HomeMy WebLinkAboutBP 2024-00124 - Electric Permit & Inspection Reports.. DEPARTMENT OF LABOR AND INDUSTRY 443 Lafayette Road N., St. Paul, MN 55155 (651) 284-5026, www.dii.mn.gov Electrical Permit Permit Number: ELE2408-13161 Permit Information as of 08/29/24 Structure Type: One -Family Home I New Home Permit Status: Issued Site County: Washington County Issued Date: 08/29/24 Site Address: 15405 57th St N, Oak Park Heights, MN 55082 Expiration Date: 08/29/25 Fees Paid: $208.00 Permit Applicant Information Chris Hays Mobile: (651) 775-4971 Hays Remodeling Email: chrishays21@yahoo.com 6331 St Croix Trail N, Stillwater, MN 55082 Contracted Electrical Inspector's Information Name: Donald Edel Phone: (507) 210-8233 Don Edel Inspections LLC Email Address: mailto: d on.edel. i nsoecti ores@a mai I.com Project Information Electrical Utility: Xcel Energy, Inc. Phone: Email: bclmn@xcelenergy.com Rough -In Inspection Required: No Number of Inspections Requested: 3 Directions to Job Site: Corner of pellet Ave and 57th Street N Project Description: New 200 amp service 200 amp, 42 circuit panel, might need sub panel also A rough -in inspection is required before any wiring is concealed by insulation, wall covering, ceiling cover, trench backfill, etc. If wiring is concealed before inspection, the person responsible for concealing the wiring must cover the cost associated with uncovering and replacing the covering material. The installer must notify the inspector for final inspection when the wiring is complete and before the wiring is utilized and the space is occupied. Print Date: 08/29/2024 DEPARTMENT OF J LABOR AND INDUSTRY Inspection Report Project Name: New 200 amp service Permit Number: ELE2408-13161 Project location/address: 15405 57th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: Chris Hays Inspection Type: Partial Final Phone: (651) 775-4971 Result: Pass with Conditions Inspector Report new service inspection for utility (partial final) (the (service / emergency) disconnect needs the neutral and grounding electrode to be bonded) (the service / emergency disconnect needs to be labeled) (an intersystem ground bar is required at the service) NEC 250.94, An intersystem bonding termination (IBT) for connecting intersystem bonding conductors shall be provided external to enclosures at the service equipment or metering equipment enclosure and at the disconnecting means for any additional buildings or structures that are supplied by a feeder or branch circuit. MN STATUTE 32613.36, Correct the noted deficiencies. Return a signed copy of the Inspection Report to the inspector when the corrections are complete but no later than 14 days from the date of issuance unless otherwise instructed by the inspector. NEC 230.85 Each dwelling must have an outdoor readily accessible emergency disconnect installed on or within 50 feet of and visible from the dwelling. The emergency disconnect could be a service disconnect for the dwelling or it could be a disconnect supplied by the serving utility. If the disconnect is the service disconnect, it must be labeled as the "EMERGENCY DISCONNECT- SERVICE DISCONNECT". If the disconnect is provided by the serving utility, and is not the service disconnect, the disconnect must be labeled "EMERGENCY DISCONNECT - NOT SERVICE EQUIPMENT". The marking must be located on the outside front of the disconnect enclosure with red background and white text. The letters are to be at least 1 /2 inch high. NEC 250.28, The main bonding jumper (generally the green bonding screw or strap provided by the panel manufacturer) shall be installed in the main service panel. Inspected By: Donald Edel Phone: (507) 210-8233 Email: don.edet.inspections@gmai1.com Date:8/30/2024 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dii.mn.gov MDEPARTMENT OF U LABOR AND INDUSTRY Inspection Report Project Name: New 200 amp service Permit Number: ELE2408-13161 Project location/address: 15405 57th St N, Oak Park Heights, Washington County, MN, 55082 Applicant: Chris Hays Inspection Type: Final Phone: (651) 775-4971 Result: Pass with Conditions Inspector Report 200 amp, 42 circuit panel / sub panel (final) (need to add 1-extra garage receptacle for a car bay) MN STATUTE 326B.36, Correct the noted deficiencies. Return a signed copy of the Inspection Report to the inspector when the corrections are complete but no later than 14 days from the date of issuance unless otherwise instructed by the inspector. NEC 210.52, In attached garage and in detached garage with electric power, at least one receptacle outlet shall be installed for and in each vehicle bay within 5 1/2-feet above the floor. Inspected By: Donald Ede[ Phone: (507) 210-8233 Email: don.edet.inspections@gmail.com Date: 11 /14/2024 443 Lafayette Road N., St. Paul, MN 55155 1 (651) 284-5005 1 www.dli.mn.gov