HomeMy WebLinkAboutME 2025-00261 ERVCITY OF OAK PARK HEIGHTS
14168 OAK PARK BLVII N.
OAK PARK HEIGHTS, MN 55082-
(651) 351-1661 FAX: (651) 439-0574
ADDRESS
15018 64TH ST N
PIN
34.030.20.32.0153
LEGAL DESC
MC KENTY'S ADD
LOT 16 BLOCK 2
PERMIT TYPE
MECHANICAL
PROPERTY TYPE
: RESIDENTIAL - OTHER THAN NEW
CONSTRUCTION TYPE
: REMODEL
III I III 11111111111111ISSUED: 11/10/2025
Permit #: 2025-00261
NOTE: WORK SCOPE: INSTALL NEW ERV & DUCTWORK TO BASEMENT. WORK SHALL BE PER MANUFACTURER
INSTALLATION GUIDE & COMPLY WITH MN CODE.
APPLICANT
CHRIS ANDREWS
15018 64TH ST N
OAK PARK HEIGHTS, MN 55082-
(651) 829-1851
OWNER
CHRIS ANDREWS
15018 64TH ST N
OAK PARK HEIGHTS, MN 55082-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed
according to: (1) the conditions of this permit; (2) the
approval plans and specifications; (3) the applicable city
approvals, Ordinances, and Codes; and, (4) the State Building
Code. This permit is for only the work described, and does
not grant permission for additional or related work which
requires separate permits. This permit will expire and become
null and void if work is not started within 180 days, or if work
is suspended or abandoned for a period of 180 days any time
after work has commenced. The applicant is responsible for
assuring all required inspections are requested in con Formanct
with the Minnesota State Building Code.
MECH-HVAC RESIDENTIAL 50.00
MECH-HVAC SURCHARGE -RESIDENTIAL 1.00
TOTAL 51.00
Payment(s)
CHECK 12929
51.00
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
ReN
The industry's most advanced residential fresh air system, created to
offer a universal platform specifically designed and improved to make
contractors life easier and more profitable while delivering constant
superior air quality.
• Thanks to the Virtuo Air TechnologyTIV, the airflow
calibration and auto -balancing are achieved quickly and
maintained throughout the life of the product
• Select the desired CFM (from 35 to 140 CFM) using the
proven integrated LCD screen
• Integrated electronic airflow measurement device with
real time LCD
■ Integrated diagnostic tool
• Equipped with PMSM ECM motors for energy efficient
operation
• Suspended installation (chains included)
OR
• Wall -mount installation (universal brackets included)
• installation with 2 brackets
• installation with 4 brackets
Controls -
ADVANCED BOOST
AUTOMATIC SPEED SELECTOR TOUCHSCREEN OVERRIDE
VC0184 VC0187 VC01" VC01e6
There are 4 optional main controls and 2 optional auxiliary
controls available. Refer to Wall Control specification sheet
for more information.
Fresh Air Systems - 140 CFM
ERV
Top ports: B160E75RT
# Side ports: B160E75RS
35 to 140 CFM @ 0.2 in. w.g:
35 to 133CFM @0.4in. w.g.
u�
��w►uv,�y�
HVI
Parts/Motor/ERV Core ■d�7ga� CERTIFIED
Visit www.broan-nutone.com for complete warranty text.
Unit Description
• SIRE of 75% at 32°F (65 CFM) and 63% at -1 YF (66 CFM)
• Ports size: 6"
■ Recirculation defrost
■ Corrosion resistant galvanized steel door and cabinet
• One-piece molded insulation shell, no air leakage
(expanded polystyrene; UL 94 HF-1 certified)
• Virtuo constant airflow and auto -balancing device
(patent pending)
• Motorized dampers (no additional backdraft dampers
required)
• No drain required
• Recirculate air within the dwelling with recirculation
mode using a main wall control
• 6' power cord
• Unit electrical characteristics:
120 volts, 60 Hz, 2.4 A, 163 W
Core
• Polypropylene crossflow core with polymeric membrane
and aluminum covers, impact resistant, non washable
• Dimensions: 12" x 12" x 9" (30.5 cm x 30.5 cm x 23 cm)
Fitt
• MERV 8 grade washable standard filter (included)
■ Optional MERV 13 grade filter part no. V24285'
Options
• Compatible with Tandem terminations (part no. VTYIK1
and V14695) (CFM output must meet application
requirements)
'Airflow performances associated with MERV 13 optional filter are not HVI certified. However, from tests performed by the manufacturer,
such performances are not affected by the use of this filter.
PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
6" Ports Dimensions (Top Ports)
Power cord
41/s" (10.48 cm)
311/4" (9.37 CM)
WAUSSI AIR
FROM BUILDING
(28.26 GM)
FRESH AIR
FROM OUTSIDE
4'/2" (11.43 cm)
T'
21'/2"
(54.61 cm)
CM)
REQUIRED
F DOOR :NANCEj�E
I I _ �ca:cnos E�716"
Terminals Draa (40.64 CM)
16'/a" (40.96 cM) 83/4" (47.63 cm) -
VK0126A L� 21" (53.34 cm) -
6" Ports Dimensions (Side Ports)
43/16"
(12.38 cm)
Power cord
Tm irtals real
161/s" (40.96 cm)
VK0125A
3" fs' (9.37 cM
Z8.26 cm)EXHAUST AIR
( FROM BUILUIHL
FRESH AIR
FROM OUTSIDE
43/16"
(12.38 cm)
B" (2
0.32 cm)
CLEARANCE REQUIF
IN FRONT OF DOOR
FOR MAINTENANCE
Latches
233/a" (59.37 cm)
•183/4" (47.63 cm)
�--16" (40.64 cm)
- 21 " (53.34 cm) -
Total assembled weight: approx 37 Ibs (16.8 kg) (core included)
Shipping weight: approx 44 Ibs (20 kg)
41/a" (10.48 CM)
3'1/16" (9.37 cm)
FRESH AIR 11'/e"
TO BUILDING
(28.26 cm)
EXHAUST AIR
TO OUTSIDE
4'/2" (11.43 cm)
11/4"(3.18 cm)
20'/16'
21 9/16'
(51.91 cm)
(54.77 cm)
I
SCREW
191/81,
FIXATION
(48.58 cm)
I
2Ei9---2
Total assembled weight: approx 37 Ibs (16.8 kg) (core included)
Shipping weight: approx 44 Ibs (20 kg)
T311/16" (9.37 cM)
---r-- 11 T/e"
FRESH AIR TO BUILDING � 28Z6 CM � )
EXHAUST AIR
TO OUTSIDE
43/16"
(12.38 cm) 11Y4"(3.18 CM)
j{- r 21 a/16'
Jf 43/16 (54.77 CM)
20'h6"
(51.91 CM)
SCREW (48.58 cm)
FIXATION
Defrost System - _ 7
HomeshieldTm Defrosting System
Defrost is activated at a
temperature of 230F and lower
as specified within the table. No
negative pressure is created by
air exhausted to the outdoors
since the air is recirculated into
the house, helping to prevent any
backdraft.
DISCRETION
OUTDOOR TEMPERATURE*
(Factory setting)
-5°C To -15°C
-15°C TO -27°C
-27°C AND LESS
23°F To 5°F
5°F TO -17°F
-1 PF AND LESS
CFM
AIR EXCHANGE
DEFROST
AIR EXCHANGE
DEFROST
AIR EXCHANGE
DEFROST
IN MINUTES
IN MINUTES
IN MINUTES
IN MINUTES
IN MINUTES
IN MINUTES
0 to 59
25
6
14
5
13
7
60 to 104
25
6
15
5
14
7
105 and more
15
6
10
5
19
7
*Outdoor temperature is read by a thermistor located inside the unit, next to
fresh air from outdoor port.
NOTE: There is a 10-minute additional defrost every 5 defrost cycles.
PLUS
OUTDOOR TEMPERATURE*
-5°C To -15°C
-15°C TO -27°C
-27°C AND LESS
23°F To 5°F
5°F TO -17*F
-17°F AND LESS
CFM
AIR EXCHANGE
DEFROST
AIR EXCHANGE
DEFROST
AIR
IICHANGE IN
DEFROST
IN MINUTES
IN MINUTES
IN MINUTES
IN MINUTES
MINUTES
IN MINUTES
0 to 59
25
7
14
7
12
8
60 to 104
25
7
1 15
7
13
8
105 and more
15
7
j 10
7
9
8
*Outdoor temperature is read by a thermistor located inside the unit, next to
fresh air from outdoor port.
NOTE: There is a 10-minute additional defrost every 5 defrost cycles.
Fan Curves with Virtue - --
Thanks to Virtuo Air TechnologyTM, no need to balance the unit manually. Both PMSM motors are controlled by an artificial
intelligence performing 120 readings per minute then processing this information to maintain the requested airflow.
For typical installation, Virtuo will ensure a balanced ventilation at every selected speed regardless of the weather
conditions, the type of connection, the variable speed furnace/AHU, the stack effect, the filter clogging and so on. This
results in peace of mind for installers and users knowing that the unit will always remain balanced and that it will maintain
its maximum heat/energy recovery efficiency.
STATIC
PRESSURE
(PA)
S AM
PRESSURE
(IN W.GJ
NET SUPPLY
AIRFLOW
(Us)
NET SUPPLY
AIRFLOW
(CFM)
G—
AIRFLOW
SUPPLY
(Us)
Gm.
AIRFLOW
SUPPLY
(CFM) I
GROSS
AIRROW
EXFIAUST
(US)
GROSs
AIRROW
EXHAUST
(CFM)
25
0-1
68
144
70
148
70
148
50
0.2
66
140
68
144
68
144
75
0.3
64
136
1 66
140
1 66
140
100
0.4
63
133
65
138
65
138
125
0.5
60
127
62
131
62
131
150
0.6
58
123
60
127
60
127
175
0.7
56
119
57
121
57
121
200
0.8
54
114
55
117
55
117
225
1 0-9
51
108
52
110
1 52
110
250
1 1-0
49
1 104
50
106
1 50
106
al
na
M
a
e w 70 30 u xi 80 90 .-- 110 ... . . 140 160
N.[ A,,n—(CFM)
Fan curve not certified by HVI.
Energy Performance
SUPPLY
TEMPERATURE
NE --AIRFLOW
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
ADJUSTED
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS*
LATENT
RECOVERY
MOISTURE
TRANSFER
°C
°F
L/S
CFM
HEATING
0
32
17
36
18
81 %
84%
88%
0.74
0
32
31
66
30
78%
81 %
84%
0.68
0
32
59
125
105
72%
1 78%
79%
0.59
-25
-13
31
66
68
63%
66%
81 %
0.63
35
95
17
36 1
21
-
-
77%
0.77
3.5
95
31
66
36
73%
0.69
35
95
59
125
112
-
63%
0.60
* Data not certified by HVI.
Requirements and Standards
• UL 1812 compliant (safety)
• Performance tested in accordance with CSA C439
Standard
• Compliant with Prop 65
■ Can be used to comply with California Title 24 2019
Part 6 Fault Indicator Display Requirements
• Can be used to earn WA energy code credits
Project: Remarks
Location:
Part no.-
Qty.:
Submitted bv: Date:
MGM* Mfi Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711
1108599E