Loading...
HomeMy WebLinkAbout2026-01-08 PC Packet Enclosure PLANNING REPORT ENCLOSURE 3 TO: Jacob Rife FROM: Scott Richards DATE: December 31, 2025 RE: Oak Park Heights – Dave’s Hot Chicken – Planned Unit Development / Conditional Use Permit Amendment – 5910 Neal Avenue North TPC FILE: 236.02 – 23.09 BACKGROUND Polo Padilla of Fusion-AE representing MN Chicken LLC, owner of the property, has submitted an application to make exterior changes to the Taco John’s building at 5910 Neal Avenue North for use as a Dave’s Hot Chicken. The application consists of a request for a Planned Unit Development / Conditional Use Permit Amendment to allow for additional signage and Site Plan/Design Guidelines review. The property is zoned B-2 General Business District with a PUD Overlay. The site, with the former Kentucky Fried Chicken (now K&J Catering, 5920 Neal Avenue North) was first approved for rezoning, a final plat, and Planned Unit Development / Conditional Use Permits for fast foot restaurants by the City Council in November 2003. The site was rezoned to B-2 with the PUD Overlay with cross easements to allow for access, traffic circulation, and parking utilization between the two lots. EXHIBITS The review is based upon the following submittals: Exhibit 1: Project Narrative Exhibit 2: Site Location Map Exhibit 3: Title Sheet (1) Exhibit 4: Site Plan – (2) Exhibit 5: Exterior Elevation – (3) (East Façade Sign Plan) Exhibit 6: Exterior Elevation – (4) (North Façade Sign Plan) Exhibit 7: Exterior Elevation – (5) (West Façade Sign Plan) Exhibit 8: Exterior Elevation – (6) (South Façade Sign Plan) Exhibit 9: Face and Halo Lit Channel Letters on Backer Panel – (7) Exhibit 10: Face and Halo Lit Channel Letters on Backer Panel – (8) 2 Exhibit 11: Face and Halo Lit Cannel Logo – (9) Exhibit 12: Night Illumination – (10) Exhibit 13: Monument Replacement Faces – (11) Exhibit 14: Pylon Replacement Faces – (12) Exhibit 15: Demolition Floor Plan – (D1.0) Exhibit 16: Dimensioned Floor Plan – (A1.0) Exhibit 17: Exterior Elevations – (A2.0) Exhibit 18: Resolution No. 03-11-56 – Approved November 25, 2003 Exhibit 19: Planned Unit Development Permit – Issued January 15, 2004 PROJECT DESCRIPTION The project narrative is found as Exhibit 1. The introduction to the narrative that provides an overview is as follows: As one of the owners and franchisees of the planned Dave’s Hot Chicken in Oak Park Heights, I am requesting a variance to allow mural artwork throughout the exterior of our building located at 5910 Neal Avenue N. While the City’s Design Guidelines do not specifically reference murals, this design element is a central part of the Dave’s Hot Chicken brand and an important factor in creating the guest experience that our guests expect. Dave’s Hot Chicken restaurants nationwide feature mural artwork that reflects the brand’s energy, authenticity, and urban roots. These murals are not optional embellishments – they are an essential component of our franchise design standards. Without them, our building would not represent the nationally recognized Dave’s Hot Chicken identity. The approvals granted in 2003 for Taco’s John’s are still in effect for this site. The current application addresses the proposed signage as well as the Site Plan and Design Guidelines review. The signage package for this restaurant does not comply with the sign standards of the Zoning Ordinance and the building color/graphics are not compliant with the Design Guidelines. ISSUES ANALYSIS Comprehensive Plan. The property is designated as Commercial on the Proposed Land Use Map. The drive through restaurant is consistent with that land use designation. Zoning. The property is zoned B-2 General Business District with a PUD Overlay. A Planned Unit Development / Conditional Use Permit Amendment is required to allow the signage changes proposed. Design Standards/Site Plan review is also required. A variance from the Design Standards is required to approve the proposed façade color and graphics. Approvals granted in 2003 included the following: 3 1. Rezoning from Open Space Conservation (O) to General Business (B-2) with a PUD Overlay District. 2. Preliminary/final plat of “Oak Park Marketplace” for the 1.98-acre property for a two-lot commercial subdivision. 3. Conditional Use Permit (CUP) for two fast food restaurant buildings with drive- through windows. 4. CUP to allow a reduced parking requirement. 5. CUP to allow curb cuts greater than 24 feet in width. 6. General concept and general plan of development Planned Unit Development (PUD) approvals. 