Loading...
HomeMy WebLinkAboutPL 2025-00009 Plumbing Permit & Plan SetCITY OF OAK PARK HEIGHTS 14168 OAK PARK BLVI)t N. OAK PARK HEIGHTS, MN 55082- (651) 351-1661 FAX: (651) 439-0574 ADDRESS 5885 MEMORIAL AVE N PIN 06.029.20.12.0020 LEGAL DESC STILLWATER MOTORS ADDITION LOT 01 BLOCK 01 PERMIT TYPE PLUMBING PROPERTY TYPE COMMERCIAL CONSTRUCTION TYPE NEW CONSTRUCTION 1111111111111111111111 �I�ISSUED: 04/23/2025 Permit #: 2025-00009 VALUATION : $ 13,000.00 NOTE: CONSTRUCT CITY WELL PUMP HOUSE PER APPROVED PLANS. MUST COMPLY WITH ALL APPLICABLE CONSTRUCTION CODES, AS ADOPTED BY THE CITY OF OAK PARK HEIGHTS, CITY ZONING ORDINANCES, AND ANY OTHER RELATED AGREEMENTS BETWEEN APPLICANT & CITY. SPECIAL INSPECTOR REPORTS SHALL BE PROVIDED TO THE CITY BLDG DEPT. FEES WAIVED. PASS-THRU FEES PAID BY CITY OF OPH. VALUE OF PLUMBING 13000 WATER METER FEE 0 APPLICANT STEINKRAUS PLUMIBNG 7160 MADISON AVE W GOLDEN VALLEY, MN 55427- (952) 361-0128 OWNER CITY OF OAK PARK HEIGHTS 14168 OAK PARK BLVD N OAK PARK HEIGHTS, MN 55082- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to: (1) the conditions of this permit; (2) the approval plans and specifications; (3) the applicable city approvals, Ordinances, and Codes; and, (4) the State Buildin€ Code. This permit is for only the work described, and does not grant permission for additional or related work which requires separate permits. This permit will expire and becomf null and void if work is not started within 180 days, or if wort is suspended or abandoned for a period of 180 days any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformanc with the Minnesota State Building Code. PLUMBING -COMMERCIAL 0.00 PLUMBING STATE SURCHARGE COMMERCIAI 6.50 WATER METER 0.00 TOTAL 6.50 Payment(s) CHECK 71693 6.50 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY OF OAK PARK HEIGHTS PERMIT NO.: 2025-00009 14168 OAK PARK BLVEt N. DATE ISSUED: 04/23/2025 OAK PARK HEIGHTS, MN 55082- (651) 351-1661 FAX: (651) 439-0574 ADDRESS 5885 MEMORIAL AVE N PERMIT APPLICANT: PIN 06.029.20.12.0020 STEINKRAUS PLUMIBNG LEGAL DESC STILLWATER MOTORS ADDITION 7160 MADISON AVE W LOT 01 BLOCK 01 GOLDEN VALLEY, MN 55427- PERMIT TYPE PLUMBING PROPERTY TYPE : COMMERCIAL (952) 361-0128 CONSTRUCTION TYPE : NEW CONSTRUCTION VALUATION : $ 13,000.00 CONSTRUCT CITY WELL PUMP HOUSE PER APPROVED PLANS. MUST COMPLY WITH ALL APPLICABLE CONSTRUCTION CODES, AS ADOPTED BY THE CITY OF OAK PARK HEIGHTS, CITY ZONING ORDINANCES, AND ANY OTHER RELATED AGREEMENTS BETWEEN APPLICANT & CITY. SPECIAL INSPECTOR REPORTS SHALL BE PROVIDED TO THE CITY BLDG DEPT. FEES WAIVED. PASS-THRU FEES PAID BY CITY OF OPH. BUILDING INSPECTION RECORD 24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS. For Inspections Julie 651.351.1661 / jhultman@cityofoakparkheightscom INSPECTION TYPE DATE INSPECTOR PLUMBING -UNDERGROUND PLUMBING -ROUGH PLUMBING -FINAL INSPECTION COMMENTS: INSPECTION TYPE DATE INSPECTOR IN ACCORDANCE WITH CITY ORDINANCE, NEW OR SUBSTANTIALLY REMODELED BUILDINGS SHALL NOT BE OCCUPIED UNTIL ALL WORK HAS BEEN APPROVED, AND A CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED BY THE BUILDING DEPARTMENT. THIS CARD MUST BE POSTED AND VISIBLE AT ALL TIMES UNTIL WORK IS COMPLETE. ��DEPARTMENT OF LABOR AND INDUSTRY Division of Construction Codes and Licensing REPORT ON PLUMBING PLANS PROJECT: Oak Park Heights Pump Facility No. 3, 5885 Memorial Avenue N, Oak Park Heights, Washington County, Minnesota, Plan No. PB-R2404-0115 OWNERSHIP: City of Oak