR WALLS SUFFICIENTTO SCREEN PARKED CARS ON A YEAR-ROUND BASIS WHILE PROVIDING ADEQUATE VISIBILITY FOR PEDESTRIANS ..CITY REQUIREMENTS MET., LANDSCAPE KEYNOTES 0 A WOOD MULCH (TYP) B EDGER(TYR) C SOD (TYP ) D SEED SEEDING NOTES SEED MIX MN -DOT 33-261 STORMWATER SOUTH.W EST (OR A MIX COMPRISED OF SIMILAR VARIETIES OF GRASSES TO BE APPROVED BY LANDSCAPE ARCHITECT) SEED MIX AVAILABLE FROM TWIN CITIES SEED COMPANIES (WRlcltyseed com 1 800 545.TURF) SEED MIX TO BE APPLIED AT RATE RECOMMENDED BY SUPPLIER SEED MIX TO BE APPLIED DURING RECOMMENDED PLANTING SEASON. AND USING AN APPROVED METHOD, AS FOUND IN THE MN -DOT SEEDING MANUAL C+)I 48 Hours before digging: 811 or ca11811.com DI AILITIIUr AIATCC nlrnwn +nce 1 CONTRACTOR SHALL CONTACT COMMON GROUND ALLIANCE AT 811 OR CALLS11 COM TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF ANY PLANTS OR LANDSCAPE MATERIAL 2 ACTUAL LOCATION OF PLANT MATERIAL IS SUBJECT TO FIELD AND SITE CONDITIONS 3 NO PLANTING WILL BE INSTALLED UNTIL ALL GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA 4 ALL SUBSTITUTIONS MUST BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO SUBMISSION OF ANY BID AND/OR QUOTE BY THE LANDSCAPE CONTRACTOR 5 CONTRACFOR SHALL PROVIDE TWO YEARGUARANTi E OF ALL PLANT MATERIALS. THE GUARANTEE BEGINS ON THE DATE OF THE LANDSCAPE ARCHITECTS OR OWNER'S M+IITTIN ACCEPTANCE OF THE INITIAL PLANTING REPLACEMENT PLANT MATERIAL SHALL HAVE A ONE YEAR GUARANTEE COMMENCING UPON PLANTING 6 ALL PLANTS TO BE SPECIMEN GRADE, MINNESOTA-GROWN AND/OR HARDY SPECIMEN GRADE SHALL ADHERE TO. BUT IS NOT LIMITED BY, THE FOLLOWING STANDARDS: ALL PLANTS SHALL BE FREE FRO DISEASE PESTS, WOUNDS. SCARS. ETC ALL PLANTS SHALL BE FREE FROM NOTICEABLE GAPS. HOLES OR DEFORMITIES ALL PLANTS SHALL BE FREE FROM BROKEN OR DEAD BRANCHES ALL PLANTS SHALL HAVE HEAVY, HEALTHY BRANCHING AND LEAFING CONIFEROUS TREES SHALL HAVE AN ESTABLISHED MAIN LEADER AND A HEIGHT TO WIDTH RATIO OF NO LESS THAN 5 3 7 PLANTS TO MEET AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z601-2014 OR MOST CURRENT VERSION) REQUIREMENTS FOR SIZE AND TYPE SPECIFIED 8 PLANTS TO BE INSTALLED AS PER MNLA & ANSI STANDARD PLANTING PRACTICES 9. PLANTS SHALL BE IMMEDIATELY PLANTED UPON ARRIVAL AT SITE PROPERLY HEEL -IN MATERIALS IF NECESSARY: TEMPORARY ONLY, 10 PRIOR TO PLANTING. FIELD VERIFY THAT THE ROOT COLLAR/ROOT FLAIR 15 LOCATED AT THE TOP OF THE BALLED & BURLAP TREE IF