HomeMy WebLinkAbout2010-01-26 Summit Fire Protection Report �XMNIII FIRE PRb EC'TIO f 575 MINNEHAHAAVE. W • ST. PAUL, 10103 • (651) 251 -1880 3026 AVE. 10 ROCHESTER, MN 55901 • (507) 280 -0622 418 GREAT OAK DR., WAITE PARK, MN 56387 • (320) 257 -6390 7601 . IBERFY FORTY, IA 52317 • (319) 665 -4330 4208 ENTERPRISE CIRCLE • DULUTH, MN 55811 • (218) 740 -4412 SHEET 1 OF 2 - Use separate sheet for each building inspection _. REPORT OF INSPEC' °ION MINNESOTA LICENSE NO. C0075 JOB NUMBER INSPECTION NAME S71 LJ-W i ;C . Z Q+l� OCATI6%o S9r+7� STREET S 86:,"2 0 190el Ju,£ , INSPECT / 0 2 CITY & STATE (X 1' ?Afe 1Z DATE (o – /O Owner's Section (to be answered by Owner or Occupant) 1 A. Explain any occupancy hazard changes since the previous inspection: 1 B. Describe fire protection modifications made since last inspection: C. Describe any fires since last inspection: -- i D. When was the system piping last checked for stoppage, corrosion of foreign material? E. When was the dry- piping system last checked for proper pitch? alves adequat ly pro ted from freezing? Sin �` Title Date Inspector 's ec . responses reference current inspection) NA =NOT APPLICABLE 1. General a. Is the building occupied? 5$es ❑ No b. Are all systems in service? ORes ❑ No c. Is there a minimum of 18 in. (457 mm) clearance between the top of the storage and the sprinkler deflectors? O'es ❑ No d. Does all electrical heat tape appear to be satisfactory? ❑Yes ❑ No 04VA � e. Does the hand hose or standpipe on the sprinkler system(s) appear to be satisfactory? ❑Yes ❑ No ONA 2. Control Valves (See Item 15.) a. Are all sprinkler system control valves and all otheres in the appropriate open or closed p ition? ['Yes ❑ No b. Are all control valves in the open position locked, or equipped with a tamper switch ?_ [BYes, ❑ No .3. Tanks, Pumps, Fire Department Connections a. When was fire pump last tested for performance? VI b. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? ❑Yes ❑ No LA NA c. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight? JVes ❑ No ❑ NA Are they accessible and visible? ZRes ❑ No ❑ NA 4. Wet Systems a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position? ❑Yes ❑ No C ' A b. Have antifreeze system solut�opseen tested? ❑Yes ❑ No ,9NA c. What temp is antifreeze? //�"'�� d. In areas protected b wet system(s), does the buildin appear t e properly heated in all areas, including blind attics and perimeter areas where accessible ?s ❑ No ❑ NA 5. Dry System (See 7tems 11 to 13) a. Are dry valve(s) in service? ❑Yes ❑ No ❑ NA b. Are the air pressures and fflairni at levels in accordance with the manufacturer's instructions? ❑Yes ❑ No ❑ NA c. Has the operation of the g upplies been tested? ❑Yes ❑ No ❑ NA Are they in service? ❑Yes ❑ No ❑ NA d. Were low points drained ction? ❑Yes ❑ No ❑ NA How many? e. Did quick - opening devic actorily? ❑Yes ❑ No ❑ NA f. Did the dry valve(s) trip ring the trip pressure test? ❑Yes ❑ No ❑ NA g. Did the heating equipment in the dry-pipe valve room(s) operate at time of inspection ? ❑Yes ❑ No ❑ NA 6. Special Systems (See Item 14.) a. Did the deluge or pre ac ' v ves operate properly during testing? ❑Yes ❑ No ❑ NA b. Did the heat - respons' e i s operate properly during testing? ❑Yes ❑ No ❑NA c. Did supervisory dev ' a during