7. Site and Building Plan approval. The approvals have not been amended since granted in 2003. The Taco John’s has operated in that location since it opened that year. The KFC structure is now a catering business and the allowance for a drive through restaurant has expired. Signage. When the Taco John’s and KFC were approved in 2003, a Conditional Use Permit for signage was not required in that all signage met the requirements of the Zoning Ordinance. The subject site is in the Destination Highway Retail District which allows for additional signage from what is allowed in the B-2 District. Freestanding Pylon Sign. The freestanding pylon sign for the site will remain. The Applicant proposes utilizing both sign faces for Dave’s Hot Chicken. The subject site is in the Destination Highway Retail Highway District which allows for one freestanding pylon sign that does not exceed 200 square feet in area. The sign plan shows that the size of the signage is to be determined. The size of the signs shown are approximately 50 square feet each, consistent with the current sign faces. Freestanding Monument Sign. The existing freestanding monument sign shall remain, and the sign faces will be updated. The sign plan shows the proposed monument sign faces. Wall Signage. The Destination Retail Highway District allows for a total of three wall signs, each on separate facades. The proposed sign plan indicates two separate wall signs on the north and east elevations and one sign each on the south and west elevations for a total of six wall signs. A Conditional Use Permit is required to allow for the additional wall signs. Past precedence has allowed for Conditional Use Permit approval of a total of four wall signs per business, one on each façade. The most recent approval for a drive through restaurant was Popeye’s where one wall sign per façade was allowed for a total of four wall signs, and two signs could be placed on one of the facades. With the visibility of the site from Stillwater Blvd North / County Road 15, one wall sign per facade is thought to be adequate for the Dave’s Hot Chicken business. Total Allowable Wall Signage. The square footage of wall signage shall not exceed 500 square feet of wall signs for the site, and the signs cannot exceed 10 percent of the wall area, per façade. The proposed wall signs are as follows: 4 Sign Square Feet Total No. of Signs Total Square Feet East Elevation: 77 28 2 105 West Elevation: 58 1 58 North Elevation: 77 28 2 105 South Elevation: 28 1 28 TOTAL 296 6 296 As indicated, the wall signage should be limited to one per façade for a total of four wall signs. The Applicant could determine which sign to use on each façade, and two signs may be placed on one of the facades. At the time of sign permitting the Applicant shall provide the square footage of each of the facades to assure compliance with the 10 percent limit of signage. Directional Signage. The Applicant shall provide a plan for directional signage compliant with the requirements of Section 401.15.G of the Zoning Ordinance. Sign Illumination. The signs will be required to comply with the Zoning Ordinance lighting requirements. Staff will approve the lighting specifications for the signs at the time of permitting. The sign and order board lighting should be designed such that only the text and logo portions of the signs are to be lit at night. The sign background will need to be dark. Drive-Thru for Restaurants. Plans shall be provided for any proposed canopy structure and menu board for the order lane. The final plans for the directional signs, menu boards, canopies and associated lighting will be subject to review by the City. Access/Site Plan. There are no changes proposed for access or the layout of the site. The building footprint, parking layout, and circulation patterns for the drive through will not be altered. Parking. In 2003, a Conditional Use Permit was granted to allow for a reduction of required parking from 98 parking stalls to 79. This allowance is more in line with the current standards for parking that were approved in 2023. The parking requirement was 5 lowered by now requiring one space for each 100 square feet of gross floor area from one space for each 35 square feet for fast food and drive through restaurants. In that no changes are to be made to the site or to the building at this time, no further process is required. Grading/Drainage/Utilities. There are no site plan changes proposed that will require the City Engineer’s review. Lighting Plans. Fixtures. The Applicant has indicated that the exterior light fixtures will be replaced. A lighting fixture plan will be required for review by the City. All light fixtures shall be full cut off and consistent with Section 401.15.B.7 of the Zoning Ordinance as it relates to lighting requirements. Photometrics. A photometric plan will be required with submittal of the fixture plan. The light intensity is required to be less than one-foot candle at the centerline of adjacent streets and 0.4-foot candles at the property line. Building Lighting. Building color wraps or LED and neon strip lighting is not allowed. Hours. Outdoor lighting for parking