THIS IS NOT THE CASE SOIL SHALL BE REMOVED DOWN TO THE ROOT COLLARIROOT FLAIR WHEN THE BALLED & BURLAP TREE 15 PLANTED, THE ROOT COLLAR/ROOT FLAIR SHALL BE EVEN OR SLIGHTLY ABOVE FINISHED GRADE 11 OPEN TOP OF BURLAP ON BB MATERIALS, REMOVE POT ON POTTED PLANTS. SPLIT AND BREAK APART PEAT POTS 12 PRUNE PLANTS AS NECESSARY - PER STANDARD NURSERY PRACTICE AND TO CORRECT POOR BRANCHING OF EXISTING AND PROPOSED TREES 13 WRAP ALL SMOOTH -BARKED TREES -FASTEN TOP AND BOTTOM REMOVE BY APRIL 1ST 14 STAKING OF TREES AS REQUIRED. REPOSITION, PLUMB AND STAKE IF NOT PLUMB AFTER ONE YEAR 15 THE NEED FOR SOIL AMENDMENTS SHALL BE DETERMINED UPON SITE SOIL CONDITIONS PRIOR TO PLANTING LANDSCAPE CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT FOR THE NEED OF ANY SOIL AMENDMENTS 16 BACK FILL SOIL AND TOPSOIL TO ADHERE TO MN/DOT STANDARD SPECIFICATION 3877 (SELECT TOPSOIL BORROW) AND TO BE EXISTING TOPSOIL FROM SITE FREE OF ROOTS, ROCKS LARGER THAN ONE INCH, SUBSOIL DEBRIS, AND LARGE WEEDS UNLESS SPECIFIED OTHERWISE MINIMUM 6' DEPTH TOPSOIL FOR ALL LAWN GRASS AREAS AND 1Z' DEPTH TOPSOIL FOR TREE, SHRUBS, AND PERENNIALS 17 MULCH TO BEAT ALL TREES AND SHAD HAVE 4" DEPTH OF SHREDDED HARDWOOD MULCH SHREDDED HARDWOOD MULCH TO BE USED AROUND ALLT91S WITHIN TURF AREAS. MULCH TO BE FREE OF DELETERIOUS MATERIAL AND NATURAL COLORED, OR APPROVED EQUAL ROCK MULCH TO BE BUFF LIMESTONE 1 1/2' TO 3- DIAMETER AT MINIMUM 3' DEPTH, OR APPROVED EQUAL ROCK MULCH TO BE ON COMMERCIAL GRADE FILTER FABRIC BY TYPAR OR APPROVED EQUAL WITH NO EXPOSURE. MULCH AND FABRIC TO BE APPROVED BY OWNER PRIOR TO INSTALLATION MULCH TO MATCH EXISTING CONDITIONS (WHERE APPLICABLE) 10 EDGING TO BE COMWRCIAL GRADE VALLEY -VIEW SLACK LTAMOND (OR EQUAL) DOLT' EDGING OR SPADED EDGE, AS INDICATED. POLY EDGING SHALL BEE PLACED WITH SMOOTH CURVES AND STAKED WITH METAL SPIKES NO GREATER THAN 4 FOOT ON CENTER WITH BASE OF TOP BEAD AT GRADE FOR MOWERS TO CUT ABOVE WITHOUT DAMAGE UTILIZE CURBS AND SIDEWALKS FOR EDGING WHERE POSSIBLE SPADED EDGE TO PROVIDE V-SHAPED DEPTH AND WIDTH TO CREATE SEPARATION BETWEEN MULCH AND GRASS INDIVIDUAL TREE SHRUB, OR RAIN -GARDEN BEDS TO BE SPADED EDGE UNLESS NOTED OTHERWISE EDGING TO MATCH EXISTING CONDITIONS (WHERE APPLICABLE) 19 ALL DISTURBED AREAS TO BE SLIODED DR SEEDED, UNLESS OTHERWISE NOTED PARTING LDT ISLANDS TO BE SODDED WITH SHREDDED m&BOWOOD MULCN AROIJ.YU ALL TREES AND SHRUBS. SOD YO