testing? ❑Yes ❑ No ❑ NA d. Did flow for kitchen o s st m shut off gas or electric? ❑Yes ❑ No ❑ NA 7. Alarms a. Did water motor(s) and gong(s) test satisfa torily? ❑Yes ❑ No 6 b. Did electric alarm(s) test satisfactorily? es ❑ No ❑ NA c. Did supervisory alarm service test satisfactorily? CRes ❑ No ❑ NA �l d. Did tamper switches test satisfactorily? ❑Yes ❑ No A 8. Sprinklers a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge? des ❑ No b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) &Yes ❑No c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing), pies ❑ No d. Is stock of spare spri available? OR'es ❑ No e. Does the exterior dition f sprinkler system appear to be satisfactory? Yes ❑ No f. Are sprinkler proper to erature rating for their locations? Wes ❑ No g. Are any s nkler heads oida repall list? ❑Yes [ Mo Signatur f °�C —7 72 Date: 1 o� G /O V UMMIT FIRE PROTECTION 5115 Minnehaha Ave. W. St. Paul, MN 55103 •'551- 251 -1880 3026 40th Ave. NW • Rochester, MN 55901 507- 280 -0622 NJ0 Great Oak Dr. • Waite Park, MN 56387 • 320 - 257 -6390 760 Liberty Way • North Liberty, IA 52317 319- 665 -4330 8 Enterprise Circle • Duluth, MN 55811 • 218- 740 -4412 ' SHEET 2 OF 2 - Use separate sheet for each system inspection Type of System Inspection Name _ Y"il7w L How Many? Inspection Work Order What Size? A.) U a Flow Switch or Alarm Check with Pressure Switch 9. Date dry -pipe valve trip tested (control valve partially open) (see Trip Test Table which follows) 10. Date dry-pipe valve trip tested (control valve fully open) / (see Trip Test Table which follows) 11. Date quick - opening device tested (� (see Trip Test Table which follows) DRY VALVE TRIP TEST TABLE Q.O.D. MAKE I MODEL I S�E RiAi NO MAKE I MODEL I SERIAL NO. DRY PIPE Time to Trip Trip Point Ti Water Reached Alarm Operated OPERATING Thru Test Pipe Water Pressure Au sure me Ai Pressure I Test Outlet Properly TEST Min. Sec. PSI /_ PSI PSI Min. Sec. Yes No O.O.D. (\ 12.f Date deluge or preaction valve tested l �l (see Trip Test Table which follows) TRIP TEST TABLE Operation ❑ Pneumatic ❑ Elects .hc Piping Supervised ❑ Yes ❑ No `� Detecting Media Supervised ❑ Yes ❑ No DELUGE 8, I Does valve operate from the manual trip and/or remote control tions7 El Yes El No PREACTION VALVES I Is there an accessible facility in each circ ' testing? ❑Yes No Method of Testing Circuits: MAKE MODEL ces Each Circuit Operate Does Each Circuit M aximum Time to supervision Loss Alarm? Operate Valve Release? I Operate Release? ❑ Yes ❑ No ❑ Yes ❑ No ( ❑ Yes ❑ No 13. See Control Valve Maintenance Table CONTROL VALVE MAINTENANCE TABLE ' CONTROL VALVES NUMBER SIZE & TYPE OPEN SECURED CLOSED SIGNS EXPLAIN ABNORMAL CONDITIONS City Connection Control Valve Joclrey Control Valve Pump Control Valves Additional Pump Control Valves Test Header Sectional Control Valves System Control Valves C:� t+ 8 r f� J�5 S Other Control Valves / 1 Kitchen Control Valves E Water Flow Test at Sprinld Water Supply Source:. City ✓ Well .Tank Pump DATE TEST PIPE LOCATION SIZE OF TEST PIPE STATIC PEESSURE I RESIDUAL (FLOW) DIFFE RF.NTiAL f PRE TEST POST TEST PRESSURE Last Water Flow Test t 1 J g 11 ls_ u -71 Tr/ � Y O This Water Flow Test 2 14.. Explain any "No" answers and comments: Print Na P �" �y i / Signatu f .� JCa1 Date t -