Loading...
HomeMy WebLinkAbout1989-08-11 NAC Planning Report • • 1 northwest associated consultants, inc. PLANNING REPORT FILE C glij y T FA O: LaVonne Wilson FROM: Curtis Gutoske DATE: • 11 August 1989 RE: Oak Park Heights - Conoco CUP - Highway 36 and Omaha Avenue FILE NO: 798.02 - 89.14 BACKGROUND A revised site plan (Exhibit A) has been submitted by the Conoco Company for the development of a gas station /convenience store with car wash at the corner of Omaha Avenue and the South Highway 36 frontage road (Dairy Queen site). The subject property is zoned B -2, General Business. This report will serve to review the site plan against the Zoning Ordinance B -2 District performance standards. In addition, all applications necessary to process the proposed development: will be identified along with the additional submission material required. CASE REVIEW Conditional Use Permit- The proposed gas station, /convenience store with car wash requires a conditional use permit within the B -2 District. The applicant must apply for said permit and be subject to the regulations of Sections 401.11.D (1), (2), and (3) of the City Zoning Ordinance. Lot Standards. The lot width of 178.04 feet and lot area of. 39,543 square feet meet the minimum respective requirements of 150 feet and 2.0,000 square feet for a motor fuel station. Setbacks. The proposed placement of the building and canopies have been found to conform to all B - -2 District setbacks. The placement of the storage and trash structure has been found to conform to all applicable accessory building setbacks. 4601 excelsior blvd., ste. 410, minneapolis, mn 55416 (612) 925 -9420 fax 925 -2721 • • Parking. Six parking spaces have been provided on the site. The parking required for the proposed uses is eleven (11) spaces based upon Ordinance standards. This requirement was calculated as follows: Gross Floor Net Floor Parking Area Area Required Convenience Store Area 1,032 sf X .9 929 sf @ 1/200 5 spaces Storage Area 937 sf X .9 843 sf @ 1/500 2 spaces Motor Fuel Service -- -- 4 spaces TOTAL 11 spaces The site plan should be revised to provide the additional parking spaces required. Exhibit B illustrates a recommended layout which may accommodate the increased parking without significantly altering the balance of the site plan. A change that would be required is the shifting of the Omaha Avenue curb cut approximately seven (7) feet to the north, subject to the further comments of this report. The parking stalls illustrate an 18 foot depth. They should be increased to 20 feet to meet minimum Ordinance requirements. Circulation. Both the Omaha Avenue and frontage road curb cuts exceed the maximum allowed by Ordinance (32 feet on State Highways and 24 feet on local streets). The curb cuts should be reduced to meet Ordinance requirements or they will require the approval of a CUP subject to the review of the City Engineer. In review of the previous Conoco site plan, two curb cuts were proposed along Omaha Avenue. It was recommended they be combined into one and aligned with one of the Honda shop curb cuts to the west. While the applicant has combined the two curb cuts into one, it is not in alignment with either of the Honda property curb cuts. It is still recommended this realignment be required subject to the further comments of the City Engineer. With regards to the balance of the circulation within the site, the proposed layout has been found to be acceptable. Proper spacing has been provided between the gas pump islands and the underground storage tanks have been found to be in an acceptable location. Grading and Drainage. A grading and drainage plan must be submitted subject to the review of the City Engineer. This plan should be submitted prior to approval of a CUP is given. 