lots shall be turned off one hour after closing, except for approved security lighting. Landscaping. No changes are proposed to the existing landscaping. Any landscape changes are subject to City Arborist review and approval. Mechanical Screening. No changes are proposed at this time to exterior mechanical equipment. Any exterior mechanical equipment, either on the roof or ground mounted, is required to be screened in accordance with Section 401.15.E.10.e. of the Zoning Ordinance. Trash/Recycling Storage. There is a trash and recycling enclosure at the back of the building. Design Guidelines. Architectural Guidelines. Façade Treatments The proposed building will not be altered except that the plans show the building will be painted white with color mural graphics. Red awnings will be placed over the windows. Ground Level Expression This is a one-story building with a raised roof feature. 6 Transparency The building transparency will not be altered. The existing window and door placement will remain. Entries The customer entry for the building will not be altered. Roof Design The roofline is broken by a varying roof heights. Building Colors The Design Guidelines indicate the following: Building colors should accent, blend with, or complement the surroundings. Principal building colors should generally consist of neutral, or muted colors with low reflectance. “Warm-toned” colors are encouraged because of their year- round appeal. No more than three principal colors should be used on a façade or individual storefront. Bright or primary colors are acceptable when determined through the design and review process to be appropriate for the site and building use. The proposed building color and graphics is a significant departure from the Design Guidelines. The Planning Commission should discuss whether the white base and bright color mural graphics are acceptable for the site and the building. A variance from the Design Guidelines would be required if the colors are found to be acceptable. Building Materials The building materials will remain the same, but the entire building will be painted white, covering the original brick and painted surfaces. Franchise Architecture The building is a franchise design. The Planning Commission should comment whether the colors are compatible with the Design Guidelines. Site Design Guidelines The site is not being altered with this proposal. Conditional Use Permit Review Criteria. The conditional use permit criteria, found in Section 401.03.A.7 of the Zoning Ordinance, are found as follows: 1. Relationship to the specific policies and provisions of the municipal comprehensive plan. 2. The conformity with present and future land uses in the area. 3. The environmental issues and geographic area involved. 7 4. Whether the use will tend to or actually depreciate the area in which it is proposed. 5. The impact on character of the surrounding area. 6. The demonstrated need for such use. 7. Traffic generation by the use in relation to capabilities of streets serving the property. 8. The impact upon existing public services and facilities including parks, schools, streets, and utilities, and the City’s service capacity. 9. The proposed use’s conformity with all performance standards contained herein (i.e., parking, loading, noise, etc.). Comment: The Planning Commission should comment if any of these criteria will be at odds with the Conditional Use Permit proposed for the site. It is recommended that the number of wall signs be limited through the approved conditions. CONCLUSION / RECOMMENDATION Upon review of the requests for a Planned Unit Development / Conditional Use Permit Amendment to allow additional signage and a variance from the Design Guidelines for building color and graphics for a Dave’s Hot Chicken at 5910 Neal Avenue North, City Staff would recommend the project with the conditions as follows: 1. Wall signage should be limited to one per façade for a total of four wall signs. The Applicant may determine which sign to use on each façade, and two signs may be placed on one of the facades. At the time of sign permitting the Applicant shall provide the square footage of each of the facades to assure compliance with the 10 percent limit of signage. 2. The Applicant shall provide a plan for directional signs, any canopy structures, and menu boards compliant with the requirements of Section 401.15.G of the Zoning Ordinance. Any directional signage shall be subject to review of the City and can only include the name and logo of the business. 3. All signage shall be subject to final review and approval of City Staff for conformance with Zoning Ordinance standards. The sign lighting should be designed such that only the text and logo portions of the signs are lit at night. Staff shall approve the lighting specifications for signs at the time of permitting. 