Loading...
HomeMy WebLinkAbout2025-10-29 Nardini Fire - Suppression Chemical Inspection Report10/29/2025 NA ZIP SERVICE DATE: Report Cover Page BUILDING 5701 N St Croix Trail MN (651) 483-6631 Saint Paul MN 55126 9528874547 SERVICE TICKET: STREET CITY STATE 405 County Road E W Xcel Substation--allen King 56357 Nardini Fire Equipment PHONEBUILDING CONTACT Oak Park ST00419047 System Status:Pass Tag Color:Green Please see the attached reports. If there are any questions, please reach out to the above office. Download your Report at: Signed Signed Inspector:Building Contact: Title: 10/29/2025 10/29/2025 Scott Bazille NA https://customer.nardinifire.com 0001429023 Equipment Location : Frequency : :5537956357 Inspection Contract No. : Phone MUST HAVE A ZIEGLER PO 9528874547 5701 N St Croix Trail State : Address : 9528874575 : Phone State Address Generator Ziegler Power SystemsOwner Suppression Chemical Inspection Report Xcel Substation--allen King Zip : 8050 County Road 101 E. Property : : ST00419047 : Oak Park ShakopeeCity : Date : Service Ticket No. : 10/29/2025 MN Zip MN City Annual : : : PO No. : None found at time of inspection. DEFICIENCIES MONITORING & NOTIFICATION On/off Premises Monitoring Panel Condition Normal On Arrival?Yes Monitoring Agency Phone #0 Account Number Customer put on test Account Password NA Notifications Of Testing Completion Building Management Notified?Yes **Are There Any Monitoring Deficiencies To Report?No HAZARD DETAIL Type of System Dry Chemical If scale was used, enter last calibration date N/A If gauge was used, enter last calibration date N/A **Are record drawings available?N/A **Are flow calculations available?N/A **Sequence of Operation is posted?N/A **Proper warning signs in place?Yes **Any changes to hazard since system was installed?Unable to Confirm **Any changes to hazard since last inspection?Unable to Confirm **Piping is properly supported?Yes **Is piping proper type for the system?Yes Suppression Inspection Page 2 of 7 • 405 County Road E W • Saint Paul MN • 55126 ST00419047Service Ticket No. : **Are the fittings the proper type for the system?Yes **Nozzle(s) are properly oriented?Yes **Nozzle(s) are properly supported?Yes **Agent container(s) are properly supported?Yes **Discharge hose(s) are in good condition?N/A Date on discharge hoses N/A **Pilot hose(s) are in good condition?Yes Date on pilot hoses N/A **Did all initiating devices function?Yes **Did all manual releasing devices function?Yes **Did all maintenance switches function?Yes **Did all abort stations function?N/A **Did all release devices function?Yes **Did all notification devices function?Yes PANEL INFORMATION Information Type of transmission Relay Circuit Class Class B **Circuits are properly supervised?Yes Detection Setup Single Zone Method of Actuation Electric Type of releasing device Pyrochem Date of releasing device (if applicable)N/A Panel Information Panel Manufacturer Ansul Panel Model AutoPulse Z10 Is this the primary panel?Yes Over current protection type Circuit Breaker Over current size (amps)15 Breaker location Left of transfer switch Breaker number 13 **Dedicated circuit?Yes **Breaker marked?Yes Battery #1 Type Sealed Lead-Acid Rated volts 12 Rated amp hour 7 Manufacture Date 04/2025 **Leaks or corrosion?Visual Only **Connections tight?Pass **Did battery pass?Yes Suppression Inspection Page 3 of 7 • 405 County Road E W • Saint Paul MN • 55126 ST00419047Service Ticket No. : **Was battery replaced?No Battery #2 Type Sealed Lead-Acid Rated volts 12 Rated amp hour 7 Manufacture date 04/2025 **Leaks or corrosion?Visual Only **Connections tight?Pass **Did battery pass?Yes **Was battery replaced?No **Was battery size confirmed with drawings?No Drawings on Site System Function Summary & Test **Alarm Bells/Horns/Strobe evacuation alarms function properly?Yes **Loss of AC power is