BE STANDARD MINNESOTA GROWN AND HAROV SLUEGRASS MDC FREE Of LAWN WEEDS ALL TOPSOIL AREAS TO BF RAKED TO REMOVE DE15AM AND ENSURE DRAWM1Gi SLOPE S OF 3:1.OR GREATER sHAU, BE STAKED SEED AS SPEOFILD AND PER NLWr)OT SOKIFICATIONS rF NOT INoCATM ON LANDSCAPE PLAN. SEE EROSION CONTROL PLAN 20. PROVIDE IRRIGATION TO ALL PLANTED AREAS ON SITE IRRIGATION SYSTEM TO BE DESIGN/BUILD BY LANDSCAPE CONTRACTOR LANDSCAPE CONTRACTOR TO PROVIDE SHOP DRAWINGS TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION OF IRRIWTION SYSTEM. CONTRACTOR TO PROVIDE OPERATION MANUALS. AS -BUILT PLANS, AND FORMAL AROGRA"141 . SYSTEM SHALL BE WINTERIZED AND HAVE SPRING STARTUP DURING FIRST YEAR OF OPERATION SYSTEM SHALL HAVE ONE-YEAR WARRANTY ON ALL PARTS AND LABOR ALL INFORMATION ABOUT INSTALLATION ANO SCHEDULING CAN BE OBTAINED FROM THE GENERAL CONTRACTOR 21. CONTRACTOR SHALL PROVIDE NECESSARY WATERING OF PLANT MATERIALS UNTIL THE PLANT IS FULLY ESTABLISHED OR IRRIGATION SYSTEM IS OPERATIONAL OWNER WILL NOT PROVIDE WATER FOR CONTRACTOR 22. REPAIR REPLACE OR PROVIDE SOD/SEED AS REQUIRED FOR ANY ROADWAY BOULEVARD AREAS ADJACENT TO THE SITE DISTURBED DURING CONSTRUCTION Z3. REPAIR ALL DAMAGE TO PROPERTY FROM PLANTING OPERATIONS AT NO COST TO OWNER REMOVE CONTAINER SCARIFY SIDES, AND SET 501L MASS ON COMPACTED SOIL BASE MOUND MATCHING SHRUBS NATURAL GROIN WITH FINISHED GRADE MULCH AS SPECIFIED (AND FILTER FABRIC. ' AS INDICATED) • P L RC'� J EDGING AT RANTING BEDS AS SPECIFIED. ADIACENT TO LAWN AREAS SCARIFY SIDES AND BOTTOM OF HOLE ltl •� DEPTH PER CONTAINER SOIL DEPTH BACKFILL PLANT PIT WITH SPEOFIED PEA TING SOIL OR AS APPROVED SET CONTRINER ROOT SOIL ON UNDISTURBED SUBSOIL OR MIED COMPACTED SOIL MR DEPTH TO MATCH FINISH GRADE NTS SHRUB & PERENNIAL �W_ LA27-C CONTAINER PLANTING RFrFiVFn OrT i !) 2024 CA 1"=10' D' 10' 20' 30 A fti �L LU d r. U zz i Q J zE Q L J L: NUMBER L100 NOT FOR CONSTRUCTIONDAT, ^10/14/2024 C ONION mom L 1 1� . r. Fm ----5; 1 NOUN I -- AI 1 I k7l qAj 0232 Beth SI Nm SdN21er, MN 550U 1612532 d147 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 3 ISSUED FOR OEVELOPMEM APPICAMON-REV 2 20]2025 i R "'T t7mmld 1 ISSUED FOR DEVELOPMENT APP31wADON 1g142024 !!7 Dam JOB NUMBER 24 016 D604 GENERAL INFORMATION - PERSPECTIVES A00.02 --� FIXTURE DESCRIPTION FUCTUREO uEsc�n A WA B COLUMN LIGHT VLEFF LIGHTING MODEL LTP434-FT - 3000K C LINEAR SURFACE MOUNTED EXTERIOR LIGHTING COOPER