4. All lighting fixtures shall be full cut off and installed in compliance with the lighting standards of the Zoning Ordinance. A photometric plan shall be provided for review and approval by City Staff. Building color wraps or LED and neon strip lighting is not allowed. 5. The outdoor lighting shall be turned off one hour after closing, except for approved security lighting. 6. Any changes to trees or landscaping shall be subject to City Arborist review and approval. 8 7. Mechanical equipment that is located on the roof or visible from street level or from neighborhood properties shall be screened with materials that blend harmoniously with the building façade materials. 8. All storage of trash and recycling shall be totally within the trash enclosure. 9. The Planning Commission should review the proposed building colors and use of building material selection and colors. 10. A bike rack shall be identified on the site plan and placed on site. pc: Julie Hultman Minnesota Chicken, LLC – Variance Application 1 | Page MINNESOTA CHICKEN, LLC dba DAVE’S HOT CHICKEN 2523 Bridle Creek Trail Chanhassen, MN 55317 www.daveshotchicken.com Alex Humphries Owner alex@mnchicken.com direct phone (202) 841-3225 S EPTEMBER 26TH, 2025 VIA ELECTRONIC MAIL Planning Commission and City Council City of Oak Park Heights 14168 Oak Park Blvd N. Oak Park Heights, MN 55082 Attn: Julie Hultman Re: VARIANCE REQUEST – BRAND MURAL ARTWORK ON BUILDING EXTERIOR Dear Planning Commission and City Council, As one of the owners and franchisees of the planned Dave’s Hot Chicken in Oak Park Heights, I am requesting a variance to allow mural artwork throughout the exterior of our building located at 5910 Neal Ave N. While the City’s Design Guidelines do not specifically reference murals, this design element is a central part of the Dave’s Hot Chicken brand and an important factor in creating the guest experience that our guests expect. Dave’s Hot Chicken restaurants nationwide feature mural artwork that reflects the brand’s energy, authenticity, and urban roots. These murals are not optional embellishments—they are an essential component of our franchise design standards. Without them, our building would not represent the nationally recognized Dave’s Hot Chicken identity. In support of this request, I wish to address the required variance findings: a. Special Circumstances / Unique Conditions The Design Guidelines do not contemplate mural artwork as a façade treatment. Dave’s Hot Chicken requires murals as part of its national brand design. Without this variance, we are deprived of a reasonable use of the building that is necessary to maintain brand consistency and deliver the guest experience expected across all Dave’s Hot Chicken restaurants. b. No Detriment to Public Health, Safety, or Welfare The mural will not harm public health, safety, or welfare. Instead, it will improve the visual environment, deter graffiti by providing intentional and managed artwork, and create a safer, more vibrant pedestrian experience. c.Addressing Inequities / Hardship While this is not a topographical or vegetation-related hardship, the inequity arises from a design limitation: other Dave’s Hot Chicken locations across the country are able to express the brand through murals, whereas strict application of the Guidelines here would uniquely prevent it. This creates a disproportionate restriction on the reasonable use of our building compared to other franchise properties. EXHIBIT 1 Minnesota Chicken, LLC – Variance Application 2 | Page d. Not Based on Economic Difficulties This request is not made out of financial hardship. The hardship arises from the absence of mural provisions in the Design Guidelines, not from economic constraints. That said, as a new business in Minnesota, it is important for us to establish brand visibility and guest recognition in what is becoming a highly competitive chicken restaurant space. With Chick- fil-A opening a new location in Stillwater next year, maintaining Dave’s Hot Chicken’s national brand standards — including our signature mural artwork — is critical for differentiation and long-term success. Dave’s also has national data showing that locations incorporating mural artwork see, on average, a 20% lift in sales compared to those that do not. While this is not the basis for the variance, it demonstrates how murals strengthen viability, support surrounding businesses, and contribute to the City’s tax base. e. Hardship Not Self-Created The hardship is not the result of any action by me as the planned building tenant. It arises entirely from the absence of provisions in the Guidelines for mural artwork as a design element. f. No Change to the Design Guidelines Process Approval of this variance does not alter the process or scope of the Design Guidelines. It simply allows for a unique and brand-required design treatment within