Park Heights, Andrew Kegley, Public Works Director, 14168 Oak Park Boulevard North, Oak Park Heights, MN 55082 SUBMITTER: Brian Lintgen, Stantec, 733 Marquette Avenue, Minneapolis, MN 55402 Plans Dated: February 9, 2024 Initial Date Received: April 9, 2024 Last Date Received: April 9, 2024 Date Approved: May 6, 2024 This review is limited to the provisions of the Minnesota Plumbing Code, Minnesota Rules, Chapter 4714 and assumes the data on which the design is based are correct. Approval is contingent upon meeting the requirements listed below. A copy of the approved plans and this report must he retained at the project location. INSPECTIONS: This project will be inspected by the local municipality. The contractor/installer must obtain all required inspection permits from the Oak Park Heights Building Official, Julie Hultman. All plumbing installations must be tested and inspected in accordance with the requirements of the Minnesota Plumbing Code. No plumbing work may be covered prior to inspection. REQUIREMENT(S): 1. All plumbing shall be installed in accordance with Chapter 4714. All pipe, fittings, traps, fixtures, materials, and devices shall be listed or labeled by a third -party listing agency and comply with the applicable standards referenced in the code (see Sections 301.2 and 1701.1). 2. The horizontal drainage piping must be installed with a uni form slope of at least 3 /4 inch per foot (see Section 708.1). Where municipal sewer depth, structural features, or building arrangement preclude this slope, a minimum slope of 118 inch per foot may be utilized for piping 4 inches and larger if approved by the authority having jurisdiction. 3. Verify that the dry wells receive only clearwater waste, are located at least 20 feet from the building and are an approved point of disposal by the Pollution Control Agency. 4. Fixture vents must rise within 45 degrees from the vertical at least 6 inches above the fixture flood level before offsetting horizontally or connecting to a branch vent (see Section 905.3). 5. If the water supply for the emergency eyewash extends inside the bowl below the spill line, the eyewash must discharge indirectly to the sanitary sewer. 6. Above -grade horizontal copper tubing 11/2-inch and smaller must be supported at least every 6 feet (see Table 313.3). 7. Each horizontal drain branch on or below the floor level of the building drain shall be provided with a cleanout at its upper terminal with the following exceptions (see Section 707.4): a. A cleanout is not required if the branch is less than five feet unless it serves sinks or urinals. b. A cleanout is not required on a drain that is 72 degrees or less from the vertical unless it serves kitchen sinks or urinals. 443 Lafayette Road N., St. Paul, MN 55155 s (651) 284-5005 • www.dii.mn.gov An Equal Opportunity Employer Oak Park Heights Pump Facility No. 3 Plumbing Plan No. PB-R2404-0115 Page 2 of 2 05/06/2024 PVC solvent weld joints must use ASTM F656 purple primer and ASTM D2564 cement per Section 705.6.2. 9. The plumbing system shall be tested in accordance with Sections 609.4 and 712.0. NOTE(S): 1. The scope of this project consists of constructing a new pump house. The plumbing installation includes a water heater, wall hydrants, floor drains, and two emergency eyewashes. 2. The building will be served by new sewer and water services. 