LIGHTING: FAIL 811FE HVSL2 HIGH ABUSE 7 VUDE, SURFACE MODEL HVSL2-3000K O EXTERIOR WALL SCONCE -ADA COMPLIANT OXYGEN LIGHTING RICKIE LED OUTDOOR- SURFACE MODEL 3.7471 5 - BLACK COLORTEMP 3,000K SITE PLAN -LIGHTING qF'y':g � Ail k441- 9232 5R0 St N ft Sffl l . MN 55082 1612532A147 3 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 3 1SMAMF OEVELOPIANT APP�cnnaN-AFV2 2032025 2 >mPBEdHt stM.aw I B8L60TOROENEIOAVf3R APPICATION 10.14.2024 NO ISlpF DAIT JOBNUMBER 240160604 ARCHITECTURAL SITE LIGHTING PLAN A20.01 � OA i -- '4Bel Vi r r �f oA nA oA DD ° A oA pO �f BA 'DA _ '- •p0 00 GO 'CA GO 'to A •� bA OP aA •00 ' 1 'oA 0A 0A 'nA DIDCa 0A - r •p0 - 0 •nA •DA O.A 'DO •00 'oo - a 'OA OA'00 - .lIOA - � 'nA p0 Go 4 'OA oA 00 •0 Do _ - - O9 � •� O9 •0A 'p0 CA 9P GA 0A 0A _� -J ~ J •00 4A •DA 'a D -Do r_r OA •DD 4O pA 0D 0A 0.1 0.7 •� p7 'SZ ram.. 'i.IOA DA 'DA 'OA '4S 7 'e0 •j9 �. 00 6A 'D.0 G] _ •jf 3.4 •21 5 •q 5 r� '', OA 0.0 0 0 •0.2 OF '1A •1SS 7 5 •51 •23. Q 00 0.0 0a 40 '0'A•12.3 04 'pA - 0= O3 1+ a0 " aGJ'27? •26 l: aA DA D4 0Q 'S.7 �6 _. 4 'a4 'onO] 'bA 'S.Y ]b • 3 ,1 '29° •7� ~-� /!f�r�r a •OQ 'OA ,A '4b 'ill 1 ''Co � � •yp 'Do •04 D '0.0 co ta r 'Da •:03.a •j 5 20 • •mil •9 fbS.l•� •y0 •pY r 00 O4 ° •00 'Oh. •DDT •liA ', i ,� 'PO aD QA ' aq •1? ••yt *2Y A ����yy� 'p4 A. .DA 'O •AAS •5.► •a2 5.6 L ` 'tA•k .i '' ` T, _ ', 9A •p° a0 OA 'a7 60 'Sf y` �1F 9 I� _ 'S.1 •23 �� it •00 AA •na '{s •gn •iO q3 •27 n 123 - f1-An� �� �� •i'AO Do 'Do04 75 •1q Op' OA 12 'l94 •aD _- 'OA 'pA 0b aq 6 •D1?- r� 11 60 a4 OP 0A •DA 00 06 •OT 'la •ba . g+.1 ;: •. �lYltCTI Jr ��.:• �, 00 0 .DO 00 0a D7 •1A th A 4A :sr 0A OA .3s 'oB 71 0A AA °n 'aA 'DA 4 • '1S .41 'SA •ate 7] 'tR y 0A '0.0 DA � 'F.5 ..µq r2A '1a 79 3` '. '�; •177 •LP 'tA �J yi °A CA Q4 GA .�• .. ' 1 0A S •jy 9 •7 A _ .p 1 r 0A O •DA •59 •s _ - 1 00 'OA .. b•.�D` -� i:-: °.a.4A OA0:s 0.4 09 •{S '•17 '3.1 7.•2LE '8F1y75a'•�585 �S ,--'_ _ •�- 6 '�._ ••OB °•a 'ba �0 `'0.7 '0.0•5°� •° •'02 •plA p ° PO-3A•=�.O�-CD AA A 0Aa -00 A-. - - 'PA p8 '27 1.3 '0.3 0.2 00 O 606 °9 3 'AA .1 0n 00 OF 6.1 9p '3.9 1.7 5 0.3 . AO 0 3 04 70 •235 9.9 ^ AA 0R T•44 j-9 0P .dD 0A -- -_-�� 10101� '0.9 •p 11'� f D %P "• �yS '10.9 0.2 �. - 60 'DA OD i C y 4 . •D.2�- 'p4 1 bA 0A '0A _ ..'-� - 9' OF '1.,So1 •yr 7 '0.7 0A _ _ - 0S 0.9 .j 1 113 �ryy7.6 '3? •0R •an •°A aA 'OA OP.� 11 • -�_ 2 0S GA •Se •17.9 _ ip0`'DA DA 'Do OA�r _'��r -.