detected by the panel?Yes **Loss of secondary power is detected by the panel?Yes **Electrical opens in indicating circuits are detected?Yes **Electrical shorts in indicating circuits are detected?N/A **Panel was in good operational condition upon arrival?Yes "**Panel and surrounding equipment, conduit and wiring well secured and in good condition?"Yes **Are all troubleshooting LEDs operating correctly?Yes **Primary power supply operates properly under full load?Yes **Transient Suppressors visually inspected?N/A **Have all fuses been checked for rating and supervision?N/A **Are wires labeled and identified?N/A System Test & Inspection Control Panel Visual and Functional Lamps/LEDs Visual and Functional Primary Power Supply Visual and Functional Trouble Signals Visual and Functional Ancillary Devices Power Shutdown Present SEQUENCE OF OPERATIONS First Alarm Building Activation Alarm First Initiating device(s)Heat Detector Notification Horn/Storbe Second Notification Horn/Strobe outside area/room Time Delay No time delay Ancillary device shutdown Pass Second Alarm Suppression Inspection Page 4 of 7 • 405 County Road E W • Saint Paul MN • 55126 ST00419047Service Ticket No. : Building Activation N/A Second Initiating device(s)NA Notification N/A Second Notification N/A Time Delay N/A Ancillary device shutdown NA Panel Piezo with LEDs Release Device Location Below FACP Zone or Address Release ***Pass/Fail Pass Manual Release Building Activation Alarm Notification Horn/Strobe Second Notification Horn/Strobe outside area/room Time Delay No Time Delay Ancillary device shutdown Pass Panel Piezo with LEDs Discharge Alarm Building Activation Alarm Notification Horn/Strobe Second Notification Horn/Strobe outside area/room Panel Piezo with LEDs Ancillary device shutdown Pass Abort Are abort device(s) present?N/A Abort Type N/A ENCLOSURE INSPECTION **Does enclosure integrity apply?Yes **Visual condition appears to be okay?Yes **Proper door sweeps present?Yes **Proper seals on door jambs present?N/A **Proper astragal around double doors?N/A **Proper seal around windows?N/A **Wall partitions extend from floor slab to roof?N/A **Holes, cracks, or other openings in walls?N/A **Bottom of walls at floor properly sealed?N/A **If walls are porous, are they properly sealed?N/A **If dampers present, 100% air shutoff?Yes **Floor drains have proper liquid?N/A Suppression Inspection Page 5 of 7 • 405 County Road E W • Saint Paul MN • 55126 ST00419047Service Ticket No. : **Raceways appear to be properly sealed?Yes TANKS/ CYLINDERS Location Below Facp Manufacturer PyroChem Model #ABC Drychem Manufactured Date 07/2018 Type Steel Size NA Serial Number ATM736254 Agent Weight 35 Gross Weight 0 Fill Weight 35 Measured Weight 35 Gauge Pressure ( PSIG )350 Date Of Last Recharge 07/2018 Date Of Last 5-Year Inspection N/A Date of Last 5-Year Agent/ Fluid Swap N/A Date Of Last 6-Year Hydrostatic Test N/A Date Of Last 12-Year Hydrostatic Test N/A Measuring Device Used N/A **Did Tank/ Cylinder Pass Inspection yes Comments DEVICE INSPECTION REPORT Device Location Total Inspected:6 Zone or Address Pass / FailMakeType Total Passed:6Total Failed:0 Model Sensitivity Range Sensitivity Alarm Point Above Generator Engine PassHeat Detector Below Facp Maintenance Bypass PassNAMaintenance Switch NA Exterior Of Enclosure- 1 PassHorn / Strobe Exterior Of Enclosure- 2 PassHorn / Strobe Left Of Facp Pressure Switch PassTycoPressure Switch NA Manual Release PassAnsulElectrical Manual Release Ansul Suppression Inspection Page 6 of 7 • 405 County Road E W • Saint Paul MN • 55126 ST00419047Service Ticket No. : SIGNATURE This report was reviewed with:Nardini Fire Equipment : : NA DateDate Signature : 10/29/2025 : Scott Bazille 10/29/2025: :Technician Signature Print Name Suppression Inspection Page 7 of 7 • 405 County Road E W • Saint Paul MN • 55126