2 •. . . Utilities. A utility plan must also be submitted subject to the review of the City Engineer. Again, this plan should be submitted prior to the granting of any approvals. Landscaping. A landscaping plan must also be submitted subject to the review of our office and the Building Inspector. Said plan must illustrate all planting materials to be used on the site by specie, size, and quantity. The Ordinance requires that all income producing properties be landscaped in a manner that gives emphasis to the perimeter of property and the perimeter of the building (Section 401.03.B.7.d). The proposed site plan does illustrate a desirable amount of open space on the site's north, east, and south boundaries. It is within these areas, in addition to the open area immediately east of the building, that landscaping should be concentrated. As a last comment, there appears to be an inordinate amount of impervious surface in the northwest corner of the lot. It is recommended the pavement area be scaled back and replaced with green space (sod, landscaping, etc.) as illustrated in Exhibit B. Car Wash. The location, circulation, and provision of stacking space for the proposed car wash have been found to be acceptable. Trash Enclosure. The location of the trash enclosure /storage facility has been found to be acceptable with the exception that it should be shifted slightly to the east to accommodate the additional parking required. Detailed drawings of the enclosure must also be submitted to determine its compatibility with the principle structure. Signage. A signage plan must be submitted and approved prior to the issuance of building permits. The signage plan must indicate all signs, with dimensions, to be used on the site. This includes signage to be used for the display of gas prices. The signage plan must also illustrate building elevations to determine the amount of allowable signage. With the proposed development to exist on a corner lot, the following combination of signs are allowed: one free - standing and two wall, one free- standing, one wall and one canopy, or one free - standing and two canopy. Sizes will be dependent on the size of the building facades. Lighting. The Ordinance requires that all lighting to be used on the site be positioned and hooded such that no direct light is visible from the public right -of -way and in compliance with Section 401.03.B.8. This should be accomplished through the submission of a lighting plan subject to the review of the Building Inspector. 3 • • RECOMMENDATION The proposed site plan for the Conoco gas station /convenience store has been found to be generally acceptable. There are a number of items, however, that must be resolved before any approval or permits can be granted. These items are: 1. A conditional use permit is applied for the development of a convenience store with motor fuel service and car wash. 2. The site plan is revised in accordance with Exhibit B of this report or in an alternative fashion found acceptable by the City Engineer and City Planner. 3. A minimum of eleven parking stalls are provided at 9' X 20' in size. 4. The curb cut widths are reduced to meet Ordinance standards or are granted via the CUP subject to the acceptability of the City Engineer. 5. The following materials are submitted upon the application of the required CUP: o Grading and Drainage Plan o Utility Plan o Landscaping Plan o Signage Plan o Building Elevations o Trash Enclosure Detail o Lighting Plan 6. Comments of other City Staff. cc: Lyle Eckberg Mark Vierling Joe Anderlik Frank Leier Bill Schneider 4 • , , • • • , • H1HON • . . . . , 01 211.00' ■-• ......7 ......... .- ■. ■ ■ ...- ........ .....■ ■• ....■..... ...... 1 0 * SFTBACK I I • (F----- --", i•'; . 5 : , I i - ir_ ••• ,-------------- - _ 1 0 , -- . L . _ 111 - 0 il rl c • s- •"" / a ,/ /' / 1 ; U , a 1 / / ',/ F- • < .';'• , _..... / 1 41 , ,, I , v ...■ .. 4 .. Cr NIi111111,10 • • LIJ = 0 I I 4, \ - ../,A fo " 44' ,,,, Qt /4,, , \ / LL .p„,....0 \ 4, \ 4" 9399130 .02 1 I 20' -0' • go atm .er 01 222 PI .90 .1 .11.1 1 - '-•,',,__________ ...-__-__-- HIHO\ — =-AV V -VIA° .00102 14.00.901.111 -.1 e --- --- ----1 e li EXHIBIT A - PROPOSED SITE PLAN • • 0 Z ii: . < EA 0 CO) . . I IltiON Z 4 —I . ILI CI ' 0 C0 0. I'••• 0 . M „ 2 \ b„. .54•07 241 00' -- --..—.=-. ..- .-... .-- --. F1B0C4 ix ',- c ., c :k\ ' . ,•••.\\ , . ■.', % , / / 1 ,.. _ ...., In 41 co "7 1 . . „,,,,„ > 0 <• ,/ ILI ‹./ I.•• an .1 -- CC 1 .■ , CC 0) . 0 w 1 N 1 A ,..,., • $,,, •,,, ( • pp, (5 IIA 411( 0 .%., • ■ 4 A A z Z 4 0 C:1 cc , ._ • a, _.. , 1 ,,,, I■ uj g N \ . . )1241113S ,02 IM ‘S -- :1-- ezz 14.90.,S.IN ''`4,.„. ,40/ ‘ '.==u4c_...=- ,- -- -- - --------- ---- - — --'- ' ---- -.--- ---------- 1 - ------,.---....,--- ---- Z 1 _ _ I -ULU\ C V VI-IVIA10 OD' 92 11.40,40.IN =41 0 8 I i ILI 1 CO •") CC CO II 0 0 0 0 EXHIBIT B - RECOMMENDED CHANGES