- _-_- _ _ �G7 D► Ob .1� at ,.fig -_ '0.0 .Ob - - - •°'9 rr� - L'- �' % 1 J D - - 5 'kid AA ° ,09 1.5 p0 •DP 'n0 _ --'f J �O�frJ�-f rr�-r �......Y - 03- •D 1 �> •0.2 ; +"�� µJD -� _���� � ! �� dcuioffon 9umma l.vbelI CoIcType I Ava I Max I Min I AV.Win I Max/Min STfE Ilhrminpnee Fc 3.09 449 0.0 I N.A. I N.A. 1. Standard Reflectance of 80/50/20 unless noted otherwise 2. Not a Construction Document, for Design purposes only 3, Standard indoor talc points ® 30" A.F.F. unless noted otherwise 4. Standard outdoor talc points ® Grade unless noted otherwise 5. Egress talc points @ 0" A.F.F. 6. Mlazgar Associates assumes no responsibility for installed light levels due to field conditions, etc. lurnlnaire Schedule symbol Qty Label Monuioclurer Rescri Lion Arran ement Lum Lumens Lum Walls LLF 7 C COOPER LIGI-IING HVSL2--LD4-L0-35-UNV-O-EDX Single 5363 462 D. 900 SOLUTIONS - FAIL- SAFE (FORMERLY EATON L 5 B W E-EF USA LIP434 LR>+f - 116- Single 2283 42 0,900 0210 wo_ O¢o 0❑- "'-m y <3m�NE N3�P� 5� f-z°= N. E E u 0 Revisions � o �° w m v ii a` m 0 ° o urx ❑ ❑ Z Q J LU It--b o � 7- (.) o LU U 0 Q O O (LU D Q � y Page M of 1 rRl Bad IBA it N CONSTRUCTION PLAN - PARKING 3116' = V4r ] PLAN NOTES 1. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE UNO ALL DIMENSIONS MARKED'CLEAR' OR'MIN' SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING CARPET, STONE, TILE, FABRIC PANELS, MILLWORK, ETC 2 ALL PARTITIONS TO BE ASSUMED TO GO TO OECKISTRUCTURE ABOVE UNLESS OTHERWISE NOTED, 3 DO OR OPENINGS ARE DIMENSIONED TO CENTERLINE OF OPENING IFNOT DIMENSIONED, THE HINGE SIDE OF THE DOOR JAMBS SHALL BE SPACED 4" FROM THE FACE OF THE ADJACENT WALL, 4 UNDERCUT OF DOORS TO CLEAR TOP OF FLOOR FINISHES BY l W UNLESS OTHERWISE NOTED, 5 PATCHAND REPAIR SURFACES DAMAGED ASA RESULT OF WORK PERFORMED ON THIS PROJECT, PATCH L REPAIR EXISTING SURFACES AS REO'D TO RECEIVE NEW FINISH, fi NEW GYP. CONSTRUCTION AD.IOINING EXISTING CONSTRUCTION IN PLANE SHALL BE FLUSH WITH NO VISIBLE JOINTS, UNO 7, SEE LIFE SAFETY PLANS FOR WALL RATINGS AND FIRE EXTINGUISHER LOCATIONS, B KEYNOTES ARE LOCATED ON ENLARGED SHEETS FOR AREAS THAT HAVE ENLARGED PLAN CALL OUTS. KEYNOTES - PLAN 92]2 fiNh 51 NvN SUM�ar, MN 59062 1 612S32 4147 I STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION ] FdI MVaOIWWT 203.2025 IAWATK1N•164V7 2 'SD PRWjm 173470N 1 M71EUFpl K1b1 M6I21 10142024 J4'J'ICAIKN NO ISSUE f111TE JOB NUMBER 24 016 0604 PLAN -PARKING V A30.00 I KEYNOTES - PLAN p- - I I � i 1 �i I j t I I I I II 1 I I II N CONSTRUC'CION RLAN -FIRST FLOOR 3 r.,-,rr-r.,•�� 12 qv (5� g- fl 9272 fiRh Sl N.1h SBMrts, MN 55oB2 I612532 147 STAGECOACH CONDOS 5B45 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION ] ASE11}id{BEV9Ay�,71 203.2025 APPIGAMN-_ EV2 2 5O PRIM 1750.20# *SlMf0RMVELWWW 10142024 APPICAnON HO MUE WE JOBNUMBER24 F. 0, B. M PLAN -FIRSTT � f FLOOR A30.01 0— — — h f�l I I II 1 1 III _ II II 'I I I II `I II 1 I '1 l II II I, I I I I II !I II KEYNOTES - PLAN 9232 fifiN SI NUM SBNwIn, MN 55082 Ifi715324147 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 3 t7 t*afOR05Voj)AMw 2032025 APPICATION-REV2 2 WPaEmm 1{,10,2024 I UVii59 FOR EEVELO"AW %142024 APPICATION NO rAUE O81E JOB NUMBER 2l0li0i00 PLAN - SECOND Cy) FLOOR I CONSTRLICTtON PLAN - SECONI] LEVEL A30.02 J ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, LINO ALL DIMENSIONS MARKED'CLEAR' OR'MIN' SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING CARPET, STONE, TILE, FABRIC PANELS, MILLWORK ETC 2 ALL PARTITIONS TO BE ASSUMED TO GO TO DECK/STRUCTURE ABOVE UNLESS OTHERVW ENOTED 3 DOOR OPENINGS ARE DIMENSIONED TO CENTERLINE OF OPENING. IF NOT DIMENSIONED, THE ' q ' (A.q) l n) (B B�9 `�. / THE FACE OF THE EOACE HL OR JAMBS SHALL BE SPACED A.1 FROM 4' 7 7 7 I 4 UNDERCUTOFDOORS TO CLEAR TOP OF FLOOR FINISHESBVIMUNLESS OTHERWISE NOTED I I 5 PATCH AND REPAIR SURFACES DAMAGEDARESULT OFWORKPERFORMED j ON THIS PROJECT. PATCH S REPAIR EXISTING SURFACES AS REDID TO RECEIVE 1 NEWFINISH G NEW GYP. CONSTRUCTION ADJOINING EXISTING CONSTRUCTION IN PLANE SHALL BE FLUSH WITH NO VISIBLE JOINTS, LINO T SEE LIFE SAFETY PLANS UW S FOR WALL RATINGS AND FIRE EXTINGUISHER B KEYNOTES ARE LOCATED ON ENLARGED SHEETS FOR AREAS THAT HAVE JJJ f ♦ F f ENLARGED PLAN CALL OUTS I r:. ♦ Y r♦.r'• 1 �:` .,.- J� �+ 1 i" j• GREEN R F —�/ -'� _i 1. I r .i' KEYNOTES - PLAN X r r f & -4, f'. f rti i f4 f JIV.♦`..� f I I ♦ .�. wr f ♦/ II I ♦ r s l• .,yam`. �/�/tf �.._ — �- _ _ � _ �, \j< \jam/ i\ r1 r -I-t ��/�\�lf�\\� ♦ � .. �; �_� •fir I r \i\ ii j♦ i / +ti ��1 \�\�V1f �.�'•: `•./\:.. f ."` f'.^ I ti r' j ♦ j w - - GREEItl ROOF "N ♦ r \ `` - � .•mot �r /'•.. �z..