Loading...
HomeMy WebLinkAbout1999-12-07 Fire Inspection Report - Commemorative Imports • -4110 Inspection Report r t. °_ Bayport Fire Department • 301 2nd Avenue North • Bayport, MN 55003 • (612) 439 -6992 Date Time Property Address - Phone / -/o 7/ 99 /6. olc 590 l <>Mkllet 4,..4 41, Or 115 _ '739 - cn - Building/Property Name Correspondence To (- M °° Q. ov - 4.A. , Ae. Ti //I 7 s Occupancy Class I Const. Type Const. Year No. of Stories Sq. Ft. Floor No. of Occupancies Inspec. Type Owner Name Address City State Zip V -Does Not Meet Requirements NV- Appears To Meet Requirements NA -Not Applicable (See Additional Instructions On Back) V NV NA 1. Exterior V 111V NA 4. Storage V NV NA 8. Sprinkler Systems ❑ " ❑ a. Fire Lanes marked /unobstructed ❑ ❑ d. No combustible storage under ❑ ❑ p b. Controls readily accessible ❑ 1L ❑ b. Address visible 1 . ,,.S,U¢!2 -L00h unprotected stairways ❑ ❑ [V c. Valves locked open or ❑ ❑ A. c. Fire hydrant(s) eS s) accessible J. ❑ ❑ e. Storage maintained 2' below supervised ceiling (unsprinklered) ❑ ❑ [ d. Properly serviced ❑ y ❑ d. Combustible accumulation(s) acceptable ❑ ❑ f. Storage maintained 18" below ❑ ❑ E4 e. Heads in good condition ❑ ❑ 64.. e. F.D. lock box kl resent sprinkler heads p ❑ ❑ y f. Wrench /spare heads present ❑ ❑ I f. F.D. connections visible /good ❑ N. ❑ g. Aisles maintained - 44" min. condition ❑ g ❑ h. Rubbish, oily rags, waste 9. Fire Alarm Equipment material property stored ❑ pia ❑ a. Detectors (smoke, heat) properly 2. Exit Features installed ❑ 5J ❑ a. Adequate number of exits 5. Flammable /Comb. Liquids ❑ ❑ A b. Pull stations properly installed ❑ . ❑ b. Exits, aisles and corridors ❑ [ 9 ❑ a. Proper quantities ❑ ❑ c. Detectors needed free of obstructions ❑ [V ❑ b. Proper storage /dispensing ❑ ,i ❑ d. Properly serviced /maintained ❑ tA ❑ c. Exits openable from inside ❑ © ❑ c. No sources of ignition ❑ IX1 ❑ e. Tests /drills conducted ❑ ;S, ❑ d. Exit hardware present and ❑ [ ❑ d. Adequate ventilation 10. Other Fire Protection Equip. operational q p ❑ 7 ❑ e. Proper electrical equipment ❑ E ❑ e. Exit signs present ❑ 10 a. Standpipes needed ❑ ❑ t . Exit illumination adequate 6. Utility, Mechanical, HVAC ❑ CI b. Standpipe /hose in good cond. J g. Emergency lighting present and ❑ K U a. Relief valve present on boilers ❑ ❑ c. Adequate coverage operational and water heaters ❑ ❑ )Z[ d. Hood system -fuel shutoff present ❑ Li p h. Occupant load posted and ❑ ❑ b. Shut off valve present on gas ❑ ❑ e. Properly serviced/maintained maintained appliances ,y ❑ [K1 ❑ i. Interior finish acceptable ❑ r Li c. Approved piping/connectors Dale t` 16 Electrical ❑ ❑ j. Stairway ID present and appliances used ❑ ❑ a. Appliances /fixtures in good ❑ Y Proper venting g present and in . ❑ d. Pro condition 3. Construction Features good condition ❑ E4 ❑ b. Overcurrent protection present ❑ ❑ a. Fire separations present ❑ [' ❑ e. Combustion air supply present ❑ X ❑ c. Proper wiring /connections and maintained ❑ 5- ❑ f. Adequate clearances between ❑ I IK ❑ d. Extension cords not used in ❑ C(! ❑ b. Openings in fire walls sealed combustibles and appliances place of fixed wiring ❑ ❑ $, c. Rated fire doors present and ❑ It g. Clean ducts and filters ❑ ix ❑ e. Proper use of wiring and equip. operational (closing/latching) ❑ Al n f. 30" clear access to panels ❑ N ❑ d. Vertical openings acceptable 7 . Fire Extinguishers provided ❑ „❑ a. Readily accessible 4. Storage ❑ - ❑ - b. Proper number and type 12. Miscellaneous ❑ IS ❑ a. Storage neat and orderly [� c. Suitable location ❑ ❑ X a. Proper storage of compressed ❑ Ft1 ❑ b. No combustible storage in gases ❑ � ❑ d. Properly serviced /maintained boiler or mechanical rooms ❑ ❑ b. Interior decorations acceptable ❑ 4 ❑ c. No combustible storage in 8. Sprinkler Systems or flame retardant unprotected attics ❑ ❑ a. Adequate coverage ❑ ❑ X c. No smoking provisions enforced Comments. 1/0 574rrrt.- S i e . Al • , f e i ar, . . -.•- c:+ lv, /$ T /i Incf e 6 ,- C4 n 1 L r p 61li ► ' , . O-IN A 1 . t ✓ Pt,` - • 5t t' DcV ! ‘ o Re- Inspect Date Inspector _ Fire Dept. r _ Property Owner/R. , res , tative s �f >; .e 4 e A - t/ • .. 6 1 Form 4185 Disk STW 2 • NOTICE TO THE OWNER, OCCUPANT, LESSEE, OR AGENT OF THE PROPERTY WHOSE ADDRESS IS LISTED ON THE REVERSE SIDE: In accordance with Minnesota Statutes 299F.011, an inspection of your property was conducted for the purpose of fire and life safety. At the time of the inspection, certain conditions were observed which do not meet minimum require- ments of the MN Uniform Fire Code. Those items are checked in the first column, under V. A follow -up inspection will be conducted on or after the date listed on the bottom of the inspection report. The purpose of the follow -up inspection is to determine that any violations or deficiencies observed on the previous inspection have been corrected. Failure to comply with fire prevention requirements is a violation of state statute and /or municipal ordinance. There is a variance procedure provided by the statute. Thank you for your assistance with these fire prevention items. If you have any questions or need additional informa- tion, please feel free to contact the Bayport Fire Department at 439 -6992.