the existing framework. While the murals are brand-specific, they provide value beyond the business itself by: • Enhancing the community’s visual environment with high-quality, professionally executed artwork. • Creating a unique destination that attracts guests from across the region, benefiting the broader Oak Park Heights economy. • Demonstrating Oak Park Heights’ ability to support nationally recognized concepts while still encouraging creative, distinctive design. Dave’s Hot Chicken murals are a fundamental expression of our brand, and their inclusion is critical to delivering the authentic guest experience our guests expect. Approving this variance will not only respect our franchise standards but also advance the City’s vision for engaging, high-quality commercial development. I respectfully request approval of this variance so that our planned Oak Park Heights location can fully reflect the Dave’s Hot Chicken brand while contributing positively to the community’s character and streetscape. Thank you for your time and consideration. Sincerely, Alex Humphries Owner Minnesota Chicken, LLC dba DAVE’S HOT CHICKEN EXHIBIT 2 EXHIBIT 3 EXHIBIT 4 EXHIBIT 5 EXHIBIT 6 EXHIBIT 7 EXHIBIT 8 EXHIBIT 9 EXHIBIT 10 EXHIBIT 11 EXHIBIT 12 EXHIBIT 13 EXHIBIT 14 1DEMOLITION FLOOR PLAN 1/4"=1'-0" SHEET TITLE: SHEET NUMBER: DEMOLITION FLOOR PLAN D1.0 DATE DESCRIPTION CLIENT: Minnesota Chicken, LLC 2523 Bridle Creek Trail Chanhassen, MN 55317 202.841.3225 PROJECT NUMBER: PRELIMINARY FOR REVIEW ONLY THESE DOCUMENTS ARE FOR DESIGN REVIEW AND NOT INTENDED FOR BIDDING, CONSTRUCTION, OR PERMIT PURPOSES. DHC25015 DA V E ' S H O T C H I C K E N OA K H E I G H T S , M N - T F O 59 1 0 N E A L A V E N . OA K P A R K H E I G H T S , M N 5 5 0 8 2 Mi n n e s o t a C h i c k e n , L L C 25 2 3 B r i d l e C r e e k T r a i l Ch a n h a s s e n , M N 5 5 3 1 7 DATE DESCRIPTIONDATEDESCRIPTION 10.29.25 6201 CAMPUS CIRCLE DRIVE E IRVING, TEXAS 75063 TEL: 972.870.1288 ARCHITECT: WWW.IDSTUDIO4.COM E-MAIL rridge@fusion-ae.com RUSTY ALLAN RIDGE, AIA N PLAN NORTH TRUE NORTH N GENERAL DEMOLITION NOTES KEY NOTES: 1DEMOLITION REFLECTED CEILING PLAN 1/4"=1'-0" EXHIBIT15 PREP STORAGE RESTROOM RESTROOM FREEZERCOOLER CLEANING OFFICE SERVICE DINING CLEANING STORAGE VESTIBULE SHEET TITLE: SHEET NUMBER: DIMENSIONED FLOOR PLAN A1.0 DATE DESCRIPTION CLIENT: Minnesota Chicken, LLC 2523 Bridle Creek Trail Chanhassen, MN 55317 202.841.3225 PROJECT NUMBER: PRELIMINARY FOR REVIEW ONLY THESE DOCUMENTS ARE FOR DESIGN REVIEW AND NOT INTENDED FOR BIDDING, CONSTRUCTION, OR PERMIT PURPOSES. DHC25015 DA V E ' S H O T C H I C K E N OA K H E I G H T S , M N - T F O 59 1 0 N E A L A V E N . OA K P A R K H E I G H T S , M N 5 5 0 8 2 Mi n n e s o t a C h i c k e n , L L C 25 2 3 B r i d l e C r e e k T r a i l Ch a n h a s s e n , M N 5 5 3 1 7 DATE DESCRIPTIONDATEDESCRIPTION 10.29.25 6201 CAMPUS CIRCLE DRIVE E IRVING, TEXAS 75063 TEL: 972.870.1288 ARCHITECT: WWW.IDSTUDIO4.COM E-MAIL rridge@fusion-ae.com RUSTY ALLAN RIDGE, AIA 2DIMENSIONED FLOOR PLAN 1/4"=1'-0" GENERAL NOTES WALL LEGEND N PLAN NORTH TRUE NORTH N 1DIMENSIONED COUNTERTOP PLAN AT POS 1/2"=1'-0" N PLAN NORTH TRUE NORTH N EXHIBIT16 EXHIBIT17 RESOLUTION NO. 03-11-56 CITY COUNCIL CITY OF OAK PARK HEIGHTS WASHINGTON COUNTY, MINNESOTA A RESOLUTION ESTABLISHING FINDINGS OF FACT AND RESOLUTION OF THE CITY COUNCIL THAT THE REQUEST BY TACO JOHN'S/STEAK ESCAPE AND KFC/A & W FOR REZONING, PRELIMINARY/FINAL PLAT, CONDITIONAL USE PERMITS, PUD APPROVALS, AND SITE AND BillLDING PLAN APPROVAL LOCATED EAST OF MINNESOTA HIGHWAY 5 ON NEAL A VENUE BE APPROVED WITH CONDITIONS WHEREAS, the City of Oak Park Heights has received a request from Taco John's/Steak Escape and KFC/A & W for the following : 1.Rezoning from Open Space Conservation (0) to General Business (B-2) with a PUD Overlay District. 2.Preliminary/final plat of "Oak Park Marketplace" for the 1.98-acre property for a two-lot commercial subdivision. 3.Conditional Use Permit (CUP) for two fast food restaurant buildings with drive-through windows 4.CUP to allow a reduced parking requirement. 5.CUP to allow curb cuts greater than 24 feet in width. 6.General concept and general plan of development Planned Unit Development (PUD) approvals. 7.Site and Building Plan approval for property located east of Minnesota Highway 5 on Neal Avenue and after having conducted a public hearing relative thereto, the Planning Commission of Oak Park Heights recommended the application be approved with conditions. The City Council makes the following findings of fact and resolution: follows, to wit: 1.The real property affected by said application is legally described as SEE ATTACHMENT A and 2.The applicant has submitted an application and supporting documentation to the Community Development Department consisting of the following items: SEE ATTACHMENT B EXHIBIT 18 EXHIBIT 19