-�;'ti_,=t - \\\ \ / / f � 466 I I l A II 1 I I II CONSTRUOTION PLAN -ROOF 3116'1'-0' s 3 Al 9232 SINvlh SBN 55662 161' M 167253632A147 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 7 I$MiDFOCEvncmwm 2032025 APPJWnOM.p : an Pwa+c rBnRE➢FOAAPPlcanoNNo 711.211� JOB NUMBER PLAN - ROOF Ca( A30.03 I I � I � ---1t-- - - -- - -� - ----- I I t I ELEVATOR LRIERRIIII I I ELEVATOR OVERRUN Ilk 13S-43N- Tio P T 33'-T ROOF 131.-4 W WOOD TONE ALUMINUM BATTENS LARGE FORMAT SIDING' STUCCO, CEMENTITIOUG PANELS OR METALPANELS SECON — —L I I�] — FIRST FLOOR dil — 10'-W I 1 . , CEMENTITIOUS LARGE FORMAT BLOCK/BRICK • 1 -D 100 -W EXTERIOR ELEVATION -SOUTH ELEVATOR EXTERIOR ELEVATION - EAST 3116' 1'-0" f RAILING IL &/4 14 9232 6M St NuM SUN—, MN 55062 16125324147 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 3 $51,E(1FOR UEtpLLPld3R 2032025 APPICATION-REV2 3 3D PAlCW 12"74 1 ISSVEL29RW ALOPMElL 10142024 APPICATIDN PC [55"" ➢ME JOB NUMBER 24016.0604 EXTERIOR ELEVATIONS A40.00 -C III I I ' ELEVATOR OVERRUN 1 ROOF I SEC R ST 1 ,I — I I I I� i I I jf dl I I �_ _ _ _ I • , �_ —. _ _ _ FIRSTI OR 1 I. I I r 1 I r O A- I - - PARKING 96' - 6o ' II I I I If EXTERIOR ELEVATION - NORTH _- 5 6• T T T T r I I I I I 1 II I I I I ELEVAT-k- xRR�N �'•. li II I 133•a3rr f ROOF - 1 - - - - 131'-431a' SEOQa11.1 FIRST�10. 0' A GRADE 1O0'-P I I I I 1 -P"KING EXTERIOR ELEVATION - WEST 3n�.,.-0• 2 Es, P_ 15 k O 9232 5Nh St Nalh 301v ,, MN 55082 16125324147 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 3_1 ISSUED FOR DEVELORJENT 2032025 J APPICATION-REV2 310 PA410 SSUEDFDRDEVELDPMENT 15,2 d APPIDATIDN ND IiBUF DART JOB NUMBER 24.010low EXTERIOR ELEVATIONS A40.01 COLOR: ROYAL OAK • VSEWRAIL • CABLE RAILING ALUMINUM UPRIGHTS WOOD CAP, SURFACE MOUNTED LINEAR SURFACE MOUNTED EXTERIOR LIGHTING COOPER LIGHTING: FAIL SAFE COLUMN LIGHT WE-EF LIGHTING � 1 E m EXTERIOR WALL SCONCE -ADA COMPLIANT OXYGEN LIGHTING - RICKIE LED OUTDOOR — EXTERIOR INSULATION AND FINISH SYSTEM }EXTAIRE SANOPEBBLE FINE COLOR ANTIODE GRAY EXTERIOR INSULATION AND FINISH SYSTEM TEXTURE: SANDPEBBLE FINE COLOR: WHITE HAZE ECHELON MASONRY -ARIA SLIM STONE GROUND FACE MATH SEALER COLOR: MIDNIGHT ez3z sAln s Nalh SlAv t6l'253556A2 t 6724117 STAGECOACH CONDOS 5845 STAGECOACH TRAIL N OAK PARK HEIGHTS, MN 55082 NOT FOR CONSTRUCTION 7 WI. DFOR pEVELOPMpIIt Z012025 APPICATION-REV2 } BD PAZINB 1}.A.7AN I IwADTOItW45L0FM0IT 10147024 APPICATION Itl I" RATE JOB NUMBER 24016060, INFORMATION - MATERIAL BOARD A00.03 (31 RICKIE Outdoor oxygen 3-747-xx FIXTURE TYPE LOCATION LIGHT FIXTURE D PROJECT DATE 111111 xi y -16 Brushed Aluminum -15 Black LIGHT