3. The licensing authority may require additional plans, information and fee. Changes to the plumbing system may result. Any significant plumbing changes must be approved by this office prior to installation. Authorization may be withdrawn if installation does not begin within one year. Additional requirements may result from changed conditions or additional information. Approved: Bradle Williams, P.E. Y Public Health Engineer Plumbing Plan Review and Inspections Unit 651/284-5836 Bradley.Williams@state.mn.us cc: Brian Lintgen, Stantec City of Oak Park Heights, Andrew Kegley, Public Works Director Julie Hultman, Building Official MDH Wells File 0 o ;t`a ouo2 soot a8w_ r314 HW" 'C4CW \ 3/4" CW 112 HW" WATER HEATER 1"CW, SEE 3/4" CVJ 4" WASTE -INV ELEV = -2'-2" � PROCESS FOR 3/4" CW k 11 SAMPLE TAP CONNECTION WALL _ _ _ PENETRATION,TYP � ~ i EW-1 DRAIN HOLE, SEE CIVI WH-1 1/2 HW"- TYPICAL C HW & CW PLUMBING ISOMETRIC JIL PROVIDE VERTICAL 4" VENT UP THRU ROOF I I \ ��3• JIB PROVIDE VERTICAL I -3" 4" VENT UP THRU ROOF I 1 � I EW-1 I FCO PIPING THRU 4" FLOOR, TYPICAL I I \\\ FD2 I 3- 1" CW, SEE Cr FD-1 R CLEANOUT S PIPING FOR WASTE. COORDINATE )CATION WITH CIVIL- W&V PLUMBING ISOMETRIC - ROOM 101. 102 AND 103 TEMPERED WATER OUT TO EYEWASH STATIONS INSTANTANEOUS WATER HEATER. PROVIDE THERMOMETERS ON INLET AND OUTLET PIPING. 4" WASTE - INV ELEV = -2'-3" DRAIN HOLE, SEE CIVIL — — Wry �I VENT EW1 WITH PRES51 THRU GAUGE, TYPICAL ROOF F¢2 I CHEMICAL ROOM I 4" SAMPLE FCO SAMPLE COCK I 112" PVC PIPING —--------- ---- - - - - - - - - _L-L-� I I >< 314" I I FLUORIDE ROOM 102 * 7 FD-2 3/4' . i/2" HB-k FCO PUMP ROOM 103 UNDERFLOOR WASTE -----SAMM COCK PIPING, TYPICAL FO-1 b � e ♦n ° a MAINTAIN CODE REQUIRED CLEARANCES FOR ELECTICAL PANELS AND EQUIPMENT. COORDINATE WITH DMSION 26. A PLUMBING PLAN 0 1' 2' 9' u 4j v f I 'cn Qzu mi myaGi Q n o a o c oz 1 W C �o N _ - - SEE CIVIL - ° a d LL��o �- - - - - - - - - - w wgo d zZa i; =�oo- � U% ROOF �3a 3{ r•1 SURVEY DRAWN DESIGNED WK CHECKED ]IR -p.o'ED DCm 1'r`C1 10 17N201M �HE'r+:UUR M 101 E R (D MOTORIZED DAMPER, ATTIC FOR SLOPED ROOF CL SEE ARCHITECTURE D 11 AIR COOLED CONDENSING UNIT EXPANSION VALVE SERVICE VALVE L CRIER COOLING LIQUID LINE COIL SUCTION LINE NOTE: S VERIFY LINE SIZES wl EQUIPMENT SUPPLIER REFRIGERANT PIPING SCHEMATIC B NO SCALE CONCRETE eI EDA AWARD !NUMBER ED23CHI0G0094 SECTION - AIR HANDLER C 0 1'4" 2' c•.I MINIMUM CLEARANCE F_1 EXTEND REFRIGERANT PIPES TO ACI-1 PER DETAIL B REFRIGERANT - PIPES THRU WALL V-6" AFF ACC MOUNT 6 FOOT AFF. ROUTE CONDENSATE TO NEAREST FLOOR DRAIN. 01 Si TRANSITION AS REQUIRED -18 x 18 ALUMINUM EXHAUST DUCT DOWN. TERMINATE AT V-0" AFF WITH ALUMINUM EXPANDED METAL GRILLE 10x10 UP TO F-2 MOUNTED ON ROOF CURB L�j MOTORIZED DAMPER IN ATTIC J 1OX10 RIZED DAMPER c 1 0- INTERLOCK MOTORIZED DAMPER WITH F1� A - 24xZ4 CHEMICAL 1800 CFM ROOM 101 m PUMP NOTE 1: VERIFY ACCESS REQUIREMENTS ROOM FOR ALL EQUIPMENT WITH PROCESS ENGINEER. 103 NOTE 2: SEE ELECTRICAL DRAWINGS FOR UNIT HEATERS. FLUORIDE ROOM 102 10x10 UP, ROUT DUCT IN ATTIC. I O �I B -10x 10 � (CEILING)...d1d1�1 E d MAINTAIN CODE REQUIRED CLEARANCES FOR ELECTICAL PANELS AND EQUIPMENT. COORDINATE WITH DMSION 16 INTAKE LOUVER -SEE SHEET A101. PROVIDE SLEEVE WITH MOTORIZED DAMPER I I ! 1 I I I I I / I ff I I I I I I I i I f I I I I l I I I I I I I I ' _�THERMOSTATFOR ACI-1. MOUNT 5'-0" AFF I j i I I I I I I I I I I I I I I I I I I wu' W 4j c l�� r — • m 7 a z oE u an9 D � o s� ipppgppp5a DRY ;g$ u ll AN N 2EVISI0N DATE I BID SET 718124 SURVEY DRAWN DESIGNED RPK CHECKED ]LR APPROVED DO. PRO1 Na 17NMI38 SHEET NUMBER M 102