1" SRII Water Meter Receipt
Commercial Water Meter 3/4 to 50 GPM
Installation Site: ' ' <-, 7a v., 41r P`l e /Q*t 4
Contractor: -
Meter Type and Size: Sensus SRII 1 inch ECR 1000 gallon read
Serial No: 6 (q 7 7`/ ' 7 ECR Number: 5 K 5 /
Radio ID *: ( `� %( Z Date Installed: C r7
Utility Account No.: kg -167_2 -"5 e 3 X Sewer & Water Water Only
2003 With Radio* Without Radios
1 inch SRII ECRD -S* $359.00 $205
* With Connectors, shipping, admin and taxes
Check Amount & Number: ea 14 ' ' P Received by:
Meter Received By: k Date :
*Radio transmitter to be installed by City after meter installation.
To avoid damage, the meter must be installed in accordance with the attached
installation guidelines.
Special Instructions: f v‘; -9 fr 1 ,-"/ ° ' 7 a --(' ° 1
� — I "el - fi � 1 rn ✓ f i - 1 f `-e+f
Routing:
1. Public Works Foreman (Install Radio)
2. Public Works Administration (Establish Account Number) T, 1
3. Utility Billing Clerk (Open utility account) V
4. sr >/
Updated 5/23/01
TREE CITY U.S.A.
PD -400
invensys
SR° AND SR II° WATER METERS
INSTALLATION GUIDELINES
1. Meter is intended for measuring potable, cold water in one direction only.
2. Meter is to be installed in a horizontal pipeline with the register facing upward and readily
accessible for reading.
3. Suitable shut -off valves should be installed adjacent to both the inlet and outlet of the
meter so service may be shut off without undue inconvenience to the customer whenever
the meter must be removed.
4. Clean and flush the service line thoroughly on the inlet side of the meter before installing
the meter.
5. Remove the spud thread protectors and set the meter with the arrow on the meter
pointed toward the outlet (customer's side).
6. To insure unrestricted flow of water through the meter, use the proper size and type of
gaskets. Connections should only be sufficiently tightened to seal; do not over - tighten.
Do not use pipe sealant, tape or putty on the meter spud threads.
7. After the meter is installed, shut the outlet shut -off valve. Open the inlet shut -off valve
slowly until the meter is full of water and there are no leaks.
8. Open the outlet valve slowly until air is out of the meter and service line. Open a valve
downstream of the meter slowly and insure that no foreign debris in the water okbstructs
the operation of the meter.
CAUTION: Introducing water too quickly into the meter will damage the meter's
internal components. The meter and service line must be free of air before operating
the meter at normal flow rates.
9. Install an electrical grounding strap around the meter for maintenance safety while
repairing or removing meter.
NOTE: For additional details, refer to the Invensys Water Meter Installation & Operating
Instructions or the American Water Works Association (AWWA) Manual M6.
If the meter to be installed requires the installation of a remote, follow the applicable
installation guide.
Montanari Homes
Office/Warehouse Fixture Unit Calculation Sheet
Max
Flush Fixture Intermittent
Space Fixture Number Flush Valve Tank Units Flow (gpm)
Min Max Min Max Min Max Min Max Min Max
Common Toliets 2 2 2 2 10 10
Urinals 0 0 0 0 0
Lav 2 2 4 4
Kit Sink 0 0 0 0
Dishwasher 0 0 0 0
Janitor Sink 1 1 2 2
Drink Fountain 1 1 1 1
Hose Bibs 3 3 9 9
Total 26 26
2nd Floor Toliets 3 3 3 3 15 15
Urinals 0 0 0 0
Lav 3 3 6 6
Kit Sink 1 1 2 2
Dishwasher 0 0 0
Janitor Sink 1 1 2 2
Drink Fountain 0 0 0
Hose Bibs 0 0 0
Shower 1 1 2 2
Bar Sinks 3 3 3 3
Total 30 30
Tenents Toliets 4 2 4 10 20
Urinals 0 0 0 0
Lav 4 2 4 10 8
Kit Sink 0 0 0 0
Dishwasher 0 0 0 0
Janitor Sink 0 0 0 0
Drink Fountain 0 0 0 0
Hose Bibs 0 0 0 0
Total 20 28
76 84 37 40 1 inch Water Meter
List other water using equipment (boilers, cooling towers, humidifier, etc)
Location Equipment Flow Comments