SOURCE LED Arrays,3000K,CRI 90 LUMINAIRE POWER 11.7W at 120V RATED LIFE 50000 hr RL OPTIONAL COLOR TEMPERATURES 3000K Only �..I LUMEN OUTPUT Delivered:616 Im(LM-79) INPUT VOLTAGE 100V to 277V AC,50/60Hz DRIVER OUTPUT 450mA, 18W max power W Er, DIMMING Non-dimmable CONSTRUCTION Cast Aluminum Housing DIFFUSER -Clear Glass FINISHES Black(-15),Brushed Aluminum(-16) DIMENSIONS W: 6.25" MOUNTING 4"Octagonal J-Box H: 6.25" (Installer must provide a bead of caulk between Ext: 2.75" fixture housing and mounting surface) M.C: 3.125" From top of fixture STANDARDS ETL Wet listed,ADA Compliant,Conforms to UL STD 1598, Certified CAN/CSA STD C22.2 No 250.0. Order example for standard fixture: 3-747-15(x-Voltage-xxx-Sequence#-xx-Finish) ADA 1 3: 120V to 277V tntertek 201 Railhead Road,Fort Worth,TX 76106 - Tel.(877)607-0202 - www.oxygenlighting.com LIGHT COLUMNS LANDSCAPE 157.48 59.05 i 15.75 Diffused LTP434-FT 4.7z LTP444-FT 'MINIM'S I 37 W AA 25501m 1 i 1 •For detailed specifications,product codes and latest performance data,refer to www.we-ef.com 2700 K 3000 K 4000 K •Shown above are rated lumens for 3000 K at Tq=25°C •For accessories,refer to www.we-ef.com LTP434 LED-FT we-ef Light Columns Configurations Light distribution Part ID Light source Rated Rated input CRI Weight(lb) lumens power three sided light output 116-0210 LED-FT-37W(3000K) 2546.5 42 W 80 37.50 Aft116-0211 LED-FT-37W(4000K) 2656.2 42 W 80 37.50 1111111, WE-EF LIGHTING USA,LLC 410-D Keystone Drive,15086 Warrendale,PA 15086-Phone:+1 724 742 0030 customersupport.usa@we-ef.com-https://we-ef.com/us Subject to technical changes and errors.-Generated on 10/10/2024 4 of 4 LTP400 .isiii,..,7,... \‘'\\- I "€ ./ li '. t -,,as •- ~.�4 �a $ k i ' ' /flit/7/ I • • . . —1111111.1111. ,Cti Luminaire housing: Marine-grade,all-aluminum construction CLASS II Corrosion protection: 5CE,including PCS hardware I 1KW Driver: Integral EC electronic converter Main lens: Prismatic polycarbonate,UV-stabilized 3 x 120°offset Gasketing: Silicone rubber gaskets Optics: CAD-optimized for superior illumination and glare control OLC`One LED Concept Mains connection: Service door with fused cable connecting box Control: 0-10V Dimmable Eli and Edythe Broad Art Museum Available distribution: Standard colors: Michigan State University,East Lansing(US) Diffused ■ Architect:Zaha Hadid Architects RAL 9004 9007 8019 9016 Lighting design:ARUP Et Peter Basso